As a type of hydraulic rotary actuator, a helical hydraulic rotary actuator exhibits a large angle, high torque, and compact structure; hence, it has been widely used in various fields. However, its core technology is proprietary to several companies and thus has not been disclosed. Furthermore, the relevant reports are primarily limited to the component level. The dynamic characteristics of the output when a helical rotary actuator is applied to a closed-loop system are investigated from the perspective of driving system design. Two main aspects are considered: one is to establish a reliable mathematical model and the other is to consider the effect of system parameter perturbation on the output. In this study, a detailed mechanical analysis of a helical rotary hydraulic cylinder is first performed, factors such as friction and load are considered, and an accurate dynamic model of the actuator is established. Subsequently, considering the nonlinear characteristics of pressure flow and the dynamic characteristics of the valve, a dynamic model of a valve-controlled helical rotary actuator angle closed-loop system is described based on sixth-order nonlinear state equations, which has never been reported previously. After deriving the system model, a sensitivity analysis of 23 main parameters in the model with a perturbation of 10% is performed under nine operating conditions. Finally, the system dynamics model and sensitivity analysis results are verified via a prototype experiment and co-simulation, which demonstrate the reliability of the theoretical results obtained in this study. The results provide an accurate mathematical model and analysis basis for the structural optimization or control compensation of similar systems.
1 Introduction
Helical hydraulic rotary actuators (HHRAs) are hydraulic actuators that convert hydraulic energy into mechanical energy via rotary motion [1]. Compared with conventional rotary hydraulic actuators, such as vane-, rack-, and gear- type ones, helical rotary actuators offer a large rotation angle, high output torque, compact structure, and high volumetric efficiency owing to their unique double helical pair structure [2, 3]. The rotation angle range of a helical actuator can be designed to exceed 360°. Furthermore, for the same rotation angle range, the helical actuator typically exhibits a small weight and volume, which renders the structure installed with it compact [4]. Furthermore, the helical actuator can achieve a higher actuating pressure than the conventional rotary actuator. It can maintain a high efficiency at 21 MPa, which cannot be realized by other forms of hydraulic rotary actuators [5]. Because of these outstanding characteristics, helical rotary actuators have been widely used in certain applications that require large torques, large rotation angles, and limited installation space, e.g., agricultural, construction, and mining machinery [6, 7]. However, only a few companies can manufacture such actuators currently [6‐9], and the core technologies for design and manufacturing remain proprietary. Studies regarding HHRAs, in addition to some patents [10‐12], focus primarily on the component level, including the structural design, dynamic models, flow field analysis, transmission efficiency, and sealing [13‐16].
The performance of a valve-controlled actuator system, as a driving unit, directly affects the control performance of the entire machine [17]. Such systems are typically designed using mathematical models derived from constant-coefficient ordinary differential equations [18]. However, two problems are encountered: First, studies regarding helical rotary actuator driving systems are scarce. Furthermore, the dynamic model of the rotary actuator described in the literature is relatively simple [2, 3] and may not be sufficiently accurate when modeling analysis is required. Therefore, reliable mathematical models for the design and analysis of hydraulic systems are insufficient. The other problem is that the parameters in the model are typically regarded as constants [19]; however, these parameters may not be consistent with the parameters in practical applications because the system parameters are time varying [20]. For example, structural wear results in parameter changes, inaccurate valve test parameters, and pressure fluctuations in the hydraulic system. To obtain a valve-controlled actuator system that satisfies the design requirements, the effect of parameter perturbation on the dynamic characteristics of the system is to be investigated; therefore, a sensitivity analysis of the system parameters is required.
