Skip to main content
Top
Published in:
Cover of the book

2015 | OriginalPaper | Chapter

Computational Methods for Molecular Imaging

Authors : Fei Gao, Pengcheng Shi

Published in: Computational Methods for Molecular Imaging

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Molecular imaging is a new research discipline enabling the visualization, characterization and quantification of biologic processes taking place at the cellular and subcellular levels within intact living subjects. Applications of molecular imaging techniques will benefit various clinical practices including classification and tracking of chemotherapy and treatment planning of radiotherapy, as well as drug discovery and development. Molecular imaging typically includes two or three dimensional imaging with quantification over time, and is often applied on molecular imaging modalities, such as Positron Emission Tomography (PET), and Single Photon Emission Computed Tomography (SPECT). Computational methods serve as an essential part in molecular imaging. Various computational methods are developed to accelerate image processing, identify underlying diseases hidden in the image volumes, evaluate the effectiveness of drug and radiotherapy etc. Computational methods for molecular imaging are in a fast growing field and full of potentials and challenges, and related topics have attracted many researchers from both academia and industry. This book covers the selected topics in computational methods for molecular imaging. As the start, this review provides a brief introduction to the current status of computational methods for molecular imaging and their applications.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Alenius, S., Ruotsalainen, U.: Bayesian image reconstruction for emission tomography based on median root prior. Eur. J. Nucl. Med. 24(3), 258–265 (1997) Alenius, S., Ruotsalainen, U.: Bayesian image reconstruction for emission tomography based on median root prior. Eur. J. Nucl. Med. 24(3), 258–265 (1997)
2.
go back to reference Alessio, A., Kinahan, P.: Pet image reconstruction. Nucl. Med., 2 (2006) Alessio, A., Kinahan, P.: Pet image reconstruction. Nucl. Med., 2 (2006)
3.
go back to reference Alessio, A.M., Stearns, C.W., Tong, S., Ross, S.G., Kohlmyer, S., Ganin, A., Kinahan, P.E.: Application and evaluation of a measured spatially variant system model for pet image reconstruction. IEEE Trans. Med. Imaging 29(3), 938–949 (2010)CrossRef Alessio, A.M., Stearns, C.W., Tong, S., Ross, S.G., Kohlmyer, S., Ganin, A., Kinahan, P.E.: Application and evaluation of a measured spatially variant system model for pet image reconstruction. IEEE Trans. Med. Imaging 29(3), 938–949 (2010)CrossRef
4.
go back to reference Bailey, D., Townsend, D., Valk, P., Maisey, M.: Positron Emission Tomography: Basic Sciences. Springer, New York (2005) Bailey, D., Townsend, D., Valk, P., Maisey, M.: Positron Emission Tomography: Basic Sciences. Springer, New York (2005)
5.
go back to reference Bartenstein, P., Minoshima, S., Hirsch, C., Buch, K., Willoch, F., Mösch, D., Schad, D., Schwaiger, M., Kurz, A., et al.: Quantitative assessment of cerebral blood flow in patients with Alzheimer’s disease by SPECT. J. Nucl. Med. 38(7), 1095 (1997) Bartenstein, P., Minoshima, S., Hirsch, C., Buch, K., Willoch, F., Mösch, D., Schad, D., Schwaiger, M., Kurz, A., et al.: Quantitative assessment of cerebral blood flow in patients with Alzheimer’s disease by SPECT. J. Nucl. Med. 38(7), 1095 (1997)
6.
go back to reference Bateman, T.M., Heller, G.V., McGhie, A.I., Friedman, J.D., Case, J.A., Bryngelson, J.R., Hertenstein, G.K., Moutray, K.L., Reid, K., Cullom, S.J.: Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT. J. Nucl. Cardiol. 13(1), 24–33 (2006)CrossRef Bateman, T.M., Heller, G.V., McGhie, A.I., Friedman, J.D., Case, J.A., Bryngelson, J.R., Hertenstein, G.K., Moutray, K.L., Reid, K., Cullom, S.J.: Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT. J. Nucl. Cardiol. 13(1), 24–33 (2006)CrossRef
7.
go back to reference Beyer, T., Tellmann, L., Nickel, I., Pietrzyk, U.: On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies. J. Nucl. Med. 46(4), 596–602 (2005) Beyer, T., Tellmann, L., Nickel, I., Pietrzyk, U.: On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies. J. Nucl. Med. 46(4), 596–602 (2005)
8.
go back to reference Boellaard, R., O’Doherty, M.J., Weber, W.A., Mottaghy, F.M., Lonsdale, M.N., Stroobants, S.G., Oyen, W.J., Kotzerke, J., Hoekstra, O.S., Pruim, J., et al.: FDG PET and PET/CT: Eanm procedure guidelines for tumour pet imaging: version 1.0. Eur. J. Nucl. Med. Mol. Imaging 37(1), 181–200 (2010)CrossRef Boellaard, R., O’Doherty, M.J., Weber, W.A., Mottaghy, F.M., Lonsdale, M.N., Stroobants, S.G., Oyen, W.J., Kotzerke, J., Hoekstra, O.S., Pruim, J., et al.: FDG PET and PET/CT: Eanm procedure guidelines for tumour pet imaging: version 1.0. Eur. J. Nucl. Med. Mol. Imaging 37(1), 181–200 (2010)CrossRef
9.
