Preliminary Study of a Low-Cost Point-of-Care Testing System Using Screen-Printed Biosensors for Early Biomarkers Detection Related to Alzheimer Disease

Authors : Sarah Tonello, Mauro Serpelloni, Nicola Francesco Lopomo, Giulia Abate, Daniela Letizia Uberti, Emilio Sardini

Published in: Sensors

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Among neurodegenerative diseases, Alzheimer Disease (AD) represents one of the most widespread pathologies, for which an early diagnosis is still missing. A peculiar expression of an altered conformational isoform of p53 protein was reported to be a potential biomarker able to distinguish AD subjects from healthy population, quantifiable using a blood-based enzyme-linked immunosorbent assay (ELISA). In order to overcome ELISA limitations, related to reliability and to improve sensitivity, this study aimed to realize a low cost highly sensitive portable point-of-care (PoC) testing system based on screen printed electrochemical sensors (SPES). The development of the platform specifically included both the design of the sensing probe and of the electronic circuit devoted to the conditioning and acquisition of the transduced electric signal. Preliminary testing of the circuit were performed recording changes in the conductivity of NaCl solution and quantifying electrodes coating with antibodies using Electrochemical Impedance Spectroscopy (EIS) principle. Results obtained with saline solution, showed the ability of the circuit to give the best response corresponding to low changes in NaCl concentration (sensitivity 0.2 mA/(mg/ml)), suggesting a good sensitivity of the platform. Findings obtained from EIS showed the ability of the circuit to discriminate between different concentrations of antibodies coatings (sensitivity 80 µA/µg). Preliminary calibration of the sensor using interleukin IL-8 showed an increase in the maximum peak of current proportional to the increase of protein concentration, achieving a sensitivity of 35 µA/ng and reporting also a good value of reproducibility, really promising in the perspective of lower values of proteins concentrations.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Z. Svobodova, M. Reza Mohamadi, B. Jankovicova, H. Esselmann, R. Verpillot, M. Otto, M. Taverna, J. Wiltfang, J.-L. Viovy, Z. Bilkova, Development of a magnetic immunosorbent for on-chip preconcentration of amyloid beta isoforms: representatives of Alzheimer’s disease biomarkers. Biomicrofluidics 6(2), 24126–2412612 (2012) Z. Svobodova, M. Reza Mohamadi, B. Jankovicova, H. Esselmann, R. Verpillot, M. Otto, M. Taverna, J. Wiltfang, J.-L. Viovy, Z. Bilkova, Development of a magnetic immunosorbent for on-chip preconcentration of amyloid beta isoforms: representatives of Alzheimer’s disease biomarkers. Biomicrofluidics 6(2), 24126–2412612 (2012)
2.
go back to reference C. Humpel, Identifying and validating biomarkers for Alzheimer’s disease. Trends Biotechnol. 29(1), 26–32 (2011)CrossRef C. Humpel, Identifying and validating biomarkers for Alzheimer’s disease. Trends Biotechnol. 29(1), 26–32 (2011)CrossRef
3.
go back to reference D. Uberti, C. Lanni, T. Carsana, S. Francisconi, C. Missale, M. Racchi, S. Govoni, M. Memo, Identification of a mutant-like conformation of p53 in fibroblasts from sporadic Alzheimer’s disease patients. Neurobiol. Aging 27(9), 1193–1201 (2006)CrossRef D. Uberti, C. Lanni, T. Carsana, S. Francisconi, C. Missale, M. Racchi, S. Govoni, M. Memo, Identification of a mutant-like conformation of p53 in fibroblasts from sporadic Alzheimer’s disease patients. Neurobiol. Aging 27(9), 1193–1201 (2006)CrossRef
4.
go back to reference C. Lanni, M. Racchi, G. Mazzini, A. Ranzenigo, R. Polotti, E. Sinforiani, L. Olivari, M. Barcikowska, M. Styczynska, J. Kuznicki, A. Szybinska, S. Govoni, M. Memo, D. Uberti, Conformationally altered p53: a novel Alzheimer’s disease marker? Mol. Psychiatry 13(6), 641–647 (2008)CrossRef C. Lanni, M. Racchi, G. Mazzini, A. Ranzenigo, R. Polotti, E. Sinforiani, L. Olivari, M. Barcikowska, M. Styczynska, J. Kuznicki, A. Szybinska, S. Govoni, M. Memo, D. Uberti, Conformationally altered p53: a novel Alzheimer’s disease marker? Mol. Psychiatry 13(6), 641–647 (2008)CrossRef
5.
