Cold-formed steel (CFS) members are widely used in the construction industry due to their versatility, excellent strength-to-weight ratio, and ease of assembly. This paper presents a comprehensive numerical study on the fire resistance of double cold-formed steel columns with Σ-shaped sections under non-uniform temperature distribution. Sheathing CFS members typically exposes the column to fire on one side, and the non-uniform temperature distribution within the column significantly affects its structural response at elevated temperatures. Three types of temperature distribution were considered: ISO uniform distribution, uniform distribution applying the average temperature from thermal analysis, and non-uniform distribution applying different temperatures to the hot and cold flanges. A finite element model of the cold-formed steel column was developed using ABAQUS software. Both structural and thermal analyses were conducted, accounting for material and geometric nonlinearities. To validate the finite element model, the numerical thermal and structural results were compared with previous tests and numerical data. A parametric study was carried out by varying the slenderness ratio, screw spacing, temperature distribution, and load ratio of the member. The results showed that increases in column slenderness and temperature distribution significantly impacted the column's failure time and critical temperature. However, increasing screw spacing did not affect the column's failure time.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Cheng Sh, Li L, Kim B (2015) Buckling analysis of cold-formed steel channel-section beams at elevated temperatures. J Constr Steel Res 104:74–80CrossRef Cheng Sh, Li L, Kim B (2015) Buckling analysis of cold-formed steel channel-section beams at elevated temperatures. J Constr Steel Res 104:74–80CrossRef
2.
go back to reference Camotim D, Dinis PB, Martins AD, Young B (2018) Interactive behaviour, failure and DSM design of cold-formed steel members prone to distortional buckling. Thin-Walled Structures 128:12–42CrossRef Camotim D, Dinis PB, Martins AD, Young B (2018) Interactive behaviour, failure and DSM design of cold-formed steel members prone to distortional buckling. Thin-Walled Structures 128:12–42CrossRef
3.
go back to reference Hancock GJ (1985) Distortional buckling of steel storage rack columns. J Struct Eng 111(12):2770–2783CrossRef Hancock GJ (1985) Distortional buckling of steel storage rack columns. J Struct Eng 111(12):2770–2783CrossRef
4.
go back to reference Schafer B (2002) Local, distortional, and Euler buckling of thin-walled columns. J Struct Eng 128(3):289–299CrossRef Schafer B (2002) Local, distortional, and Euler buckling of thin-walled columns. J Struct Eng 128(3):289–299CrossRef
5.
go back to reference Schafer BW, Peköz T (1998) Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses. J Constr Steel Res 47(3):193–210CrossRef Schafer BW, Peköz T (1998) Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses. J Constr Steel Res 47(3):193–210CrossRef
6.
go back to reference Yang J, Luo K, Wang W, Shi Y, Li H (2024) Research on the flexural buckling behavior of the cold-formed steel back-to-back built-up columns with Σ-section. Eng Struct 302:117404CrossRef Yang J, Luo K, Wang W, Shi Y, Li H (2024) Research on the flexural buckling behavior of the cold-formed steel back-to-back built-up columns with Σ-section. Eng Struct 302:117404CrossRef
7.
go back to reference Li Q, Young B (2021) Tests of cold-formed steel built-up open section members under eccentric compressive load [J]. J Constr Steel Res 184:106775CrossRef Li Q, Young B (2021) Tests of cold-formed steel built-up open section members under eccentric compressive load [J]. J Constr Steel Res 184:106775CrossRef
8.
go back to reference Li Q, Young B (2022) Experimental and numerical investigation on cold-formed steel built-up section pin-ended columns [J]. Thin-Walled Struct 170:108444CrossRef Li Q, Young B (2022) Experimental and numerical investigation on cold-formed steel built-up section pin-ended columns [J]. Thin-Walled Struct 170:108444CrossRef
9.
