Skip to main content
Top

2020 | OriginalPaper | Chapter

ID-Fit: Intra-Saccular Device Adjustment for Personalized Cerebral Aneurysm Treatment

Authors : Romina Muñoz, Ana Paula Narata, Ignacio Larrabide

Published in: Medical Image Computing and Computer Assisted Intervention – MICCAI 2020

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Intrasaccular devices, like Woven EndoBridge (WEB), are novel braided devices employed for the treatment of aneurysms with a complex shape and location, mostly terminal aneurysms. Such aneurysms are often challenging or impossible to treat with other endovascular techniques such as coils, stents, flow diverter stents. The selection of an appropriate endosaccular device size is crucial for a successful treatment and strongly depends of the final configuration that the device adopts when it adapts to the aneurysm sac morphology. This is frequently a problem during the intervention, leading to replacement of the device, reopening of the aneurysm or a need for re-treatment. A technique that allows predicting the released WEB configuration before intervention will provide a powerful computational tool to aid the interventionist during device selection. We propose a technique based on device design and aneurysm morphology that, by virtually deploying a WEB, will enable the assessment of different device sizes before the device implantation. This technique was tested on 6 MCA aneurysm cases and the simulation results were compared to the size of the deployed device on the patient, using post-treatment images.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Pierot, L., Wakhloo, A.K.: Endovascular treatment of intracranial aneurysms - current status. Stroke 44, 2046–2054 (2013)CrossRef Pierot, L., Wakhloo, A.K.: Endovascular treatment of intracranial aneurysms - current status. Stroke 44, 2046–2054 (2013)CrossRef
2.
go back to reference Cebral, J.R., Chung, B.J., Mut, F., Chudyk, J., Bleise, C., Scrivano, E., Lylyk, P., Kadirvel, R., Kallmes, D.: Analysis of flow dynamics and outcomes of cerebral aneurysms treated with intrasaccular flow-diverting devices. Am. J. Neuroradiol. 40(9), 1511–1516 (2019) Cebral, J.R., Chung, B.J., Mut, F., Chudyk, J., Bleise, C., Scrivano, E., Lylyk, P., Kadirvel, R., Kallmes, D.: Analysis of flow dynamics and outcomes of cerebral aneurysms treated with intrasaccular flow-diverting devices. Am. J. Neuroradiol. 40(9), 1511–1516 (2019)
3.
go back to reference König, I., Weber, A., Weber, W., Fischer, S.: Dislocation of a WEB device into the middle cerebral artery - removal with the alligator retrieval device. Clin Neuroradiol. 29, 361–364 (2019)CrossRef König, I., Weber, A., Weber, W., Fischer, S.: Dislocation of a WEB device into the middle cerebral artery - removal with the alligator retrieval device. Clin Neuroradiol. 29, 361–364 (2019)CrossRef
4.
go back to reference Pierot, L., Liebig, T., Sychra, V., Kadziolka, K., Dorn, F., Strasilla, C., Kabbasch, C., Klisch, J.: Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study. Am. J. Neuroradiol. 33(7), 1232–1238 (2012)CrossRef Pierot, L., Liebig, T., Sychra, V., Kadziolka, K., Dorn, F., Strasilla, C., Kabbasch, C., Klisch, J.: Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study. Am. J. Neuroradiol. 33(7), 1232–1238 (2012)CrossRef
5.
go back to reference Mut, F., et al.: Image-based modeling of blood flow in cerebral aneurysms treated with intrasaccular flow diverting devices. Numer. Methods Biomed. Eng. 35(6), e3202 (2019)CrossRef Mut, F., et al.: Image-based modeling of blood flow in cerebral aneurysms treated with intrasaccular flow diverting devices. Numer. Methods Biomed. Eng. 35(6), e3202 (2019)CrossRef
6.
go back to reference Asnafi, S., Rouchaud, A., Pierot, L., Brinjikji, W., Murad, M.H., Kallmes, D.F.: Efficacy and safety of the Woven Endobridge (WEB) device for the treatment of inracranial aneurysms: a systematic review and meta-analysis. Am J Neuroradiol. 37, 2287–2292 (2016)CrossRef Asnafi, S., Rouchaud, A., Pierot, L., Brinjikji, W., Murad, M.H., Kallmes, D.F.: Efficacy and safety of the Woven Endobridge (WEB) device for the treatment of inracranial aneurysms: a systematic review and meta-analysis. Am J Neuroradiol. 37, 2287–2292 (2016)CrossRef
7.
go back to reference Larrabide, I.: Method for determining the final length of stents before the positioning thereof. US Patent App. 14/911,938, August 11 2016 Larrabide, I.: Method for determining the final length of stents before the positioning thereof. US Patent App. 14/911,938, August 11 2016
8.
go back to reference Piccinelli, M., Veneziani, A., Steinman, D.A., Remuzzi, A., Antiga, L.: A framework for geometric analysis of vascular structures: application to cerebral aneurysms. IEEE Trans. Med. Imaging 28(8), 1141–1155 (2009)CrossRef Piccinelli, M., Veneziani, A., Steinman, D.A., Remuzzi, A., Antiga, L.: A framework for geometric analysis of vascular structures: application to cerebral aneurysms. IEEE Trans. Med. Imaging 28(8), 1141–1155 (2009)CrossRef
9.
go back to reference Fernandez, Hector., Macho, Juan M., Blasco, Jordi., Roman, Luis San., Mailaender, Werner., Serra, Luis, Larrabide, Ignacio: Computation of the change in length of a braided device when deployed in realistic vessel models. Int. J. Comput. Assist. Radiol. Surg. 10(10), 1659–1665 (2015). https://doi.org/10.1007/s11548-015-1230-1CrossRef Fernandez, Hector., Macho, Juan M., Blasco, Jordi., Roman, Luis San., Mailaender, Werner., Serra, Luis, Larrabide, Ignacio: Computation of the change in length of a braided device when deployed in realistic vessel models. Int. J. Comput. Assist. Radiol. Surg. 10(10), 1659–1665 (2015). https://​doi.​org/​10.​1007/​s11548-015-1230-1CrossRef
10.
go back to reference Larrabide, I., Villa-Uriol, M.C., Cárdenes, R., Barbarito, V., Carotenuto, L., Geers, A.J., Omedas, P., et al.: Angiolab-a software tool for morphological analysis and endovascular treatment planning of intracranial aneurysms. Comput. Methods Programs Biomed. 108(2), 806–819 (2012)CrossRef Larrabide, I., Villa-Uriol, M.C., Cárdenes, R., Barbarito, V., Carotenuto, L., Geers, A.J., Omedas, P., et al.: Angiolab-a software tool for morphological analysis and endovascular treatment planning of intracranial aneurysms. Comput. Methods Programs Biomed. 108(2), 806–819 (2012)CrossRef
11.
go back to reference Popielski, J., Berlis, A., Weber, W., Fisher, S.: Two-Center experience in the endovascular treatment of ruptured and unruptured intracranial aneurysms using the WEB device: a retrospective analysis. Am. J. Neuroradiol. 39(1), 111–117 (2018)CrossRef Popielski, J., Berlis, A., Weber, W., Fisher, S.: Two-Center experience in the endovascular treatment of ruptured and unruptured intracranial aneurysms using the WEB device: a retrospective analysis. Am. J. Neuroradiol. 39(1), 111–117 (2018)CrossRef
Metadata
Title
ID-Fit: Intra-Saccular Device Adjustment for Personalized Cerebral Aneurysm Treatment
Authors
Romina Muñoz
Ana Paula Narata
Ignacio Larrabide
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-59725-2_10

Premium Partner