go back to reference L. Buizza, G. Cenini, C. Lanni, G. Ferrari-Toninelli, C. Prandelli, S. Govoni, E. Buoso, M. Racchi, M. Barcikowska, M. Styczynska, A. Szybinska, D.A. Butterfield, M. Memo, D. Uberti, Conformational altered p53 as an early marker of oxidative stress in Alzheimer’s disease. PLoS ONE 7(1), e29789 (2012)CrossRef L. Buizza, G. Cenini, C. Lanni, G. Ferrari-Toninelli, C. Prandelli, S. Govoni, E. Buoso, M. Racchi, M. Barcikowska, M. Styczynska, A. Szybinska, D.A. Butterfield, M. Memo, D. Uberti, Conformational altered p53 as an early marker of oxidative stress in Alzheimer’s disease. PLoS ONE 7(1), e29789 (2012)CrossRef
6.
go back to reference A.P. Dhawan, W.J. Heetderks, M. Pavel, S. Acharya, M. Akay, A. Mairal, B. Wheeler, C.C. Dacso, T. Sunder, N. Lovell, M. Gerber, M. Shah, S.G. Senthilvel, M.D. Wang, B. Bhargava, Current and future challenges in point-of-care technologies: a paradigm-shift in affordable global healthcare with personalized and preventive medicine. Transl. Eng. Health Med., IEEE J. 3, 1–10 (2015)CrossRef A.P. Dhawan, W.J. Heetderks, M. Pavel, S. Acharya, M. Akay, A. Mairal, B. Wheeler, C.C. Dacso, T. Sunder, N. Lovell, M. Gerber, M. Shah, S.G. Senthilvel, M.D. Wang, B. Bhargava, Current and future challenges in point-of-care technologies: a paradigm-shift in affordable global healthcare with personalized and preventive medicine. Transl. Eng. Health Med., IEEE J. 3, 1–10 (2015)CrossRef
7.
go back to reference D. Polese, A. Convertino, L. Maiolo, A. Ferrone, L. Pazzini, M. Marrani, F. Maita, A. Pecora, G. Fortunato, G. Fiaschi, Investigation on nanostructured biosensor for Biotin detection. Sensors, 2014 IEEE, pp. 1627–1630, 2014 D. Polese, A. Convertino, L. Maiolo, A. Ferrone, L. Pazzini, M. Marrani, F. Maita, A. Pecora, G. Fortunato, G. Fiaschi, Investigation on nanostructured biosensor for Biotin detection. Sensors, 2014 IEEE, pp. 1627–1630, 2014
8.
go back to reference S. Feng, L.E. Roseng, T. Dong, Quantitative detection of Escherichia coli and measurement of urinary tract infection diagnosis possibility by use of a portable, handheld sensor. Medical Measurements and Applications (MeMeA), 2015 IEEE International Symposium on, pp. 586–589, 2015 S. Feng, L.E. Roseng, T. Dong, Quantitative detection of Escherichia coli and measurement of urinary tract infection diagnosis possibility by use of a portable, handheld sensor. Medical Measurements and Applications (MeMeA), 2015 IEEE International Symposium on, pp. 586–589, 2015
9.
go back to reference M.M.S. Silva, a.C.M.S. Dias, M.T. Cordeiro, E. Marques, M.O.F. Goulart, R.F. Dutra, A thiophene-modified screen printed electrode for detection of dengue virus NS1 protein. Talanta 128, 505–510 (2014) M.M.S. Silva, a.C.M.S. Dias, M.T. Cordeiro, E. Marques, M.O.F. Goulart, R.F. Dutra, A thiophene-modified screen printed electrode for detection of dengue virus NS1 protein. Talanta 128, 505–510 (2014)
10.
go back to reference R. Elshafey, A.C. Tavares, M. Siaj, M. Zourob, Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue. Biosens. Bioelectron. 50, 143–149 (2013)CrossRef R. Elshafey, A.C. Tavares, M. Siaj, M. Zourob, Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue. Biosens. Bioelectron. 50, 143–149 (2013)CrossRef
11.
go back to reference Y.H. Yun, B.K. Lee, J.S. Choi, S. Kim, B. Yoo, Y.S. Kim, K. Park, Y.W. Cho, A glucose sensor fabricated by piezoelectric inkjet printing of conducting polymers and bienzymes. Anal. Sci. 27(4), 375 (2011)CrossRef Y.H. Yun, B.K. Lee, J.S. Choi, S. Kim, B. Yoo, Y.S. Kim, K. Park, Y.W. Cho, A glucose sensor fabricated by piezoelectric inkjet printing of conducting polymers and bienzymes. Anal. Sci. 27(4), 375 (2011)CrossRef
12.
