Skip to main content
Top

2019 | OriginalPaper | Chapter

Diffusion MRI Outside the Brain

Authors : Rita G. Nunes, Luísa Nogueira, Andreia S. Gaspar, Nuno Adubeiro, Sofia Brandão

Published in: Computational Diffusion MRI

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This manuscript provides an overview of recent developments in Diffusion-Weighted Imaging (DWI) outside the brain, focusing on liver, breast, prostate, muskuloskeletal (MSK) and cardiac applications. A general introduction to cross-cutting acquisition and image processing challenges is first provided. These often include short \(T_2\) relaxation times, the need to image a large field-of-view with the resulting complications in shimming the B0 field and achieving good fat suppression. Some of the strategies developed for dealing with motion, namely cardiac and respiratory motion are described. Specific sections are then presented for each of the aforementioned organs. A motivation for the clinical applicability of DWI is first provided, followed by specific image acquisition and processing considerations. Quantitative imaging is becoming standard in clinical practice, and the Apparent Diffusion Coefficient is routinely estimated in the liver, breast and prostate. Application of alternative signal models in these organs is being explored, including both the Intravoxel Incoherent Motion and Diffusion Kurtosis models. Ongoing efforts are focused on evaluating the potential clinical added value of the extra parameters and on improving their repeatability. MSK and cardiac DWI have shown potential for assessing pathological changes in fiber architecture, but further validation is required to enable application in the clinical setting.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Aliotta, E., Wu, H.H., Ennis, D.B.: Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI. Magn. Reson. Med. 77(2), 717–729 (2017) Aliotta, E., Wu, H.H., Ennis, D.B.: Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI. Magn. Reson. Med. 77(2), 717–729 (2017)
2.
go back to reference Anderson, A.W., Gore, J.C.: Analysis and correction of motion artifacts in diffusion weighted imaging. Magn. Reson. Med. 32(3), 379–87 (1994) Anderson, A.W., Gore, J.C.: Analysis and correction of motion artifacts in diffusion weighted imaging. Magn. Reson. Med. 32(3), 379–87 (1994)
3.
go back to reference Baliyan, V., Kordbacheh, H., Kambadakone, A., Guimaraes, A.R., Shenoy-Bhangle, A.: Diffusion weighted magnetic resonance imaging of liver: principles, clinical applications and recent updates. World J. Hepatol. 9(926), 1081–1091 (2017) Baliyan, V., Kordbacheh, H., Kambadakone, A., Guimaraes, A.R., Shenoy-Bhangle, A.: Diffusion weighted magnetic resonance imaging of liver: principles, clinical applications and recent updates. World J. Hepatol. 9(926), 1081–1091 (2017)
4.
go back to reference Barentsz, M.W., Taviani, V., Chang, J.M., Ikeda, D.M., Miyake, K.K., Banerjee, S., van den Bosch, M.A.A.J., Hargreaves, B.A., Daniel, B.L.: Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: diagnostic value of reduced field of view DWI. J. Magn. Reson. Imaging 42(6), 1656–1665 (2015) Barentsz, M.W., Taviani, V., Chang, J.M., Ikeda, D.M., Miyake, K.K., Banerjee, S., van den Bosch, M.A.A.J., Hargreaves, B.A., Daniel, B.L.: Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: diagnostic value of reduced field of view DWI. J. Magn. Reson. Imaging 42(6), 1656–1665 (2015)
5.
go back to reference Bokacheva, L., Kaplan, J.B., Giri, D.D., Patil, S., Gnanasigamani, M., Nyman, C.G., Deasy, J.O., Morris, E.A., Thakur, S.B.: Intravoxel incoherent motion diffusion-weighted MRI at 3.0 T differentiates malignant breast lesions from benign lesions and breast parenchyma. J. Magn. Reson. Imaging 40(4), 813–823 (2014) Bokacheva, L., Kaplan, J.B., Giri, D.D., Patil, S., Gnanasigamani, M., Nyman, C.G., Deasy, J.O., Morris, E.A., Thakur, S.B.: Intravoxel incoherent motion diffusion-weighted MRI at 3.0 T differentiates malignant breast lesions from benign lesions and breast parenchyma. J. Magn. Reson. Imaging 40(4), 813–823 (2014)
8.
go back to reference Burakiewicz, J., Hooijmans, M.T., Webb, A.G., Verschuuren, J.J.G.M., Niks, E.H., Kan, H.E.: Improved olefinic fat suppression in skeletal muscle DTI using a magnitude-based dixon method. Magn. Reson. Med. 79(1), 152–159 (2018) Burakiewicz, J., Hooijmans, M.T., Webb, A.G., Verschuuren, J.J.G.M., Niks, E.H., Kan, H.E.: Improved olefinic fat suppression in skeletal muscle DTI using a magnitude-based dixon method. Magn. Reson. Med. 79(1), 152–159 (2018)
9.
go back to reference Cakir, O., Arslan, A., Inan, N., Anik, Y., Sarisoy, T., Gumustas, S., Akansel, G.: Comparison of the diagnostic performances of diffusion parameters in diffusion weighted imaging and diffusion tensor imaging of breast lesions. Eur. J. Radiol. 82(12), 801–806 (2013) Cakir, O., Arslan, A., Inan, N., Anik, Y., Sarisoy, T., Gumustas, S., Akansel, G.: Comparison of the diagnostic performances of diffusion parameters in diffusion weighted imaging and diffusion tensor imaging of breast lesions. Eur. J. Radiol. 82(12), 801–806 (2013)
10.
go back to reference Chevallier, O., Zhou, N., He, J., Loffroy, R., Xiáng, Y., Wáng, J.: Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan-rescan reproducibility. Acta Radiologica p. [Epub ahead of print] (2018). https://doi.org/10.1177/0284185118756949 Chevallier, O., Zhou, N., He, J., Loffroy, R., Xiáng, Y., Wáng, J.: Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan-rescan reproducibility. Acta Radiologica p. [Epub ahead of print] (2018). https://​doi.​org/​10.​1177/​0284185118756949​
11.
go back to reference Choi, J.S.Y., Kim, M.J., Chung, Y.E., Kim, K.A.K.W., Lim, J.S., Park, M.S.: Comparison of breathhold, navigator-triggered, and free-breathing diffusion-weighted MRI for focal hepatic lesions. J. Magn. Reson. Imaging 38(1), 109–118 (2013) Choi, J.S.Y., Kim, M.J., Chung, Y.E., Kim, K.A.K.W., Lim, J.S., Park, M.S.: Comparison of breathhold, navigator-triggered, and free-breathing diffusion-weighted MRI for focal hepatic lesions. J. Magn. Reson. Imaging 38(1), 109–118 (2013)
12.
go back to reference Coelho-Filho, O.R., Rickers, C., Kwong, R.Y., Jerosch-Herold, M.: MR myocardial perfusion imaging. Radiology 266(3), 701–715 (2013) Coelho-Filho, O.R., Rickers, C., Kwong, R.Y., Jerosch-Herold, M.: MR myocardial perfusion imaging. Radiology 266(3), 701–715 (2013)
14.