go back to reference Bonte, F.J., Weiner, M.F., Bigio, E.H., White, C., et al.: Brain blood flow in the dementias: SPECT with histopathologic correlation in 54 patients. Radiology 202(3), 793–797 (1997)CrossRef Bonte, F.J., Weiner, M.F., Bigio, E.H., White, C., et al.: Brain blood flow in the dementias: SPECT with histopathologic correlation in 54 patients. Radiology 202(3), 793–797 (1997)CrossRef
10.
go back to reference Boucher, L., Rodrigue, S., Lecomte, R., Bénard, F.: Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J. Nucl. Med. 45(2), 214–219 (2004) Boucher, L., Rodrigue, S., Lecomte, R., Bénard, F.: Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J. Nucl. Med. 45(2), 214–219 (2004)
11.
go back to reference Brankov, J.G., Galatsanos, N.P., Yang, Y., Wernick, M.N.: Segmentation of dynamic PET or fMRI images based on a similarity metric. IEEE Trans. Nucl. Sci. 50(5), 1410–1414 (2003)CrossRef Brankov, J.G., Galatsanos, N.P., Yang, Y., Wernick, M.N.: Segmentation of dynamic PET or fMRI images based on a similarity metric. IEEE Trans. Nucl. Sci. 50(5), 1410–1414 (2003)CrossRef
12.
go back to reference Buck, A.K., Halter, G., Schirrmeister, H., Kotzerke, J., Wurziger, I., Glatting, G., Mattfeldt, T., Neumaier, B., Reske, S.N., Hetzel, M.: Imaging proliferation in lung tumors with PET: 18F-FLT Versus 18F-FDG. J. Nucl. Med. 44(9), 1426–1431 (2003) Buck, A.K., Halter, G., Schirrmeister, H., Kotzerke, J., Wurziger, I., Glatting, G., Mattfeldt, T., Neumaier, B., Reske, S.N., Hetzel, M.: Imaging proliferation in lung tumors with PET: 18F-FLT Versus 18F-FDG. J. Nucl. Med. 44(9), 1426–1431 (2003)
13.
go back to reference Catafau, M., Bullich, S.: Molecular imaging PET and SPECT approaches for improving productivity of antipsychotic drug discovery and development. Curr. Med. Chem. 20(3), 378–388 (2013) Catafau, M., Bullich, S.: Molecular imaging PET and SPECT approaches for improving productivity of antipsychotic drug discovery and development. Curr. Med. Chem. 20(3), 378–388 (2013)
14.
go back to reference Cobelli, C., Foster, D., Toffolo, G.: Tracer Kinetics in Biomedical Research: From Data to Model. Kluwer Academic/Plenum Publishers, New York (2000) Cobelli, C., Foster, D., Toffolo, G.: Tracer Kinetics in Biomedical Research: From Data to Model. Kluwer Academic/Plenum Publishers, New York (2000)
15.
go back to reference Crum, W., Hartkens, T., Hill, D.: Non-rigid image registration: theory and practice. Br. J. Radiol. 77(suppl 2), S140–S153 (2004)CrossRef Crum, W., Hartkens, T., Hill, D.: Non-rigid image registration: theory and practice. Br. J. Radiol. 77(suppl 2), S140–S153 (2004)CrossRef
16.
go back to reference Cruz, J.A., Wishart, D.S.: Applications of machine learning in cancer prediction and prognosis. Cancer Inf. 2, 59 (2006) Cruz, J.A., Wishart, D.S.: Applications of machine learning in cancer prediction and prognosis. Cancer Inf. 2, 59 (2006)
17.
go back to reference Daisne, J.F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., Grégoire, V.: Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms. Radiother. Oncol. 69(3), 247–250 (2003)CrossRef Daisne, J.F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., Grégoire, V.: Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms. Radiother. Oncol. 69(3), 247–250 (2003)CrossRef
18.
go back to reference Dimitrakopoulou-Strauss, A., Strauss, L.G., Heichel, T., Wu, H., Burger, C., Bernd, L., Ewerbeck, V.: The role of quantitative 18F-FDG PET studies for the differentiation of malignant and benign bone lesions. J. Nucl. Med. 43(4), 510–518 (2002) Dimitrakopoulou-Strauss, A., Strauss, L.G., Heichel, T., Wu, H., Burger, C., Bernd, L., Ewerbeck, V.: The role of quantitative 18F-FDG PET studies for the differentiation of malignant and benign bone lesions. J. Nucl. Med. 43(4), 510–518 (2002)
19.
go back to reference Drever, L., Roa, W., McEwan, A., Robinson, D.: Iterative threshold segmentation for PET target volume delineation. Med. Phys. 34, 1253 (2007)CrossRef Drever, L., Roa, W., McEwan, A., Robinson, D.: Iterative threshold segmentation for PET target volume delineation. Med. Phys. 34, 1253 (2007)CrossRef
20.
go back to reference El Naqa, I., Grigsby, P., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al.: Exploring feature-based approaches in pet images for predicting cancer treatment outcomes. Pattern Recognit. 42(6), 1162–1171 (2009)CrossRef El Naqa, I., Grigsby, P., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al.: Exploring feature-based approaches in pet images for predicting cancer treatment outcomes. Pattern Recognit. 42(6), 1162–1171 (2009)CrossRef
21.
