Abstract

Purpose

Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges.

Method

A convenient and efficient calibration phantom is designed by combining the traditional calibration object of X-ray images with a checkerboard plane. After the localization of the 2D marker points in the X-ray images and the corresponding 3D points from the RGB-D images, we calculate the projection matrix from the RGB-D sensor coordinates to the X-ray, instead of estimating the extrinsic and intrinsic parameters simultaneously.

Validation

In order to evaluate the effect of every step of our calibration process, we performed five experiments by combining different steps leading to the calibration. We also compared our calibration method to Tsai’s method to evaluate the advancement of our solution. At last, we simulated the process of estimating the rotation movement of the RGB-D camera using MATLAB and demonstrate that calculating the projection matrix can reduce the angle error of the rotation.

Results

A RMS reprojection error of 0.5 mm is achieved using our calibration method which is promising for surgical applications. Our calibration method is more accurate when compared to Tsai’s method. Lastly, the simulation result shows that using a projection matrix has a lower error than using intrinsic and extrinsic parameters in the rotation estimation.

Conclusions

We designed and evaluated a 3D/2D calibration method for the combination of a RGB-D camera and a C-arm fluoroscope.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Kersten-Oertel M, Jannin P, Collins DL (2012) DVV: a taxonomy for mixed reality visualization in image guided surgery. IEEE Trans Vis Comput Graph 18(2):332–352CrossRefPubMed Kersten-Oertel M, Jannin P, Collins DL (2012) DVV: a taxonomy for mixed reality visualization in image guided surgery. IEEE Trans Vis Comput Graph 18(2):332–352CrossRefPubMed
2.
go back to reference Navab N, Blum T, Wang L, Okur A, Wendler T (2012) First deployments of augmented reality in operating rooms. Comput IEEE Comput Soc 7:48–55CrossRef Navab N, Blum T, Wang L, Okur A, Wendler T (2012) First deployments of augmented reality in operating rooms. Comput IEEE Comput Soc 7:48–55CrossRef
3.
go back to reference Ewers R, Schicho K, Wagner A, Undt G, Seemann R, Figl M, Truppe M (2005) Seven years of clinical experience with teleconsultation in craniomaxillofacial surgery. J Oral Maxillofac Surg 63:1447–1454CrossRefPubMed Ewers R, Schicho K, Wagner A, Undt G, Seemann R, Figl M, Truppe M (2005) Seven years of clinical experience with teleconsultation in craniomaxillofacial surgery. J Oral Maxillofac Surg 63:1447–1454CrossRefPubMed
4.
go back to reference Johnson LG, Edwards P, Hawkes D (2003) Surface transparency makes stereo overlays unpredictable: the implications for augmented reality. Stud Health Technol Inform 94:131–136 Johnson LG, Edwards P, Hawkes D (2003) Surface transparency makes stereo overlays unpredictable: the implications for augmented reality. Stud Health Technol Inform 94:131–136
5.
go back to reference Bauer S, Seitel A, Hofmann H, Blum T, Wasza J, Balda M, Meinzer HP, Navab N, Hornegger J, Maier-Hein L (2013) Real-time range imaging in health care: a survey. In: Grzegorzek M, Theobalt C, Koch R, Kolb A (eds) Time-of-flight and depth imaging. Sensors, algorithms, and applications. Springer, Berlin, Heidelberg, pp 228–254 Bauer S, Seitel A, Hofmann H, Blum T, Wasza J, Balda M, Meinzer HP, Navab N, Hornegger J, Maier-Hein L (2013) Real-time range imaging in health care: a survey. In: Grzegorzek M, Theobalt C, Koch R, Kolb A (eds) Time-of-flight and depth imaging. Sensors, algorithms, and applications. Springer, Berlin, Heidelberg, pp 228–254
6.
go back to reference Wang XL, Stolka PJ, Boctor E, Hager G, Choti M (2012) The Kinect as an interventional tracking system. In: David R. Holmes III, Kenneth H. Wong (eds) SPIE medical imaging 2012: image-guided procedures, robotic interventions and modeling, vol 8316. SPIE, San Diego, California, USA, pp 83160U-83160U-6 Wang XL, Stolka PJ, Boctor E, Hager G, Choti M (2012) The Kinect as an interventional tracking system. In: David R. Holmes III, Kenneth H. Wong (eds) SPIE medical imaging 2012: image-guided procedures, robotic interventions and modeling, vol 8316. SPIE, San Diego, California, USA, pp 83160U-83160U-6
