Estimating the Flashover Probability of Residential Fires Using Monte Carlo Simulations of the MQH Correlation

Author: Morgan C. Bruns

Published in: Fire Technology | Issue 1/2018

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

An important indicator of fire hazard in residential fires is the occurrence of flashover in the room of fire origin. Since the variability of residential fire scenarios is large, many different cases must be considered to evaluate the hazard of a given flammable product. Efficiently predicting the occurrence of flashover of a naturally ventilated compartment is possible using the correlation of McCaffrey, Quintiere, and Harkleroad (MQH). The large variability in United States (U.S.) living room fire scenarios is characterized from available data and propagated through the MQH correlation using Monte Carlo (MC) simulation. For the parameters, for which no relevant data was found, uniform probability distributions were assumed. The scenarios sampled in the MC simulations generally fell within the range of scenarios for which the MQH correlation has been validated. Flashover probabilities were estimated for fires up to 5 MW in heat release rate (HRR) and up to 8 min in duration. It was found that fires with HRRs less than 400 kW have a flashover probability of less than 0.01% regardless of their duration. Typical furniture fires were used as example cases, and it was predicted that a three seat upholstered sofa with a peak HRR of 2.15 MW has a 90% chance of flashing over a randomly chosen U.S. living room. The results of a global sensitivity analysis indicates that the fire location parameter and the vent opening width are the most important parameters affecting the prediction of the occurrence of flashover in U.S. living rooms. The methodology presented is generalizable, and the results can be readily improved by the collection of more data and the use of higher fidelity fire models.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ahrens M (2016) Home structure fires. Technical Report USS12G, National Fire Protection Association, Quincy, Massachusetts Ahrens M (2016) Home structure fires. Technical Report USS12G, National Fire Protection Association, Quincy, Massachusetts
2.
go back to reference Upadhyay RR, Ezekoye OA (2008) Treatment of design fire uncertainty using quadrature method of moments. Fire Saf J, 43:127–139CrossRef Upadhyay RR, Ezekoye OA (2008) Treatment of design fire uncertainty using quadrature method of moments. Fire Saf J, 43:127–139CrossRef
3.
go back to reference Kong D, Johansson N, Lu S, Lo S (2012) A Monte Carlo analysis of the heat release rate uncertainty on available safe egress time. J Fire Prot Eng, 23:5–29CrossRef Kong D, Johansson N, Lu S, Lo S (2012) A Monte Carlo analysis of the heat release rate uncertainty on available safe egress time. J Fire Prot Eng, 23:5–29CrossRef
4.
go back to reference Kong D, Lu S, Lo S (2011) Global sensitivity analysis of occupant egress safety model. Procedia Eng, 11:179–184 Kong D, Lu S, Lo S (2011) Global sensitivity analysis of occupant egress safety model. Procedia Eng, 11:179–184
5.
go back to reference Kong D, Lu S, Xie Q (2011) Uncertainty and sensitivity analyses of heat fire detector model on monte carlo simulation. J Fire Sci, 29:317–337CrossRef Kong D, Lu S, Xie Q (2011) Uncertainty and sensitivity analyses of heat fire detector model on monte carlo simulation. J Fire Sci, 29:317–337CrossRef
6.
go back to reference Bruns MC (2016) Inferring and propagating kinetic parameter uncertainty for condensed phase burning models. Fire Technol, 52(1):93–120CrossRef Bruns MC (2016) Inferring and propagating kinetic parameter uncertainty for condensed phase burning models. Fire Technol, 52(1):93–120CrossRef
7.
go back to reference Bruns MC (2016) Predicting the effects of barrier fabrics on residential upholstered furniture fire hazard. Technical Report NIST Technical Note 1920, National Institute of Standards and Technology, Gaithersburg, Maryland Bruns MC (2016) Predicting the effects of barrier fabrics on residential upholstered furniture fire hazard. Technical Report NIST Technical Note 1920, National Institute of Standards and Technology, Gaithersburg, Maryland
8.
