Skip to main content
Top
Published in: Medical & Biological Engineering & Computing 8/2016

01-08-2016 | Original Article

On the computational implementation of forward and back-projection operations for cone-beam computed tomography

Authors: Davood Karimi, Rabab Ward

Published in: Medical & Biological Engineering & Computing | Issue 8/2016

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Forward- and back-projection operations are the main computational burden in iterative image reconstruction in computed tomography. In addition, their implementation has to be accurate to ensure stable convergence to a high-quality image. This paper reviews and compares some of the variations in the implementation of these operations in cone-beam computed tomography. We compare four algorithms for computing the system matrix, including a distance-driven algorithm, an algorithm based on cubic basis functions, another based on spherically symmetric basis functions, and a voxel-driven algorithm. The focus of our study is on understanding how the choice of the implementation of the system matrix will influence the performance of iterative image reconstruction algorithms, including such factors as the noise strength and spatial resolution in the reconstructed image. Our experiments with simulated and real cone-beam data reveal the significance of the speed–accuracy trade-off in the implementation of the system matrix. Our results suggest that fast convergence of iterative image reconstruction methods requires accurate implementation of forward- and back-projection operations, involving a direct estimation of the convolution of the footprint of the voxel basis function with the surface of the detectors. The required accuracy decreases by increasing the resolution of the projection measurements beyond the resolution of the reconstructed image. Moreover, reconstruction of low-contrast objects needs more accurate implementation of these operations. Our results also show that, compared with regularized reconstruction methods, the behavior of iterative reconstruction algorithms that do not use a proper regularization is influenced more significantly by the implementation of the forward- and back-projection operations.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Beck A, Teboulle M (2009) Fast gradient-based algorithms for constrained total variation image denoising and deblurring problems. Image Process IEEE Trans 18(11):2419–2434CrossRef Beck A, Teboulle M (2009) Fast gradient-based algorithms for constrained total variation image denoising and deblurring problems. Image Process IEEE Trans 18(11):2419–2434CrossRef
2.
go back to reference Buhr E, Günther-Kohfahl S, Neitzel U (2003) Simple method for modulation transfer function determination of digital imaging detectors from edge images. In: Medical Imaging 2003, International Society for Optics and Photonics, pp 877–884 Buhr E, Günther-Kohfahl S, Neitzel U (2003) Simple method for modulation transfer function determination of digital imaging detectors from edge images. In: Medical Imaging 2003, International Society for Optics and Photonics, pp 877–884
3.
go back to reference Chen Y, Yin X, Shi L, Shu H, Luo L, Coatrieux J-L, Toumoulin C (2013) Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing. Phys Med Biol 58(16):5803CrossRefPubMed Chen Y, Yin X, Shi L, Shu H, Luo L, Coatrieux J-L, Toumoulin C (2013) Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing. Phys Med Biol 58(16):5803CrossRefPubMed
4.
go back to reference Choi K, Wang J, Zhu L, Suh T-S, Boyd S, Xing L (2010) Compressed sensing based cone-beam computed tomography reconstruction with a first-order method. Med Phys 37(9):5113–5125CrossRefPubMedPubMedCentral Choi K, Wang J, Zhu L, Suh T-S, Boyd S, Xing L (2010) Compressed sensing based cone-beam computed tomography reconstruction with a first-order method. Med Phys 37(9):5113–5125CrossRefPubMedPubMedCentral
5.
go back to reference De Man B, Basu S (2002) Distance-driven projection and backprojection. In: Nuclear science symposium conference record, 2002 IEEE, vol 3, pp 1477–1480 De Man B, Basu S (2002) Distance-driven projection and backprojection. In: Nuclear science symposium conference record, 2002 IEEE, vol 3, pp 1477–1480
6.
go back to reference De Man B, Basu S (2004) Distance-driven projection and backprojection in three dimensions. Phys Med Biol 49(11):2463–2475CrossRefPubMed De Man B, Basu S (2004) Distance-driven projection and backprojection in three dimensions. Phys Med Biol 49(11):2463–2475CrossRefPubMed
7.