Advertisement
Sensitivity analysis can be performed via several methods, which can be classified into sensitivity functions in the time domain, frequency domain, and the performance-index sensitivity, each of which offers its own advantages and application range [21]. Sensitivity analysis theory is widely used in mechanical design, power systems, water conservancy systems, etc. [22‐24]. In the application of hydraulic systems, trajectory sensitivity analysis in the time domain is most typically used method and can be used for nonlinear systems with time-varying parameters. Vilenius et al. [20] introduced and applied a sensitivity model suitable for deadband-type nonlinearities in a typical servo system used in the sawmill industry. They simplified the valve-controlled actuator system into a fifth-order model and derived a first-order trajectory sensitivity mathematical expression of the system. Under a single operating condition, the sensitivity of the system parameters was defined when the 10 main parameters changed by 1%. Kim et al. [25] used a fourth-order state equation to analyze the nonlinear dynamics of an axial piston pump system and analyzed the sensitivity of the parameters in the model using a first-order sensitivity equation. Pietola et al. [26, 27] investigated the transient-state and steady-state parameter sensitivity of a heavily loaded flexible electro-hydraulic position servo system and then compared three control methods, i.e., P-control, model reference control, and P + PID/\(\dot{{\rm x}} \)-control. Farahat et al. [21] constructed a fourth-order linear mathematical model of an electro-hydraulic servo position control system. The position control sensitivity of the valve-controlled actuator system to 18 main parameters based on a 1% change is investigated, and four sensitivity indices are presented. Kong et al. [28, 29] established a sixth-order nonlinear model of a valve-controlled actuator system based on position control, and the influence degree and rules of 10% parameter changes with respect to the displacement output response were obtained using the first-order trajectory sensitivity method. Subsequently, they deduced the method of second-order trajectory sensitivity and analyzed its effect on the system displacement step response with parameter variation (10% and 20%) under nine operating conditions. Ba et al. [30‐32] proposed a first-order sensitivity matrix method and applied it to the dynamic sensitivity analysis of the valve-controlled actuator system of a legged robot. Huang et al. [33] used the first-order trajectory sensitivity method to determine the dominant parameters of the electro-hydraulic actuator in a legged robot and then estimated them online in real time.
The main difference among the studies above is the degree of simplification of the hydraulic system model. The sensitivity analysis methods are similar and are based on trajectory sensitivity. However, the hydraulic actuators reported in the literature are linear actuators, and a sensitivity analysis of the helical rotary actuator-driven system has not been reported. Compared with linear actuators, helical rotary actuators are more complex in terms of structure, and their model parameters are numerous; therefore, the results of parameter sensitivity analysis for those two types of actuators may be different.
To design and analyze the dynamic characteristics of a valve-controlled helical rotary actuator system, in this study, a relatively accurate dynamic model of an actuator was established. A mechanical analysis of the designed helical rotary actuator was performed, and the friction between different components and load types was considered. Subsequently, considering the nonlinear characteristics of pressure and flow at the valve port and the dynamic characteristics of the servo valve, a sixth-order nonlinear state equation was established to describe an angular displacement closed-loop hydraulic system. Under different step input and load conditions, the sensitivities of 23 parameters in the closed-loop system model were solved using the first-order trajectory sensitivity analysis method. Finally, the dynamic model and sensitivity analysis results of the system were verified by experiments and co-simulation, respectively, and a sensitivity index was used to explain the sensitivity results comprehensively.
The remainder of this paper is organized as follows: In Section 2, a dynamic model of the helical rotary actuator is deduced, and a mathematical model of the closed-loop system is presented. The parameter sensitivity equation of the system is presented in Section 3. Details regarding the experiment and co-simulation verification are provided in Section 4. Finally, a summary is presented in Section 5.
Advertisement
2 Nonlinear Dynamic Model of System
The angular displacement closed-loop system of a valve-controlled HHRA is the research object of this study. In the following, the dynamic model of the rotary actuator is first established, and then the servo valve and proportional controller are introduced to establish the model of the entire hydraulic system.
2.1 Basic Operating Principle of HHRA
The basic structure of the designed HHRA is shown in Figure 1. It is primarily composed of a housing with an integral ring gear and two moving components: an output shaft and an annular piston sleeve. A1 and B1 represent the oil inlet and outlet, respectively. The helical spline teeth on the outside diameter of the piston engage in matching the splines of the housing ring gear (helical pair G1), and the inside diameter of the piston houses a second set of splines of the opposite hand, which engages the matching splines of the output shaft (helical pair G2). The seal ring on the piston segregates the housing into two independent chambers. When hydraulic pressure is applied, the piston actuates axially relative to the housing, similar to a hydraulic linear actuator. Simultaneously, owing to G1, the piston rotates and finally exhibits helical motion. When the piston is actuating helically, it drives the output shaft to rotate under the action of G2. Therefore, the rotational direction of the output shaft can be controlled by filling the pressure oil into different oil ports (A1 or B1).