go back to reference McCaffrey BJ, Quintiere JG, Harkleroad MF (1981) Estimating room fire temperatures and the likelihood of flashoverusing fire test data correlations. Fire Technol, 17:98–119CrossRef McCaffrey BJ, Quintiere JG, Harkleroad MF (1981) Estimating room fire temperatures and the likelihood of flashoverusing fire test data correlations. Fire Technol, 17:98–119CrossRef
9.
go back to reference Baker G, Wade C, Spearpoint M, Fleischmann C (2013) Developing probabilisitic design fires for performance-based fire safety engineering. Procedia Eng, 62:639–647CrossRef Baker G, Wade C, Spearpoint M, Fleischmann C (2013) Developing probabilisitic design fires for performance-based fire safety engineering. Procedia Eng, 62:639–647CrossRef
10.
go back to reference Peacock RD, McGrattan KB, Forney GP, Reneke PA (2016) CFAST—Consolidated model of fire growth and smoke transport (version 7) volume 1: technical reference guide. Technical Note 1889v1, National Institute of Standards and Technology, Gaithersburg, Maryland Peacock RD, McGrattan KB, Forney GP, Reneke PA (2016) CFAST—Consolidated model of fire growth and smoke transport (version 7) volume 1: technical reference guide. Technical Note 1889v1, National Institute of Standards and Technology, Gaithersburg, Maryland
11.
go back to reference McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2017) Fire dynamics simulator, user’s guide. Technical report, NIST McGrattan K, Hostikka S, McDermott R, Floyd J, Weinschenk C, Overholt K (2017) Fire dynamics simulator, user’s guide. Technical report, NIST
12.
go back to reference Sundström B (1995) Research Commission of the European Communities. Directorate-General for Science, Development, Commission of the European Communities, European Commission Measurement, and Testing Programme. CBUF: fire safety of upholstered furniture : the final report on the CBUF Research Programme. EUR (series). European Commission Measurements and Testing Sundström B (1995) Research Commission of the European Communities. Directorate-General for Science, Development, Commission of the European Communities, European Commission Measurement, and Testing Programme. CBUF: fire safety of upholstered furniture : the final report on the CBUF Research Programme. EUR (series). European Commission Measurements and Testing
13.
go back to reference International Organization for Standardization (ISO) (2017) ISO 13943, Fire safety—Vocabulary. International Organization for Standardization, Geneva, Switzerland International Organization for Standardization (ISO) (2017) ISO 13943, Fire safety—Vocabulary. International Organization for Standardization, Geneva, Switzerland
14.
go back to reference Hagglund B, Jansson R, Onnermark B (1974) Fire development in residential rooms after ignition from nuclear explosions. Technical report, Forsevarets Forskingsantalt Hagglund B, Jansson R, Onnermark B (1974) Fire development in residential rooms after ignition from nuclear explosions. Technical report, Forsevarets Forskingsantalt
15.
go back to reference Thomas PH (1981) Testing products and materials for their contribution to flashover in rooms. Fire Mater, 5(3):103–111CrossRef Thomas PH (1981) Testing products and materials for their contribution to flashover in rooms. Fire Mater, 5(3):103–111CrossRef
16.
go back to reference Walton WD, Thomas PH (2008) Estimating temperatures in compartment fires. In: Dinenno PJ, Drysdale D, Beyler CL, Walton WD (eds) SFPE handbook of fire protection engineering, 4th edn. National Fire Protection Association, Quincy Walton WD, Thomas PH (2008) Estimating temperatures in compartment fires. In: Dinenno PJ, Drysdale D, Beyler CL, Walton WD (eds) SFPE handbook of fire protection engineering, 4th edn. National Fire Protection Association, Quincy
17.
go back to reference McGrattan K, Peacock R, Overholt K (2016) Validation of fire models applied to nuclear power plant safety. Fire Technol, 52:5–24CrossRef McGrattan K, Peacock R, Overholt K (2016) Validation of fire models applied to nuclear power plant safety. Fire Technol, 52:5–24CrossRef
18.
go back to reference Johansson N, Svensson S, van Hees P (2015) An evaluation of two methods to predict temperatures in multi-room compartment fires. Fire Saf J, 77:46–58CrossRef Johansson N, Svensson S, van Hees P (2015) An evaluation of two methods to predict temperatures in multi-room compartment fires. Fire Saf J, 77:46–58CrossRef
