Inverse finite-element modeling for tissue parameter identification using a rolling indentation probe

Authors: Hongbin Liu, Kiattisak Sangpradit, Min Li, Prokar Dasgupta, Kaspar Althoefer, Lakmal D. Seneviratne

Published in: Medical & Biological Engineering & Computing | Issue 1/2014

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper investigates the use of inverse finite-element modeling (IFEM)-based methods for tissue parameter identification using a rolling indentation probe for surgical palpation. An IFEM-based algorithm is proposed for tissue parameter identification through uniaxial indentation. IFEM-based algorithms are also created for locating and identifying the properties of an embedded tumor through rolling indentation of the soft tissue. Two types of parameter identification for the tissue tumor are investigated (1) identifying the stiffness (μ) of a tumor at a known depth and (2) estimating the depth of the tumor (D) with known mechanical properties. The efficiency of proposed methods has been evaluated through silicone and porcine kidney experiments for both uniaxial indentation and rolling indentation. The results show that both of the proposed IFEM methods for uniaxial indentation and rolling indentation have good robustness and can rapidly converge to the correct results. The tissue properties estimated using the developed method are generic and in good agreement with results obtained from standard material tests. The estimation error of μ through uniaxial indentation is below 3 % for both silicone and kidney; the estimation error of μ for the tumor through rolling indentation is 7–9 %. The estimation error of D through rolling indentation is 1–2 mm.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ahn BM, Kim YJ, Oh CK, Kim J (2012) Robotic palpation and mechanical property characterization for abnormal tissue localization. Med Biol Eng Comput 50(9):961–971PubMedCrossRef Ahn BM, Kim YJ, Oh CK, Kim J (2012) Robotic palpation and mechanical property characterization for abnormal tissue localization. Med Biol Eng Comput 50(9):961–971PubMedCrossRef
2.
go back to reference Arruda EM, Boyce MC (1993) A three-dimensional model for the large stretch behavior of rubber elastic materials. J Mech Phys Solids 41(2):389–412CrossRef Arruda EM, Boyce MC (1993) A three-dimensional model for the large stretch behavior of rubber elastic materials. J Mech Phys Solids 41(2):389–412CrossRef
3.
go back to reference Beasley R, Howe R (2002) Tactile tracking of arteries in robotic surgery. In: Proceedings of IEEE international conference Robot. Autom, pp 3801–3806. Washington, DC Beasley R, Howe R (2002) Tactile tracking of arteries in robotic surgery. In: Proceedings of IEEE international conference Robot. Autom, pp 3801–3806. Washington, DC
4.
go back to reference Beccani M, Di Natali C, Rentschler M, Valdastri P (2013) Wireless tissue palpation: proof of concept for a single degree of freedom. In: Robotics and automation, 2013. ICRA’13. IEEE international conference on, pp 703–709. IEEE Beccani M, Di Natali C, Rentschler M, Valdastri P (2013) Wireless tissue palpation: proof of concept for a single degree of freedom. In: Robotics and automation, 2013. ICRA’13. IEEE international conference on, pp 703–709. IEEE
5.
go back to reference Bergstrom JS, Boyce MC (1998) Constitutive modeling of the large strain time-dependent behaviour of elastomers. J Mech Phys Solids 46:931–954CrossRef Bergstrom JS, Boyce MC (1998) Constitutive modeling of the large strain time-dependent behaviour of elastomers. J Mech Phys Solids 46:931–954CrossRef
6.
go back to reference Carter T, Sermesant M, Cash D, Barratt D, Tanner C, Hawkes D (2005) Application of soft tissue modelling to image-guided surgery. Med Eng Phys 27(10):893–909PubMedCrossRef Carter T, Sermesant M, Cash D, Barratt D, Tanner C, Hawkes D (2005) Application of soft tissue modelling to image-guided surgery. Med Eng Phys 27(10):893–909PubMedCrossRef
7.
go back to reference Chung JH, Rajagopal V, Laursen TA, Nielsen PM, Nash MP (2008) Frictional contact mechanics methods for soft materials: application to tracking breast cancers. J Biomech 41(1):69–77PubMedCrossRef Chung JH, Rajagopal V, Laursen TA, Nielsen PM, Nash MP (2008) Frictional contact mechanics methods for soft materials: application to tracking breast cancers. J Biomech 41(1):69–77PubMedCrossRef
8.
