Skip to main content
Top
Published in: Fire Technology 4/2014

01-07-2014

Position of Maximum Ceiling Temperature in a Tunnel Fire

Authors: Ying Zhen Li, Haukur Ingason

Published in: Fire Technology | Issue 4/2014

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The position of the maximum ceiling gas temperature indicates how far the fire plum could be blown away by a ventilation flow. It could be applied to estimate the activation of a detection system or a sprinkler system, or to estimate the range of damage to the tunnel structure. An equation for predicting the position of the maximum ceiling gas temperature in a tunnel fire is proposed based on a theoretical analysis and validated using both laboratory test data and full scale test data. A flame angle has been defined based on the position of the maximum ceiling temperature in a tunnel fire. The flame angle is directly related to the dimensionless ventilation velocity, and it becomes insensitive to the heat release rate for a large tunnel fire. Further, it is found that a constant critical flame angle exists, defined as the flame angle under the critical condition when the backlayering just disappears. For a given tunnel and fire source, the flame angle under critical conditions is the same value, independent of heat release rate, and the maximum ceiling temperature under critical conditions always corresponds to the same position. Generally the horizontal distance between the position of the maximum ceiling temperature and the fire source centre is around 1.5 times the effective tunnel height under the critical condition.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference ISO (1999) Fire-resistance tests: elements of building construction—part 1: general requirements. International Organization for Standardization, Geneva ISO (1999) Fire-resistance tests: elements of building construction—part 1: general requirements. International Organization for Standardization, Geneva
2.
go back to reference European Committee for Standardization (1999) Fire resistance tests: part 2: alternative and additional procedures. European Committee for Standardization, Brussels European Committee for Standardization (1999) Fire resistance tests: part 2: alternative and additional procedures. European Committee for Standardization, Brussels
3.
go back to reference Instituut TNO voor Bouwmaterialen en Bouwconstructies (1979) Beproeving van het gedrag bij verhitting van twee isolatiematerialen ter bescherming van tunnels bij brand, Instituut TNO voor Bouwmaterialen en Bouwconstructies, B-79-391, Delft Instituut TNO voor Bouwmaterialen en Bouwconstructies (1979) Beproeving van het gedrag bij verhitting van twee isolatiematerialen ter bescherming van tunnels bij brand, Instituut TNO voor Bouwmaterialen en Bouwconstructies, B-79-391, Delft
4.
go back to reference Li YZ, Lei B, Ingason H (2011) The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires. Fire Saf J 46:204–210CrossRef Li YZ, Lei B, Ingason H (2011) The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires. Fire Saf J 46:204–210CrossRef
5.
go back to reference Li YZ, Ingason H (2012) The maximum ceiling gas temperature in a large tunnel fire. Fire Saf J 48:38–48CrossRef Li YZ, Ingason H (2012) The maximum ceiling gas temperature in a large tunnel fire. Fire Saf J 48:38–48CrossRef
6.
go back to reference American Gas Association (1974) LNG safety research program, report IS 3-1. American Gas Association, Washington, DC American Gas Association (1974) LNG safety research program, report IS 3-1. American Gas Association, Washington, DC
7.
go back to reference Kurioka H, Oka Y, Satoh H, Sugawa O (2003) Fire properties in near field of square fire source with longitudinal ventilation in tunnels. Fire Saf J 38:319–340CrossRef Kurioka H, Oka Y, Satoh H, Sugawa O (2003) Fire properties in near field of square fire source with longitudinal ventilation in tunnels. Fire Saf J 38:319–340CrossRef