×
2.2 Dynamic Model of HHRA
Based on the operating principle described in the previous section, the HHRA is schematically illustrated (as shown in Figure 2). It is composed of a piston (label 1), an output shaft (label 2), housing (label 3), and bearings (labels b1 and b2). The housing was fixed, and the axial displacement of the output shaft was limited by the bearings. The relative motion components are primarily G1 and G2, i.e., the helical motion of the piston and the rotation of the output shaft, respectively. To facilitate analysis, it is assumed that the pressure oil is introduced into the left chamber of the actuator, and the right chamber of the actuator returns oil. The motion states of the piston and shaft in this case are shown in Figure 2.
×
Kinematic analysis should first be performed prior to dynamic modelling. Because the HHRA is a system with one degree-of-freedom, once the displacement or rotation angle of the piston is determined, the motion state of the entire system can be determined. The state variables exhibit the following kinematic relationships:
where \({\varphi }_{1}\) is the rotation angle of the piston relative to the housing; \({\varphi }_{2}^{1}\) is the angle of the output shaft relative to the piston; \({\varphi }_{2}\) is the angle of the output shaft relative to the housing; xa1 is the axial displacement of the piston; S1 and S2 are the leads of G1 and G2, respectively. After obtaining the kinematic relationship, a mechanical analysis of the piston and output shaft was performed, an illustration of which is presented in Figure 3.
×
The forces and moments exerting on the piston are shown in Figure 3(a). Considering the coordinate system direction in the figure as the positive direction, the dynamic equations of the piston can be expressed as follows:
where Fhyd is the resultant force generated by the oil pressure in the two chambers of the actuator; m1 is the mass of the piston; J1 is the moment of inertia of the piston; F1,3 and F1,2 are the axial forces generated by G1 and G2 respectively; T1,3 and T1,2 are the torques generated by G1 and G2, respectively; f1,3 and Tf1,3 are the force and torque caused by friction between the seal ring on the piston and housing, respectively. The moments on the output shaft (as no movement exists in the axial direction of the output shaft, only the moments are presented herein) are shown in Figure 3(b). Considering the load characteristics, the dynamic equation is expressed as follows:
where T2,1 is the torque generated by G2; T2,1 = T1,2; T2,b1 and T2,b2 are the torques generated by the bearing friction; J2 is the moment of inertia of the output shaft and load; Bl is the load damping coefficient; Kl is the load stiffness coefficient; Tl is the external load torque. Meanwhile, forces F1,3, F1,2 and torques T1,3, T1,2 caused by G1 and G2 can be obtained via a mechanical analysis of the helical pair, as shown in Figure 4.
×
Because the effect of piston gravity on the helical pair depends on the installation position, to simplify the analysis, the output shaft is assumed to be installed horizontally; thus, the effect of gravity is negligible. As shown in Figures 4(a) and (b), F1,3, T1,3, F1,2, and T1,2 are calculated as follows:
where N1,3 and N1,2 are the normal forces produced by G1 and G2, respectively; μ1 and μ2 are the dynamic friction coefficients of G1 and G2, respectively; Ψ1 and Ψ2 are the helix angles of G1 and G2, respectively; d1 and d2 are the pitch diameters of G1 and G2, respectively. The resultant force generated by the oil pressure Fhyd can be expressed as
$$F_{{\rm{hyd}}} = (p_{1} - p_{2} )A_{\rm{p}} ,$$
(11)
where p1 is the oil pressure in the left chamber of the actuator, p2 the pressure in the right chamber, and Ap the effective action area of the piston. According to Eqs. (1)–(11), the dynamic equation of the HHRA can be expressed as follows:
In this study, an angle closed-loop system is investigated using a servo valve, and a schematic diagram of the valve-controlled actuator system is shown in Figure 5. The flow at the valve port is expressed as follows:
where xv denotes the valve spool displacement, ps the supply pressure, p0 the return oil pressure, and Kd the converted flow coefficient. Considering the effects of oil leakage and compressibility, the flow continuity equations for the HHRA can be written as follows:
where βe is the effective bulk modulus of the system; Vg1 and Vg2 are the volumes of the oil inlet and outlet channels connecting the valve and actuator, respectively; L is the maximum axial stroke of the piston; L0 is the initial axial position of the piston; Cip is the internal leakage coefficient of the actuator; Cep is the external leakage coefficient.