go back to reference Deml B, Ortmaier T, Seibold U (2005) The touch, and feel in minimally invasive surgery. IEEE International workshop on haptic audio visual environment, and their applications, pp 33–38. Ottawa, Ontario Deml B, Ortmaier T, Seibold U (2005) The touch, and feel in minimally invasive surgery. IEEE International workshop on haptic audio visual environment, and their applications, pp 33–38. Ottawa, Ontario
9.
go back to reference Egorov V, Ayrapetyan S, Sarvazyan AP (2006) Prostate mechanical imaging: 3-D image composition and feature calculations. Med Imaging IEEE Trans 25(10):1329–1340CrossRef Egorov V, Ayrapetyan S, Sarvazyan AP (2006) Prostate mechanical imaging: 3-D image composition and feature calculations. Med Imaging IEEE Trans 25(10):1329–1340CrossRef
10.
go back to reference Erdemir A, Viveiros ML, Ulbrecht JS, Cavanagh PR (2006) An inverse finite-element model of heel-pad indentation. J Biomech 39(7):1279–1286PubMedCrossRef Erdemir A, Viveiros ML, Ulbrecht JS, Cavanagh PR (2006) An inverse finite-element model of heel-pad indentation. J Biomech 39(7):1279–1286PubMedCrossRef
11.
go back to reference Hannaford B, Trujillo J, Sinanan M, et al (1998) Computerized endoscopic surgical grasper. In: Westwood JD, Hoffman HM, Stredney D, Weghorst SJ et al(eds) Medicine meets virtual reality, vol 50. IOS Press, Amsterdam, pp 265-271 Hannaford B, Trujillo J, Sinanan M, et al (1998) Computerized endoscopic surgical grasper. In: Westwood JD, Hoffman HM, Stredney D, Weghorst SJ et al(eds) Medicine meets virtual reality, vol 50. IOS Press, Amsterdam, pp 265-271
12.
go back to reference Kauer M, Vuskovic V, Dual J, Szekely G, Bajka M (2002) Inverse finite element characterization of soft tissues. Med Image Anal 6(3):275PubMedCrossRef Kauer M, Vuskovic V, Dual J, Szekely G, Bajka M (2002) Inverse finite element characterization of soft tissues. Med Image Anal 6(3):275PubMedCrossRef
13.
go back to reference Kim J, Srinivasan MA (2005) Characterization of viscoelastic soft tissue properties from in vivo animal experiments and inverse FE parameter estimation. Med Image Comput Comput Assist Interv 8(Pt 2):599–606PubMed Kim J, Srinivasan MA (2005) Characterization of viscoelastic soft tissue properties from in vivo animal experiments and inverse FE parameter estimation. Med Image Comput Comput Assist Interv 8(Pt 2):599–606PubMed
14.
go back to reference Kim Y, Ahn B, Lee JW, Rha KH, Kim J (2013) Local property characterization of prostate glands using inhomogeneous modeling based on tumor volume and location analysis. Med Biol Eng Comput 51(1–2):197–205 Kim Y, Ahn B, Lee JW, Rha KH, Kim J (2013) Local property characterization of prostate glands using inhomogeneous modeling based on tumor volume and location analysis. Med Biol Eng Comput 51(1–2):197–205
15.
go back to reference Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T (1998) Elastic moduli of breast and prostate tissues under Compression. Ultrason Imaging 20:260–274PubMedCrossRef Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T (1998) Elastic moduli of breast and prostate tissues under Compression. Ultrason Imaging 20:260–274PubMedCrossRef
16.
go back to reference Liu H, Noonan DP, Challacombe BJ, Dasgupta P, Seneviratne LD, Althoefer K (2010) Rolling mechanical imaging for tissue abnormality localization during minimally invasive surgery. IEEE Trans Biomed Eng 57(2):404–414PubMedCrossRef Liu H, Noonan DP, Challacombe BJ, Dasgupta P, Seneviratne LD, Althoefer K (2010) Rolling mechanical imaging for tissue abnormality localization during minimally invasive surgery. IEEE Trans Biomed Eng 57(2):404–414PubMedCrossRef
17.
go back to reference Liu H, Li J, Song X, Seneviratne LD, Althoefer K (2011) Rolling indentation probe for tissue abnormality identification during minimally invasive surgery. Robotics IEEE Trans 27(3):450–460CrossRef Liu H, Li J, Song X, Seneviratne LD, Althoefer K (2011) Rolling indentation probe for tissue abnormality identification during minimally invasive surgery. Robotics IEEE Trans 27(3):450–460CrossRef
18.
go back to reference McCreery GL, Trejos AL, Naish M, Patel R, Malthaner R (2008) Feasibility of locating tumours in lung via kinaesthetic feedback. Int J Med Robotics Comput Assist Surg 4:58–68CrossRef McCreery GL, Trejos AL, Naish M, Patel R, Malthaner R (2008) Feasibility of locating tumours in lung via kinaesthetic feedback. Int J Med Robotics Comput Assist Surg 4:58–68CrossRef
19.
go back to reference Miller K (2005) Method of testing very soft biological tissues in compression. J Biomech 38:153–158PubMedCrossRef Miller K (2005) Method of testing very soft biological tissues in compression. J Biomech 38:153–158PubMedCrossRef
20.
