Skip to main content
Top
Published in: Tribology Letters 1/2021

01-03-2021 | Original Paper

Influence of Adhesive Layer Thickness on Wear Damage of the Bonded Interface Between Enamel and Composite Inlays

Authors: Yuhuan Xiong, Zhou Xu, Ping Yu, Peng Zhao, Shanshan Gao

Published in: Tribology Letters | Issue 1/2021

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The objective of this study was to evaluate the influence of adhesive layer thickness on wear damage of the bonded interface between enamel and composite inlays using self-adhesive resin cement. Sixty bonded interface samples consisting of four different adhesive layer thicknesses (10 ± 10, 50 ± 10, 100 ± 10 and 150 ± 10 μm) were prepared from resin composite (Tetric N Ceram Bulk Fill; Ivoclar Vivadent AG), self-adhesive resin cement (RelyX U200; 3M ESPE) and tooth enamel. Ball-on-flat sliding wear tests (20 N, 1 Hz, 5 × 104 cycles) were performed on four groups of samples (n = 15). The wear depth and wear track morphology of each sample after 5 × 102, 5 × 103, and 5 × 104 cycles were recorded by white light interferometry and scanning electron microscopy, respectively. Optical microscopy was also used to evaluate cracks and their propagation in the samples. Stress distribution of the interface with four different adhesive layer thickness was analyzed by Finite Element Analysis. All the four groups had similar wear evolution on the bonded interface and the adjacent enamel showed characteristic brittle fracture and microcracks. But the extent of wear damage varied among different groups. The 50 ± 10 μm group owned the slightest damage after 5 × 102, 5 × 103, and 5 × 104 cycles. Stress concentration always happened on the enamel near the interface and thinner adhesive layer owned more stress concentration. In conclusion, for self-adhesive resin cement, 50 ± 10 μm was the best thickness of adhesive layer for the enamel–composite inlay interface from the aspect of tribology.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Morimoto, S., Rebello de Sampaio, F.B.W., Braga, M.M., Sesma, N., Özcan, M.: Survival rate of resin and ceramic inlays, onlays, and overlays: a systematic review and meta-analysis. J. Dent. Res. 95, 985–994 (2016)CrossRef Morimoto, S., Rebello de Sampaio, F.B.W., Braga, M.M., Sesma, N., Özcan, M.: Survival rate of resin and ceramic inlays, onlays, and overlays: a systematic review and meta-analysis. J. Dent. Res. 95, 985–994 (2016)CrossRef
2.
go back to reference Kramer, N., Frankenberger, R.: Clinical performance of bonded leucite-reinforced glass ceramic inlays and onlays after eight years. Dent. Mater. 21, 262–271 (2005)CrossRef Kramer, N., Frankenberger, R.: Clinical performance of bonded leucite-reinforced glass ceramic inlays and onlays after eight years. Dent. Mater. 21, 262–271 (2005)CrossRef
3.
go back to reference Santos, M.J.M.C., Freitas, M.C., Azevedo, L.M., Santos, G.C., Navarro, M.F., Francischone, C.E., et al.: Clinical evaluation of ceramic inlays and onlays fabricated with two systems: 12-year follow-up. Clin. Oral. Investig. 20, 1683–1690 (2016)CrossRef Santos, M.J.M.C., Freitas, M.C., Azevedo, L.M., Santos, G.C., Navarro, M.F., Francischone, C.E., et al.: Clinical evaluation of ceramic inlays and onlays fabricated with two systems: 12-year follow-up. Clin. Oral. Investig. 20, 1683–1690 (2016)CrossRef
4.
go back to reference Derchi, G., Marchio, V., Borgia, V., Özcan, M., Giuca, M.R., Barone, A.: Twelve-year longitudinal clinical evaluation of bonded indirect composite resin inlays. Quintessence Int. 50, 448–454 (2019) Derchi, G., Marchio, V., Borgia, V., Özcan, M., Giuca, M.R., Barone, A.: Twelve-year longitudinal clinical evaluation of bonded indirect composite resin inlays. Quintessence Int. 50, 448–454 (2019)
5.