×
A second-order differential equation was used to approximate the dynamics of the servo valve, as follows:
where ζ is the damping ratio of the valve, ω the natural frequency of the valve, Kaxv the gain of the valve, and I the input signal of the valve. The characteristics of the angle closed-loop control can be expressed as follows:
$$I = K_{\rm{p}} (u - \varphi_{2} ),$$
(18)
where Kp is the gain of the P controller, and u is the input signal. The block diagram of the valve-controlled HHRA system based on the angular displacement closed-loop control is established using Eqs. (12)–(18), as shown in Figure 6.
×
The state-space equation is used to describe the sixth-order system, and the state variables are selected as follows:
\(\Delta_{2} = \frac{{[1 - {\text{sgn}} (x_{\rm{v}} )]p_{\rm{s}} }}{2} + \frac{{[ - 1 - {\text{sgn}} (x_{\rm{v}} )]p_{0} }}{2} + {\text{sgn}} (x_{\rm{v}} )p_{2}\), here, \({\varphi }_{20}\) is the initial angle of the output shaft, and \({\varphi }_{2\mathrm{max}}\) is the maximum angle of the output shaft.
3 Sensitivity Model and Analysis
The actual system parameters exhibit varying degrees of perturbation. When the system is sensitive to certain parameters, this perturbation will render the actual output significantly different from that of the mathematical model, which may result in deviation from the design requirements. Analyzing the parameter sensitivity allows us identify these key parameters such that the appropriate response measures can be implemented to reduce the parameter sensitivity or the parameters can be optimized. In this study, the first-order sensitivity method was selected to analyze the effect of 10% perturbation from the nominal parameter value on the rotation angle of the output shaft \({\varphi }_{2}\). This method is sufficiently accurate and allows an easier calculation than the high-order sensitivity method [29].
3.1 First-Order Trajectory Sensitivity Equation of System
Based on Eq. (19), many different types of parameters exist in the system dynamics model, including the structural parameters of the HHRA, operating parameters, parameters of the servo valve, and control parameters. The fluctuations of the different parameters are of different timescales. In this study, 23 main parameters in the system model were selected, which encompassed all types of parameters, as follows:
The actual structural parameters of the HHRA (α1–α13) are associated with the manufacturing errors and wear degree of the corresponding parts. Therefore, they will not change in the short term but may change after the system operates for a long time owing to wear. Owing to changes in the gas content, oil temperature, and load conditions, the operating parameters (α14–α19) are not constant but in a state of rapid dynamic fluctuation. Because the nonlinear high-order dynamic characteristics of the servo valve are simplified into a second-order differential equation, the real dynamic characteristics cannot be fully described. Therefore, the parameters of the servo valve (α20–α22) are not fixed and are affected by the input signal and operating parameters. The control parameter α23 must be dynamically adjusted with the change in system conditions to maintain the robustness of the system performance. Because the parameters above may exhibit different degrees of perturbation, the effects of the variations in the parameters above on the output characteristics of the system must be analyzed to improve the performance of the system.
The dynamics and sensitivity equations of the closed-loop system can be expressed as follows [20]:
where \({{\varvec{\lambda}}}^{{\varvec{i}}}={\left(\frac{\partial {\varvec{x}}}{\partial {\alpha }_{i}}\right)}_{{\varvec{\rm{n}}}}\) is the sensitivity function of parameter αi, i = 1,…,23.
Once the sensitivity functions are obtained, the variation of the state caused by parameter perturbation can be determined using the following equation (based on the Taylor theorem and disregarding higher-order terms):
To solve Eq. (20), the values of the nominal parameters are determined, as shown in Table 1. The structural parameters of HHRA are consistent with those in the three-dimensional (3D) model. The parameters of the servo valve were obtained from the dynamic characteristic curve in the stylebook. The values of the operating parameters, control parameters, and other parameters that are difficult to determine were selected based on application requirements and engineering experience.