go back to reference Elstrom, R., Guan, L., Baker, G., Nakhoda, K., Vergilio, J.A., Zhuang, H., Pitsilos, S., Bagg, A., Downs, L., Mehrotra, A., et al.: Utility of FDG-PET scanning in lymphoma by who classification. Blood 101(10), 3875–3876 (2003)CrossRef Elstrom, R., Guan, L., Baker, G., Nakhoda, K., Vergilio, J.A., Zhuang, H., Pitsilos, S., Bagg, A., Downs, L., Mehrotra, A., et al.: Utility of FDG-PET scanning in lymphoma by who classification. Blood 101(10), 3875–3876 (2003)CrossRef
22.
go back to reference Erdi, Y.E., Mawlawi, O., Larson, S.M., Imbriaco, M., Yeung, H., Finn, R., Humm, J.L.: Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer 80(S12), 2505–2509 (1997)CrossRef Erdi, Y.E., Mawlawi, O., Larson, S.M., Imbriaco, M., Yeung, H., Finn, R., Humm, J.L.: Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer 80(S12), 2505–2509 (1997)CrossRef
23.
go back to reference Erlandsson, K., Buvat, I., Pretorius, P.H., Thomas, B.A., Hutton, B.F.: A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys. Med. Biol. 57(21), R119 (2012)CrossRef Erlandsson, K., Buvat, I., Pretorius, P.H., Thomas, B.A., Hutton, B.F.: A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys. Med. Biol. 57(21), R119 (2012)CrossRef
24.
go back to reference Freedman, N., Schechter, D., Klein, M., Marciano, R., Rozenman, Y., Chisin, R.: SPECT attenuation artifacts in normal and overweight persons: insights from a retrospective comparison of Rb-82 positron emission tomography and Tl-201 SPECT myocardial perfusion imaging. Clin. Nucl. Med. 25(12), 1019–1023 (2000)CrossRef Freedman, N., Schechter, D., Klein, M., Marciano, R., Rozenman, Y., Chisin, R.: SPECT attenuation artifacts in normal and overweight persons: insights from a retrospective comparison of Rb-82 positron emission tomography and Tl-201 SPECT myocardial perfusion imaging. Clin. Nucl. Med. 25(12), 1019–1023 (2000)CrossRef
25.
go back to reference Gao, F., Liu, H., Jian, Y., Shi, P.: Dynamic dual-tracer PET reconstruction. In: Information Processing in Medical Imaging, pp. 38–49. Springer (2009) Gao, F., Liu, H., Jian, Y., Shi, P.: Dynamic dual-tracer PET reconstruction. In: Information Processing in Medical Imaging, pp. 38–49. Springer (2009)
26.
go back to reference Gao, F., Liu, H., Shi, P.: Efficient robust reconstruction of dynamic PET activity maps with radioisotope decay constraints. Med. Image Comput. Comput.-Assist. Interv. (MICCAI 2010) 3, 571–578 (2010) Gao, F., Liu, H., Shi, P.: Efficient robust reconstruction of dynamic PET activity maps with radioisotope decay constraints. Med. Image Comput. Comput.-Assist. Interv. (MICCAI 2010) 3, 571–578 (2010)
27.
go back to reference Gao, F., Liu, H., Shi, P.: Robust estimation of kinetic parameters in dynamic PET imaging. Med. Image Comput. Comput.-Assist. Interv. - MICCAI 2011, 6891, 492–499 (2011) Gao, F., Liu, H., Shi, P.: Robust estimation of kinetic parameters in dynamic PET imaging. Med. Image Comput. Comput.-Assist. Interv. - MICCAI 2011, 6891, 492–499 (2011)
28.
go back to reference Gee, J., Ding, L., Xie, Z., Lin, M., DeVita, C., Grossman, M.: Alzheimer’s disease and frontotemporal dementia exhibit distinct atrophy-behavior correlates: a computer-assisted imaging study1. Acad. Radiol. 10(12), 1392–1401 (2003)CrossRef Gee, J., Ding, L., Xie, Z., Lin, M., DeVita, C., Grossman, M.: Alzheimer’s disease and frontotemporal dementia exhibit distinct atrophy-behavior correlates: a computer-assisted imaging study1. Acad. Radiol. 10(12), 1392–1401 (2003)CrossRef
29.
go back to reference Geets, X., Lee, J.A., Bol, A., Lonneux, M., Grégoire, V.: A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur. J. Nucl. Med. Mol. Imaging 34(9), 1427–1438 (2007)CrossRef Geets, X., Lee, J.A., Bol, A., Lonneux, M., Grégoire, V.: A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur. J. Nucl. Med. Mol. Imaging 34(9), 1427–1438 (2007)CrossRef
30.
go back to reference Goerres, G.W., Kamel, E., Heidelberg, T.N.H., Schwitter, M.R., Burger, C., von Schulthess, G.K.: PET-CT image co-registration in the thorax: influence of respiration. Eur. J. Nucl. Med. Mol. Imaging 29(3), 351–360 (2002)CrossRef Goerres, G.W., Kamel, E., Heidelberg, T.N.H., Schwitter, M.R., Burger, C., von Schulthess, G.K.: PET-CT image co-registration in the thorax: influence of respiration. Eur. J. Nucl. Med. Mol. Imaging 29(3), 351–360 (2002)CrossRef
31.
go back to reference Gunn, R., Gunn, S., Turkheimer, F., Aston, J., Cunningham, V.: Tracer kinetic modeling via basis pursuit. In: Senda, M., Kimura, Y., Herscovitch, P. (eds.) Brain Imaging Using PET. Academic Press (2002) Gunn, R., Gunn, S., Turkheimer, F., Aston, J., Cunningham, V.: Tracer kinetic modeling via basis pursuit. In: Senda, M., Kimura, Y., Herscovitch, P. (eds.) Brain Imaging Using PET. Academic Press (2002)
32.