go back to reference Delattre, B.M.A., Viallon, M., Wei, H., Zhu, Y.M., Feiweier, T., Pai, V.M., Wen, H., Croisille, P.: In vivo cardiac diffusion-weighted magnetic resonance imaging: quantification of normal perfusion and diffusion coefficients with intravoxel incoherent motion imaging. Investig. Radiol. 47(11), 662–670 (2012) Delattre, B.M.A., Viallon, M., Wei, H., Zhu, Y.M., Feiweier, T., Pai, V.M., Wen, H., Croisille, P.: In vivo cardiac diffusion-weighted magnetic resonance imaging: quantification of normal perfusion and diffusion coefficients with intravoxel incoherent motion imaging. Investig. Radiol. 47(11), 662–670 (2012)
15.
go back to reference Donati, O.F., Mazaheri, Y., Afaq, A., Vargas, H.A., Zheng, J., Moskowitz, C.S., Hricak, H., Akin, O.: Prostate cancer aggressiveness: assessment with whole-lesion histogram analysis of the apparent diffusion coefficient. Radiology 271(1), 143–152 (2014) Donati, O.F., Mazaheri, Y., Afaq, A., Vargas, H.A., Zheng, J., Moskowitz, C.S., Hricak, H., Akin, O.: Prostate cancer aggressiveness: assessment with whole-lesion histogram analysis of the apparent diffusion coefficient. Radiology 271(1), 143–152 (2014)
16.
go back to reference Dong, H., Li, Y., Yu, K., Li, H.: Comparison of image quality and application values on different field-of-view diffusion-weighted imaging of breast cancer. Acta Radiol. 57(1), 19–24 (2016) Dong, H., Li, Y., Yu, K., Li, H.: Comparison of image quality and application values on different field-of-view diffusion-weighted imaging of breast cancer. Acta Radiol. 57(1), 19–24 (2016)
17.
go back to reference Edelman, R.R., Gaa, J., Wedeen, V.J., Loh, E., Hare, J.M., Prasad, P., Li, W.: In vivo measurement of water diffusion in the human heart. Mag. Reson. Med. 32(3), 423–428 (1994) Edelman, R.R., Gaa, J., Wedeen, V.J., Loh, E., Hare, J.M., Prasad, P., Li, W.: In vivo measurement of water diffusion in the human heart. Mag. Reson. Med. 32(3), 423–428 (1994)
18.
go back to reference Errante, Y., Cirimele, V., Mallio, C.A., Di Lazzaro, V., Zobel, B.B., Quattrocchi, C.C.: Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation. Investig. Radiol. 49(10), 685–690 (2014) Errante, Y., Cirimele, V., Mallio, C.A., Di Lazzaro, V., Zobel, B.B., Quattrocchi, C.C.: Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation. Investig. Radiol. 49(10), 685–690 (2014)
19.
go back to reference Eyal, E., Shapiro-Feinberg, M., Furman-Haran, E., Grobgeld, D., Golan, T., Itzchak, Y., Catane, R., Papa, M., Degani, H.: Parametric diffusion tensor imaging of the breast. Investig. Radiol. 47(5), 284–291 (2012) Eyal, E., Shapiro-Feinberg, M., Furman-Haran, E., Grobgeld, D., Golan, T., Itzchak, Y., Catane, R., Papa, M., Degani, H.: Parametric diffusion tensor imaging of the breast. Investig. Radiol. 47(5), 284–291 (2012)
20.
go back to reference Ferreira, P.F., Kilner, P.J., McGill, L.A., Nielles-Vallespin, S., Scott, A.D., Ho, S.Y., McCarthy, K.P., Haba, M.M., Ismail, T.F., Gatehouse, P.D., de Silva, R., Lyon, A.R., Prasad, S.K., Firmin, D.N., Pennell, D.J.: In vivo cardiovascular magnetic resonance diffusion tensor imaging shows evidence of abnormal myocardial laminar orientations and mobility in hypertrophic cardiomyopathy. J. Cardiovasc. Magn. Reson. 16(1), 87 (2014) Ferreira, P.F., Kilner, P.J., McGill, L.A., Nielles-Vallespin, S., Scott, A.D., Ho, S.Y., McCarthy, K.P., Haba, M.M., Ismail, T.F., Gatehouse, P.D., de Silva, R., Lyon, A.R., Prasad, S.K., Firmin, D.N., Pennell, D.J.: In vivo cardiovascular magnetic resonance diffusion tensor imaging shows evidence of abnormal myocardial laminar orientations and mobility in hypertrophic cardiomyopathy. J. Cardiovasc. Magn. Reson. 16(1), 87 (2014)
21.
go back to reference Fieremans, E., Lemberskiy, G., Veraart, J., Sigmund, E.E., Gyftopoulos, S., Novikov, D.S.: In vivo measurement of membrane permeability and myofiber size in human muscle using time-dependent diffusion tensor imaging and the random permeable barrier model. NMR in Biomed. 30(3), [Epub ahead of print] (2017). https://doi.org/10.1002/nbm.3612 Fieremans, E., Lemberskiy, G., Veraart, J., Sigmund, E.E., Gyftopoulos, S., Novikov, D.S.: In vivo measurement of membrane permeability and myofiber size in human muscle using time-dependent diffusion tensor imaging and the random permeable barrier model. NMR in Biomed. 30(3), [Epub ahead of print] (2017). https://​doi.​org/​10.​1002/​nbm.​3612
22.
go back to reference Filli, L., Ghafoor, S., Kenkel, D., Liu, W., Weiland, E., Andreisek, G., Frauenfelder, T., Runge, V.M., Boss, A.: Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast. Eur. J. Radiol. 85(1), 274–278 (2016) Filli, L., Ghafoor, S., Kenkel, D., Liu, W., Weiland, E., Andreisek, G., Frauenfelder, T., Runge, V.M., Boss, A.: Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast. Eur. J. Radiol. 85(1), 274–278 (2016)
23.
go back to reference Freiman, M., Perez-Rossello, J.M., Callahan, M.J., Voss, S.D., Ecklund, K., Mulkern, R.V., Warfield, S.K.: Reliable estimation of incoherent motion parametric maps from diffusion-weighted MRI using fusion bootstrap moves. Med. Image Anal. 17(3), 325–336 (2013) Freiman, M., Perez-Rossello, J.M., Callahan, M.J., Voss, S.D., Ecklund, K., Mulkern, R.V., Warfield, S.K.: Reliable estimation of incoherent motion parametric maps from diffusion-weighted MRI using fusion bootstrap moves. Med. Image Anal. 17(3), 325–336 (2013)
24.
go back to reference Froeling, M., Nederveen, A.J., Nicolay, K., Strijkers, G.J.: DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts. NMR in Biomed. 26(11), 1339–1352 (2013) Froeling, M., Nederveen, A.J., Nicolay, K., Strijkers, G.J.: DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts. NMR in Biomed. 26(11), 1339–1352 (2013)
25.
go back to reference Furman-Haran, E., Grobgeld, D., Nissan, N., Shapiro-Feinberg, M., Degani, H.: Can diffusion tensor anisotropy indices assist in breast cancer detection? J. Magn. Reson. Imaging 44(6), 1624–1632 (2016) Furman-Haran, E., Grobgeld, D., Nissan, N., Shapiro-Feinberg, M., Degani, H.: Can diffusion tensor anisotropy indices assist in breast cancer detection? J. Magn. Reson. Imaging 44(6), 1624–1632 (2016)
26.
go back to reference Galea, N., Cantisani, V., Taouli, B.: Liver lesion detection and characterization: Role of diffusion-weighted imaging. J. Magn. Reson. Imaging 37(6), 1260–1276 (2013) Galea, N., Cantisani, V., Taouli, B.: Liver lesion detection and characterization: Role of diffusion-weighted imaging. J. Magn. Reson. Imaging 37(6), 1260–1276 (2013)
27.
