Diagnostic tool functions of the original fault diagnostic system in direct current (DC) converter stations are not concentrated, and it is unable to accurately diagnose the exceptions of different layers. In order to ensure rapid and accurate location of the host events and the server faults, the real-time diagnosis software for high-voltage direct current (HVDC) converter station control and protection system is designed. The NetDDE technology tracks the suspicious analogy and variables of the switch state using the software interface of MACH2 system, which has been implemented to analyze the exception of the state variable and locate the host fault by recalling the historical data. By calling the stored procedure of SQL server, exceptions can be tracked in a real-time manner by means of the returned data column information. The host and the server exceptions can be rapidly and effectively monitored, tracked, and located by the system. It can also reduce the time of dealing with complex defects and increase the reliability of the whole control and protection system. The system does not affect normal operation of the original system.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Dai D. Detention method of MACH2 based system of event flow. Hubei Electr Power. 2011;35(6):18–20. Dai D. Detention method of MACH2 based system of event flow. Hubei Electr Power. 2011;35(6):18–20.
2.
go back to reference Shen Z. Application of MACH2 system in HVDC transmission project. High Volt Eng. 2006;32(9):46–9. Shen Z. Application of MACH2 system in HVDC transmission project. High Volt Eng. 2006;32(9):46–9.
3.
go back to reference LI F. Analysis of control and protection software of high voltage DC transmission system. Shanghai: Shanghai Jiao Tong University; 2006. LI F. Analysis of control and protection software of high voltage DC transmission system. Shanghai: Shanghai Jiao Tong University; 2006.
4.
go back to reference Tian J. Design and realization of HVDC. Control Prot Syst Electr Power Autom Equip. 2005;25(9):10–4. Tian J. Design and realization of HVDC. Control Prot Syst Electr Power Autom Equip. 2005;25(9):10–4.
5.
go back to reference He H. Application of NetDDE in the automatic network. Microcomput Inf. 2002;6(18):54–7. He H. Application of NetDDE in the automatic network. Microcomput Inf. 2002;6(18):54–7.
6.
go back to reference Zhang J. Method to solve the communication of different configuration software based on NetDDE. Technol Gansu Sci Technol. 2010;26(16):30–337. Zhang J. Method to solve the communication of different configuration software based on NetDDE. Technol Gansu Sci Technol. 2010;26(16):30–337.
7.
go back to reference Wang L. DDE dynamic data exchange technology in measurement experiment. Metrol Measurement Tech. 2009;36(10):19–20. Wang L. DDE dynamic data exchange technology in measurement experiment. Metrol Measurement Tech. 2009;36(10):19–20.
8.
go back to reference Wang J. The application of power monitoring & controlling system based on InTouch. Tianjin: Tianjin University; 2008. Wang J. The application of power monitoring & controlling system based on InTouch. Tianjin: Tianjin University; 2008.
9.
go back to reference Li G. Analysis of dynamic modifications to the INI file. Softw Guide. 2011;10(6):26–7. Li G. Analysis of dynamic modifications to the INI file. Softw Guide. 2011;10(6):26–7.
10.
go back to reference Zhou G. Design and implementation of data in SQL Server database operation tracking system Fujian Computer. Technol Gansu Sci Technol. 2005;23(4):60–2. Zhou G. Design and implementation of data in SQL Server database operation tracking system Fujian Computer. Technol Gansu Sci Technol. 2005;23(4):60–2.
11.
go back to reference Sun Q. Effect of SQL profiler in database optimization. Comput Program Skills Maint. 2009;12(4):72–4. Sun Q. Effect of SQL profiler in database optimization. Comput Program Skills Maint. 2009;12(4):72–4.
12.
go back to reference Kelly AJ. SQL server profiler or server-side trace. SQL Serv Mag. 2006;14(2):7–8. Kelly AJ. SQL server profiler or server-side trace. SQL Serv Mag. 2006;14(2):7–8.
Metadata
Title
Design of Real-Time Tracking System on High-Voltage Direct Current Converter Station Control and Protection System
Authors
Wei Hao
Chengjiang Wang
Ming Li
Qingyun Liang
Copyright Year
2015
DOI
https://doi.org/10.1007/978-3-319-13707-0_36