go back to reference Gunn, R.N., Gunn, S.R., Cunningham, V.J.: Positron emission tomography compartmental models. J. Cereb. Blood Flow Metab. 21(6), 635–652 (2001)CrossRef Gunn, R.N., Gunn, S.R., Cunningham, V.J.: Positron emission tomography compartmental models. J. Cereb. Blood Flow Metab. 21(6), 635–652 (2001)CrossRef
33.
go back to reference Gunn, R.N., Gunn, S.R., Turkheimer, F.E., Aston, J.A., Cunningham, V.J.: Positron emission tomography compartmental models: A basis pursuit strategy for kinetic modeling. J. Cereb. Blood Flow Metab. 22(12), 1425–1439 (2002)CrossRef Gunn, R.N., Gunn, S.R., Turkheimer, F.E., Aston, J.A., Cunningham, V.J.: Positron emission tomography compartmental models: A basis pursuit strategy for kinetic modeling. J. Cereb. Blood Flow Metab. 22(12), 1425–1439 (2002)CrossRef
34.
go back to reference Gunn, R.N., Lammertsma, A.A., Hume, S.P., Cunningham, V.J.: Parametric imaging of ligand-receptor binding in pet using a simplified reference region model. Neuroimage 6(4), 279–287 (1997)CrossRef Gunn, R.N., Lammertsma, A.A., Hume, S.P., Cunningham, V.J.: Parametric imaging of ligand-receptor binding in pet using a simplified reference region model. Neuroimage 6(4), 279–287 (1997)CrossRef
35.
go back to reference Hajnal, J.V.: Medical Image Registration. CRC Press LLC (2001) Hajnal, J.V.: Medical Image Registration. CRC Press LLC (2001)
36.
go back to reference Huang, X., Hill, N.A., Ren, J., Guiraudon, G., Boughner, D., Peters, T.M.: Dynamic 3D ultrasound and MR image registration of the beating heart. In: Medical Image Computing and Computer-Assisted Intervention-MICCAI 2005, pp. 171–178. Springer (2005) Huang, X., Hill, N.A., Ren, J., Guiraudon, G., Boughner, D., Peters, T.M.: Dynamic 3D ultrasound and MR image registration of the beating heart. In: Medical Image Computing and Computer-Assisted Intervention-MICCAI 2005, pp. 171–178. Springer (2005)
37.
go back to reference Hutton, B.F., Buvat, I., Beekman, F.J.: Review and current status of SPECT scatter correction. Phys. Med. Biol. 56(14), R85 (2011)CrossRef Hutton, B.F., Buvat, I., Beekman, F.J.: Review and current status of SPECT scatter correction. Phys. Med. Biol. 56(14), R85 (2011)CrossRef
38.
go back to reference Iida, H., Narita, Y., Kado, H., Kashikura, A., Sugawara, S., Shoji, Y., Kinoshita, T., Ogawa, T., Eberl, S.: Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with spect. J. Nucl. Med. Off. Publ. Soc. Nucl. Med. 39(1), 181–189 (1998) Iida, H., Narita, Y., Kado, H., Kashikura, A., Sugawara, S., Shoji, Y., Kinoshita, T., Ogawa, T., Eberl, S.: Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with spect. J. Nucl. Med. Off. Publ. Soc. Nucl. Med. 39(1), 181–189 (1998)
39.
go back to reference Iznaga-Escobar, N.: \(^{188}\)Re-direct labeling of monoclonal antibodies for radioimmunotherapy of solid tumors: Biodistribution, normal organ dosimetry, and toxicology. Nucl. Med. Biol. 25(5), 441–447 (1998)CrossRef Iznaga-Escobar, N.: \(^{188}\)Re-direct labeling of monoclonal antibodies for radioimmunotherapy of solid tumors: Biodistribution, normal organ dosimetry, and toxicology. Nucl. Med. Biol. 25(5), 441–447 (1998)CrossRef
40.
go back to reference Jentzen, W., Freudenberg, L., Eising, E.G., Heinze, M., Brandau, W., Bockisch, A.: Segmentation of PET volumes by iterative image thresholding. J. Nucl. Med. 48(1), 108–114 (2007) Jentzen, W., Freudenberg, L., Eising, E.G., Heinze, M., Brandau, W., Bockisch, A.: Segmentation of PET volumes by iterative image thresholding. J. Nucl. Med. 48(1), 108–114 (2007)
41.
go back to reference Kamasak, M.E., Bouman, C.A., Morris, E.D., Sauer, K.: Direct reconstruction of kinetic parameter images from dynamic PET data. IEEE Trans. Med. Imaging 25, 636–650 (2005)CrossRef Kamasak, M.E., Bouman, C.A., Morris, E.D., Sauer, K.: Direct reconstruction of kinetic parameter images from dynamic PET data. IEEE Trans. Med. Imaging 25, 636–650 (2005)CrossRef
42.
go back to reference Kelly, C.J., Brady, M.: A model to simulate tumour oxygenation and dynamic [18F]-Fmiso PET data. Phys. Med. Biol. 51(22), 5859 (2006)CrossRef Kelly, C.J., Brady, M.: A model to simulate tumour oxygenation and dynamic [18F]-Fmiso PET data. Phys. Med. Biol. 51(22), 5859 (2006)CrossRef
43.
