Skip to main content
Top
Published in: Microsystem Technologies 9/2016

04-09-2015 | Technical Paper

Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery

Authors: Jian Guo, Shuxiang Guo, Lin Shao, Peng Wang, Qiang Gao

Published in: Microsystem Technologies | Issue 9/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Vascular interventional surgery (VIS) is an effective treatment method for vascular diseases. However, there are many problems in traditional VIS, such as surgeons are radiated by X-ray, the lack of well skilled surgeons, the security of the surgery will be reduced due to the Surgeons’ fatigue, high risk of the surgery. To solve these problems, a robotic catheter system is needed to protect the surgeons and enhance the safety of the surgery. In this paper, a novel robotic catheter system with master–slave structure for VIS has been developed. This system is designed with the consideration of the operation method in traditional VIS, which allows the surgeon to operate a real catheter on the master side, then the surgeon make full use of the natural catheter manipulation experience and skills obtained in conventional catheter operation. The salve manipulator operates the catheter insert into the blood vessel with following the operation of the surgeon, and the operating force of the salve manipulator is detected. On the master side, a novel damper-based magnetorheological (MR) fluid is designed to realize the force feedback, which is also used to reappear the operation force from the salve manipulator. The damper connected directly with real catheter is a piston structure using the MR fluid to realize the force feedback. It can transmit the feedback force to surgeon’s hand through the operating catheter connected with damper, which seems that the surgeon operates the catheter beside the patient. The operating transparency of the developed system has been enhanced. The mechanism of the developed system has been introduced in detail. Performance evaluation experiments for the developed robotic catheter system have been done. The experimental results indicated that the developed robotic catheter system is fit for VIS.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Antoniou GA, Riga CV, Mayer EK, Cheshire NJW, Bicknell CD (2011) Clinical applications of robotic technology in vascular and endovascular surgery. J Vasc Surg 53(2):493–499CrossRef Antoniou GA, Riga CV, Mayer EK, Cheshire NJW, Bicknell CD (2011) Clinical applications of robotic technology in vascular and endovascular surgery. J Vasc Surg 53(2):493–499CrossRef
go back to reference Cao T, Wang D, Liu D, Zeng Y (2014) Master–slave remote controlled vascular interventional robot. J Northeast Univ (Nat Sci) 35(4):569–573 Cao T, Wang D, Liu D, Zeng Y (2014) Master–slave remote controlled vascular interventional robot. J Northeast Univ (Nat Sci) 35(4):569–573
go back to reference Feng W, Chi C, Wang H, Wang K, Ye X, Guo S (2006) Highly precise catheter driving mechanism for intravascular neurosurgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 990–995 Feng W, Chi C, Wang H, Wang K, Ye X, Guo S (2006) Highly precise catheter driving mechanism for intravascular neurosurgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 990–995
go back to reference Fu Y, Gao A, Liu H, Guo S (2011a) The master–slave catheterisation system for positioning the steerable catheter. Int J Mechatron Autom 1:143–152CrossRef Fu Y, Gao A, Liu H, Guo S (2011a) The master–slave catheterisation system for positioning the steerable catheter. Int J Mechatron Autom 1:143–152CrossRef
go back to reference Fu Y, Gao A, Liu H, Li K, Liang Z (2011b) Development of a novel robotic catheter system for endovascular minimally invasive surgery. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 400–405 Fu Y, Gao A, Liu H, Li K, Liang Z (2011b) Development of a novel robotic catheter system for endovascular minimally invasive surgery. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 400–405