Second, Eq. (20a) was established and solved using MATLAB SIMULINK to obtain the state x at every moment. The step input is generally believed to be the most severe operating state of the system; therefore, the step signal was used as the input signal to evaluate the dynamic performance of the system. The dynamic response characteristics of the system were different under different values of angular displacement and load conditions. Therefore, to encompass various operating conditions, step signals of 45°, 90°, and 135° were used as inputs, and the external load torques of “no load,” 100 N·m, and 200 N·m were used, respectively. The step response of the angular displacement closed-loop system was solved under nine operating conditions, all of which are listed in Table 2.
Table 2
Working conditions
Condition
Amplitude (°)
Load torque (N·m)
1
45
0
2
90
0
3
135
0
4
45
100
5
90
100
6
135
100
7
45
200
8
90
200
9
135
200
After solving the state equations, the state value of each moment within the calculation duration was obtained. The results were converted into the coefficient matrix and free matrix of Eq. (20b). Subsequently, using MATLAB, the fourth-order Runge–Kutta method was applied to solve the first-order trajectory sensitivity equations. Finally, the sensitivity functions of the angular displacement step response to 23 parameters were obtained under nine different conditions. Because the sensitivity function curves of some parameters are of different orders of magnitude under no-load and load conditions, for brevity, only the sensitivity function solutions of different step signals under no-load conditions are presented herein, as shown in Figure 7.
×
The curve in Figure 7 shows the dynamic sensitivity of each parameter to the rotation angle of the output shaft within 0.3 s. Owing to the different ranges of nominal values, the sensitivity functions of different parameters exhibit different orders of magnitude, rendering it difficult to intuitively compare the sensitivity of various parameters from the figure. Eq. (22) was used to clarify the results, and the variation in the angle was obtained based on the sensitivity function of different parameters to uniformly characterize the effect of each parameter. The effect of 10% fluctuation of each parameter on x1 under the nine conditions is illustrated in Figure 8.
×
As shown in Figure 8, under the no-load conditions, the parameters that are the most sensitive to the rotation angle are α12, α17, α22, and α23, in which the curves corresponding to α17, α22, and α23 are exactly the same. This is followed by parameters α3, α4, α18, α20, and α21, whereas the other parameters barely affect the rotation angle. However, as the load increases, parameters α5, α6, α9, and α10 becomes more sensitive gradually, and their effect on the rotation angle is not negligible. Meanwhile, some parameters fluctuated during the initial stage. The amplitude of the fluctuation increases with the load but decays rapidly. Only qualitative results can be obtained, and a more detailed quantitative analysis of the sensitivity of each parameter is presented in Section 4.3.
4 Experiment and Co-Simulation Verification
A valve-controlled actuator test platform was constructed to verify the accuracy of the system dynamics model in this study. Subsequently, the theoretical calculation results of parameter sensitivity were verified via co-simulation. To validate the theoretical sensitivity results, the effect of slight parameter changes on the system must be analyzed. However, slight changes in some parameters are difficult to measure accurately in the prototype experiment. For example, pressure pulsation occurs in the system pressure, and the pressure sensor may be affected by noise; therefore, accurately increasing or decreasing the pressure by approximately 10% is challenging. Moreover, the structural parameters or some operating parameters cannot be changed in the prototype experiment. Hence, the results of the sensitivity analysis were verified via co-simulation using MATLAB and Adams.
4.1 Dynamic Model Verification of Valve-Controlled HHRA System
The valve-controlled HHRA test platform and a schematic diagram of the system are shown in Figure 9. The closed-loop system primarily includes a rotary actuator, a servo valve, a valve controller, an encoder, diaphragm coupling, a magnetic powder brake, and auxiliary connections. One end of the output shaft of the actuator is equipped with the encoder, and the other end is connected to the brake through coupling. The encoder feeds back the angle signal to the valve controller, which processes the desired signal and feedback signal, and then outputs the control signal to the servo valve. The brake is used for loading, and the load torque can be set using its proprietary controller.