7.
go back to reference Kontschieder P, Dorn JF, Morrison C, Corish R, Zikic D, Sellen A, D’Souza M, Kamm CP, Burggraaff J, Tewarie P, Vogel T, Azzarito M, Glocker B, Dahlke P, Polman C, Kappos L, Uitdehaag B, Criminisi A (2014) Quantifying progression of multiple sclerosis via classification of depth videos. In: Golland P, Hata N, Barillot C, Hornegger J, Howe R (eds) Medical image computing and computer-assisted intervention—MICCAI 2014, vol 8674. Springer International Publishing, Switzerland, pp 429–437 Kontschieder P, Dorn JF, Morrison C, Corish R, Zikic D, Sellen A, D’Souza M, Kamm CP, Burggraaff J, Tewarie P, Vogel T, Azzarito M, Glocker B, Dahlke P, Polman C, Kappos L, Uitdehaag B, Criminisi A (2014) Quantifying progression of multiple sclerosis via classification of depth videos. In: Golland P, Hata N, Barillot C, Hornegger J, Howe R (eds) Medical image computing and computer-assisted intervention—MICCAI 2014, vol 8674. Springer International Publishing, Switzerland, pp 429–437
8.
go back to reference Alnowami M, Alnwaimi B, Tahavori F, Copland M, Wells K (2012) A quantitative assessment of using the Kinect for Xbox360 for respiratory surface motion tracking. In: David R. Holmes III, Kenneth H. Wong (eds) SPIE medical imaging, international society for optics and photonics, SPIE, San Diego, California, USA, pp 83161T–83161T-10 Alnowami M, Alnwaimi B, Tahavori F, Copland M, Wells K (2012) A quantitative assessment of using the Kinect for Xbox360 for respiratory surface motion tracking. In: David R. Holmes III, Kenneth H. Wong (eds) SPIE medical imaging, international society for optics and photonics, SPIE, San Diego, California, USA, pp 83161T–83161T-10
9.
go back to reference Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334CrossRef
11.
go back to reference Yaniv Z, Joskowicz L, Simkin A, Garza-Jinich M, Milgrom C (1998) Fluoroscopic image processing for computer-aided orthopaedic surgery. In: Wells WM, Colchester A, Delp S (eds) Medical image computing and computer-assisted interventation—MICCAI’98, vol 1496. Springer, Berlin, Heidelberg, pp 325–334 Yaniv Z, Joskowicz L, Simkin A, Garza-Jinich M, Milgrom C (1998) Fluoroscopic image processing for computer-aided orthopaedic surgery. In: Wells WM, Colchester A, Delp S (eds) Medical image computing and computer-assisted interventation—MICCAI’98, vol 1496. Springer, Berlin, Heidelberg, pp 325–334
12.
go back to reference Livyatan H, Yaniv Z, Joskowicz L (2002) Robust automatic C-arm calibration for fluoroscopy-based navigation: a practical approach. In: Dohi T, Kikinis R (eds) Medical image computing and computer-assisted intervention–MICCAI 2002, vol 2489. Springer, Berlin, Heidelberg, pp 60–68 Livyatan H, Yaniv Z, Joskowicz L (2002) Robust automatic C-arm calibration for fluoroscopy-based navigation: a practical approach. In: Dohi T, Kikinis R (eds) Medical image computing and computer-assisted intervention–MICCAI 2002, vol 2489. Springer, Berlin, Heidelberg, pp 60–68
13.
go back to reference Meng C, Zhang J, Zhou F, Wang T (2014) New method for geometric calibration and distortion correction of conventional C-arm. Comput Biol Med 52:49–56CrossRefPubMed Meng C, Zhang J, Zhou F, Wang T (2014) New method for geometric calibration and distortion correction of conventional C-arm. Comput Biol Med 52:49–56CrossRefPubMed
14.
go back to reference Shechter G, Devernay F, Coste-Manière E, McVeigh ER (2002) Temporal tracking of 3D coronary arteries in projection angiograms. In: Medical imaging 2002, international society for optics and photonics. pp 612–623 Shechter G, Devernay F, Coste-Manière E, McVeigh ER (2002) Temporal tracking of 3D coronary arteries in projection angiograms. In: Medical imaging 2002, international society for optics and photonics. pp 612–623
15.