go back to reference Kinahan, P., Townsend, D., Beyer, T., Sashin, D.: Attenuation correction for a combined 3D PET/CT scanner. Med. Phys. 25(10), 2046–2053 (1998)CrossRef Kinahan, P., Townsend, D., Beyer, T., Sashin, D.: Attenuation correction for a combined 3D PET/CT scanner. Med. Phys. 25(10), 2046–2053 (1998)CrossRef
44.
go back to reference Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P., et al.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)CrossRef Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P., et al.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)CrossRef
45.
go back to reference Koeppe, R.A., Gilman, S., Junck, L., Wernette, K., Frey, K.A., et al.: Differentiating Alzheimer’s disease from dementia with Lewy bodies and Parkinson’s disease with (+)-[11C] dihydrotetrabenazine positron emission tomography. Alzheimer’s Dement. J. Alzheimer’s Assoc. 4(1 Suppl 1), S67 (2008)CrossRef Koeppe, R.A., Gilman, S., Junck, L., Wernette, K., Frey, K.A., et al.: Differentiating Alzheimer’s disease from dementia with Lewy bodies and Parkinson’s disease with (+)-[11C] dihydrotetrabenazine positron emission tomography. Alzheimer’s Dement. J. Alzheimer’s Assoc. 4(1 Suppl 1), S67 (2008)CrossRef
46.
go back to reference Krivokapich, J., Smith, G., Huang, S.C., Hoffman, E., Ratib, O., Phelps, M., Schelbert, H.: 13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography. Circulation 80(5), 1328–1337 (1989)CrossRef Krivokapich, J., Smith, G., Huang, S.C., Hoffman, E., Ratib, O., Phelps, M., Schelbert, H.: 13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography. Circulation 80(5), 1328–1337 (1989)CrossRef
47.
go back to reference Li, T., Thorndyke, B., Schreibmann, E., Yang, Y., Xing, L.: Model-based image reconstruction for four-dimensional PET. Med. Phys. 33(5), 1288–1298 (2006)CrossRef Li, T., Thorndyke, B., Schreibmann, E., Yang, Y., Xing, L.: Model-based image reconstruction for four-dimensional PET. Med. Phys. 33(5), 1288–1298 (2006)CrossRef
48.
go back to reference Logan, J., Fowler, J.S., Volkow, N.D., Wang, G.J., Ding, Y.S., Alexoff, D.L.: Distribution volume ratios without blood sampling from graphical analysis of pet data. J. Cereb. Blood Flow Metab. 16(5), 834–840 (1996)CrossRef Logan, J., Fowler, J.S., Volkow, N.D., Wang, G.J., Ding, Y.S., Alexoff, D.L.: Distribution volume ratios without blood sampling from graphical analysis of pet data. J. Cereb. Blood Flow Metab. 16(5), 834–840 (1996)CrossRef
49.
go back to reference Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., Suetens, P.: Multimodality image registration by maximization of mutual information. IEEE Trans. Med. Imaging 16(2), 187–198 (1997)CrossRef Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., Suetens, P.: Multimodality image registration by maximization of mutual information. IEEE Trans. Med. Imaging 16(2), 187–198 (1997)CrossRef
50.
go back to reference Magota, K., Kubo, N., Kuge, Y.: Nishijima, K.i., Zhao, S., Tamaki, N.: Performance characterization of the Inveon preclinical small-animal PET\(/\)SPECT\(/\)CT system for multimodality imaging. Eur. J. Nucl. Med. Mol. Imaging 38(4), 742–752 (2011)CrossRef Magota, K., Kubo, N., Kuge, Y.: Nishijima, K.i., Zhao, S., Tamaki, N.: Performance characterization of the Inveon preclinical small-animal PET\(/\)SPECT\(/\)CT system for multimodality imaging. Eur. J. Nucl. Med. Mol. Imaging 38(4), 742–752 (2011)CrossRef
51.
go back to reference Malladi, R., Sethian, J.A., Vemuri, B.C.: Shape modeling with front propagation: a level set approach. IEEE Trans. Pattern Anal. Mach. Intell. 17(2), 158–175 (1995)CrossRef Malladi, R., Sethian, J.A., Vemuri, B.C.: Shape modeling with front propagation: a level set approach. IEEE Trans. Pattern Anal. Mach. Intell. 17(2), 158–175 (1995)CrossRef
52.
go back to reference Mankoff, D.A.: A definition of molecular imaging. J. Nucl. Med. 48(6), 18N–21N (2007) Mankoff, D.A.: A definition of molecular imaging. J. Nucl. Med. 48(6), 18N–21N (2007)
53.
go back to reference Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R.A., Chefd’hotel, C., Ziegler, S.I., Navab, N., Schwaiger, M., Nekolla, S.G.: Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J. Nucl. Med. 50(4), 520–526 (2009)CrossRef Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R.A., Chefd’hotel, C., Ziegler, S.I., Navab, N., Schwaiger, M., Nekolla, S.G.: Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J. Nucl. Med. 50(4), 520–526 (2009)CrossRef
54.
go back to reference Maruyama, A., Hasegawa, S., Paul, A.K., Xiuli, M., Yoshioka, J., Maruyama, K., Hori, M., Nishimura, T.: Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin wall thickening: Comparison with F-18 FDG-PET. Ann. Nucl. Med. 16(1), 25–32 (2002)CrossRef Maruyama, A., Hasegawa, S., Paul, A.K., Xiuli, M., Yoshioka, J., Maruyama, K., Hori, M., Nishimura, T.: Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin wall thickening: Comparison with F-18 FDG-PET. Ann. Nucl. Med. 16(1), 25–32 (2002)CrossRef
55.