go back to reference Li Q, Young B (2022) Design of cold-formed steel built-up open section members under combined compression and bending [J]. Thin-Walled Struct 172:108890CrossRef Li Q, Young B (2022) Design of cold-formed steel built-up open section members under combined compression and bending [J]. Thin-Walled Struct 172:108890CrossRef
10.
go back to reference Li Q, Young B (2022) Experimental study on cold-formed steel built-up section beam-columns experiencing non-uniform bending [J]. Eng Struct 256:113954CrossRef Li Q, Young B (2022) Experimental study on cold-formed steel built-up section beam-columns experiencing non-uniform bending [J]. Eng Struct 256:113954CrossRef
11.
go back to reference Wang L, Young B (2018) Behaviour and design of cold-formed steel built-up section beams with different screw arrangements. Thin-Walled Struct 131:16–32CrossRef Wang L, Young B (2018) Behaviour and design of cold-formed steel built-up section beams with different screw arrangements. Thin-Walled Struct 131:16–32CrossRef
12.
go back to reference Zhang P, Alam MS (2022) Compression tests of thin-walled cold-formed steel columns with Σ-shaped sections and patterned perforations distributed along the length. Thin-Walled Struct 174:109082CrossRef Zhang P, Alam MS (2022) Compression tests of thin-walled cold-formed steel columns with Σ-shaped sections and patterned perforations distributed along the length. Thin-Walled Struct 174:109082CrossRef
13.
go back to reference Kiran T, Anand N, Anbarasu M, Lubloy E (2023) Post-fire flexural behaviour and performance of unrestrained cold-formed steel built-up section beams: experimental and numerical investigation. Case Stud Construct Mater 18:e01978CrossRef Kiran T, Anand N, Anbarasu M, Lubloy E (2023) Post-fire flexural behaviour and performance of unrestrained cold-formed steel built-up section beams: experimental and numerical investigation. Case Stud Construct Mater 18:e01978CrossRef
14.
go back to reference Gunalan S, Mahendran M (2013) Finite element modelling of load bearing cold-formed steel wall systems under fire conditions. Eng Struct 56:1007–1027CrossRef Gunalan S, Mahendran M (2013) Finite element modelling of load bearing cold-formed steel wall systems under fire conditions. Eng Struct 56:1007–1027CrossRef
15.
go back to reference Landesmann A, Camotim D (2016) Distortional failure and DSM design of cold-formed steel lipped channel beams under elevated temperatures. Thin-Walled Struct 98:75–93CrossRef Landesmann A, Camotim D (2016) Distortional failure and DSM design of cold-formed steel lipped channel beams under elevated temperatures. Thin-Walled Struct 98:75–93CrossRef
16.
go back to reference Selvaraj S, Madhavan M (2021) Design of cold-formed steel back-to-back connected built-up beams. J Constr Steel Res 181:106623CrossRef Selvaraj S, Madhavan M (2021) Design of cold-formed steel back-to-back connected built-up beams. J Constr Steel Res 181:106623CrossRef
17.
go back to reference Feng M, Wang YC, Davies JM (2003) Axial strength of cold-formed thin-walled steel channels under non-uniform temperatures in fire. Fire Safety J 38:679–707CrossRef Feng M, Wang YC, Davies JM (2003) Axial strength of cold-formed thin-walled steel channels under non-uniform temperatures in fire. Fire Safety J 38:679–707CrossRef
18.
go back to reference Fang H, Chan T-M (2022) Behaviour and design of cold-formed normal-and high-strength steel SHS and RHS columns at elevated temperatures. Thin-Walled Struct 180:109947CrossRef Fang H, Chan T-M (2022) Behaviour and design of cold-formed normal-and high-strength steel SHS and RHS columns at elevated temperatures. Thin-Walled Struct 180:109947CrossRef
19.