go back to reference Shechter G, Shechter B, Resar JR, Beyar R (2005) Prospective motion correction of X-ray images for coronary interventions. IEEE Trans Med Imaging 24(4):441–450CrossRefPubMed Shechter G, Shechter B, Resar JR, Beyar R (2005) Prospective motion correction of X-ray images for coronary interventions. IEEE Trans Med Imaging 24(4):441–450CrossRefPubMed
16.
go back to reference Tsai R (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lens. IEEE J Robot Autom 3:323–344CrossRef Tsai R (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lens. IEEE J Robot Autom 3:323–344CrossRef
17.
go back to reference Jung J, Lee JY, Jeong Y, Kweon IS (2014) Time-of-flight sensor calibration for a color and depth camera pair. IEEE Trans Pattern Anal Mach Intell 37(7):1501–1513CrossRef Jung J, Lee JY, Jeong Y, Kweon IS (2014) Time-of-flight sensor calibration for a color and depth camera pair. IEEE Trans Pattern Anal Mach Intell 37(7):1501–1513CrossRef
18.
go back to reference Shime H, Adelsberger R, Kim JD, Rhee SM, Rhee T, Sim JY, Gross M, Kim C (2012) Time-of-flight sensor and color camera calibration for multi-view acquisition. Vis Comput 28:1139–1151CrossRef Shime H, Adelsberger R, Kim JD, Rhee SM, Rhee T, Sim JY, Gross M, Kim C (2012) Time-of-flight sensor and color camera calibration for multi-view acquisition. Vis Comput 28:1139–1151CrossRef
19.
go back to reference Zhang C, Zhang Z (2014) Calibration between depth and color sensors for commodity depth cameras. In: Shao L, Han J, Kohli P, Zhang Z (eds) Computer vision and machine learning with RGB-D sensors. Springer International Publishing, Switzerland, pp 47–64 Zhang C, Zhang Z (2014) Calibration between depth and color sensors for commodity depth cameras. In: Shao L, Han J, Kohli P, Zhang Z (eds) Computer vision and machine learning with RGB-D sensors. Springer International Publishing, Switzerland, pp 47–64
20.
go back to reference Herrera C, Kannala J, Heikkilä J (2012) Joint depth and color camera calibration with distortion correction. IEEE Trans Pattern Anal Mach Intell 34(10):2058–8828CrossRef Herrera C, Kannala J, Heikkilä J (2012) Joint depth and color camera calibration with distortion correction. IEEE Trans Pattern Anal Mach Intell 34(10):2058–8828CrossRef
21.
go back to reference Raposo C, Barreto JP, Nunes U (2013) Fast and accurate calibration of a Kinect sensor. In: International conference on 3D vision—3DV. pp 342–349 Raposo C, Barreto JP, Nunes U (2013) Fast and accurate calibration of a Kinect sensor. In: International conference on 3D vision—3DV. pp 342–349
22.
go back to reference Horaud R, Dornaika F (1995) Hand-eye calibration. Int J Robot Res 14(3):195–210CrossRef Horaud R, Dornaika F (1995) Hand-eye calibration. Int J Robot Res 14(3):195–210CrossRef
23.
go back to reference Mitschke MM, Navab N (2000) Recovering projection geometry: how a cheap camera can outperform an expensive stereo system. In: IEEE conference on computer vision and pattern recognition (CVPR), vol. 1. pp 193–200 Mitschke MM, Navab N (2000) Recovering projection geometry: how a cheap camera can outperform an expensive stereo system. In: IEEE conference on computer vision and pattern recognition (CVPR), vol. 1. pp 193–200
24.
go back to reference Navab N, Bani-Hashemi A, Nadar MS, Wiesent K, Durlak P, Brunner T, Barth K, Graumann R (1998) 3D Reconstruction from projection matrices in a C-arm based 3D-angiography system. In: Wells WM, Colchester A, Delp S (eds) Medical image computing and computer assisted interventation—MICCAI’98, vol 1496. Springer, Berlin, Heidelberg, pp 119–129 Navab N, Bani-Hashemi A, Nadar MS, Wiesent K, Durlak P, Brunner T, Barth K, Graumann R (1998) 3D Reconstruction from projection matrices in a C-arm based 3D-angiography system. In: Wells WM, Colchester A, Delp S (eds) Medical image computing and computer assisted interventation—MICCAI’98, vol 1496. Springer, Berlin, Heidelberg, pp 119–129
25.
go back to reference Yang L, Zhang L, Dong H, Alelaiwi A, Saddik AE (2015) Evaluating and improving the depth accuracy of Kinect for Windows v2. IEEE Sens J 15(8):4275–4285CrossRef Yang L, Zhang L, Dong H, Alelaiwi A, Saddik AE (2015) Evaluating and improving the depth accuracy of Kinect for Windows v2. IEEE Sens J 15(8):4275–4285CrossRef