go back to reference Gamper, U., Boesiger, P., Kozerke, S.: Diffusion imaging of the in vivo heart using spin echoes-considerations on bulk motion sensitivity. J. Magn. Reson. Imaging 57(2), 331–337 (2007) Gamper, U., Boesiger, P., Kozerke, S.: Diffusion imaging of the in vivo heart using spin echoes-considerations on bulk motion sensitivity. J. Magn. Reson. Imaging 57(2), 331–337 (2007)
28.
go back to reference Giri, S., Chung, Y.C., Merchant, A., Mihai, G., Rajagopalan, S., Raman, S.V., Simonetti, O.P.: T2 quantification for improved detection of myocardial edema. J. Cardiovasc. Magn. Reson. 11(1), 56 (2009) Giri, S., Chung, Y.C., Merchant, A., Mihai, G., Rajagopalan, S., Raman, S.V., Simonetti, O.P.: T2 quantification for improved detection of myocardial edema. J. Cardiovasc. Magn. Reson. 11(1), 56 (2009)
29.
go back to reference Goshima, S., Kanematsu, M., Noda, Y., Kondo, H., Watanabe, H., Bae, K.T.: Diffusion kurtosis imaging to assess response to treatment in hypervascular hepatocellular carcinoma. AJR. Am. J. Roentgenol. 204(5), 543–9 (2015) Goshima, S., Kanematsu, M., Noda, Y., Kondo, H., Watanabe, H., Bae, K.T.: Diffusion kurtosis imaging to assess response to treatment in hypervascular hepatocellular carcinoma. AJR. Am. J. Roentgenol. 204(5), 543–9 (2015)
30.
go back to reference Grant, K.B., Agarwal, H.K., Shih, J.H., Bernardo, M., Pang, Y., Daar, D., Merino, M.J., Wood, B.J., Pinto, P.A., Choyke, P.L., Turkbey, B.: Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer. Abdom. Imaging 40(3), 578–586 (2015) Grant, K.B., Agarwal, H.K., Shih, J.H., Bernardo, M., Pang, Y., Daar, D., Merino, M.J., Wood, B.J., Pinto, P.A., Choyke, P.L., Turkbey, B.: Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer. Abdom. Imaging 40(3), 578–586 (2015)
31.
go back to reference Hata, J., Yagi, K., Hikishima, K., Numano, T., Goto, M., Yano, K.: Characteristics of diffusion-weighted stimulated echo pulse sequence in human skeletal muscle. Radiol. Phys. Technol. 6(1), 92–97 (2013) Hata, J., Yagi, K., Hikishima, K., Numano, T., Goto, M., Yano, K.: Characteristics of diffusion-weighted stimulated echo pulse sequence in human skeletal muscle. Radiol. Phys. Technol. 6(1), 92–97 (2013)
32.
go back to reference Hedgire, S., Tonyushkin, A., Kilcoyne, A., Efstathiou, J.A., Hahn, P.F., Harisinghani, M.: Quantitative study of prostate cancer using three dimensional fiber tractography. World J. Radiol. 8(4), 397–402 (2016) Hedgire, S., Tonyushkin, A., Kilcoyne, A., Efstathiou, J.A., Hahn, P.F., Harisinghani, M.: Quantitative study of prostate cancer using three dimensional fiber tractography. World J. Radiol. 8(4), 397–402 (2016)
33.
go back to reference Heemskerk, A.M., Damon, B.M.: Diffusion tensor MRI assessment of skeletal muscle architecture. Curr. Med. Imaging Rev. 3(3), 152–160 (2007) Heemskerk, A.M., Damon, B.M.: Diffusion tensor MRI assessment of skeletal muscle architecture. Curr. Med. Imaging Rev. 3(3), 152–160 (2007)
34.
go back to reference Heemskerk, A.M., Sinha, T.K., Wilson, K.J., Ding, Z., Damon, B.M.: Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magn. Reson. Med. 61(2), 467–472 (2009) Heemskerk, A.M., Sinha, T.K., Wilson, K.J., Ding, Z., Damon, B.M.: Quantitative assessment of DTI-based muscle fiber tracking and optimal tracking parameters. Magn. Reson. Med. 61(2), 467–472 (2009)
35.
go back to reference Hernando, D., Karampinos, D.C., King, K.F., Haldar, J.P., Majumdar, S., Georgiadis, J.G., Liang, Z.P.: Removal of olefinic fat chemical shift artifact in diffusion MRI. Magn. Reson. Med. 65(3), 692–701 (2011) Hernando, D., Karampinos, D.C., King, K.F., Haldar, J.P., Majumdar, S., Georgiadis, J.G., Liang, Z.P.: Removal of olefinic fat chemical shift artifact in diffusion MRI. Magn. Reson. Med. 65(3), 692–701 (2011)
36.
go back to reference Iima, M., Kataoka, M., Kanao, S., Onishi, N., Kawai, M., Ohashi, A., Sakaguchi, R., Toi, M., Togashi, K.: Intravoxel incoherent motion and quantitative non-gaussian diffusion MR imaging: evaluation of the diagnostic and prognostic value of several markers of malignant and benign breast lesions. Radiology 287(2), 432–441 (2018) Iima, M., Kataoka, M., Kanao, S., Onishi, N., Kawai, M., Ohashi, A., Sakaguchi, R., Toi, M., Togashi, K.: Intravoxel incoherent motion and quantitative non-gaussian diffusion MR imaging: evaluation of the diagnostic and prognostic value of several markers of malignant and benign breast lesions. Radiology 287(2), 432–441 (2018)
37.
go back to reference Iima, M., Yano, K., Kataoka, M., Umehana, M., Murata, K., Kanao, S., Togashi, K., Le Bihan, D.: Quantitative non-Gaussian diffusion and intravoxel incoherent motion magnetic resonance imaging: differentiation of malignant and benign breast lesions. Investig. Radiol. 50(4), 205–211 (2015) Iima, M., Yano, K., Kataoka, M., Umehana, M., Murata, K., Kanao, S., Togashi, K., Le Bihan, D.: Quantitative non-Gaussian diffusion and intravoxel incoherent motion magnetic resonance imaging: differentiation of malignant and benign breast lesions. Investig. Radiol. 50(4), 205–211 (2015)
38.
go back to reference Jafar, M.M., Parsai, A., Miquel, M.E.: Diffusion-weighted magnetic resonance imaging in cancer: reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility. World J. Radiol. 8(1), 21–49 (2016) Jafar, M.M., Parsai, A., Miquel, M.E.: Diffusion-weighted magnetic resonance imaging in cancer: reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility. World J. Radiol. 8(1), 21–49 (2016)
39.
go back to reference Jensen, J.H., Helpern, J.A., Ramani, A., Lu, H., Kaczynski, K.: Diffusional kurtosis imaging: The quantification of non-gaussian water diffusion by means of magnetic resonance imaging. Magn. Reson. Med. 53(6), 1432–1440 (2005) Jensen, J.H., Helpern, J.A., Ramani, A., Lu, H., Kaczynski, K.: Diffusional kurtosis imaging: The quantification of non-gaussian water diffusion by means of magnetic resonance imaging. Magn. Reson. Med. 53(6), 1432–1440 (2005)
40.
go back to reference Jie, C., Rongbo, L., Ping, T.: The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis. Eur. Radiol. 24(8), 1929–1941 (2014) Jie, C., Rongbo, L., Ping, T.: The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis. Eur. Radiol. 24(8), 1929–1941 (2014)
41.