go back to reference Xu, Z., Xiong, Y., Yu, P., Zhao, P., Arola, D., Gao, S.: Wear and damage at the bonded interface between tooth enamel and resin composite. J. Dent. 83, 40–49 (2019)CrossRef Xu, Z., Xiong, Y., Yu, P., Zhao, P., Arola, D., Gao, S.: Wear and damage at the bonded interface between tooth enamel and resin composite. J. Dent. 83, 40–49 (2019)CrossRef
6.
go back to reference Rees, J.S., Jacobsen, P.H.: Stresses generated by luting resins during cementation of composite and ceramic inlays. J. Oral. Rehabil. 19, 115–122 (1992)CrossRef Rees, J.S., Jacobsen, P.H.: Stresses generated by luting resins during cementation of composite and ceramic inlays. J. Oral. Rehabil. 19, 115–122 (1992)CrossRef
7.
go back to reference Takamizawa, T., Barkmeier, W.W., Latta, M.A., Berry, T.P., Tsujimoto, A., Miyazaki, M.: Simulated wear of self-adhesive resin cements. Oper. Dent. 41, 327–338 (2016)CrossRef Takamizawa, T., Barkmeier, W.W., Latta, M.A., Berry, T.P., Tsujimoto, A., Miyazaki, M.: Simulated wear of self-adhesive resin cements. Oper. Dent. 41, 327–338 (2016)CrossRef
8.
go back to reference Tsujimoto, A., Barkmeier, W.W., Takamizawa, T., Latta, M.A., Miayazaki, M.: Relationship between simulated gap wear and generalized wear of resin luting cements. Oper. Dent. 42, E148–E158 (2017)CrossRef Tsujimoto, A., Barkmeier, W.W., Takamizawa, T., Latta, M.A., Miayazaki, M.: Relationship between simulated gap wear and generalized wear of resin luting cements. Oper. Dent. 42, E148–E158 (2017)CrossRef
9.
go back to reference Tsujimoto, A., Barkmeier, W.W., Takamizawa, T., Watanabe, H., Johnson, W.W., Latta, M.A., et al.: Simulated localized wear of resin luting cements for universal adhesive systems with different curing mode. J. Oral. Sci. 60, 29–36 (2018)CrossRef Tsujimoto, A., Barkmeier, W.W., Takamizawa, T., Watanabe, H., Johnson, W.W., Latta, M.A., et al.: Simulated localized wear of resin luting cements for universal adhesive systems with different curing mode. J. Oral. Sci. 60, 29–36 (2018)CrossRef
10.
go back to reference Guess, P.C., Vagkopoulou, T., Zhang, Y., Wolkewitz, M., Strub, J.R.: Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J. Dent. 42, 199–209 (2014)CrossRef Guess, P.C., Vagkopoulou, T., Zhang, Y., Wolkewitz, M., Strub, J.R.: Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue. J. Dent. 42, 199–209 (2014)CrossRef
11.
go back to reference Manhart, J., Chen, H.Y., Neuerer, P., Scheibenbogen-Fuchsbrunner, A., Hickel, R.: Three-year clinical evaluation of composite and ceramic inlays. Am. J. Dent. 14, 95–99 (2001) Manhart, J., Chen, H.Y., Neuerer, P., Scheibenbogen-Fuchsbrunner, A., Hickel, R.: Three-year clinical evaluation of composite and ceramic inlays. Am. J. Dent. 14, 95–99 (2001)
12.
go back to reference Peumans, M., Voet, M., De Munck, J., Van Landuyt, K., Van Ende, A., Van Meerbeek, B.: Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays. Clin. Oral. Investig. 17, 739–750 (2013)CrossRef Peumans, M., Voet, M., De Munck, J., Van Landuyt, K., Van Ende, A., Van Meerbeek, B.: Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays. Clin. Oral. Investig. 17, 739–750 (2013)CrossRef
13.