×
The setting of the experimental parameters is consistent with the nominal values presented in Table 1, and step response experiments were performed under the nine operating conditions. The rotation angle signal fed back by the encoder was written into the computer via an acquisition card, and the acquisition frequency was 1000 Hz. After filtering the data, step curves were obtained under all operating conditions, as shown in Figure 10(a). The rise time was regarded as the evaluation index of the system dynamic performance (i.e., the time when the initial value reaches 90% of the steady-state value), and the experimental results were compared with the calculation results of the theoretical model, as shown in Figure 10(b). The comparison results show that under various operating conditions, the maximum error between the theoretical rise time and the experimental value did not exceed 7%, which verifies the accuracy of the system dynamics model established in this study.
×
4.2 Verification of Sensitivity Solution Results
As mentioned above, the sensitivity solution was verified via co-simulation. First, the co-simulation model was established using MATLAB and Adams, and then four parameters showing rapid changes in the time scale were selected for sensitivity verification.
4.2.1 Co-Simulation Model
First, the 3D model was imported into Adams; subsequently, constraints and contacts were added. For the moving components, a revolute joint was added to the output shaft, and a cylindrical joint was added to the piston. For other components, such as the housing and bearings, fixed pairs were added. Contacts were added between the piston and output shaft, as well as between the piston and housing. Hertz contact theory was used to calculate the contact force, and the corresponding contact parameters are listed in Table 3.
Table 3
Setting of contact parameters
No.
Description
Value
Units
1
Stiffness
1 × 108
N/m
2
Force exponent
1.5
–
3
Damping
5 × 104
N·s/m
4
Penetration depth
1 × 10−4
m
5
Dynamic coefficient
0.005
–
The plant was controlled using Adams. The hydraulic thrust Fhyd was used as the input signal of the system, and the output signals were the rotation angle and angular velocity of the output shaft. Finally, by combining Eqs. (13)–(18) and the Adams control plant, the co-simulation model for the valve-controlled HHRA system was established in MATLAB SIMULINK, as shown in Figure 11. Next, the parameter sensitivity problem was solved using the co-simulation model and compared with the theoretical calculation results to complete the verification.
×
4.2.2 Verification of Parameter Sensitivity
To obtain the sensitivity solution from the co-simulation model, a certain parameter was changed by 10% while other parameters were maintained at the nominal value; subsequently, simulations were conducted to obtain the step response curve of the output shaft. By calculating the difference between the obtained curve and the curve prior to the parameter changes, the effect of the parameter change on the dynamic curve of the rotation angle was obtained and then compared with the results shown in Figure 8.
As mentioned in Section 3.2, parameters α3, α4, α5, α6, α9, α10, α12, α17, α18, α20, α21, α22, and α23 are more sensitive to the step response than the other parameters; therefore, these parameters should be prioritized. Parameters α3, α4, α5, α6, α9, α10, and α12 are the structural parameters of the actuator, which will not change in a short time under normal operating conditions, and the sensitivity curves of parameters α17, α22 and α23 in Figure 8 are exactly the same. Considering the parameters that change rapidly over time and for the convenience of expression, only parameters α18, α20, α21, and α23 were selected for verification. A comparison between the theoretical and co-simulation results is shown in Figures 12, 13, 14.
×
×
×
As shown by the curve, although the shapes of the theoretical and experimental curves are not completely consistent owing to the effects of the contact parameters, simulation step size, or other factors, the trend and range of the curves are similar for each parameter under different input conditions. This consistency proves the accuracy of the solution results of parameter sensitivity in the previous section and shows the effectiveness of using the first-order trajectory sensitivity analysis method to analyze the parameter sensitivity of the system. Because sensitivity analysis is used to evaluate the degree of influence of parameter variation on the system output, the slight error between the theoretical and experimental dynamic curves barely affects the analysis results. Therefore, the method proposed herein is applicable to the analysis of similar parameter sensitivity problems.
4.3 Analysis of Results
In this section, the sensitivity solution is analyzed more comprehensively. As shown in 8, the sensitivity function of each parameter changes with time. To quantify this dynamic process, a sensitivity index must first be determined. Farahat proposed four sensitivity indexes, among which the entirety index is reported to be the best index because it comprehensively considers all performance characteristics. In this study, the same index was used as the sensitivity index, and it is expressed as follows [21]:
Using Eq. (23), the curves in Figure 8 were integrated to obtain the sensitivity index values of the 23 parameters under nine operating conditions. The results are shown in Figures 15, 16, 17, where only parameters with a high sensitivity index are presented. Parameters whose sensitivity index is extremely low are omitted as their effects are negligible. The height of the column in the figure represents the integration of the absolute change in the output shaft rotation angle over the simulation time (0.3 s). Generally, the larger the height, the more sensitive is the output to the parameters.