26.
go back to reference Kedgley AE, Fox AV, Jenkyn TR (2012) Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment. J Appl Clin Med Phys 13(1):197–204 Kedgley AE, Fox AV, Jenkyn TR (2012) Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment. J Appl Clin Med Phys 13(1):197–204
27.
go back to reference Navab N, Mitschke M (2001) Method and apparatus using a virtual detector for three-dimensional reconstruction from X-ray images. Patent US 6236704; Filing date: June 30, 1999; Issue date: May 22 Navab N, Mitschke M (2001) Method and apparatus using a virtual detector for three-dimensional reconstruction from X-ray images. Patent US 6236704; Filing date: June 30, 1999; Issue date: May 22
28.
go back to reference Huhle B, Schairer T, Jenke P, Strasser W (2008) Robust non-local denosing of colored depth data. In: IEEE computer society conference on computer vision and pattern recognition workshops (CVPRW’08). pp 1–7 Huhle B, Schairer T, Jenke P, Strasser W (2008) Robust non-local denosing of colored depth data. In: IEEE computer society conference on computer vision and pattern recognition workshops (CVPRW’08). pp 1–7
29.
go back to reference Essmaeel K, Gallo L, Damiani E, De Pietro G, Dipanda A (2012) Temporal denoising of Kinect depth data. In: 2012 Eighth international conference on signal image technology and internet based systems (SITIS). pp 47–52 Essmaeel K, Gallo L, Damiani E, De Pietro G, Dipanda A (2012) Temporal denoising of Kinect depth data. In: 2012 Eighth international conference on signal image technology and internet based systems (SITIS). pp 47–52
30.
go back to reference Hartley R, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, CambridgeCrossRef Hartley R, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, CambridgeCrossRef
31.
go back to reference Moré JJ (1978) The Levenberg–Marquardt algorithm: implementation and theory. In: Watson GA (ed) Numerical analysis. Springer, Berlin, Heidelberg, pp 105–116 Moré JJ (1978) The Levenberg–Marquardt algorithm: implementation and theory. In: Watson GA (ed) Numerical analysis. Springer, Berlin, Heidelberg, pp 105–116
33.
go back to reference Golub GH, Van Loan CF (1996) Matrix computation, 3rd edn. Johns Hopkins University Press, Baltimore Golub GH, Van Loan CF (1996) Matrix computation, 3rd edn. Johns Hopkins University Press, Baltimore
35.
go back to reference Huynh DQ (2009) Metrics for 3D rotation: comparison and analysis. J Math Imaging Vis 35:155–164CrossRef Huynh DQ (2009) Metrics for 3D rotation: comparison and analysis. J Math Imaging Vis 35:155–164CrossRef
36.
go back to reference Pauly O, Diotte B, Fallavollita P, Weidert S, Euler E, Navab N (2015) Machine learning-based augmented reality for improved surgical scene understanding. Comput Med Imaging Graph 41:55–60CrossRefPubMed Pauly O, Diotte B, Fallavollita P, Weidert S, Euler E, Navab N (2015) Machine learning-based augmented reality for improved surgical scene understanding. Comput Med Imaging Graph 41:55–60CrossRefPubMed
37.
go back to reference Pauly O, Diotte B, Habert S, Weidert S, Euler E, Fallavollita P, Navab N (2014). Relevance-based visualization to improve surgeon perception. In: Stoyanov D, Collins DL, Sakuma I, Abolmaesumi P, Jannin P (eds) Information processing in computer-assisted interventions, vol 8498. Springer International Publishing, Switzerland, pp 178–185 Pauly O, Diotte B, Habert S, Weidert S, Euler E, Fallavollita P, Navab N (2014). Relevance-based visualization to improve surgeon perception. In: Stoyanov D, Collins DL, Sakuma I, Abolmaesumi P, Jannin P (eds) Information processing in computer-assisted interventions, vol 8498. Springer International Publishing, Switzerland, pp 178–185
38.
go back to reference Pauly O, Katouzian A, Eslami A, Fallavollita P, Navab N (2012). Supervised classification for customized intraoperative augmented reality visualization. In: 2012 IEEE international symposium on mixed and augmented reality (ISMAR). IEEE, pp 311–312 Pauly O, Katouzian A, Eslami A, Fallavollita P, Navab N (2012). Supervised classification for customized intraoperative augmented reality visualization. In: 2012 IEEE international symposium on mixed and augmented reality (ISMAR). IEEE, pp 311–312