go back to reference Santos, M.J., Mondelli, R.F., Navarro, M.F., Francischone, C.E., Rubo, J.H., Santos, G.C., Jr.: Clinical evaluation of ceramic inlays and onlays fabricated with two systems: five-year follow-up. Oper. Dent. 38, 3–11 (2013)CrossRef Santos, M.J., Mondelli, R.F., Navarro, M.F., Francischone, C.E., Rubo, J.H., Santos, G.C., Jr.: Clinical evaluation of ceramic inlays and onlays fabricated with two systems: five-year follow-up. Oper. Dent. 38, 3–11 (2013)CrossRef
14.
go back to reference Kramer, N., Frankenberger, R.: Leucite-reinforced glass ceramic inlays after six years: wear of luting composites. Oper. Dent. 25, 466–472 (2000) Kramer, N., Frankenberger, R.: Leucite-reinforced glass ceramic inlays after six years: wear of luting composites. Oper. Dent. 25, 466–472 (2000)
15.
go back to reference Frankenberger, R., Taschner, M., Garcia-Godoy, F., Petschelt, A., Kramer, N.: Leucite-reinforced glass ceramic inlays and onlays after 12 years. J. Adhes. Dent 10, 393–398 (2008) Frankenberger, R., Taschner, M., Garcia-Godoy, F., Petschelt, A., Kramer, N.: Leucite-reinforced glass ceramic inlays and onlays after 12 years. J. Adhes. Dent 10, 393–398 (2008)
16.
go back to reference Heintze, S.D.: Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength II. The correlation between marginal quality and clinical outcome. J. Adhes. Dent. 9, 77–106 (2007) Heintze, S.D.: Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength II. The correlation between marginal quality and clinical outcome. J. Adhes. Dent. 9, 77–106 (2007)
17.
go back to reference Stappert, C.F., Chitmongkolsuk, S., Silva, N.R., Att, W., Strub, J.R.: Effect of mouth-motion fatigue and thermal cycling on the marginal accuracy of partial coverage restorations made of various dental materials. Dent. Mater. 24, 1248–1257 (2008)CrossRef Stappert, C.F., Chitmongkolsuk, S., Silva, N.R., Att, W., Strub, J.R.: Effect of mouth-motion fatigue and thermal cycling on the marginal accuracy of partial coverage restorations made of various dental materials. Dent. Mater. 24, 1248–1257 (2008)CrossRef
18.
go back to reference Addi, S., Hedayati-Khams, A., Poya, A., Sjögren, G.: Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro. J. Dent. 30, 53–58 (2002)CrossRef Addi, S., Hedayati-Khams, A., Poya, A., Sjögren, G.: Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro. J. Dent. 30, 53–58 (2002)CrossRef
19.
go back to reference Martin, N., Jedynakiewicz, N.M.: Interface dimensions of CEREC-2 MOD inlays. Dent. Mater. 16, 68–74 (2000)CrossRef Martin, N., Jedynakiewicz, N.M.: Interface dimensions of CEREC-2 MOD inlays. Dent. Mater. 16, 68–74 (2000)CrossRef
20.
go back to reference Ausiello, P., Apicella, A., Davidson, C.L.: Effect of adhesive layer properties on stress distribution in composite restorations: a 3D finite element analysis. Dent. Mater. 18, 295–303 (2002)CrossRef Ausiello, P., Apicella, A., Davidson, C.L.: Effect of adhesive layer properties on stress distribution in composite restorations: a 3D finite element analysis. Dent. Mater. 18, 295–303 (2002)CrossRef
21.
go back to reference May, L.G., Kelly, J.R., Bottino, M.A., Hill, T.: Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: Multi-physics FEA modeling and monotonic testing. Dent. Mater. 28, e99–e109 (2012)CrossRef May, L.G., Kelly, J.R., Bottino, M.A., Hill, T.: Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: Multi-physics FEA modeling and monotonic testing. Dent. Mater. 28, e99–e109 (2012)CrossRef
22.