×
×
×
As shown in Figures 15, 16, 17, when the system is under the same load conditions, the larger the step signal, the greater is the sensitivity index for a certain parameter. Moreover, the sensitivity index ranking of the parameters is the same when different step input signals are imposed. For the no-load condition, the order from high to low based on the sensitivity index of the parameters is as follows:
As indicated in Eqs. (24)–(29), when the system is under different load conditions, the sensitivity ranking of the parameters and the numerical relationship between the parameters change. To observe the changes in various parameters under different operating conditions, the sensitivity indices of the parameters under the nine operating conditions are summarized, as shown in Figure 18.
×
As shown in Figure 18, the sensitivity of each parameter increases with the step signal. However, as the system load increases, the sensitivity of some parameters (including S1, S2, Ψ1, Ψ1, d1, d2, Kd, ps, Kaxv, and Kp) increases, whereas the sensitivity of other parameters (including Ap, ω, and ζ) decreases. The sensitivity of the former parameters increases significantly, whereas that the latter parameters decreases slightly. For parameters Ψ1, Ψ2, d1, and d2 in particular, the order of magnitude of the sensitivity index is only 10−8 under the no-load condition; however, under a 200 N·m load, their sensitivity index values become tens of thousands of times that of the no-load condition.
5 Conclusions and Future Studies
In this study, a complete mathematical model of a valve-controlled HHRA system with an angular displacement closed loop was established. Subsequently, the influence degree and law of 10% parameter change on the angular displacement step response were quantitatively obtained using the first-order trajectory sensitivity analysis method. Finally, a prototype experiment and co-simulation were performed to verify the accuracy of the system dynamics model and sensitivity results, respectively. The good agreement between the theoretical and experimental (or co-simulation) values shows that the nonlinear system model established in this study can represent the dynamic characteristics of valve-controlled HHRA closed-loop systems effectively, and that the sensitivity equations are accurate. Therefore, the results of this study are reliable and can provide a basis for the structural parameter optimization or control compensation of similar systems. The conclusions of the sensitivity analysis are as follows:
(1)
An analysis of the sensitivity of the angular displacement closed-loop system when the parameters changed by 10% showed that the sensitivity ranking and values of the parameters were different under different operating conditions. In general, under the nine operating conditions involving different step inputs and loads described herein, the perturbation of structural parameters S1, S2, Ψ1, Ψ1, d1, d2, and Ap of the HHRA, operating parameters Kd and ps, servo valve parameters ω, ζ, and Kaxv, and the control parameter Kp significantly affected the dynamic characteristics of the system. Moreover, the sensitivity of these parameters increased significantly with an increase in the step input signal. For the other parameters, the effect of small-scale perturbations was negligible.
(2)
For structural parameters with high sensitivity, sensitivity can be reduced by selecting the appropriate parameters or optimizing the structure. For operating parameters with high sensitivity and rapid perturbation, their fluctuations must be reduced when designing the system. The parameters of the servo valve are highly sensitive; therefore, the values of the valve parameters used during modeling should be the same as those of the actual system because an incorrect value may cause significant deviation between the actual situation and design requirements. The control parameters are expected to significantly affect the system output because the dynamic characteristics of the system are often altered when the controller parameters are adjusted.
In future studies, the valve-controlled HHRA system designed in this study will be used to operate legged robots because the characteristics of helical hydraulic cylinders are suitable for high-speed robots, which require a compact structure and a high explosive force. In addition, to adapt the designed system to systems with different control performance requirements, a sensitivity analysis of the parameters of the system will be performed using different control algorithms.
Acknowledgements
The authors sincerely thank the engineers in Xiangyang Hangyu Electromechanical Hydraulic Application Technology Co. Ltd. for their assistance in processing and experimentation.
Competing Interests
The authors declare no competing financial interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.