go back to reference Jin, G., An, N., Jacobs, M.A., Li, K.: The role of parallel diffusion-weighted imaging and apparent diffusion coefficient (ADC) map values for evaluating breast lesions: preliminary results. Acad. Radiol. 17(4), 456–463 (2010) Jin, G., An, N., Jacobs, M.A., Li, K.: The role of parallel diffusion-weighted imaging and apparent diffusion coefficient (ADC) map values for evaluating breast lesions: preliminary results. Acad. Radiol. 17(4), 456–463 (2010)
42.
go back to reference Jones, D.K., Cercignani, M.: Twenty-five pitfalls in the analysis of diffusion MRI data. NMR Biomed. 23(7), 803–820 (2010) Jones, D.K., Cercignani, M.: Twenty-five pitfalls in the analysis of diffusion MRI data. NMR Biomed. 23(7), 803–820 (2010)
43.
go back to reference Junichi, H., Sakiko, M., Yawara, H., Masayuki, S., Yae, K., Kazuhiro, C., Hideyuki, O., Masaya, N., Keisuke, H.: Semiquantitative evaluation of muscle repair by diffusion tensor imaging in mice. J. Bone Miner. Res. Plus 2(4), 227–234 (2018) Junichi, H., Sakiko, M., Yawara, H., Masayuki, S., Yae, K., Kazuhiro, C., Hideyuki, O., Masaya, N., Keisuke, H.: Semiquantitative evaluation of muscle repair by diffusion tensor imaging in mice. J. Bone Miner. Res. Plus 2(4), 227–234 (2018)
44.
go back to reference Kim, Y.J., Kim, S.H., Kang, B.J., Park, C.S., Kim, H.S., Son, Y.H., Porter, D.A., Song, B.J.: Readout-segmented echo-planar imaging in diffusion-weighted mr imaging in breast cancer: comparison with single-shot echo-planar imaging in image quality. Korean J. Radiol. 15(4), 403–410 (2014) Kim, Y.J., Kim, S.H., Kang, B.J., Park, C.S., Kim, H.S., Son, Y.H., Porter, D.A., Song, B.J.: Readout-segmented echo-planar imaging in diffusion-weighted mr imaging in breast cancer: comparison with single-shot echo-planar imaging in image quality. Korean J. Radiol. 15(4), 403–410 (2014)
45.
go back to reference Koh, D.M., Collins, D.J.: Diffusion-weighted MRI in the body: applications and challenges in oncology. AJR Am. J. Roentgenol. 188(6), 1622–1635 (2007) Koh, D.M., Collins, D.J.: Diffusion-weighted MRI in the body: applications and challenges in oncology. AJR Am. J. Roentgenol. 188(6), 1622–1635 (2007)
46.
go back to reference Korn, N., Kurhanewicz, J., Banerjee, S., Starobinets, O., Saritas, E., Noworolski, S.: Reduced-FOV excitation decreases susceptibility artifact in diffusion-weighted MRI with endorectal coil for prostate cancer detection. Magn. Reson. Imaging 33(1), 56–62 (2015) Korn, N., Kurhanewicz, J., Banerjee, S., Starobinets, O., Saritas, E., Noworolski, S.: Reduced-FOV excitation decreases susceptibility artifact in diffusion-weighted MRI with endorectal coil for prostate cancer detection. Magn. Reson. Imaging 33(1), 56–62 (2015)
47.
go back to reference Kucharczyk, J., Mintorovitch, J., Asgari, H.S., Moseley, M.: Diffusion/perfusion MR imaging of acute cerebral ischemia. Magn. Reson. Med. 19(2), 311–315 (1991) Kucharczyk, J., Mintorovitch, J., Asgari, H.S., Moseley, M.: Diffusion/perfusion MR imaging of acute cerebral ischemia. Magn. Reson. Med. 19(2), 311–315 (1991)
48.
go back to reference Kung, G.L., Nguyen, T.C., Itoh, A., Skare, S., Ingels, N.B.J., Miller, D.C., Ennis, D.B.: The presence of two local myocardial sheet populations confirmed by diffusion tensor MRI and histological validation. J. Magn. Reson. Imaging 34(5), 1080–1091 (2011) Kung, G.L., Nguyen, T.C., Itoh, A., Skare, S., Ingels, N.B.J., Miller, D.C., Ennis, D.B.: The presence of two local myocardial sheet populations confirmed by diffusion tensor MRI and histological validation. J. Magn. Reson. Imaging 34(5), 1080–1091 (2011)
49.
go back to reference Kurugol, S., Freiman, M., Afacan, O., Domachevsky, L., Perez-Rossello, J.M., Callahan, M.J., Warfield, S.K.: Motion-robust parameter estimation in abdominal diffusion-weighted MRI by simultaneous image registration and model estimation. Med. Image Anal. 39, 124–132 (2017) Kurugol, S., Freiman, M., Afacan, O., Domachevsky, L., Perez-Rossello, J.M., Callahan, M.J., Warfield, S.K.: Motion-robust parameter estimation in abdominal diffusion-weighted MRI by simultaneous image registration and model estimation. Med. Image Anal. 39, 124–132 (2017)
50.
go back to reference Lau, A.Z., Tunnicliffe, E.M., Frost, R., Koopmans, P.J., Tyler, D.J., Robson, M.D.: Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn. Reson. Med. 73(3), 995–1004 (2015) Lau, A.Z., Tunnicliffe, E.M., Frost, R., Koopmans, P.J., Tyler, D.J., Robson, M.D.: Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn. Reson. Med. 73(3), 995–1004 (2015)
51.
go back to reference Le Bihan, D., Breton, E., Lallemand, D., Aubin, M.L., Vignaud, J., Laval-Jeantet, M.: Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168(2), 497–505 (1988) Le Bihan, D., Breton, E., Lallemand, D., Aubin, M.L., Vignaud, J., Laval-Jeantet, M.: Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168(2), 497–505 (1988)
52.
go back to reference Leemans, A., Jones, D.K.: The B-matrix must be rotated when correcting for subject motion in DTI data. Magn. Reson. Med. 61(6), 1336–49 (2009) Leemans, A., Jones, D.K.: The B-matrix must be rotated when correcting for subject motion in DTI data. Magn. Reson. Med. 61(6), 1336–49 (2009)
53.
go back to reference Li, T., Yu, T., Li, L., Lu, L., Zhuo, Y., Lian, J., Xiong, Y., Kong, D., Li, K.: Use of diffusion kurtosis imaging and quantitative dynamic contrast-enhanced MRI for the differentiation of breast tumors. J. Magn. Reson. Imaging p. [Epub ahead of print] (2018). https://doi.org/10.1002/jmri.26059 Li, T., Yu, T., Li, L., Lu, L., Zhuo, Y., Lian, J., Xiong, Y., Kong, D., Li, K.: Use of diffusion kurtosis imaging and quantitative dynamic contrast-enhanced MRI for the differentiation of breast tumors. J. Magn. Reson. Imaging p. [Epub ahead of print] (2018). https://​doi.​org/​10.​1002/​jmri.​26059
54.
