Skip to main content
Top
Published in: Fire Technology 5/2016

01-09-2016

Indirect Detection of Visual Signals for Emergency Notification

Authors: John D. Bullough, Nicholas P. Skinner, Yiting Zhu

Published in: Fire Technology | Issue 5/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Flashing visual signal lights for emergency notification have usually used xenon strobe light sources, which produce very short flashes of light. Photometric performance specifications for these signal lights use the effective intensity as the primary metric. Effective intensity appears to be a suitable metric for characterizing detection of signal lights when directly viewed at or near the line of sight. For the indirect detection of xenon strobe light sources, when the light source is in the far periphery or outside of the field of view and the primary cue of the signal’s flashing is the increase in brightness of adjacent room surfaces, an effective intensity of 15 cd seems to be sufficient. When signal lights produce longer flashes of light than xenon strobe sources, much higher effective intensities are needed for indirect detection, suggesting that effective intensity is poorly correlated with detection performance. A series of human factors experiments confirmed this suggestion. Based on the experimental results, a modified metric for characterizing the indirect detection of visual signals, termed the indirect effectiveness quantity (IEQ), was developed. The IEQ metric may be particularly useful at predicting indirect detection of visual signals with flash durations longer than those of xenon strobe light sources, such as some configurations using light-emitting diodes. Experimental data from the present study suggest that under ambient room illumination of 500 lx, an IEQ value of 750 cd will elicit indirect detection percentages of about 90%, independent of the flash duration.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference National Fire Protection Association (2010) NFPA 72: national fire alarm and signaling code. National Fire Protection Association, Quincy National Fire Protection Association (2010) NFPA 72: national fire alarm and signaling code. National Fire Protection Association, Quincy
5.
go back to reference International Association of Lighthouse Authorities (2008) IALA Recommendation E-200-4: Marine signal lights, part 4: Determination and calculation of effective intensity. International Association of Lighthouse Authorities, St. Germain-en-Laye International Association of Lighthouse Authorities (2008) IALA Recommendation E-200-4: Marine signal lights, part 4: Determination and calculation of effective intensity. International Association of Lighthouse Authorities, St. Germain-en-Laye
6.
go back to reference Bullough JD, Skinner NP, Taranta RT (2013) Characterising the effective intensity of multiple-pulse flashing lights. Lighting Res Technol 45:377–390CrossRef Bullough JD, Skinner NP, Taranta RT (2013) Characterising the effective intensity of multiple-pulse flashing lights. Lighting Res Technol 45:377–390CrossRef
7.
go back to reference Bullough JD, Skinner NP (2013) Conspicuity of flashes of light: Interactions between intensity and duration. J Mod Opt 60:1193–1199MathSciNetCrossRef Bullough JD, Skinner NP (2013) Conspicuity of flashes of light: Interactions between intensity and duration. J Mod Opt 60:1193–1199MathSciNetCrossRef
8.
go back to reference Holmes JG (ed) (1971) The perception and application of flashing lights. University of Toronto Press, Toronto Holmes JG (ed) (1971) The perception and application of flashing lights. University of Toronto Press, Toronto
9.
go back to reference Illuminating Engineering Society (1964) IES guide for calculating the effective intensity of flashing signal lights. Illuminating Engineering Society, New York Illuminating Engineering Society (1964) IES guide for calculating the effective intensity of flashing signal lights. Illuminating Engineering Society, New York
10.
go back to reference Blondel A, Rey J (1912) The perception of lights of short duration at their range limits. Trans Illum Eng Soc 7:625–662 Blondel A, Rey J (1912) The perception of lights of short duration at their range limits. Trans Illum Eng Soc 7:625–662
11.
go back to reference Bullough JD, Zhu Y, Narendran N (2012) Characteristics of light-emitting diode sources: relevance for visual signal detection. In: Proceedings of the technical working conference on suppression, detection and signaling research and applications (SUPDET), Phoenix, (5–8/03) Bullough JD, Zhu Y, Narendran N (2012) Characteristics of light-emitting diode sources: relevance for visual signal detection. In: Proceedings of the technical working conference on suppression, detection and signaling research and applications (SUPDET), Phoenix, (5–8/03)
12.
go back to reference Bullough JD, Zhu Y (2012) Performance objectives of light sources used in emergency notification appliances. Fire Protection Research Foundation, Quincy Bullough JD, Zhu Y (2012) Performance objectives of light sources used in emergency notification appliances. Fire Protection Research Foundation, Quincy
13.
go back to reference DeVoss F (1991) Report of research on emergency signaling devices for use by the hearing impaired. Underwriters Laboratories, Northbrook DeVoss F (1991) Report of research on emergency signaling devices for use by the hearing impaired. Underwriters Laboratories, Northbrook
14.
go back to reference Rea MS (ed) (2000) IESNA lighting handbook: reference and application. Illuminating Engineering Society, New York Rea MS (ed) (2000) IESNA lighting handbook: reference and application. Illuminating Engineering Society, New York
15.
go back to reference Savage K (2011) Flash pulse width effectiveness in notification appliances. In: Proceedings of the technical working conference on suppression, detection and signaling research and applications (SUPDET), Orlando, (22–25/03) Savage K (2011) Flash pulse width effectiveness in notification appliances. In: Proceedings of the technical working conference on suppression, detection and signaling research and applications (SUPDET), Orlando, (22–25/03)
16.
go back to reference Kelly DH (1961) Visual responses to time-dependent stimuli: I. Amplitude sensitivity measurements. J Opt Soc Am 51:422–429CrossRef Kelly DH (1961) Visual responses to time-dependent stimuli: I. Amplitude sensitivity measurements. J Opt Soc Am 51:422–429CrossRef
17.
go back to reference Bullough JD, Sweater Hickcox K, Klein TR, Narendran N (2011) Effects of flicker characteristics from solid-state lighting on detection, acceptability and comfort. Lighting Res Technol 43:337–348CrossRef Bullough JD, Sweater Hickcox K, Klein TR, Narendran N (2011) Effects of flicker characteristics from solid-state lighting on detection, acceptability and comfort. Lighting Res Technol 43:337–348CrossRef
18.
go back to reference Bullough JD, Sweater Hickcox K, Klein TR, Lok A, Narendran N (2012) Detection and acceptability of stroboscopic effects from flicker. Lighting Res Technol 44:477–483CrossRef Bullough JD, Sweater Hickcox K, Klein TR, Lok A, Narendran N (2012) Detection and acceptability of stroboscopic effects from flicker. Lighting Res Technol 44:477–483CrossRef
19.
go back to reference Schmidt-Clausen HJ (1971) The influence of the angular size, adaptation luminance, pulse shape and light colour on the Blondel-Rey constant a. In: Holmes JG (ed) The perception and application of flashing lights. University of Toronto, Toronto, pp 95–111 Schmidt-Clausen HJ (1971) The influence of the angular size, adaptation luminance, pulse shape and light colour on the Blondel-Rey constant a. In: Holmes JG (ed) The perception and application of flashing lights. University of Toronto, Toronto, pp 95–111
20.
go back to reference Battersby WS, Schuckman H (1970) The time course of temporal summation. Vis Res 10:263–273CrossRef Battersby WS, Schuckman H (1970) The time course of temporal summation. Vis Res 10:263–273CrossRef
Metadata
Title
Indirect Detection of Visual Signals for Emergency Notification
Authors
John D. Bullough
Nicholas P. Skinner
Yiting Zhu
Publication date
01-09-2016
Publisher
Springer US
Published in
Fire Technology / Issue 5/2016
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-015-0488-8

Other articles of this Issue 5/2016

Fire Technology 5/2016 Go to the issue