go back to reference May, L.G., Kelly, J.R.: Influence of resin cement polymerization shrinkage on stresses in porcelain crowns. Dent. Mater. 29, 1073–1079 (2013)CrossRef May, L.G., Kelly, J.R.: Influence of resin cement polymerization shrinkage on stresses in porcelain crowns. Dent. Mater. 29, 1073–1079 (2013)CrossRef
23.
go back to reference Kawai, K., Isenberg, B.P., Leinfelder, K.F.: Effect of gap dimension on composite resin cement wear. Quintessence Int. 25, 53–58 (1994) Kawai, K., Isenberg, B.P., Leinfelder, K.F.: Effect of gap dimension on composite resin cement wear. Quintessence Int. 25, 53–58 (1994)
24.
go back to reference Shinkai, K., Suzuki, S., Leinfelder, K.F., Katoh, Y.: Effect of gap dimension on wear resistance of luting agents. Am. J. Dent. 8, 149–151 (1995) Shinkai, K., Suzuki, S., Leinfelder, K.F., Katoh, Y.: Effect of gap dimension on wear resistance of luting agents. Am. J. Dent. 8, 149–151 (1995)
25.
go back to reference Guzman, A.F., Moore, B.K., Andres, C.J.: Wear resistance of four luting agents as a function of marginal gap distance, cement type, and restorative material. Int. J. Prosthodont. 10, 415–425 (1997) Guzman, A.F., Moore, B.K., Andres, C.J.: Wear resistance of four luting agents as a function of marginal gap distance, cement type, and restorative material. Int. J. Prosthodont. 10, 415–425 (1997)
26.
go back to reference Torii, Y., Itou, K., Itota, T., Hama, K., Konishi, N., Nagamine, M., et al.: Influence of filler content and gap dimension on wear resistance of resin composite luting cements around a CAD/CAM ceramic inlay restoration. Dent. Mater. J. 18, 453–461 (1999)CrossRef Torii, Y., Itou, K., Itota, T., Hama, K., Konishi, N., Nagamine, M., et al.: Influence of filler content and gap dimension on wear resistance of resin composite luting cements around a CAD/CAM ceramic inlay restoration. Dent. Mater. J. 18, 453–461 (1999)CrossRef
27.
go back to reference Trumpaite-Vanagiene, R.: Wear resistance of luting cements and the influence of marginal gap width on substance loss. Stomatologija 5, 70–76 (2003) Trumpaite-Vanagiene, R.: Wear resistance of luting cements and the influence of marginal gap width on substance loss. Stomatologija 5, 70–76 (2003)
28.
go back to reference Heintze, S.D., Zappini, G., Rousson, V.: Wear of ten dental restorative materials in five wear simulators: results of a round robin test. Dent. Mater. 21, 304–317 (2005)CrossRef Heintze, S.D., Zappini, G., Rousson, V.: Wear of ten dental restorative materials in five wear simulators: results of a round robin test. Dent. Mater. 21, 304–317 (2005)CrossRef
29.
go back to reference Krejci, I., Albert, P., Lutz, F.: The influence of antagonist standardization on wear. J. Dent. Res. 78, 713–719 (1999)CrossRef Krejci, I., Albert, P., Lutz, F.: The influence of antagonist standardization on wear. J. Dent. Res. 78, 713–719 (1999)CrossRef
30.
go back to reference Liu, H.-L., Lin, C.-L., Sun, M.-T., Chang, Y.-H.: 3D micro-crack propagation simulation at enamel/adhesive interface using FE submodeling and element death techniques. Ann. Biomed. Eng. 38, 2004–2012 (2010)CrossRef Liu, H.-L., Lin, C.-L., Sun, M.-T., Chang, Y.-H.: 3D micro-crack propagation simulation at enamel/adhesive interface using FE submodeling and element death techniques. Ann. Biomed. Eng. 38, 2004–2012 (2010)CrossRef
31.