go back to reference Li, Y.T., Cercueil, J.P., Yuan, J., Chen, W., Loffroy, R., Wáng, Y.X.J.: Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. Quant. Imaging Med. Surg. 7(1), 59–78 (2017) Li, Y.T., Cercueil, J.P., Yuan, J., Chen, W., Loffroy, R., Wáng, Y.X.J.: Liver intravoxel incoherent motion (IVIM) magnetic resonance imaging: a comprehensive review of published data on normal values and applications for fibrosis and tumor evaluation. Quant. Imaging Med. Surg. 7(1), 59–78 (2017)
55.
go back to reference Liau, J., Lee, J., Schroeder, M.E., Sirlin, C.B., Bydder, M.: Cardiac motion in diffusion-weighted MRI of the liver: artifact and a method of correction. J. Magn. Reson. Med. 35(2), 318–327 (2012) Liau, J., Lee, J., Schroeder, M.E., Sirlin, C.B., Bydder, M.: Cardiac motion in diffusion-weighted MRI of the liver: artifact and a method of correction. J. Magn. Reson. Med. 35(2), 318–327 (2012)
56.
go back to reference Ma, D., Lu, F., Zou, X., Zhang, H., Li, Y., Zhang, L., Chen, L., Qin, D., Wang, B.: Intravoxel incoherent motion diffusion-weighted imaging as an adjunct to dynamic contrast-enhanced MRI to improve accuracy of the differential diagnosis of benign and malignant breast lesions. Magn. Reson. Imaging 36, 175–179 (2017) Ma, D., Lu, F., Zou, X., Zhang, H., Li, Y., Zhang, L., Chen, L., Qin, D., Wang, B.: Intravoxel incoherent motion diffusion-weighted imaging as an adjunct to dynamic contrast-enhanced MRI to improve accuracy of the differential diagnosis of benign and malignant breast lesions. Magn. Reson. Imaging 36, 175–179 (2017)
57.
go back to reference Mazzoni, L.N., Lucarini, S., Chiti, S., Busoni, S., Gori, C., Menchi, I.: Diffusion-weighted signal models in healthy and cancerous peripheral prostate tissues: comparison of outcomes obtained at different b-values. J. Magn. Reson. Imaging 39(3), 512–518 (2014) Mazzoni, L.N., Lucarini, S., Chiti, S., Busoni, S., Gori, C., Menchi, I.: Diffusion-weighted signal models in healthy and cancerous peripheral prostate tissues: comparison of outcomes obtained at different b-values. J. Magn. Reson. Imaging 39(3), 512–518 (2014)
58.
go back to reference McDonald, E.S., Schopp, J., Peacock, S., Olson, M.L., DeMartini, W.B., Rahbar, H., Lehman, C.D., Partridge, S.C.: Diffusion-weighted MRI: Association between patient characteristics and apparent diffusion coefficients of normal breast fibroglandular tissue at 3 tesla. AJR Am. J. Roentgenol. 202(5), 496–502 (2014) McDonald, E.S., Schopp, J., Peacock, S., Olson, M.L., DeMartini, W.B., Rahbar, H., Lehman, C.D., Partridge, S.C.: Diffusion-weighted MRI: Association between patient characteristics and apparent diffusion coefficients of normal breast fibroglandular tissue at 3 tesla. AJR Am. J. Roentgenol. 202(5), 496–502 (2014)
59.
go back to reference Mekkaoui, C., Huang, S., Chen, H.H., Dai, G., Reese, T.G., Kostis, W.J., Thiagalingam, A., Maurovich-Horvat, P., Ruskin, J.N., Hoffmann, U., Jackowski, M.P., Sosnovik, D.E.: Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation. J. Magn. Reson. Imaging 14, 70 (2012) Mekkaoui, C., Huang, S., Chen, H.H., Dai, G., Reese, T.G., Kostis, W.J., Thiagalingam, A., Maurovich-Horvat, P., Ruskin, J.N., Hoffmann, U., Jackowski, M.P., Sosnovik, D.E.: Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation. J. Magn. Reson. Imaging 14, 70 (2012)
60.
61.
go back to reference Mekkaoui, C., Reese, T.G., Jackowski, M.P., Bhat, H., Kostis, W.J., Sosnovik, D.E.: In vivo fiber tractography of the right and left ventricles using diffusion tensor MRI of the entire human heart. J. Cardiovasc. Magn. Reson. 16(Suppl 1), P17 (2014) Mekkaoui, C., Reese, T.G., Jackowski, M.P., Bhat, H., Kostis, W.J., Sosnovik, D.E.: In vivo fiber tractography of the right and left ventricles using diffusion tensor MRI of the entire human heart. J. Cardiovasc. Magn. Reson. 16(Suppl 1), P17 (2014)
62.
go back to reference Mekkaoui, C., Reese, T.G., Jackowski, M.P., Bhat, H., Sosnovik, D.E.: Diffusion MRI in the heart. NMR in Biomed. 30(3), e3426 (2017) Mekkaoui, C., Reese, T.G., Jackowski, M.P., Bhat, H., Sosnovik, D.E.: Diffusion MRI in the heart. NMR in Biomed. 30(3), e3426 (2017)
63.
go back to reference Murphy, P., Hooker, J., Ang, B., Wolfson, T., Gamst, A., Bydder, M., Middleton, M., Peterson, M., Behling, C., Loomba, R., Sirlin, C.: Associations between histologic features of nonalcoholic fatty liver disease (NAFLD) and quantitative diffusion-weighted MRI measurements in adults. J. Magn. Reson. Imaging 41, 1629–1638 (2015) Murphy, P., Hooker, J., Ang, B., Wolfson, T., Gamst, A., Bydder, M., Middleton, M., Peterson, M., Behling, C., Loomba, R., Sirlin, C.: Associations between histologic features of nonalcoholic fatty liver disease (NAFLD) and quantitative diffusion-weighted MRI measurements in adults. J. Magn. Reson. Imaging 41, 1629–1638 (2015)
64.
go back to reference Nguyen, C., Fan, Z., Sharif, B., He, Y., Dharmakumar, R., Berman, D.S., Li, D.: In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach. Magn. Reson. Med. 72(5), 1257–1267 (2014) Nguyen, C., Fan, Z., Sharif, B., He, Y., Dharmakumar, R., Berman, D.S., Li, D.: In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach. Magn. Reson. Med. 72(5), 1257–1267 (2014)
65.
go back to reference Nguyen, V.T., Rahbar, H., Olson, M.L., Liu, C.L., Lehman, C.D., Partridge, S.C.: Diffusion-weighted imaging: effects of intravascular contrast agents on apparent diffusion coefficient measures of breast malignancies at 3 Tesla. J. Magn. Reson. Imaging 42(3), 788–800 (2015) Nguyen, V.T., Rahbar, H., Olson, M.L., Liu, C.L., Lehman, C.D., Partridge, S.C.: Diffusion-weighted imaging: effects of intravascular contrast agents on apparent diffusion coefficient measures of breast malignancies at 3 Tesla. J. Magn. Reson. Imaging 42(3), 788–800 (2015)
66.
go back to reference Nielles-Vallespin, S., Mekkaoui, C., Gatehouse, P., Reese, T.G., Keegan, J., Ferreira, P.F., Collins, S., Speier, P., Feiweier, T., de Silva, R., Jackowski, M.P., Pennell, D.J., Sosnovik, D.E., Firmin, D.: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn. Reson. Med. 70(2), 454–465 (2013) Nielles-Vallespin, S., Mekkaoui, C., Gatehouse, P., Reese, T.G., Keegan, J., Ferreira, P.F., Collins, S., Speier, P., Feiweier, T., de Silva, R., Jackowski, M.P., Pennell, D.J., Sosnovik, D.E., Firmin, D.: In vivo diffusion tensor MRI of the human heart: reproducibility of breath-hold and navigator-based approaches. Magn. Reson. Med. 70(2), 454–465 (2013)
67.