go back to reference Mattes, D., Haynor, D.R., Vesselle, H., Lewellen, T.K., Eubank, W.: PET-CT image registration in the chest using free-form deformations. IEEE Trans. Med. Imaging 22(1), 120–128 (2003)CrossRef Mattes, D., Haynor, D.R., Vesselle, H., Lewellen, T.K., Eubank, W.: PET-CT image registration in the chest using free-form deformations. IEEE Trans. Med. Imaging 22(1), 120–128 (2003)CrossRef
56.
go back to reference Mattes, D., Haynor, D.R., Vesselle, H., Lewellen, T.K., Eubank, W.: PET-CT image registration in the chest using free-form deformations. IEEE Trans. Med. Imaging 22(1), 120–128 (2003)CrossRef Mattes, D., Haynor, D.R., Vesselle, H., Lewellen, T.K., Eubank, W.: PET-CT image registration in the chest using free-form deformations. IEEE Trans. Med. Imaging 22(1), 120–128 (2003)CrossRef
57.
go back to reference Mena, E., Turkbey, B., Mani, H., Adler, S., Valera, V.A., Bernardo, M., Shah, V., Pohida, T., McKinney, Y., Kwarteng, G., Daar, D., Lindenberg, M.L., Eclarinal, P., Wade, R., Linehan, W.M., Merino, M.J., Pinto, P.A., Choyke, P.L., Kurdziel, K.A.: 11C-Acetate PET/CT in localized prostate cancer: A study with MRI and histopathologic correlation. J. Nucl. Med. 53(4), 538–545 (2012)CrossRef Mena, E., Turkbey, B., Mani, H., Adler, S., Valera, V.A., Bernardo, M., Shah, V., Pohida, T., McKinney, Y., Kwarteng, G., Daar, D., Lindenberg, M.L., Eclarinal, P., Wade, R., Linehan, W.M., Merino, M.J., Pinto, P.A., Choyke, P.L., Kurdziel, K.A.: 11C-Acetate PET/CT in localized prostate cancer: A study with MRI and histopathologic correlation. J. Nucl. Med. 53(4), 538–545 (2012)CrossRef
58.
go back to reference Naumann, R., Beuthien-Baumann, B., Reiss, A., Schulze, J., Hänel, A., Bredow, J., Kühnel, G., Kropp, J., Hänel, M., Laniado, M., et al.: Substantial impact of FDG PET imaging on the therapy decision in patients with early-stage Hodgkin’s lymphoma. Br. J. Cancer 90(3), 620–625 (2004)CrossRef Naumann, R., Beuthien-Baumann, B., Reiss, A., Schulze, J., Hänel, A., Bredow, J., Kühnel, G., Kropp, J., Hänel, M., Laniado, M., et al.: Substantial impact of FDG PET imaging on the therapy decision in patients with early-stage Hodgkin’s lymphoma. Br. J. Cancer 90(3), 620–625 (2004)CrossRef
59.
go back to reference Orrù, G., Pettersson-Yeo, W., Marquand, A.F., Sartori, G., Mechelli, A.: Using support vector machine to identify imaging biomarkers of neurological and psychiatric disease: a critical review. Neurosci. Biobehav. Rev. 36(4), 1140–1152 (2012)CrossRef Orrù, G., Pettersson-Yeo, W., Marquand, A.F., Sartori, G., Mechelli, A.: Using support vector machine to identify imaging biomarkers of neurological and psychiatric disease: a critical review. Neurosci. Biobehav. Rev. 36(4), 1140–1152 (2012)CrossRef
60.
61.
go back to reference Pajares, G.: Manuel de la Cruz, J.: A wavelet-based image fusion tutorial. Pattern Recognit. 37(9), 1855–1872 (2004)CrossRef Pajares, G.: Manuel de la Cruz, J.: A wavelet-based image fusion tutorial. Pattern Recognit. 37(9), 1855–1872 (2004)CrossRef
62.
go back to reference Paus, T., Jech, R., Thompson, C.J., Comeau, R., Peters, T., Evans, A.C.: Transcranial magnetic stimulation during positron emission tomography: a new method for studying connectivity of the human cerebral cortex. J. Neurosci. 17(9), 3178–3184 (1997) Paus, T., Jech, R., Thompson, C.J., Comeau, R., Peters, T., Evans, A.C.: Transcranial magnetic stimulation during positron emission tomography: a new method for studying connectivity of the human cerebral cortex. J. Neurosci. 17(9), 3178–3184 (1997)
63.
go back to reference Pellizzari, C., Levin, D.N., Chen, G.T., Chen, C.T.: Image registration based on anatomic surface matching. In: Interactive Image-Guided Neurosurgery pp. 47–62 (1993) Pellizzari, C., Levin, D.N., Chen, G.T., Chen, C.T.: Image registration based on anatomic surface matching. In: Interactive Image-Guided Neurosurgery pp. 47–62 (1993)
64.
go back to reference Pichler, B.J., Kolb, A., Nagele, T., Schlemmer, H.P.: PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J. Nucl. Med. 51(3), 333–336 (2010)CrossRef Pichler, B.J., Kolb, A., Nagele, T., Schlemmer, H.P.: PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J. Nucl. Med. 51(3), 333–336 (2010)CrossRef
65.