go back to reference Algera, T.J., Feilzer, A.J., Prahl-Andersen, B., Kleverlaan, C.J.: A comparison of finite element analysis with in vitro bond strength tests of the bracket-cement-enamel system. Eur. J. Orthod. 33, 608–612 (2011)CrossRef Algera, T.J., Feilzer, A.J., Prahl-Andersen, B., Kleverlaan, C.J.: A comparison of finite element analysis with in vitro bond strength tests of the bracket-cement-enamel system. Eur. J. Orthod. 33, 608–612 (2011)CrossRef
32.
go back to reference Geng, J.-P., Tan, K.B.C., Liu, G.-R.: Application of finite element analysis in implant dentistry: a review of the literature. J. Prosthet. Dent. 85, 585–598 (2001)CrossRef Geng, J.-P., Tan, K.B.C., Liu, G.-R.: Application of finite element analysis in implant dentistry: a review of the literature. J. Prosthet. Dent. 85, 585–598 (2001)CrossRef
33.
go back to reference Walker, M.P., Spencer, P., Eick, J.D.: Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties. J. Oral. Rehabil. 30, 837–846 (2003)CrossRef Walker, M.P., Spencer, P., Eick, J.D.: Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties. J. Oral. Rehabil. 30, 837–846 (2003)CrossRef
34.
go back to reference Hahnel, S., Schultz, S., Trempler, C., Ach, B., Handel, G., Rosentritt, M.: Two-body wear of dental restorative materials. J. Mech. Behav. Biomed. Mater. 4, 237–244 (2011)CrossRef Hahnel, S., Schultz, S., Trempler, C., Ach, B., Handel, G., Rosentritt, M.: Two-body wear of dental restorative materials. J. Mech. Behav. Biomed. Mater. 4, 237–244 (2011)CrossRef
35.
go back to reference Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., et al.: Marginal and internal fit of CAD-CAM inlay/onlay restorations: a systematic review of in vitro studies. J. Prosthet. Dent. 121, 590-597.e593 (2019)CrossRef Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., et al.: Marginal and internal fit of CAD-CAM inlay/onlay restorations: a systematic review of in vitro studies. J. Prosthet. Dent. 121, 590-597.e593 (2019)CrossRef
36.
go back to reference McLean, J.W., Von, F.: The estimation of cement film thickness by an in vivo technique. Br. Dent. J. 131, 107–111 (1971)CrossRef McLean, J.W., Von, F.: The estimation of cement film thickness by an in vivo technique. Br. Dent. J. 131, 107–111 (1971)CrossRef
37.
go back to reference Kramer, N., Lohbauer, U., Frankenberger, R.: Adhesive luting of indirect restorations. Am. J. Dent. 13, 60D-76D (2000) Kramer, N., Lohbauer, U., Frankenberger, R.: Adhesive luting of indirect restorations. Am. J. Dent. 13, 60D-76D (2000)
38.
go back to reference Kale, E., Seker, E., Yilmaz, B., Özcelik, T.B.: Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J. Prosthet. Dent. 116, 890–895 (2016)CrossRef Kale, E., Seker, E., Yilmaz, B., Özcelik, T.B.: Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J. Prosthet. Dent. 116, 890–895 (2016)CrossRef
39.
go back to reference Gemalmaz, D., KÜKrer, D, : In vivo and in vitro evaluation of marginal fit of class II ceromer inlays. J. Oral. Rehabil. 33, 436–442 (2006)CrossRef Gemalmaz, D., KÜKrer, D, : In vivo and in vitro evaluation of marginal fit of class II ceromer inlays. J. Oral. Rehabil. 33, 436–442 (2006)CrossRef
40.