19.
go back to reference Mowrer FW, Williamson RB (1987) Estimating room temperatures from fires along walls and in corners. Fire Technol, 23:133–145CrossRef Mowrer FW, Williamson RB (1987) Estimating room temperatures from fires along walls and in corners. Fire Technol, 23:133–145CrossRef
20.
go back to reference Sivia DS (2006) Data analysis, 2nd edn. Oxford University Press, OxfordMATH Sivia DS (2006) Data analysis, 2nd edn. Oxford University Press, OxfordMATH
21.
go back to reference International Code Council, Inc. (2015) International residential code. International Code Council, Inc., Country Club Hills, IL International Code Council, Inc. (2015) International residential code. International Code Council, Inc., Country Club Hills, IL
22.
go back to reference Mehaffey JR, Cuerrier P, Carisse G (1994) A model for predicting heat transfer through gypsum-board/wood-studd walls exposed to fire. Fire Mater, 18:297–305CrossRef Mehaffey JR, Cuerrier P, Carisse G (1994) A model for predicting heat transfer through gypsum-board/wood-studd walls exposed to fire. Fire Mater, 18:297–305CrossRef
23.
go back to reference Sultan MA (1996) A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire. Fire Technol, 32:239–259CrossRef Sultan MA (1996) A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire. Fire Technol, 32:239–259CrossRef
24.
go back to reference Wakili K Ghazi, Hugi E, Wullschleger L, Frank T (2007) Gypsum board in fire—modeling and experimental validation. J Fire Sci, 25:267–282CrossRef Wakili K Ghazi, Hugi E, Wullschleger L, Frank T (2007) Gypsum board in fire—modeling and experimental validation. J Fire Sci, 25:267–282CrossRef
25.
go back to reference Manzello SL, Park SH, Mizukami T, Bentz DP (2008) Measurement of thermal properties of gypsum board at elevated temperatures. In: Fifth international converence on structures in fire, Singapore, pp 656–665 Manzello SL, Park SH, Mizukami T, Bentz DP (2008) Measurement of thermal properties of gypsum board at elevated temperatures. In: Fifth international converence on structures in fire, Singapore, pp 656–665
26.
go back to reference Wakili K Ghazi, Hugi E (2009) Four types of gypsum plaster boards and their thermophysical properties under fire condition. J Fire Sci, 27:27–43CrossRef Wakili K Ghazi, Hugi E (2009) Four types of gypsum plaster boards and their thermophysical properties under fire condition. J Fire Sci, 27:27–43CrossRef
27.
go back to reference U.S. Census Bureau (2013) Suitland, Maryland. American Housing Survey for the United States: 2013 U.S. Census Bureau (2013) Suitland, Maryland. American Housing Survey for the United States: 2013
28.
go back to reference Emrath P (2013) Spaces in new homes. Technical report, National Association of Home Builders (NAHB) Emrath P (2013) Spaces in new homes. Technical report, National Association of Home Builders (NAHB)
29.
go back to reference U.S. Energy Information Administration (2009) Washington, District of Columbia. Residential energy consumption survey U.S. Energy Information Administration (2009) Washington, District of Columbia. Residential energy consumption survey
30.
go back to reference Saltelli A, Annoni P (2010) How to avoid a perfunctory sensitivity analysis. Environ Model Softw, 25:1508–1517CrossRef Saltelli A, Annoni P (2010) How to avoid a perfunctory sensitivity analysis. Environ Model Softw, 25:1508–1517CrossRef
31.
go back to reference Sobol IM (2001) Global sensitivity indices for nonlinear mathematical models and their monte carlo estimates. Math Comput Simul, 55:271–280MathSciNetCrossRefMATH Sobol IM (2001) Global sensitivity indices for nonlinear mathematical models and their monte carlo estimates. Math Comput Simul, 55:271–280MathSciNetCrossRefMATH
Metadata
Title
Estimating the Flashover Probability of Residential Fires Using Monte Carlo Simulations of the MQH Correlation
Author
Morgan C. Bruns
Publication date
13-10-2017
Publisher
Springer US
Published in
Fire Technology / Issue 1/2018
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-017-0680-0

Other articles of this Issue 1/2018

Fire Technology 1/2018 Go to the issue