go back to reference Miller A, Peine W, Son J, Hammoud ZT (2007) Tactile imaging system for localizing lung nodules during video-assisted thoracoscopic surgery. In: Proceedings of the IEEE international conference robot. Autom., pp 2996–3001. Rome, Italy Miller A, Peine W, Son J, Hammoud ZT (2007) Tactile imaging system for localizing lung nodules during video-assisted thoracoscopic surgery. In: Proceedings of the IEEE international conference robot. Autom., pp 2996–3001. Rome, Italy
21.
go back to reference Panigrahy A, Caruthers SD, Krejza J, Barnes PD, Faddoul SG, Sleeper LA, Melhem ER (2000) Registration of three-dimensional MR and CT studies of the cervical spine. AJNR Am J Neuroradiol 21:282–289PubMed Panigrahy A, Caruthers SD, Krejza J, Barnes PD, Faddoul SG, Sleeper LA, Melhem ER (2000) Registration of three-dimensional MR and CT studies of the cervical spine. AJNR Am J Neuroradiol 21:282–289PubMed
22.
go back to reference Sadeghi Naini A, Patel RV, Samani A (2011) Measurement of lung hyperelastic properties using inverse finite element approach. IEEE Trans Biomed Eng 58(10):2852–2859. Epub 2011 Jun 30 Sadeghi Naini A, Patel RV, Samani A (2011) Measurement of lung hyperelastic properties using inverse finite element approach. IEEE Trans Biomed Eng 58(10):2852–2859. Epub 2011 Jun 30
23.
go back to reference Samani A, Plewes D (2004) A method to measure the hyperelastic parameters of ex vivo breast tissue samples. Phys Med Biol 49(18):4395PubMedCrossRef Samani A, Plewes D (2004) A method to measure the hyperelastic parameters of ex vivo breast tissue samples. Phys Med Biol 49(18):4395PubMedCrossRef
24.
go back to reference Sangpradit K, Liu H, Seneviratne LD, Althoefer K (2009) Tissue identification using inverse finite element analysis of rolling indentation. In: Robotics and automation, 2009. ICRA’09. IEEE international conference on, pp 1250–1255. IEEE Sangpradit K, Liu H, Seneviratne LD, Althoefer K (2009) Tissue identification using inverse finite element analysis of rolling indentation. In: Robotics and automation, 2009. ICRA’09. IEEE international conference on, pp 1250–1255. IEEE
25.
go back to reference Sangpradit K, Liu H, Dasgupta P, Althoefer K, Seneviratne LD (2011) Finite-element modeling of soft tissue rolling indentation. Biomed Eng IEEE Trans 58(12):3319–3327CrossRef Sangpradit K, Liu H, Dasgupta P, Althoefer K, Seneviratne LD (2011) Finite-element modeling of soft tissue rolling indentation. Biomed Eng IEEE Trans 58(12):3319–3327CrossRef
26.
go back to reference Wang X, Li L, Hu C, Qiu J, Xu Z, Feng Y (2009) A comparative study of three CT and MRI registration algorithms in nasopharyngeal carcinoma. J Appl Clin Med Phys 10(2):3–10 Wang X, Li L, Hu C, Qiu J, Xu Z, Feng Y (2009) A comparative study of three CT and MRI registration algorithms in nasopharyngeal carcinoma. J Appl Clin Med Phys 10(2):3–10
27.
28.
go back to reference Xu X, Gifford-Hollingsworth C, Sensenig R, Shih WH, Shih WY, Brooks AD (2013) Breast tumor detection using piezoelectric fingers: first clinical report. J Am College Surg 216(6):1168–1173 Xu X, Gifford-Hollingsworth C, Sensenig R, Shih WH, Shih WY, Brooks AD (2013) Breast tumor detection using piezoelectric fingers: first clinical report. J Am College Surg 216(6):1168–1173
29.
go back to reference Zhang M, Nigwekar P, Castaneda B, Hoyt K, Joseph JV, Di Sant’Agnese A, Messing EM, Strang JG, Rubens DJ, Parker KJ (2008) Quantitative characterization of viscoelastic properties of human prostate correlated with histology. Ultrasound Med Biol 34(7):1033–1042PubMedCrossRef Zhang M, Nigwekar P, Castaneda B, Hoyt K, Joseph JV, Di Sant’Agnese A, Messing EM, Strang JG, Rubens DJ, Parker KJ (2008) Quantitative characterization of viscoelastic properties of human prostate correlated with histology. Ultrasound Med Biol 34(7):1033–1042PubMedCrossRef
30.
go back to reference Zweiri YH, Seneviratne LD, Althoefer K (2004) Parameter estimation for excavator arm using generalized Newton method. IEEE Trans Rob 20(4):762–767CrossRef Zweiri YH, Seneviratne LD, Althoefer K (2004) Parameter estimation for excavator arm using generalized Newton method. IEEE Trans Rob 20(4):762–767CrossRef
Metadata
Title
Inverse finite-element modeling for tissue parameter identification using a rolling indentation probe
Authors
Hongbin Liu
Kiattisak Sangpradit
Min Li
Prokar Dasgupta
Kaspar Althoefer
Lakmal D. Seneviratne
Publication date
01-01-2014
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 1/2014
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-013-1118-6

Other articles of this Issue 1/2014

Medical & Biological Engineering & Computing 1/2014 Go to the issue

Premium Partner