go back to reference Senthilkumar R, Kumar DP (2021) Numerical studies on restrained cold-formed steel column subjected to transient thermal loading. Structures 32:161–169CrossRef Senthilkumar R, Kumar DP (2021) Numerical studies on restrained cold-formed steel column subjected to transient thermal loading. Structures 32:161–169CrossRef
20.
go back to reference Craveiro HD, Rodrigues JPC, Laím L (2014) Cold-formed steel columns made with open cross-sections subjected to fire. Thin-Walled Struct 85:1–14CrossRef Craveiro HD, Rodrigues JPC, Laím L (2014) Cold-formed steel columns made with open cross-sections subjected to fire. Thin-Walled Struct 85:1–14CrossRef
22.
go back to reference Yang J, Zhou X, Wang W, Xu L, Shi Y (2023) Fire resistance of box-shape cold-formed steel built-up columns failing in global buckling: test, simulation and design. Thin-Walled Struct 183:110433CrossRef Yang J, Zhou X, Wang W, Xu L, Shi Y (2023) Fire resistance of box-shape cold-formed steel built-up columns failing in global buckling: test, simulation and design. Thin-Walled Struct 183:110433CrossRef
23.
go back to reference Sabu Sam V, Adarsh MS, Lyngdoh GR, Marak GWK, Anand N, Al-Jabri K, Andrushia D (2023) Influence of elevated temperature on buckling capacity of mild steel-based cold-formed steel column sections–experimental investigation and finite element modelling. J Struct Fire Eng 15(3):314–337CrossRef Sabu Sam V, Adarsh MS, Lyngdoh GR, Marak GWK, Anand N, Al-Jabri K, Andrushia D (2023) Influence of elevated temperature on buckling capacity of mild steel-based cold-formed steel column sections–experimental investigation and finite element modelling. J Struct Fire Eng 15(3):314–337CrossRef
24.
go back to reference Chen MT, Pandey M, Young B (2021) Post-fire residual material properties of cold-formed steel elliptical hollow sections. J Constr Steel Res 183:106723CrossRef Chen MT, Pandey M, Young B (2021) Post-fire residual material properties of cold-formed steel elliptical hollow sections. J Constr Steel Res 183:106723CrossRef
25.
go back to reference Yang J, Shi Y, Wang W, Xu L, Al-azzani H (2020) Experimental and numerical studies on axially restrained cold-formed steel built-up box columns at elevated temperatures. J Constr Steel Res 171:106143CrossRef Yang J, Shi Y, Wang W, Xu L, Al-azzani H (2020) Experimental and numerical studies on axially restrained cold-formed steel built-up box columns at elevated temperatures. J Constr Steel Res 171:106143CrossRef
26.
go back to reference Dai Y et al (2023) A critical review of cold-formed built-up members: developments, challenges, and future directions. J Build Eng 76:107255CrossRef Dai Y et al (2023) A critical review of cold-formed built-up members: developments, challenges, and future directions. J Build Eng 76:107255CrossRef
27.
go back to reference Cui Y et al (2024) Testing, numerical modelling and design of G550 high strength cold-formed steel built-up section columns. Thin-Walled Struct. 196:111529CrossRef Cui Y et al (2024) Testing, numerical modelling and design of G550 high strength cold-formed steel built-up section columns. Thin-Walled Struct. 196:111529CrossRef
28.
go back to reference Jiang L et al (2024) Compressive behavior of novel cold-formed steel built-up closed L-shaped section columns. J Build Eng 86:108748CrossRef Jiang L et al (2024) Compressive behavior of novel cold-formed steel built-up closed L-shaped section columns. J Build Eng 86:108748CrossRef
29.
go back to reference Yang J et al (2024) Research on the flexural buckling behavior of the cold-formed steel back-to-back built-up columns with Σ-section. En Struct 302:117404CrossRef Yang J et al (2024) Research on the flexural buckling behavior of the cold-formed steel back-to-back built-up columns with Σ-section. En Struct 302:117404CrossRef
30.