39.
go back to reference Wieczorek M, Aichert A, Fallavollita P, Kutter O, Ahmadi A, Wang L, Navab N (2011) Interactive 3D visualization of a single-view X-ray image. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention-MICCAI 2011, vol 6891. Springer, Berlin, Heidelberg, pp 73–80 Wieczorek M, Aichert A, Fallavollita P, Kutter O, Ahmadi A, Wang L, Navab N (2011) Interactive 3D visualization of a single-view X-ray image. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention-MICCAI 2011, vol 6891. Springer, Berlin, Heidelberg, pp 73–80
40.
go back to reference Erat O, Pauly O, Weidert S, Thaller P, Euler E, Mutschler W, et al (2013) How a surgeon becomes superman by visualization of intelligently fused multi-modalities. In: David R. Holmes, Ziv R. Yaniv (eds) SPIE medical imaging. International Society for Optics and Photonics, vol 8671. SPIE, Florida, USA, pp 86710L–86710L-6 Erat O, Pauly O, Weidert S, Thaller P, Euler E, Mutschler W, et al (2013) How a surgeon becomes superman by visualization of intelligently fused multi-modalities. In: David R. Holmes, Ziv R. Yaniv (eds) SPIE medical imaging. International Society for Optics and Photonics, vol 8671. SPIE, Florida, USA, pp 86710L–86710L-6
41.
go back to reference Wang L, Fallavollita P, Brand A, Erat O, Weidert S, Thaller PH et al (2012) Intra-op measurement of the mechanical axis deviation: an evaluation study on 19 human cadaver legs. In: Ayache N, Delingette H, Golland P, Mori K (eds) Medical image computing and computer-assisted intervention—MICCAI 2012. Springer, Berlin, Heidelberg, pp 609–616 Wang L, Fallavollita P, Brand A, Erat O, Weidert S, Thaller PH et al (2012) Intra-op measurement of the mechanical axis deviation: an evaluation study on 19 human cadaver legs. In: Ayache N, Delingette H, Golland P, Mori K (eds) Medical image computing and computer-assisted intervention—MICCAI 2012. Springer, Berlin, Heidelberg, pp 609–616
42.
go back to reference Diotte B, Fallavollita P, Wang L, Weidert S, Euler E, Thaller P, Navab N (2015) Multi-modal intra-operative navigation during distal locking of intramedullary nails. Med Imaging IEEE Trans 34(2):487–495CrossRef Diotte B, Fallavollita P, Wang L, Weidert S, Euler E, Thaller P, Navab N (2015) Multi-modal intra-operative navigation during distal locking of intramedullary nails. Med Imaging IEEE Trans 34(2):487–495CrossRef
43.
go back to reference Londei R, Esposito M, Diotte B, Weidert S, Euler E, Thaller P, et al (2014) The ‘augmented’circles: a video-guided solution for the down-the-beam positioning of IM nail holes. In: Stoyanov D, Collins DL, Sakuma I, Abolmaesumi P, Jannin P (eds) Information processing in computer-assisted interventions, vol 8498. Springer International Publishing, Switzerland, pp 100–107 Londei R, Esposito M, Diotte B, Weidert S, Euler E, Thaller P, et al (2014) The ‘augmented’circles: a video-guided solution for the down-the-beam positioning of IM nail holes. In: Stoyanov D, Collins DL, Sakuma I, Abolmaesumi P, Jannin P (eds) Information processing in computer-assisted interventions, vol 8498. Springer International Publishing, Switzerland, pp 100–107
44.
go back to reference Londei R, Esposito M, Diotte B, Weidert S, Euler E, Thaller P, et al (2015) Intra-operative augmented reality in distal locking. Int J Comput Assist Radiol Surg 10(9):1395–1403 Londei R, Esposito M, Diotte B, Weidert S, Euler E, Thaller P, et al (2015) Intra-operative augmented reality in distal locking. Int J Comput Assist Radiol Surg 10(9):1395–1403
Metadata
Title
Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope
Authors
Xiang Wang
Severine Habert
Meng Ma
Chun-Hao Huang
Pascal Fallavollita
Nassir Navab
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 8/2016
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1347-2

Other articles of this Issue 8/2016

International Journal of Computer Assisted Radiology and Surgery 8/2016 Go to the issue

Premium Partner