Skip to main content
Top

2022 | OriginalPaper | Chapter

Design of a Circular Ring Slot Patch Antenna at 2.45 GHz for Hyperthermia Applications

Authors : Abhijeet Singh, Pushpendra Singh, S. P. Singh

Published in: Mathematical, Computational Intelligence and Engineering Approaches for Tourism, Agriculture and Healthcare

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Hyperthermia plays an important role in the treatment of cancer. A circular ring slot patch antenna for Hyperthermia applications is presented at 2.45 GHz. The proposed antenna shows return loss without significant detuning or impedance mismatch with different positions concerning a phantom muscle model. The simulation study is done by a Finite Element Method (FEM) based on Ansoft’s HFSS software. The antenna penetration depth, return loss, and the specific absorption rate (SAR) pattern are evaluated for various antenna orientations concerning the phantom muscle model.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Bolomey, J.C.: Recent European developments in active microwave imaging for industrial, scientific, and medical applications. IEEE Trans. Microw. Theory Tech. 37(12), 2109–2117 (1989) Bolomey, J.C.: Recent European developments in active microwave imaging for industrial, scientific, and medical applications. IEEE Trans. Microw. Theory Tech. 37(12), 2109–2117 (1989)
2.
go back to reference Meaney, P.M., Paulsen, K.D., Hartov, A., Crane, R.K.: Microwave imaging for tissue assessment: initial evaluation in multi target tissue-equivalent phantoms. IEEE Trans. Biomed. Eng. 43(9), 878–890 (1996) Meaney, P.M., Paulsen, K.D., Hartov, A., Crane, R.K.: Microwave imaging for tissue assessment: initial evaluation in multi target tissue-equivalent phantoms. IEEE Trans. Biomed. Eng. 43(9), 878–890 (1996)
3.
go back to reference Singh, S., Sahu, B., Singh, S.P.: Hyperthermia performance of conformal applicator for limb tumor in presence of water bolus. In: International Symposium on Antennas and Propagation (ISAP), pp. 1–2 (2017) Singh, S., Sahu, B., Singh, S.P.: Hyperthermia performance of conformal applicator for limb tumor in presence of water bolus. In: International Symposium on Antennas and Propagation (ISAP), pp. 1–2 (2017)
4.
go back to reference Planche, K., Vinnicombe, S.: Breast imaging in the new era. Cancer Imaging 4, 39–50 (2004) Planche, K., Vinnicombe, S.: Breast imaging in the new era. Cancer Imaging 4, 39–50 (2004)
5.
go back to reference Singh, S., Sahu, B., Singh, S.P.: Bi-layered/tri-layered bio-media in direct contact with metal diagonal horn for hyperthermia. Int. J. Microw. Wirel. Technol. 10(8), (2018) Singh, S., Sahu, B., Singh, S.P.: Bi-layered/tri-layered bio-media in direct contact with metal diagonal horn for hyperthermia. Int. J. Microw. Wirel. Technol. 10(8), (2018)
6.
go back to reference Singh, S., Singh, S.P.: Microstrip slot antenna for hyperthermia applications. In: 2015 IEEE Applied Electromagnetics Conference (AEMC), pp. 1–2 (2015) Singh, S., Singh, S.P.: Microstrip slot antenna for hyperthermia applications. In: 2015 IEEE Applied Electromagnetics Conference (AEMC), pp. 1–2 (2015)
7.
go back to reference Munson, R.E.: Conformal microstrip antennas and microstrip phased arrays. IEEE Trans. Antennas Propag. AP-22, 74–78 (1974) Munson, R.E.: Conformal microstrip antennas and microstrip phased arrays. IEEE Trans. Antennas Propag. AP-22, 74–78 (1974)
8.
go back to reference Mendecki, J., Friedenthal, E., Botstein, C., Sterzer, F., Paglione, R.: Therapeutic potential of conformal applicators for induction of hyperthermia. J. Microw. Power 14, 139–144 (1979) Mendecki, J., Friedenthal, E., Botstein, C., Sterzer, F., Paglione, R.: Therapeutic potential of conformal applicators for induction of hyperthermia. J. Microw. Power 14, 139–144 (1979)
9.
go back to reference Bahl, I.J., Stuchly, S.S., Lagendijk, J.J., Stuchly, M.A.: Microstrip loop radiators for medical applications. IEEE Trans. Microw. Theory Tech. MTT-30, 1090–1093 (1982) Bahl, I.J., Stuchly, S.S., Lagendijk, J.J., Stuchly, M.A.: Microstrip loop radiators for medical applications. IEEE Trans. Microw. Theory Tech. MTT-30, 1090–1093 (1982)
10.
go back to reference Kapp, D.S., Fessenden, P., Samulski, T.V., Bagshaw, M.A., Cox, R.S., Lee, E.R., Lohrbach, A.W., Meyer, J.L., Prionas, S.D.: Stanford university institutional report, phase 1 evaluation of equipment for hyperthermia treatment of cancer. Int. J. Hyperth. 4(1), 75–115 (1988) Kapp, D.S., Fessenden, P., Samulski, T.V., Bagshaw, M.A., Cox, R.S., Lee, E.R., Lohrbach, A.W., Meyer, J.L., Prionas, S.D.: Stanford university institutional report, phase 1 evaluation of equipment for hyperthermia treatment of cancer. Int. J. Hyperth. 4(1), 75–115 (1988)
11.
go back to reference Curto, S., McEvoy, P., Bao, X., Ammann, M.J.: Compact patch antenna for electromagnetic interaction with human tissue at 434 MHz. IEEE Trans. Antennas Propag. 57(9) (2009) Curto, S., McEvoy, P., Bao, X., Ammann, M.J.: Compact patch antenna for electromagnetic interaction with human tissue at 434 MHz. IEEE Trans. Antennas Propag. 57(9) (2009)
12.
go back to reference Gupta, R.C., Singh, S.P.: Analysis of the SAR distributions in three layered bio-media in direct contact with a water-loaded modified box-horn applicator. IEEE Trans. Microw. Theory Tech. 53(9), 2665–2671 (2005) Gupta, R.C., Singh, S.P.: Analysis of the SAR distributions in three layered bio-media in direct contact with a water-loaded modified box-horn applicator. IEEE Trans. Microw. Theory Tech. 53(9), 2665–2671 (2005)
Metadata
Title
Design of a Circular Ring Slot Patch Antenna at 2.45 GHz for Hyperthermia Applications
Authors
Abhijeet Singh
Pushpendra Singh
S. P. Singh
Copyright Year
2022
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-3807-7_24

Premium Partners