Inspection and Testing of Respirators and Anaesthesia Machines

Author : Baki Karaböce

Published in: Inspection of Medical Devices

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Respirators are used in intensive care units and in operating rooms. It consists of filtering, air compression, and humidifying control board units. A respirator is a device that combines the patient’s respiratory tract to assist the respiratory system in conditions where the patient has difficulty in breathing or after operations. The device supplies controlled air to the patient by the inner compressor. The breakdown of the oxygen sensor and the heating of the circuit boards (if the filter is not cleaned) are the most common problems in respirators. They may not stabilize with required values over time and the tester is used to maintain stability. The device must be calibrated regularly or if the gauge of the test device does not match the standard values of gas flow, volume, pressure and oxygen parameters. The anaesthesia machine delivers pressurised medical gases like air, oxygen, nitrous oxide, heliox etc. and controls the gas flow individually. It composes a known and controlled gas mixture at a known flow rate and then delivers it to the gas outlet of the machine. Therefore, the fresh gas flow is serviced to the anaesthesia circle breathing system in order to make artificial respiration in the patient and monitor vital functions closely. For patient safety, the most important thing is to check out the system regularly and in pre-use and to ensure that there exists a ready and functioning alternative solution for ventilating the patient’s lungs.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
3.
go back to reference Bellis M (2009) Forrest bird invented a fluid control device, respirator and pediatric ventilator. www.about.com. Retrieved 4 June 2009 Bellis M (2009) Forrest bird invented a fluid control device, respirator and pediatric ventilator. www.​about.​com. Retrieved 4 June 2009
5.
go back to reference Brockwell RC, Andrews GG (2002) Understanding your anaesthesia machine. ASA refresher courses, vol 4. Lippincott Williams & Wilkin, Philadelphia, pp 41–59 Brockwell RC, Andrews GG (2002) Understanding your anaesthesia machine. ASA refresher courses, vol 4. Lippincott Williams & Wilkin, Philadelphia, pp 41–59
6.
go back to reference Thompson PW, Wilkinson DJ (1985) Development of anaesthetic machines. Br J Anaesth 57:640–648CrossRef Thompson PW, Wilkinson DJ (1985) Development of anaesthetic machines. Br J Anaesth 57:640–648CrossRef
7.
go back to reference Dorsch JA, Dorsch SE (eds) (2007) Understanding anesthesia equipment. 5th edn. Hazards of anesthesia machines and breathing systems, Lippincott Williams and Wilkins, Philadelphia, pp 373–403 Dorsch JA, Dorsch SE (eds) (2007) Understanding anesthesia equipment. 5th edn. Hazards of anesthesia machines and breathing systems, Lippincott Williams and Wilkins, Philadelphia, pp 373–403
8.
go back to reference Brockwell RC, Andrews JJ (2002) Complications of inhaled anesthesia delivery systems. Anesthesiol Clin North America. 20:539–554CrossRef Brockwell RC, Andrews JJ (2002) Complications of inhaled anesthesia delivery systems. Anesthesiol Clin North America. 20:539–554CrossRef
9.
go back to reference Sugiuchi N, Miyazato K, Hara K, Horiguchi T, Shinozaki K, Aoki T (2000) Failure of operating room oxygen delivery due to a structural defect in the ceiling column. Masui. 49:1165–1168 Sugiuchi N, Miyazato K, Hara K, Horiguchi T, Shinozaki K, Aoki T (2000) Failure of operating room oxygen delivery due to a structural defect in the ceiling column. Masui. 49:1165–1168
10.
go back to reference Aitkenhead AR (2005) Injuries associated with anaesthesia. A global perspective. Br J Anaesth 95(1):95–109. Epub 2005 May 20 Aitkenhead AR (2005) Injuries associated with anaesthesia. A global perspective. Br J Anaesth 95(1):95–109. Epub 2005 May 20
11.
go back to reference Posner KL (2001) Closed claims project shows safety evolution. Anesthesia Patient Safety Foundation Newsletter Posner KL (2001) Closed claims project shows safety evolution. Anesthesia Patient Safety Foundation Newsletter
14.
go back to reference Skinner M (1998). Ventilator function under hyperbaric conditions. South Pac Underw Med Soc J 28(2). Retrieved 4 June 2009 Skinner M (1998). Ventilator function under hyperbaric conditions. South Pac Underw Med Soc J 28(2). Retrieved 4 June 2009
15.
go back to reference Weaver LK, Greenway L, Elliot CG (1988). Performance of the Seachrist 500A hyperbaric ventilator in a monoplace hyperbaric chamber. J Hyperb Med 3(4): 215–225. Retrieved 4 June 2009 Weaver LK, Greenway L, Elliot CG (1988). Performance of the Seachrist 500A hyperbaric ventilator in a monoplace hyperbaric chamber. J Hyperb Med 3(4): 215–225. Retrieved 4 June 2009
17.
go back to reference Cassidy CJ, Smith A, Arnot-Smith J (2011) Critical incident reports concerning anaesthetic equipment: analysis of the UK national reporting and learning system (nrls) data from 2006–2008. Anaesthesia 66:879–888CrossRef Cassidy CJ, Smith A, Arnot-Smith J (2011) Critical incident reports concerning anaesthetic equipment: analysis of the UK national reporting and learning system (nrls) data from 2006–2008. Anaesthesia 66:879–888CrossRef
18.
go back to reference Merchant R, Chartrand D, Dain S, Dobson G, Kurrek M, Lagace A, Stacey S, Thiessen B (2013) Guidelines to the practice of anaesthesia Revised Edition 2013 Merchant R, Chartrand D, Dain S, Dobson G, Kurrek M, Lagace A, Stacey S, Thiessen B (2013) Guidelines to the practice of anaesthesia Revised Edition 2013
22.
go back to reference Badnjevic A, Gurbeta L, Jimenez ER, Iadanza E (2017) Testing of mechanical ventilators and infant incubators in healthcare institutions. Technol Health Care J Badnjevic A, Gurbeta L, Jimenez ER, Iadanza E (2017) Testing of mechanical ventilators and infant incubators in healthcare institutions. Technol Health Care J
23.
go back to reference Gurbeta L, Badnjevic A, Sejdinovic D, Alic B, Abd El-Ilah L, Zunic E (2016) Software solution for tracking inspection processes of medical devices from legal metrology system. XIV Mediterranean conference on medical and biological engineering and computing (MEDICON), Paphos, Cyprus, 31 Mar–02 April Gurbeta L, Badnjevic A, Sejdinovic D, Alic B, Abd El-Ilah L, Zunic E (2016) Software solution for tracking inspection processes of medical devices from legal metrology system. XIV Mediterranean conference on medical and biological engineering and computing (MEDICON), Paphos, Cyprus, 31 Mar–02 April
24.
go back to reference IEC EN 60601-1 General requirements for electrical medical equipment IEC EN 60601-1 General requirements for electrical medical equipment
Metadata
Title
Inspection and Testing of Respirators and Anaesthesia Machines
Author
Baki Karaböce
Copyright Year
2018
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-6650-4_9