go back to reference Du LY, Umoh J, Nikolov HN, Pollmann SI, Lee TY, Holdsworth DW (2007) A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol 52(23):7087–7108CrossRefPubMed Du LY, Umoh J, Nikolov HN, Pollmann SI, Lee TY, Holdsworth DW (2007) A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol 52(23):7087–7108CrossRefPubMed
8.
go back to reference Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am A 1(6):612–619CrossRef Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am A 1(6):612–619CrossRef
9.
go back to reference Kim D, Ramani S, Fessler J (2015) Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction. Med Imaging IEEE Trans 34(1):167–178CrossRef Kim D, Ramani S, Fessler J (2015) Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction. Med Imaging IEEE Trans 34(1):167–178CrossRef
10.
go back to reference Kundel HL, Van Metter Richard L, Beutel Jacob (2000) Handbook of medical imaging, vol 1., Physics and psychophysicsSPIE publications, Bellingham Kundel HL, Van Metter Richard L, Beutel Jacob (2000) Handbook of medical imaging, vol 1., Physics and psychophysicsSPIE publications, Bellingham
11.
go back to reference Lewitt RM (1992) Alternatives to voxels for image representation in iterative reconstruction algorithms. Phys Med Biol 37(3):705CrossRefPubMed Lewitt RM (1992) Alternatives to voxels for image representation in iterative reconstruction algorithms. Phys Med Biol 37(3):705CrossRefPubMed
12.
go back to reference Long Y, Fessler J, Balter J (2010) 3D forward and back-projection for X-ray CT using separable footprints. Med Imaging IEEE Trans 29(11):1839–1850CrossRef Long Y, Fessler J, Balter J (2010) 3D forward and back-projection for X-ray CT using separable footprints. Med Imaging IEEE Trans 29(11):1839–1850CrossRef
13.
go back to reference Matej S, Lewitt R (1996) Practical considerations for 3-D image reconstruction using spherically symmetric volume elements. Med Imaging IEEE Trans 15(1):68–78. doi:10.1109/42.481442 CrossRef Matej S, Lewitt R (1996) Practical considerations for 3-D image reconstruction using spherically symmetric volume elements. Med Imaging IEEE Trans 15(1):68–78. doi:10.​1109/​42.​481442 CrossRef
14.
go back to reference Mueller K, Yagel R, Wheller J (1999) Fast implementations of algebraic methods for three-dimensional reconstruction from cone-beam data. Med Imaging IEEE Trans 18(6):538–548. doi:10.1109/42.781018 CrossRef Mueller K, Yagel R, Wheller J (1999) Fast implementations of algebraic methods for three-dimensional reconstruction from cone-beam data. Med Imaging IEEE Trans 18(6):538–548. doi:10.​1109/​42.​781018 CrossRef
15.
go back to reference Nielsen T, Ziegler A, Khler T, Proksa R (2010) Efficient projection and backprojection scheme for spherically symmetric basis functions in divergent beam geometry. Med Phys 33(12):4653–63 Nielsen T, Ziegler A, Khler T, Proksa R (2010) Efficient projection and backprojection scheme for spherically symmetric basis functions in divergent beam geometry. Med Phys 33(12):4653–63
16.
go back to reference Park JC, Song B, Kim JS, Park SH, Kim HK, Liu Z, Suh TS, Song WY (2012) Fast compressed sensing-based CBCT reconstruction using Barzilai–Borwein formulation for application to on-line IGRT. Med Phys 39(3):1207–1217CrossRefPubMed Park JC, Song B, Kim JS, Park SH, Kim HK, Liu Z, Suh TS, Song WY (2012) Fast compressed sensing-based CBCT reconstruction using Barzilai–Borwein formulation for application to on-line IGRT. Med Phys 39(3):1207–1217CrossRefPubMed
18.
go back to reference Tang J, Nett BE, Chen G-H (2009) Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol 54(19):5781CrossRefPubMedPubMedCentral Tang J, Nett BE, Chen G-H (2009) Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol 54(19):5781CrossRefPubMedPubMedCentral
19.
go back to reference Wang Z, Bovik A, Sheikh H, Simoncelli E (2004) Image quality assessment: from error visibility to structural similarity. Image Process IEEE Trans 13(4):600–612CrossRef Wang Z, Bovik A, Sheikh H, Simoncelli E (2004) Image quality assessment: from error visibility to structural similarity. Image Process IEEE Trans 13(4):600–612CrossRef
Metadata
Title
On the computational implementation of forward and back-projection operations for cone-beam computed tomography
Authors
Davood Karimi
Rabab Ward
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
Medical & Biological Engineering & Computing / Issue 8/2016
Print ISSN: 0140-0118
Electronic ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-015-1397-1

Other articles of this Issue 8/2016

Medical & Biological Engineering & Computing 8/2016 Go to the issue

Premium Partner