go back to reference Gomes P (2011) Surgical robotics: reviewing the past, analyzing the present, imagining the future. Robot Comput Integr Manuf 27:261–266CrossRef Gomes P (2011) Surgical robotics: reviewing the past, analyzing the present, imagining the future. Robot Comput Integr Manuf 27:261–266CrossRef
go back to reference Guo J, Guo S, Xiao N, Ma X, Yoshida S, Tamiya T, Kawanishi M (2012) A novel robotic catheter system with force and visual feedback for vascular interventional surgery. Int J Mechatron Autom 2(1):15–24CrossRef Guo J, Guo S, Xiao N, Ma X, Yoshida S, Tamiya T, Kawanishi M (2012) A novel robotic catheter system with force and visual feedback for vascular interventional surgery. Int J Mechatron Autom 2(1):15–24CrossRef
go back to reference Guo J, Guo S, Wang P, Wei W, Wang Y (2013) a novel type of catheter sidewall tactile sensor array for vascular interventional surgery. In: Proceedings of IEEE international conference on complex medical engineering, pp 264–267 Guo J, Guo S, Wang P, Wei W, Wang Y (2013) a novel type of catheter sidewall tactile sensor array for vascular interventional surgery. In: Proceedings of IEEE international conference on complex medical engineering, pp 264–267
go back to reference Kasemi B, Muthalif AGA, Rashid MM, Rahman M (2011) Optimizing dynamic range of magnetorheological fluid dampers: modeling and simulation. In: 4th international conference on mechatronics, pp 1–4 Kasemi B, Muthalif AGA, Rashid MM, Rahman M (2011) Optimizing dynamic range of magnetorheological fluid dampers: modeling and simulation. In: 4th international conference on mechatronics, pp 1–4
go back to reference Kesner SB, Howe RD (2011) Force control of flexible catheter robots for beating heart surgery. In: 2011 IEEE international conference on robotics and automation, pp 1589–1594 Kesner SB, Howe RD (2011) Force control of flexible catheter robots for beating heart surgery. In: 2011 IEEE international conference on robotics and automation, pp 1589–1594
go back to reference Kim KP, Miller DL, Berrington GA, Balter S, Kleinerman RA, Ostroumova E, Simon SL, Linet MS (2012) Occupational radiation doses to operators performing fluoroscopically-guided procedures. Health Phys 103(1):80–99CrossRef Kim KP, Miller DL, Berrington GA, Balter S, Kleinerman RA, Ostroumova E, Simon SL, Linet MS (2012) Occupational radiation doses to operators performing fluoroscopically-guided procedures. Health Phys 103(1):80–99CrossRef
go back to reference Li S, Shen J, Yan Y, Chen D (2013) Overview of the vascular interventional surgery robot. Chin J Med Instrum 37(2):119–122 Li S, Shen J, Yan Y, Chen D (2013) Overview of the vascular interventional surgery robot. Chin J Med Instrum 37(2):119–122
go back to reference Liu B, Bai X, Meng C, Lv S, Zhou F (2011) Image-guided navigation system for robot-based vessel intervention surgery based on conventional single plane C-arm. Proc Environ Sci 8:276–283CrossRef Liu B, Bai X, Meng C, Lv S, Zhou F (2011) Image-guided navigation system for robot-based vessel intervention surgery based on conventional single plane C-arm. Proc Environ Sci 8:276–283CrossRef
go back to reference Lu W, Wang D, Liu D, Tian Z, Gao B, Zhang L (2013) Regarding application of robotic telemanipulation system in vascular interventional surgery. J Vasc Surg 57(5):1452–1453CrossRef Lu W, Wang D, Liu D, Tian Z, Gao B, Zhang L (2013) Regarding application of robotic telemanipulation system in vascular interventional surgery. J Vasc Surg 57(5):1452–1453CrossRef
go back to reference Mohapatra A, Greenberg RK, Mastracci TM, Eagleton MJ, Thornsberry B (2013) Radiation exposure to operating room personnel and patients during endovascular procedures. J Vasc Surg 58(3):702–709CrossRef Mohapatra A, Greenberg RK, Mastracci TM, Eagleton MJ, Thornsberry B (2013) Radiation exposure to operating room personnel and patients during endovascular procedures. J Vasc Surg 58(3):702–709CrossRef
go back to reference Park JW, Choi J, Pak HN, Song SJ, Lee JC, Park Y, Shin SM, Sun K (2010) Development of a force-reflecting robotic platform for cardiac catheter navigation. Artif Organs 34(11):1034–1039CrossRef Park JW, Choi J, Pak HN, Song SJ, Lee JC, Park Y, Shin SM, Sun K (2010) Development of a force-reflecting robotic platform for cardiac catheter navigation. Artif Organs 34(11):1034–1039CrossRef