go back to reference Yu, P., Xiong, Y., Zhao, P., Xu, Z., Yu, H., Arola, D., et al.: On the wear behavior and damage mechanism of bonded interface: ceramic vs resin composite inlays. J. Mech. Behav. Biomed. Mater. 101, 103430 (2020)CrossRef Yu, P., Xiong, Y., Zhao, P., Xu, Z., Yu, H., Arola, D., et al.: On the wear behavior and damage mechanism of bonded interface: ceramic vs resin composite inlays. J. Mech. Behav. Biomed. Mater. 101, 103430 (2020)CrossRef
41.
go back to reference Burey, A., dos Reis, P.J., Santana Vicentin, B.L., Dezan Garbelini, C.C., Grama Hoeppner, M., Appoloni, C.R.: Polymerization shrinkage and porosity profile of dual cure dental resin cements with different adhesion to dentin mechanisms. Microsc. Res. Tech. 81, 88–96 (2018)CrossRef Burey, A., dos Reis, P.J., Santana Vicentin, B.L., Dezan Garbelini, C.C., Grama Hoeppner, M., Appoloni, C.R.: Polymerization shrinkage and porosity profile of dual cure dental resin cements with different adhesion to dentin mechanisms. Microsc. Res. Tech. 81, 88–96 (2018)CrossRef
42.
go back to reference Aguiar, T.R., Di Francescantonio, M., Bedran-Russo, A.K., Giannini, M.: Inorganic composition and filler particles morphology of conventional and self-adhesive resin cements by SEM/EDX. Microsc. Res. Tech. 75, 1348–1352 (2012)CrossRef Aguiar, T.R., Di Francescantonio, M., Bedran-Russo, A.K., Giannini, M.: Inorganic composition and filler particles morphology of conventional and self-adhesive resin cements by SEM/EDX. Microsc. Res. Tech. 75, 1348–1352 (2012)CrossRef
43.
go back to reference Milutinović-Nikolić, A.D., Medić, V.B., Vuković, Z.M.: Porosity of different dental luting cements. Dent. Mater. 23, 674–678 (2007)CrossRef Milutinović-Nikolić, A.D., Medić, V.B., Vuković, Z.M.: Porosity of different dental luting cements. Dent. Mater. 23, 674–678 (2007)CrossRef
44.
go back to reference Molin, M.K., Karlsson, S.L., Kristiansen, M.S.: Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent. Mater. 12, 245–249 (1996)CrossRef Molin, M.K., Karlsson, S.L., Kristiansen, M.S.: Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent. Mater. 12, 245–249 (1996)CrossRef
45.
go back to reference Urapepon, S., Luesak, W., Suchatlampong, C.: Effect of cement film thickness on shear bond strengths of two resin cements. M. Dent. J. 34, 122–128 (2014) Urapepon, S., Luesak, W., Suchatlampong, C.: Effect of cement film thickness on shear bond strengths of two resin cements. M. Dent. J. 34, 122–128 (2014)
46.
go back to reference Rodrigues, D.S., Buciumeanu, M., Martinelli, A.E., Nascimento, R.M., Henriques, B., Silva, F.S., et al.: Mechanical strength and wear of dental glass-ionomer and resin composites affected by porosity and chemical composition. J. Bio. Tribocorros. 1, 24 (2015) Rodrigues, D.S., Buciumeanu, M., Martinelli, A.E., Nascimento, R.M., Henriques, B., Silva, F.S., et al.: Mechanical strength and wear of dental glass-ionomer and resin composites affected by porosity and chemical composition. J. Bio. Tribocorros. 1, 24 (2015)
47.
go back to reference Alster, D., Feilzer, A.J., De Gee, A.J., Davidson, C.L.: Tensile strength of thin resin composite layers as a function of layer thickness. J. Dent. Res. 74, 1745–1748 (1995)CrossRef Alster, D., Feilzer, A.J., De Gee, A.J., Davidson, C.L.: Tensile strength of thin resin composite layers as a function of layer thickness. J. Dent. Res. 74, 1745–1748 (1995)CrossRef
48.