go back to reference A.M. Pernia, M.J. Prieto, I.C. Orille, J.A. Martin-Ramos, A. Costa-Garcia, Development of Optimized Screen-Printed Immunosensors. Instrum. Measur., IEEE Trans. 58(7), 2181–2188 (2009) A.M. Pernia, M.J. Prieto, I.C. Orille, J.A. Martin-Ramos, A. Costa-Garcia, Development of Optimized Screen-Printed Immunosensors. Instrum. Measur., IEEE Trans. 58(7), 2181–2188 (2009)
13.
go back to reference R.A.S. Couto, J.L.F.C. Lima, M.B. Quinaz, Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis. Talanta 146, 801–814 (2016)CrossRef R.A.S. Couto, J.L.F.C. Lima, M.B. Quinaz, Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis. Talanta 146, 801–814 (2016)CrossRef
14.
go back to reference V. Escamilla-Gómez, D. Hernández-Santos, M.B. González-García, J.M. Pingarrón-Carrazón, A. Costa-García, Simultaneous detection of free and total prostate specific antigen on a screen-printed electrochemical dual sensor. Biosens. Bioelectron. 24, 2678–2683 (2009)CrossRef V. Escamilla-Gómez, D. Hernández-Santos, M.B. González-García, J.M. Pingarrón-Carrazón, A. Costa-García, Simultaneous detection of free and total prostate specific antigen on a screen-printed electrochemical dual sensor. Biosens. Bioelectron. 24, 2678–2683 (2009)CrossRef
15.
go back to reference Y.-F. Liang, C.-Y. Huang, B.-D. Liu, A voltammetry potentiostat design for large dynamic range current measurement. Intelligent Computation and Bio-Medical Instrumentation (ICBMI), 2011 International Conference on, pp. 260–263, 2011 Y.-F. Liang, C.-Y. Huang, B.-D. Liu, A voltammetry potentiostat design for large dynamic range current measurement. Intelligent Computation and Bio-Medical Instrumentation (ICBMI), 2011 International Conference on, pp. 260–263, 2011
16.
go back to reference G. Martínez-Paredes, M.B. González-García, A. Costa-García, Genosensor for detection of four pneumoniae bacteria using gold nanostructured screen-printed carbon electrodes as transducers. Sens. Actuators, B Chem. 149, 329–335 (2010)CrossRef G. Martínez-Paredes, M.B. González-García, A. Costa-García, Genosensor for detection of four pneumoniae bacteria using gold nanostructured screen-printed carbon electrodes as transducers. Sens. Actuators, B Chem. 149, 329–335 (2010)CrossRef
17.
go back to reference P. Kara, A. de la Escosura-Muñiz, M. Maltez-da Costa, M. Guix, M. Ozsoz, A. Merkoçi, Aptamers based electrochemical biosensor for protein detection using carbon nanotubes platforms. Biosens. Bioelectron. 26, 1715–1718 (2010) P. Kara, A. de la Escosura-Muñiz, M. Maltez-da Costa, M. Guix, M. Ozsoz, A. Merkoçi, Aptamers based electrochemical biosensor for protein detection using carbon nanotubes platforms. Biosens. Bioelectron. 26, 1715–1718 (2010)
18.
go back to reference B. Jeong, R. Akter, O.H. Han, C.K. Rhee, Increased electrocatalyzed performance through dendrimer–encapsulated gold nanoparticles and carbon nanotube–assisted multiple bienzymatic labels: highly sensitive electrochemical immunosensor for protein detection. Anal. Chem. 85(3), 1784–1791 (2013) B. Jeong, R. Akter, O.H. Han, C.K. Rhee, Increased electrocatalyzed performance through dendrimer–encapsulated gold nanoparticles and carbon nanotube–assisted multiple bienzymatic labels: highly sensitive electrochemical immunosensor for protein detection. Anal. Chem. 85(3), 1784–1791 (2013)
Metadata
Title
Preliminary Study of a Low-Cost Point-of-Care Testing System Using Screen-Printed Biosensors for Early Biomarkers Detection Related to Alzheimer Disease
Authors
Sarah Tonello
Mauro Serpelloni
Nicola Francesco Lopomo
Giulia Abate
Daniela Letizia Uberti
Emilio Sardini
Copyright Year
2018
DOI
https://doi.org/10.1007/978-3-319-55077-0_32