go back to reference Nogueira, L., Brandão, S., Matos, E., Nunes, R.G., Loureiro, J., Ramos, I., Ferreira, H.A.: Application of the diffusion kurtosis model for the study of breast lesions. Eur. Radiol. 24(6), 1197–1203 (2014) Nogueira, L., Brandão, S., Matos, E., Nunes, R.G., Loureiro, J., Ramos, I., Ferreira, H.A.: Application of the diffusion kurtosis model for the study of breast lesions. Eur. Radiol. 24(6), 1197–1203 (2014)
68.
go back to reference Nogueira, L., Brandão, S., Nunes, R.G., Ferreira, H.A., Loureiro, J., Ramos, I.: Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance. Clin. Radiol. 70(3), 286–294 (2015) Nogueira, L., Brandão, S., Nunes, R.G., Ferreira, H.A., Loureiro, J., Ramos, I.: Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance. Clin. Radiol. 70(3), 286–294 (2015)
69.
go back to reference Orton, M.R., Collins, D.J., Koh, D.M., Leach, M.O.: Improved intravoxel incoherent motion analysis of diffusion weighted imaging by data driven Bayesian modeling. Magn. Reson. Med. 71(1), 411–420 (2014) Orton, M.R., Collins, D.J., Koh, D.M., Leach, M.O.: Improved intravoxel incoherent motion analysis of diffusion weighted imaging by data driven Bayesian modeling. Magn. Reson. Med. 71(1), 411–420 (2014)
70.
go back to reference Oudeman, J., Nederveen, A.J., Strijkers, G.J., Maas, M., Luijten, P.R., Froeling, M.: Techniques and applications of skeletal muscle diffusion tensor imaging: a review. J. Magn. Reson. Med. 43(4), 773–788 (2016) Oudeman, J., Nederveen, A.J., Strijkers, G.J., Maas, M., Luijten, P.R., Froeling, M.: Techniques and applications of skeletal muscle diffusion tensor imaging: a review. J. Magn. Reson. Med. 43(4), 773–788 (2016)
71.
go back to reference Padhani, A.R., Liu, G., Koh, D.M., Chenevert, T.L., Thoeny, H.C., Takahara, T., Dzik-Jurasz, A., Ross, B.D., Van Cauteren, M., Collins, D., Hammoud, D.A., Rustin, G.J.S., Taouli, B., Choyke, P.L.: Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11(2), 102–125 (2009) Padhani, A.R., Liu, G., Koh, D.M., Chenevert, T.L., Thoeny, H.C., Takahara, T., Dzik-Jurasz, A., Ross, B.D., Van Cauteren, M., Collins, D., Hammoud, D.A., Rustin, G.J.S., Taouli, B., Choyke, P.L.: Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11(2), 102–125 (2009)
72.
go back to reference Pai, V.M., Rapacchi, S., Kellman, P., Croisille, P., Wen, H.: PCATMIP: enhancing signal intensity in diffusion-weighted magnetic resonance imaging. Magn. Reson. Med. 65(6), 1611–1619 (2011) Pai, V.M., Rapacchi, S., Kellman, P., Croisille, P., Wen, H.: PCATMIP: enhancing signal intensity in diffusion-weighted magnetic resonance imaging. Magn. Reson. Med. 65(6), 1611–1619 (2011)
73.
go back to reference Partridge, S.C., Ziadloo, A., Murthy, R., White, S.W., Peacock, S., Eby, P.R., DeMartini, W.B., Lehman, C.D.: Diffusion tensor MRI: preliminary anisotropy measures and mapping of breast tumors. J. Magn. Reson. Med. 31(2), 339–347 (2010) Partridge, S.C., Ziadloo, A., Murthy, R., White, S.W., Peacock, S., Eby, P.R., DeMartini, W.B., Lehman, C.D.: Diffusion tensor MRI: preliminary anisotropy measures and mapping of breast tumors. J. Magn. Reson. Med. 31(2), 339–347 (2010)
74.
go back to reference Pereira, F.P.A., Martins, G., Carvalhaes de Oliveira, R.D.V.: Diffusion magnetic resonance imaging of the breast. Magn. Reson. Imaging Clin. N. Am. 19(1), 95–110 (2011) Pereira, F.P.A., Martins, G., Carvalhaes de Oliveira, R.D.V.: Diffusion magnetic resonance imaging of the breast. Magn. Reson. Imaging Clin. N. Am. 19(1), 95–110 (2011)
75.
go back to reference Peters, N.H.G.M., Vincken, K.L., van den Bosch, M.A.A.J., Luijten, P.R., Mali, W.P.T.M., Bartels, L.W.: Quantitative diffusion weighted imaging for differentiation of benign and malignant breast lesions: the influence of the choice of b-values. J. Magn. Reson. Imaging 31(5), 1100–1105 (2010) Peters, N.H.G.M., Vincken, K.L., van den Bosch, M.A.A.J., Luijten, P.R., Mali, W.P.T.M., Bartels, L.W.: Quantitative diffusion weighted imaging for differentiation of benign and malignant breast lesions: the influence of the choice of b-values. J. Magn. Reson. Imaging 31(5), 1100–1105 (2010)
76.
go back to reference Van Phi, V.D., Becker, A.S., Ciritsis, A., Reiner, C.S., Boss, A.: Intravoxel incoherent motion analysis of abdominal organs—application of simultaneous multislice acquisition. Investig. Radiol. 53(3), 179–185 (2018) Van Phi, V.D., Becker, A.S., Ciritsis, A., Reiner, C.S., Boss, A.: Intravoxel incoherent motion analysis of abdominal organs—application of simultaneous multislice acquisition. Investig. Radiol. 53(3), 179–185 (2018)
77.
go back to reference Porter, D.A., Heidemann, R.M.: High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn. Reson. Med. 62(2), 468–475 (2009) Porter, D.A., Heidemann, R.M.: High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn. Reson. Med. 62(2), 468–475 (2009)
78.
go back to reference Rahbar, H., Partridge, S.C., DeMartini, W.B., Thursten, B., Lehman, C.D.: Clinical and technical considerations for high quality breast MRI at 3 Tesla. J. Magn. Reson. Imaging 37(4), 778–790 (2013) Rahbar, H., Partridge, S.C., DeMartini, W.B., Thursten, B., Lehman, C.D.: Clinical and technical considerations for high quality breast MRI at 3 Tesla. J. Magn. Reson. Imaging 37(4), 778–790 (2013)
79.
go back to reference Reese, T.G., Weisskoff, R.M., Smith, R.N., Rosen, B.R., Dinsmore, R.E., Wedeen, V.J.: Imaging myocardial fiber architecture in vivo with magnetic resonance. Magn. Reson. Med. 34(6), 786–791 (1995) Reese, T.G., Weisskoff, R.M., Smith, R.N., Rosen, B.R., Dinsmore, R.E., Wedeen, V.J.: Imaging myocardial fiber architecture in vivo with magnetic resonance. Magn. Reson. Med. 34(6), 786–791 (1995)
80.
go back to reference Reese, T., Heid, O., Weisskoff, R., Wedeen, V.: Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn. Reson. Med. 49(1), 177–182 (2003) Reese, T., Heid, O., Weisskoff, R., Wedeen, V.: Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn. Reson. Med. 49(1), 177–182 (2003)
81.