go back to reference Soares, C.J., Faria, E.S.A.L., Rodrigues, M.P., Vilela, A.B.F., Pfeifer, C.S., Tantbirojn, D., et al.: Polymerization shrinkage stress of composite resins and resin cements: what do we need to know? Braz. Oral. Res. 31, e62 (2017)CrossRef Soares, C.J., Faria, E.S.A.L., Rodrigues, M.P., Vilela, A.B.F., Pfeifer, C.S., Tantbirojn, D., et al.: Polymerization shrinkage stress of composite resins and resin cements: what do we need to know? Braz. Oral. Res. 31, e62 (2017)CrossRef
49.
go back to reference Kemp-Scholte, C.M., Davidson, C.L.: Complete marginal seal of Class V resin composite restorations effected by increased flexibility. J. Dent. Res. 69, 1240–1243 (1990)CrossRef Kemp-Scholte, C.M., Davidson, C.L.: Complete marginal seal of Class V resin composite restorations effected by increased flexibility. J. Dent. Res. 69, 1240–1243 (1990)CrossRef
50.
go back to reference Aggarwal, V., Logani, A., Jain, V., Shah, N.: Effect of cyclic loading on marginal adaptation and bond strength in direct vs. indirect class II MO composite restorations. Oper. Dent. 33, 587–592 (2008)CrossRef Aggarwal, V., Logani, A., Jain, V., Shah, N.: Effect of cyclic loading on marginal adaptation and bond strength in direct vs. indirect class II MO composite restorations. Oper. Dent. 33, 587–592 (2008)CrossRef
51.
go back to reference Alonso, R.C.B., Sinhoreti, M.A.C., Correr Sobrinho, L., Consani, S., Goes, M.F.D.: Effect of resin liners on the microleakage of class V dental composite restorations. J. Appl. Oral. Sci. 12, 56–61 (2004)CrossRef Alonso, R.C.B., Sinhoreti, M.A.C., Correr Sobrinho, L., Consani, S., Goes, M.F.D.: Effect of resin liners on the microleakage of class V dental composite restorations. J. Appl. Oral. Sci. 12, 56–61 (2004)CrossRef
52.
go back to reference Zheng, L., Li, Y., Zheng, J., Wen, M., Zhang, Y.F., Qian, L.M., et al.: A comparative study on the sliding wear behaviors of human tooth enamel, Cu–Zn alloy and Al2O3 ceramic. Wear 301, 308–315 (2013)CrossRef Zheng, L., Li, Y., Zheng, J., Wen, M., Zhang, Y.F., Qian, L.M., et al.: A comparative study on the sliding wear behaviors of human tooth enamel, Cu–Zn alloy and Al2O3 ceramic. Wear 301, 308–315 (2013)CrossRef
53.
go back to reference Ravikiran, A., Jahanmir, S.: Effect of interfacial layers on wear behavior of a dental glass-ceramic. J. Am. Ceram. Soc. 83, 1831–1833 (2000)CrossRef Ravikiran, A., Jahanmir, S.: Effect of interfacial layers on wear behavior of a dental glass-ceramic. J. Am. Ceram. Soc. 83, 1831–1833 (2000)CrossRef
54.
go back to reference Rudolph, H., Luthardt, R.G., Walter, M.H.: Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Comput. Biol. Med. 37, 579–587 (2007)CrossRef Rudolph, H., Luthardt, R.G., Walter, M.H.: Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Comput. Biol. Med. 37, 579–587 (2007)CrossRef
55.
go back to reference Beuer, F., Schweiger, J., Edelhoff, D.: Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br. Dent. J. 204, 505–511 (2008)CrossRef Beuer, F., Schweiger, J., Edelhoff, D.: Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br. Dent. J. 204, 505–511 (2008)CrossRef
56.
go back to reference Judge, R.B., Wilson, P.R.: The effects of oscillating forces upon the flow of dental cements. J. Oral. Rehabil. 26, 892–899 (1999)CrossRef Judge, R.B., Wilson, P.R.: The effects of oscillating forces upon the flow of dental cements. J. Oral. Rehabil. 26, 892–899 (1999)CrossRef
57.
