Abstract

After the basics of heat transfer calculation (heating load and cooling load) are explained, heating and cooling systems are described, divided into generation and distribution. The distinction is made according to energy carrier (generation) and the use of renewable energy. Many details of the generation systems are listed, including construction details (e.g. exhaust gas systems) with references to standards and laws. Holistic supply concepts with integrated heating, cooling and power-heat-cold-coupling systems are presented with numerous examples. Heating and cooling distribution systems in rooms are presented as an essential feature of the perceived thermal quality with design tips and examples.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Footnotes
1
According to the building code of the countries, the height of the floor of living rooms is limited to max. 7 m above ground level in buildings “of low height“ (usually corresponds to a two-story construction).
 
2
Under building regulations in the countries, the floor height of living spaces in “low-rise” buildings is limited to a maximum of 7 m above the ground level.
 
3
An (undesirable) high water vapour dew point temperature (condensation already at relatively high return temperatures) requires a high CO2 content in the exhaust gas. In addition, a high CO2 content, and thus a low excess air, characterise perfect combustion. (Theoretically achievable CO2 value for combustion of natural gas: 12 vol.%).
 
4
In the model building code, defined as a building whose highest floor is no more than 7 m above ground level. This category includes single and two-story buildings.
 
5
Water expands by 4.3% when heated from 0 to 100 °C.
 
Metadata
Title
Heating and Cooling Systems
Author
Dirk Bohne
Copyright Year
2023
DOI
https://doi.org/10.1007/978-3-658-41273-9_4