Skip to main content
Top
Published in: Measurement Techniques 1/2016

29-04-2016

Method for Reproducing and Transmitting Temperature Units Using Fixed Points in Miniature Ampoules

Authors: A. F. Brodnikov, V. Ya. Cherepanov

Published in: Measurement Techniques | Issue 1/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

A procedure is proposed and experimentally verified for determining the metrological characteristics of temperature calibrators using the fixed point of indium solidification in a miniature ampoule with the aid of a multi-junction differential thermocouple. The procedure allows calibrator-reproducible temperature-value errors to be determined, along with calibrator nonuniformity and instability.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference R. E. Bedford, G. Bonnier, H. Maas, and F. Pavese (CCT Working Group 2), “Recommended values of temperature on the ITS-90 for a selected set secondary reference points,” Metrologia, 33, 133–154 (1996). R. E. Bedford, G. Bonnier, H. Maas, and F. Pavese (CCT Working Group 2), “Recommended values of temperature on the ITS-90 for a selected set secondary reference points,” Metrologia, 33, 133–154 (1996).
2.
go back to reference Yu. V. Shevelev and V. Ya. Cherepanov, “Realization of fixed points of the temperature scale in small-size ampoules,” Izmer. Tekhn., No. 2, 39–42 (2004). Yu. V. Shevelev and V. Ya. Cherepanov, “Realization of fixed points of the temperature scale in small-size ampoules,” Izmer. Tekhn., No. 2, 39–42 (2004).
3.
go back to reference A. F. Brodnikov and V. Ya. Cherepanov, “The results of investigations and prospects for using miniature ampoules of fixed points to reproduce and transfer a temperature scale,” Izmer. Tekhn., No. 10, 49–52 (2009). A. F. Brodnikov and V. Ya. Cherepanov, “The results of investigations and prospects for using miniature ampoules of fixed points to reproduce and transfer a temperature scale,” Izmer. Tekhn., No. 10, 49–52 (2009).
Metadata
Title
Method for Reproducing and Transmitting Temperature Units Using Fixed Points in Miniature Ampoules
Authors
A. F. Brodnikov
V. Ya. Cherepanov
Publication date
29-04-2016
Publisher
Springer US
Published in
Measurement Techniques / Issue 1/2016
Print ISSN: 0543-1972
Electronic ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-016-0916-2

Other articles of this Issue 1/2016

Measurement Techniques 1/2016 Go to the issue