go back to reference Yang J et al (2024) Axial compressive behavior of cold-formed steel built-up box-shape columns with longitudinal stiffeners. J Construct Steel Re 212:108274CrossRef Yang J et al (2024) Axial compressive behavior of cold-formed steel built-up box-shape columns with longitudinal stiffeners. J Construct Steel Re 212:108274CrossRef
31.
go back to reference Li Y et al (2020) Mechanical properties of steels for cold-formed steel structures at elevated temperatures. Adv Civil Eng 2020:9627357CrossRef Li Y et al (2020) Mechanical properties of steels for cold-formed steel structures at elevated temperatures. Adv Civil Eng 2020:9627357CrossRef
32.
go back to reference Nei Z et al. (2020) High-temperature mechanical properties of cold-formed steel. J Struct Eng. Nei Z et al. (2020) High-temperature mechanical properties of cold-formed steel. J Struct Eng.
33.
go back to reference Imran I Mahendran M (2018) Thermal effects on cold-formed steel structures. J Construct Steel Res. Imran I Mahendran M (2018) Thermal effects on cold-formed steel structures. J Construct Steel Res.
34.
go back to reference Kankanage Nadini, Mahendran Mahendran (2011) Mechanical properties of cold-formed steels at elevated temperatures. Thin-Walled Struct 49:26–44CrossRef Kankanage Nadini, Mahendran Mahendran (2011) Mechanical properties of cold-formed steels at elevated temperatures. Thin-Walled Struct 49:26–44CrossRef
35.
go back to reference Li Y Young B (2017) Ductility of cold-formed steel at elevated temperatures. Construct Build Mater. Li Y Young B (2017) Ductility of cold-formed steel at elevated temperatures. Construct Build Mater.
36.
go back to reference Wang et al. (2019) Thermal expansion and performance of cold-formed steel. Fire Safety J. Wang et al. (2019) Thermal expansion and performance of cold-formed steel. Fire Safety J.
37.
go back to reference Rokilan S et al. (2019) Failure Modes of cold-formed steel under thermal loading. Eng Struct. Rokilan S et al. (2019) Failure Modes of cold-formed steel under thermal loading. Eng Struct.
38.
go back to reference Craveiro HDS (2015) Fire resistance of cold-formed steel columns. Ph.D. thesis. Portugal: University of Coimbra. Craveiro HDS (2015) Fire resistance of cold-formed steel columns. Ph.D. thesis. Portugal: University of Coimbra.
39.
go back to reference ISO 834-1 (1999) Fire resistance tests-elements of building construction, Part1: general requirements. Switzerland: International Organization for Standardization Geneva. ISO 834-1 (1999) Fire resistance tests-elements of building construction, Part1: general requirements. Switzerland: International Organization for Standardization Geneva.
40.
go back to reference Eurocode 3: Design of steel structures. Part 1–3: Design of cold-formed steel structures, ECCS – European Convention for Constructional Steelwork, WileyBlackwell, p. 676. Eurocode 3: Design of steel structures. Part 1–3: Design of cold-formed steel structures, ECCS – European Convention for Constructional Steelwork, WileyBlackwell, p. 676.
41.
go back to reference Dias Y, Keerthan P, Mahendran M (2018) Predicting the fire performance of LSF walls made of web stiffened channel sections. Eng Struct 168:320–332CrossRef Dias Y, Keerthan P, Mahendran M (2018) Predicting the fire performance of LSF walls made of web stiffened channel sections. Eng Struct 168:320–332CrossRef
Metadata
Title
Examination of the Behavior of Double Cold-Formed Steel Columns with Σ-Shaped Sections Subjected to Non-Uniform Temperature Conditions
Authors
Xin Liu
Suqin Kuang
Woyu Luo
Zecong Xie
Publication date
25-09-2024
Publisher
Springer US
Published in
Fire Technology
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-024-01651-4