go back to reference Pietrzyk, U., KarlHerholz, G., AndreasJacobs, R.: Image registration: validation for PET, SPECT, MRI and CT brain studies. J. Nucl. Med. 35(12), 2011–2018 (1994) Pietrzyk, U., KarlHerholz, G., AndreasJacobs, R.: Image registration: validation for PET, SPECT, MRI and CT brain studies. J. Nucl. Med. 35(12), 2011–2018 (1994)
66.
go back to reference Rahmim, A., Rousset, O., Zaidi, H.: Strategies for motion tracking and correction in PET. PET Clinics 2(2), 251–266 (2007)CrossRef Rahmim, A., Rousset, O., Zaidi, H.: Strategies for motion tracking and correction in PET. PET Clinics 2(2), 251–266 (2007)CrossRef
67.
go back to reference Rousset, O.G., Ma, Y., Evans, A.C., et al.: Correction for partial volume effects in PET: principle and validation. J. Nucl. Med. 39(5), 904–911 (1998) Rousset, O.G., Ma, Y., Evans, A.C., et al.: Correction for partial volume effects in PET: principle and validation. J. Nucl. Med. 39(5), 904–911 (1998)
68.
go back to reference Samarin, A., Burger, C., Wollenweber, S.D., Crook, D.W., Burger, I.A., Schmid, D.T., von Schulthess, G.K., Kuhn, F.P.: PET/MR imaging of bone lesions-implications for pet quantification from imperfect attenuation correction. Eur. J. Nucl. Med. Mol. Imaging 39(7), 1154–1160 (2012)CrossRef Samarin, A., Burger, C., Wollenweber, S.D., Crook, D.W., Burger, I.A., Schmid, D.T., von Schulthess, G.K., Kuhn, F.P.: PET/MR imaging of bone lesions-implications for pet quantification from imperfect attenuation correction. Eur. J. Nucl. Med. Mol. Imaging 39(7), 1154–1160 (2012)CrossRef
69.
go back to reference Strother, S.C., Anderson, J., Hansen, L.K., Kjems, U., Kustra, R., Sidtis, J., Frutiger, S., Muley, S., LaConte, S., Rottenberg, D.: The quantitative evaluation of functional neuroimaging experiments: the NPAIRS data analysis framework. NeuroImage 15(4), 747–771 (2002)CrossRef Strother, S.C., Anderson, J., Hansen, L.K., Kjems, U., Kustra, R., Sidtis, J., Frutiger, S., Muley, S., LaConte, S., Rottenberg, D.: The quantitative evaluation of functional neuroimaging experiments: the NPAIRS data analysis framework. NeuroImage 15(4), 747–771 (2002)CrossRef
70.
go back to reference Strother, S.C., Anderson, J.R., Schaper, K.A., Sidtis, J.J., Liow, J.S., Woods, R.P., Rottenberg, D.A.: Principal component analysis and the scaled subprofile model compared to intersubject averaging and statistical parametric mapping: I. Functional connectivity of the human motor system studied with [150] water pet. J. Cereb. Blood Flow Metab. 15(5), 738–753 (1995)CrossRef Strother, S.C., Anderson, J.R., Schaper, K.A., Sidtis, J.J., Liow, J.S., Woods, R.P., Rottenberg, D.A.: Principal component analysis and the scaled subprofile model compared to intersubject averaging and statistical parametric mapping: I. Functional connectivity of the human motor system studied with [150] water pet. J. Cereb. Blood Flow Metab. 15(5), 738–753 (1995)CrossRef
71.
go back to reference Tharp, K., Israel, O., Hausmann, J., Bettman, L., Martin, W., Daitzchman, M., Sandler, M., Delbeke, D.: Impact of 131I-SPECT/CT images obtained with an integrated system in the follow-up of patients with thyroid carcinoma. Eur. J. Nucl. Med. Mol. Imaging 31(10), 1435–1442 (2004)CrossRef Tharp, K., Israel, O., Hausmann, J., Bettman, L., Martin, W., Daitzchman, M., Sandler, M., Delbeke, D.: Impact of 131I-SPECT/CT images obtained with an integrated system in the follow-up of patients with thyroid carcinoma. Eur. J. Nucl. Med. Mol. Imaging 31(10), 1435–1442 (2004)CrossRef
72.
go back to reference Townsend, D.W., Beyer, T.: A combined PET/CT scanner: the path to true image fusion. Br. J. Radiol. 75(suppl 9), S24–S30 (2002)CrossRef Townsend, D.W., Beyer, T.: A combined PET/CT scanner: the path to true image fusion. Br. J. Radiol. 75(suppl 9), S24–S30 (2002)CrossRef
73.
go back to reference Townsend, D.W., Carney, J.P., Yap, J.T., Hall, N.C.: PET/CT today and tomorrow. J. Nucl. Med. 45(1 suppl), 4S–14S (2004) Townsend, D.W., Carney, J.P., Yap, J.T., Hall, N.C.: PET/CT today and tomorrow. J. Nucl. Med. 45(1 suppl), 4S–14S (2004)
74.
go back to reference Tsoumpas, C., Turkheimer, F., Thielemans, K.: A survey of approaches for direct parametric image reconstruction in emission tomography. Med. Phys. 35, 3963 (2008)CrossRef Tsoumpas, C., Turkheimer, F., Thielemans, K.: A survey of approaches for direct parametric image reconstruction in emission tomography. Med. Phys. 35, 3963 (2008)CrossRef
75.