go back to reference Payne CJ, Rafii-Tari H, Yang G (2012) A force feedback system for endovascular catheterisation. In: Proceedings of IEEE/RSJ international conference on IROS, pp 1298–1304 Payne CJ, Rafii-Tari H, Yang G (2012) A force feedback system for endovascular catheterisation. In: Proceedings of IEEE/RSJ international conference on IROS, pp 1298–1304
go back to reference Simorov A, Otte RS, Kopietz CM, Oleynikov D (2012) Review of surgical robotics user interface: what is the best way to control robotic surgery. Surg Endosc 26:2117–2125CrossRef Simorov A, Otte RS, Kopietz CM, Oleynikov D (2012) Review of surgical robotics user interface: what is the best way to control robotic surgery. Surg Endosc 26:2117–2125CrossRef
go back to reference Srimathveeravalli G, Kesavadas T, Li X (2010) Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices. Int J Med Robot Comput Assist Surg 6:160–170 Srimathveeravalli G, Kesavadas T, Li X (2010) Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices. Int J Med Robot Comput Assist Surg 6:160–170
go back to reference Tanimoto M, Arai F, Fukuda T, Itoigawa K, Hashimoto M, Takahashi I, Negoro M (2000) Telesurgery system for intravascular neurosurgery. In: Medical image computing and computer-assisted intervention—MICCAI, pp 29–39 Tanimoto M, Arai F, Fukuda T, Itoigawa K, Hashimoto M, Takahashi I, Negoro M (2000) Telesurgery system for intravascular neurosurgery. In: Medical image computing and computer-assisted intervention—MICCAI, pp 29–39
go back to reference Tercero CR, Najdovski Z, Ikeda S, Nahavandi S, Fukuda T (2013) Haptic feedback in endovascular tele-surgery simulation through vasculature phantom morphology changes. In: IEEE world haptics conference, pp 359–364 Tercero CR, Najdovski Z, Ikeda S, Nahavandi S, Fukuda T (2013) Haptic feedback in endovascular tele-surgery simulation through vasculature phantom morphology changes. In: IEEE world haptics conference, pp 359–364
go back to reference Zakaria NA, Komeda T, Low CY, Makoto M, Kobayashi M, Ismail AY, Dumitrescu R (2013) Development of foolproof catheter guide system based on mechatronic design. Prod Eng Res Dev 7:81–90CrossRef Zakaria NA, Komeda T, Low CY, Makoto M, Kobayashi M, Ismail AY, Dumitrescu R (2013) Development of foolproof catheter guide system based on mechatronic design. Prod Eng Res Dev 7:81–90CrossRef
go back to reference Zhang P, Yu SC, Hu Y, Ma X, Zhang JW (2011) Design of a novel master–slave robotic system for minimally intravascular invasive surgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 259–264 Zhang P, Yu SC, Hu Y, Ma X, Zhang JW (2011) Design of a novel master–slave robotic system for minimally intravascular invasive surgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 259–264
go back to reference Zhao H, Duan X (2011) Design of a catheter operating system with active supporting arm for vascular interventional surgery. In: 2011 third international conference on intelligent human–machine systems and cybernetics, pp 169–172 Zhao H, Duan X (2011) Design of a catheter operating system with active supporting arm for vascular interventional surgery. In: 2011 third international conference on intelligent human–machine systems and cybernetics, pp 169–172
go back to reference Zhao H, Duan X, Huang Q, Wang X, Chen Y, Yu H (2011) Mechanical design and control system of vascular interventional robot. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 357–362 Zhao H, Duan X, Huang Q, Wang X, Chen Y, Yu H (2011) Mechanical design and control system of vascular interventional robot. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 357–362
Metadata
Title
Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery
Authors
Jian Guo
Shuxiang Guo
Lin Shao
Peng Wang
Qiang Gao
Publication date
04-09-2015
Publisher
Springer Berlin Heidelberg
Published in
Microsystem Technologies / Issue 9/2016
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-015-2659-4

Other articles of this Issue 9/2016

Microsystem Technologies 9/2016 Go to the issue