go back to reference Rieseberg, S., Frahm, J., Finsterbusch, J.: Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging. Magn. Reson. Med. 47(6), 1186–1193 (2002) Rieseberg, S., Frahm, J., Finsterbusch, J.: Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging. Magn. Reson. Med. 47(6), 1186–1193 (2002)
82.
go back to reference Rosenkrantz, A.B., Padhani, A.R., Chenevert, T.L., Koh, D.M., De Keyzer, F., Taouli, B., Le Bihan, D.: Body diffusion kurtosis imaging: Basic principles, applications, and considerations for clinical practice. J. Magn. Reson. Med. 42(5), 1190–1202 (2015) Rosenkrantz, A.B., Padhani, A.R., Chenevert, T.L., Koh, D.M., De Keyzer, F., Taouli, B., Le Bihan, D.: Body diffusion kurtosis imaging: Basic principles, applications, and considerations for clinical practice. J. Magn. Reson. Med. 42(5), 1190–1202 (2015)
83.
go back to reference Sanz-Estébanez, S., Rabanillo-Viloria, I., Royuela-del Val, J., Aja-Fernández, S., Alberola-López, C.: Joint groupwise registration and ADC estimation in the liver using a b-value weighted metric. Magn. Reson. Imaging 46, 1–9 (2018) Sanz-Estébanez, S., Rabanillo-Viloria, I., Royuela-del Val, J., Aja-Fernández, S., Alberola-López, C.: Joint groupwise registration and ADC estimation in the liver using a b-value weighted metric. Magn. Reson. Imaging 46, 1–9 (2018)
84.
go back to reference Scheel, M., von Roth, P., Winkler, T., Arampatzis, A., Prokscha, T., Hamm, B., Diederichs, G.: Fiber type characterization in skeletal muscle by diffusion tensor imaging. NMR in Biomed. 26(10), 1220–1224 (2013) Scheel, M., von Roth, P., Winkler, T., Arampatzis, A., Prokscha, T., Hamm, B., Diederichs, G.: Fiber type characterization in skeletal muscle by diffusion tensor imaging. NMR in Biomed. 26(10), 1220–1224 (2013)
85.
go back to reference Scott, A.D., Nielles-Vallespin, S., Ferreira, P.F., Khalique, Z., Gatehouse, P.D., Kilner, P., Pennell, D.J., Firmin, D.N.: An in-vivo comparison of stimulated-echo and motion compensated spin-echo sequences for 3 T diffusion tensor cardiovascular magnetic resonance at multiple cardiac phases. J. Cardiovasc. Magn. Reson. 20(1), 1 (2018) Scott, A.D., Nielles-Vallespin, S., Ferreira, P.F., Khalique, Z., Gatehouse, P.D., Kilner, P., Pennell, D.J., Firmin, D.N.: An in-vivo comparison of stimulated-echo and motion compensated spin-echo sequences for 3 T diffusion tensor cardiovascular magnetic resonance at multiple cardiac phases. J. Cardiovasc. Magn. Reson. 20(1), 1 (2018)
86.
go back to reference Setsompop, K., Gagoski, B.A., Polimeni, J.R., Witzel, T., Wedeen, V.J., Wald, L.L.: Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn. Reson. Med. 67(5), 1210–1224 (2012) Setsompop, K., Gagoski, B.A., Polimeni, J.R., Witzel, T., Wedeen, V.J., Wald, L.L.: Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn. Reson. Med. 67(5), 1210–1224 (2012)
87.
go back to reference Slator, P.J., Hutter, J., McCabe, L., Gomes, A.D.S., Price, A.N., Panagiotaki, E., Rutherford, M.A., Hajnal, J.V., Alexander, D.C.: Placenta microstructure and microcirculation imaging with diffusion MRI. Magn. Reson. Med. 80(2), 756–766 (2018) Slator, P.J., Hutter, J., McCabe, L., Gomes, A.D.S., Price, A.N., Panagiotaki, E., Rutherford, M.A., Hajnal, J.V., Alexander, D.C.: Placenta microstructure and microcirculation imaging with diffusion MRI. Magn. Reson. Med. 80(2), 756–766 (2018)
88.
go back to reference Taimouri, V., Afacan, O., Perez-Rossello, J.M., Callahan, M.J., Mulkern, R.V., Warfield, S.K., Freiman, M.: Spatially constrained incoherent motion method improves diffusion-weighted MRI signal decay analysis in the liver and spleen. Med. Phys. 42(4), 1895–1903 (2015) Taimouri, V., Afacan, O., Perez-Rossello, J.M., Callahan, M.J., Mulkern, R.V., Warfield, S.K., Freiman, M.: Spatially constrained incoherent motion method improves diffusion-weighted MRI signal decay analysis in the liver and spleen. Med. Phys. 42(4), 1895–1903 (2015)
89.
go back to reference Tamada, T., Huang, C., Ream, J.M., Taffel, M., Taneja, S.S., Rosenkrantz, A.B.: Apparent diffusion coefficient values of prostate cancer: comparison of 2D and 3D ROIs. AJR Am. J. Roentgenol. 210(1), 113–117 (2018) Tamada, T., Huang, C., Ream, J.M., Taffel, M., Taneja, S.S., Rosenkrantz, A.B.: Apparent diffusion coefficient values of prostate cancer: comparison of 2D and 3D ROIs. AJR Am. J. Roentgenol. 210(1), 113–117 (2018)
90.
go back to reference Tamada, T., Prabhu, V., Li, J., Babb, J.S., Taneja, S.S., Rosenkrantz, A.B.: Prostate cancer: diffusion-weighted MR imaging for detection and assessment of aggressiveness-comparison between conventional and kurtosis models. Radiology 284(1), 100–108 (2017) Tamada, T., Prabhu, V., Li, J., Babb, J.S., Taneja, S.S., Rosenkrantz, A.B.: Prostate cancer: diffusion-weighted MR imaging for detection and assessment of aggressiveness-comparison between conventional and kurtosis models. Radiology 284(1), 100–108 (2017)
91.
go back to reference Tamada, T., Sone, T., Jo, Y., Yamamoto, A., Ito, K.: Diffusion-weighted MRI and its role in prostate cancer. NMR in Biomed. 27(1), 25–38 (2014) Tamada, T., Sone, T., Jo, Y., Yamamoto, A., Ito, K.: Diffusion-weighted MRI and its role in prostate cancer. NMR in Biomed. 27(1), 25–38 (2014)
92.
go back to reference Teruel, J.R., Cho, G.Y., Moccaldi Rt, M., Goa, P.E., Bathen, T.F., Feiweier, T., Kim, S.G., Moy, L., Sigmund, E.E.: Stimulated echo diffusion tensor imaging (STEAM-DTI) with varying diffusion times as a probe of breast tissue. J. Magn. Reson. Imaging 45(1), 84–93 (2017) Teruel, J.R., Cho, G.Y., Moccaldi Rt, M., Goa, P.E., Bathen, T.F., Feiweier, T., Kim, S.G., Moy, L., Sigmund, E.E.: Stimulated echo diffusion tensor imaging (STEAM-DTI) with varying diffusion times as a probe of breast tissue. J. Magn. Reson. Imaging 45(1), 84–93 (2017)
93.