go back to reference Hayashi, M., Miura, M., Nishimura, N., Takeshige, F., Ebisu, S.: Effect of cavity form and setting expansion of refractory dies on adaptability of fired ceramic inlays. Oper. Dent. 25, 33–39 (2000) Hayashi, M., Miura, M., Nishimura, N., Takeshige, F., Ebisu, S.: Effect of cavity form and setting expansion of refractory dies on adaptability of fired ceramic inlays. Oper. Dent. 25, 33–39 (2000)
58.
go back to reference Thompson, M.C., Thompson, K.M., Swain, M.: The all-ceramic, inlay supported fixed partial denture. Part 1. Ceramic inlay preparation design: a literature review. Aust. Dent. J. 55, 120–127 (2010)CrossRef Thompson, M.C., Thompson, K.M., Swain, M.: The all-ceramic, inlay supported fixed partial denture. Part 1. Ceramic inlay preparation design: a literature review. Aust. Dent. J. 55, 120–127 (2010)CrossRef
59.
go back to reference Schmidlin, P.R., Zehnder, M., Schlup-Mityko, C., Gohring, T.N.: Interface evaluation after manual and ultrasonic insertion of standardized class I inlays using composite resin materials of different viscosity. Acta. Odontol. Scand. 63, 205–212 (2005)CrossRef Schmidlin, P.R., Zehnder, M., Schlup-Mityko, C., Gohring, T.N.: Interface evaluation after manual and ultrasonic insertion of standardized class I inlays using composite resin materials of different viscosity. Acta. Odontol. Scand. 63, 205–212 (2005)CrossRef
60.
go back to reference Silva, N.R.D., Rodrigues, M.P., Bicalho, A.A., Soares, P.B.F., Price, R.B., Soares, C.J.: Effect of resin cement mixing and insertion method into the root canal on cement porosity and fiberglass post bond strength. J. Adhes. Dent. 21, 37–46 (2019) Silva, N.R.D., Rodrigues, M.P., Bicalho, A.A., Soares, P.B.F., Price, R.B., Soares, C.J.: Effect of resin cement mixing and insertion method into the root canal on cement porosity and fiberglass post bond strength. J. Adhes. Dent. 21, 37–46 (2019)
61.
go back to reference Cantoro, A., Goracci, C., Coniglio, I., Magni, E., Polimeni, A., Ferrari, M.: Influence of ultrasound application on inlays luting with self-adhesive resin cements. Clin. Oral. Investig. 15, 617–623 (2011)CrossRef Cantoro, A., Goracci, C., Coniglio, I., Magni, E., Polimeni, A., Ferrari, M.: Influence of ultrasound application on inlays luting with self-adhesive resin cements. Clin. Oral. Investig. 15, 617–623 (2011)CrossRef
62.
go back to reference Sadighpour, L., Fazel, A., Geramipanah, F., Allahdadi, M.: Effect of resin cement mixing method on the retention strength of a CAD/CAM zirconia crowns. J. Indian. Prosthodont. Soc. 14, 31–36 (2014)CrossRef Sadighpour, L., Fazel, A., Geramipanah, F., Allahdadi, M.: Effect of resin cement mixing method on the retention strength of a CAD/CAM zirconia crowns. J. Indian. Prosthodont. Soc. 14, 31–36 (2014)CrossRef
Metadata
Title
Influence of Adhesive Layer Thickness on Wear Damage of the Bonded Interface Between Enamel and Composite Inlays
Authors
Yuhuan Xiong
Zhou Xu
Ping Yu
Peng Zhao
Shanshan Gao
Publication date
01-03-2021
Publisher
Springer US
Published in
Tribology Letters / Issue 1/2021
Print ISSN: 1023-8883
Electronic ISSN: 1573-2711
DOI
https://doi.org/10.1007/s11249-020-01397-4

Other articles of this Issue 1/2021

Tribology Letters 1/2021 Go to the issue

Premium Partners