8.
go back to reference Quintiere JG, Rinkinen WJ, Jones WW (1981) The effect of room openings on fire plume entrainment. Combust Sci Technol 26:193–201CrossRef Quintiere JG, Rinkinen WJ, Jones WW (1981) The effect of room openings on fire plume entrainment. Combust Sci Technol 26:193–201CrossRef
9.
go back to reference Karlsson B, Quintiere JG (2000) Enclosure fire dynamics. CRC Press, Washington DC, pp 53–64 Karlsson B, Quintiere JG (2000) Enclosure fire dynamics. CRC Press, Washington DC, pp 53–64
10.
go back to reference Li YZ, Lei B, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Saf J 45(6–8):361–370CrossRef Li YZ, Lei B, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Saf J 45(6–8):361–370CrossRef
11.
go back to reference Ingason H, Li YZ (2010) Model scale tunnel fire tests with longitudinal ventilation. Fire Saf J 45(6–8):371–384CrossRef Ingason H, Li YZ (2010) Model scale tunnel fire tests with longitudinal ventilation. Fire Saf J 45(6–8):371–384CrossRef
12.
go back to reference Quintiere JG (1989) Scaling applications in fire research. Fire Saf J 15:3–29CrossRef Quintiere JG (1989) Scaling applications in fire research. Fire Saf J 15:3–29CrossRef
13.
go back to reference Heskestad G (1975) Physical modeling of fire. J Fire Flammabil 6:253–273 Heskestad G (1975) Physical modeling of fire. J Fire Flammabil 6:253–273
14.
go back to reference Li YZ, Ingason H (2010) Maximum ceiling temperature in a tunnel fire. SP report 2010:51. SP Technical and Research Institute of Sweden, Boras Li YZ, Ingason H (2010) Maximum ceiling temperature in a tunnel fire. SP report 2010:51. SP Technical and Research Institute of Sweden, Boras
15.
go back to reference Ingason H, Lönnermark A(2005) Heat release rates from heavy goods vehicle trailers in tunnels. Fire Saf J 40:646–668CrossRef Ingason H, Lönnermark A(2005) Heat release rates from heavy goods vehicle trailers in tunnels. Fire Saf J 40:646–668CrossRef
16.
go back to reference Lönnermark A, Ingason H (2005) Gas temperatures in heavy goods vehicle fires in tunnels. Fire Saf J 40:506–527CrossRef Lönnermark A, Ingason H (2005) Gas temperatures in heavy goods vehicle fires in tunnels. Fire Saf J 40:506–527CrossRef
17.
go back to reference Lönnermark A, Ingason H (2006) Fire spread and flame length in large-scale tunnel fires. Fire Technol 42:283–302CrossRef Lönnermark A, Ingason H (2006) Fire spread and flame length in large-scale tunnel fires. Fire Technol 42:283–302CrossRef
18.
go back to reference FHWA (1995) Memorial tunnel fire ventilation test program—test report. Massachusetts Highway Department and Federal Highway Administration, Massachusetts FHWA (1995) Memorial tunnel fire ventilation test program—test report. Massachusetts Highway Department and Federal Highway Administration, Massachusetts
19.
go back to reference Lemaire T, van de Leur PHE, Kenyon YM (2002) Safety proef: TNO metingen beneluxtunnel—meetrapport. TNO, TNO-rapport 2002-CVB-R05572. TNO, Amsterdam Lemaire T, van de Leur PHE, Kenyon YM (2002) Safety proef: TNO metingen beneluxtunnel—meetrapport. TNO, TNO-rapport 2002-CVB-R05572. TNO, Amsterdam
20.
go back to reference Lemaire T, Kenyon Y (2006) Large scale fire tests in the Second Benelux tunnel. Fire Technol 42:329–350CrossRef Lemaire T, Kenyon Y (2006) Large scale fire tests in the Second Benelux tunnel. Fire Technol 42:329–350CrossRef
Metadata
Title
Position of Maximum Ceiling Temperature in a Tunnel Fire
Authors
Ying Zhen Li
Haukur Ingason
Publication date
01-07-2014
Publisher
Springer US
Published in
Fire Technology / Issue 4/2014
Print ISSN: 0015-2684
Electronic ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-012-0309-2

Other articles of this Issue 4/2014

Fire Technology 4/2014 Go to the issue