go back to reference Tian, W., Zhang, J., Tian, F., Shen, J., Niu, T., He, G., Yu, H.: Correlation of diffusion tensor imaging parameters and Gleason scores of prostate cancer. Exp. Ther. Med. 15(1), 351–356 (2018) Tian, W., Zhang, J., Tian, F., Shen, J., Niu, T., He, G., Yu, H.: Correlation of diffusion tensor imaging parameters and Gleason scores of prostate cancer. Exp. Ther. Med. 15(1), 351–356 (2018)
94.
go back to reference Türkbey, B., Aras, Ö., Karabulut, N., Turgut, A.T., Akpnar, E., Alibek, S., Pang, Y., Erturk, S.M., Khouli, R.H.E., Bluemke, D.A., Choyke, P.L.: Diffusion-weighted MRI for detecting and monitoring cancer: a review of current applications in body imaging. Diagn. Interv. Radiol. 18, 46–59 (2012) Türkbey, B., Aras, Ö., Karabulut, N., Turgut, A.T., Akpnar, E., Alibek, S., Pang, Y., Erturk, S.M., Khouli, R.H.E., Bluemke, D.A., Choyke, P.L.: Diffusion-weighted MRI for detecting and monitoring cancer: a review of current applications in body imaging. Diagn. Interv. Radiol. 18, 46–59 (2012)
95.
go back to reference Vargas, H.A., Lawrence, E.M., Mazaheri, Y., Sala, E.: Updates in advanced diffusion-weighted magnetic resonance imaging techniques in the evaluation of prostate cancer. World J. Radiol. 7(8), 184–188 (2014) Vargas, H.A., Lawrence, E.M., Mazaheri, Y., Sala, E.: Updates in advanced diffusion-weighted magnetic resonance imaging techniques in the evaluation of prostate cancer. World J. Radiol. 7(8), 184–188 (2014)
96.
go back to reference Wang, Q., Li, H., Yan, X., Wu, C.J., Liu, X.S., Shi, H.B., Zhang, Y.D.: Histogram analysis of diffusion kurtosis magnetic resonance imaging in differentiation of pathologic Gleason grade of prostate cancer. Urologic Oncol. 33(8), 15–24 (2015) Wang, Q., Li, H., Yan, X., Wu, C.J., Liu, X.S., Shi, H.B., Zhang, Y.D.: Histogram analysis of diffusion kurtosis magnetic resonance imaging in differentiation of pathologic Gleason grade of prostate cancer. Urologic Oncol. 33(8), 15–24 (2015)
97.
go back to reference Wei, H., Viallon, M., Delattre, B.M.A., Moulin, K., Yang, F., Croisille, P., Zhu, Y.: Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion. IEEE Trans. Med. Imaging 34(1), 306–316 (2015) Wei, H., Viallon, M., Delattre, B.M.A., Moulin, K., Yang, F., Croisille, P., Zhu, Y.: Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion. IEEE Trans. Med. Imaging 34(1), 306–316 (2015)
98.
go back to reference Weinreb, J.C., Barentsz, J.O., Choyke, P.L., Cornud, F., Haider, M.A., Macura, K.J., Margolis, D., Schnall, M.D., Shtern, F., Tempany, C.M., Thoeny, H.C., Verma, S.: PI-RADS prostate imaging—reporting and data system: 2015, version 2. Eur. Urol. 69(1), 16–40 (2016) Weinreb, J.C., Barentsz, J.O., Choyke, P.L., Cornud, F., Haider, M.A., Macura, K.J., Margolis, D., Schnall, M.D., Shtern, F., Tempany, C.M., Thoeny, H.C., Verma, S.: PI-RADS prostate imaging—reporting and data system: 2015, version 2. Eur. Urol. 69(1), 16–40 (2016)
99.
go back to reference Weiss, J., Martirosian, P., Taron, J., Othman, A.E., Kuestner, T., Erb, M., Bedke, J., Bamberg, F., Nikolaou, K., Notohamiprodjo, M.: Feasibility of accelerated simultaneous multislice diffusion-weighted MRI of the prostate. J. Magn. Reson. Imaging 46(5), 1507–1515 (2017) Weiss, J., Martirosian, P., Taron, J., Othman, A.E., Kuestner, T., Erb, M., Bedke, J., Bamberg, F., Nikolaou, K., Notohamiprodjo, M.: Feasibility of accelerated simultaneous multislice diffusion-weighted MRI of the prostate. J. Magn. Reson. Imaging 46(5), 1507–1515 (2017)
100.
go back to reference While, P.T.: A comparative simulation study of bayesian fitting approaches to intravoxel incoherent motion modeling in diffusion-weighted MRI. Magn. Reson. Med. 78(6), 2373–2387 (2017) While, P.T.: A comparative simulation study of bayesian fitting approaches to intravoxel incoherent motion modeling in diffusion-weighted MRI. Magn. Reson. Med. 78(6), 2373–2387 (2017)
101.
go back to reference Whitcher, B., Tuch, D.S., Wisco, J.J., Sorensen, A.G., Wang, L.: Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging. Hum. Brain Mapp. 29(3), 346–362 (2008) Whitcher, B., Tuch, D.S., Wisco, J.J., Sorensen, A.G., Wang, L.: Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging. Hum. Brain Mapp. 29(3), 346–362 (2008)
102.
go back to reference Winters, K.V., Reynaud, O., Novikov, D.S., Fieremans, E., Kim, S.G.: Quantifying myofiber integrity using diffusion MRI and random permeable barrier modeling in skeletal muscle growth and Duchenne muscular dystrophy model in mice. Magn. Reson. Med. p. [Epub ahead of print] (2018). https://doi.org/10.1002/mrm.27188 Winters, K.V., Reynaud, O., Novikov, D.S., Fieremans, E., Kim, S.G.: Quantifying myofiber integrity using diffusion MRI and random permeable barrier modeling in skeletal muscle growth and Duchenne muscular dystrophy model in mice. Magn. Reson. Med. p. [Epub ahead of print] (2018). https://​doi.​org/​10.​1002/​mrm.​27188
103.
go back to reference Yang, L., Rao, S., Wang, W., Chen, C., Ding, Y., Yang, C., Grimm, R., Yan, X., Fu, C., Zeng, M.: Staging liver fibrosis with DWI: is there an added value for diffusion kurtosis imaging? Eur. Radiol. 28(7), 3041–3049 (2018) Yang, L., Rao, S., Wang, W., Chen, C., Ding, Y., Yang, C., Grimm, R., Yan, X., Fu, C., Zeng, M.: Staging liver fibrosis with DWI: is there an added value for diffusion kurtosis imaging? Eur. Radiol. 28(7), 3041–3049 (2018)
104.
go back to reference Zech, C.J., Herrmann, K.A., Dietrich, O., Horger, W., Reiser, M.F., Schoenberg, S.O.: Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging: comparison with a standard T2-weighted sequence for detection of focal liver lesions. Investig. Radiol. 43(4), 261–266 (2008) Zech, C.J., Herrmann, K.A., Dietrich, O., Horger, W., Reiser, M.F., Schoenberg, S.O.: Black-blood diffusion-weighted EPI acquisition of the liver with parallel imaging: comparison with a standard T2-weighted sequence for detection of focal liver lesions. Investig. Radiol. 43(4), 261–266 (2008)
Metadata
Title
Diffusion MRI Outside the Brain
Authors
Rita G. Nunes
Luísa Nogueira
Andreia S. Gaspar
Nuno Adubeiro
Sofia Brandão
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-030-05831-9_19

Premium Partner