go back to reference Valk, P., Delbeke, D., Bailey, D., Townsend, D., Maisey, M.: Positron Emission Tomography: Clinical Practice. Springer (2006) Valk, P., Delbeke, D., Bailey, D., Townsend, D., Maisey, M.: Positron Emission Tomography: Clinical Practice. Springer (2006)
76.
go back to reference Varrone, A., Sjöholm, N., Eriksson, L., Gulyás, B., Halldin, C., Farde, L.: Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT. Eur. J. Nucl. Med. Mol. Imaging 36(10), 1639–1650 (2009)CrossRef Varrone, A., Sjöholm, N., Eriksson, L., Gulyás, B., Halldin, C., Farde, L.: Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT. Eur. J. Nucl. Med. Mol. Imaging 36(10), 1639–1650 (2009)CrossRef
77.
go back to reference Wahl, R.L., Buchanan, J.W.: Principles and Practice of Positron Emission Tomography. Lippincott Williams & Wilkins (2002) Wahl, R.L., Buchanan, J.W.: Principles and Practice of Positron Emission Tomography. Lippincott Williams & Wilkins (2002)
78.
go back to reference Wahl, R.L., Quint, L.E., Cieslak, R.D., Aisen, A.M., Koeppe, R.A., Meyer, C.R., et al.: Anatometabolic tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. J. Nucl. Med. 34(7), 1190 (1993) Wahl, R.L., Quint, L.E., Cieslak, R.D., Aisen, A.M., Koeppe, R.A., Meyer, C.R., et al.: Anatometabolic tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. J. Nucl. Med. 34(7), 1190 (1993)
79.
go back to reference Wang, G., Qi, J.: Generalized algorithms for direct reconstruction of parametric images from dynamic PET data. IEEE Trans. Med. Imaging 28(11), 1717–1726 (2009)CrossRef Wang, G., Qi, J.: Generalized algorithms for direct reconstruction of parametric images from dynamic PET data. IEEE Trans. Med. Imaging 28(11), 1717–1726 (2009)CrossRef
80.
go back to reference Watson, C.C.: New, faster, image-based scatter correction for 3D PET. IEEE Trans. Nucl. Sci. 47(4), 1587–1594 (2000)CrossRef Watson, C.C.: New, faster, image-based scatter correction for 3D PET. IEEE Trans. Nucl. Sci. 47(4), 1587–1594 (2000)CrossRef
81.
go back to reference Willmann, J.K., Van Bruggen, N., Dinkelborg, L.M., Gambhir, S.S.: Molecular imaging in drug development. Nat. Rev. Drug Discov. 7(7), 591–607 (2008)CrossRef Willmann, J.K., Van Bruggen, N., Dinkelborg, L.M., Gambhir, S.S.: Molecular imaging in drug development. Nat. Rev. Drug Discov. 7(7), 591–607 (2008)CrossRef
82.
go back to reference Wong, K.P., Feng, D., Meikle, S.R., Fulham, M.J.: Segmentation of dynamic PET images using cluster analysis. IEEE Trans. Nucl. Sci. 49(1), 200–207 (2002)CrossRef Wong, K.P., Feng, D., Meikle, S.R., Fulham, M.J.: Segmentation of dynamic PET images using cluster analysis. IEEE Trans. Nucl. Sci. 49(1), 200–207 (2002)CrossRef
83.
go back to reference Yan, J., Planeta-Wilson, B., Gallezot, J., Carson, R.: Initial evaluation of direct 4D parametric reconstruction with human PET data. In: Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE, pp. 2503–2506. IEEE (2010) Yan, J., Planeta-Wilson, B., Gallezot, J., Carson, R.: Initial evaluation of direct 4D parametric reconstruction with human PET data. In: Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE, pp. 2503–2506. IEEE (2010)
84.
go back to reference Yang, D.J., Azhdarinia, A., Kim, E.E.: Tumor specific imaging using Tc-99m and Ga-68 labeled radiopharmaceuticals. Curr. Med. Imaging Rev. 1(1), 25–34 (2005)CrossRef Yang, D.J., Azhdarinia, A., Kim, E.E.: Tumor specific imaging using Tc-99m and Ga-68 labeled radiopharmaceuticals. Curr. Med. Imaging Rev. 1(1), 25–34 (2005)CrossRef
85.
go back to reference Yang, J., Staib, L.H., Duncan, J.S.: Neighbor-constrained segmentation with level set based 3-D deformable models. IEEE Trans. Med. Imaging 23(8), 940–948 (2004)CrossRef Yang, J., Staib, L.H., Duncan, J.S.: Neighbor-constrained segmentation with level set based 3-D deformable models. IEEE Trans. Med. Imaging 23(8), 940–948 (2004)CrossRef
86.
go back to reference Yavuz, M., Fessler, J.A.: Statistical image reconstruction methods for randoms-precorrected pet scans. Med. Image Anal. 2(4), 369–378 (1998)CrossRef Yavuz, M., Fessler, J.A.: Statistical image reconstruction methods for randoms-precorrected pet scans. Med. Image Anal. 2(4), 369–378 (1998)CrossRef
87.
go back to reference Zaidi, H., El Naqa, I.: PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur. J. Nucl. Med. Mol. Imaging 37, 2165–2187 (2010)CrossRef Zaidi, H., El Naqa, I.: PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur. J. Nucl. Med. Mol. Imaging 37, 2165–2187 (2010)CrossRef
Metadata
Title
Computational Methods for Molecular Imaging
Authors
Fei Gao
Pengcheng Shi
Copyright Year
2015
DOI
https://doi.org/10.1007/978-3-319-18431-9_1