Skip to main content
Top

2017 | OriginalPaper | Chapter

Progressive Motion Artifact Removal in PPG Signal for Accurate Heart Rate Estimation

Authors : Ji Hun An, Heemang Song, Hyun-Chool Shin

Published in: Advanced Multimedia and Ubiquitous Engineering

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper proposes a motion artifact (MA) removal method in the photoplethysmographic (PPG) signal for accurate heart rate estimation. PPG signal is easy to acquire, but it is easily distorted by body movement. In this study, MA is analyzed using acceleration signals and removed in the PPG spectrum for accurate heart rate estimation. The proposed method progressively removes three-axis acceleration spectra in order of spectral power. The performance was confirmed by comparing heart rate estimation errors one case that MA was removed with another case that MA was not removed. After removing MA and applying two peak tracking methods in 12 data sets, the mean absolute error (MAE) of the beat per minute (BPM) is lower than conventional methods.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Allen, J.: Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28(3), R1–R39 (2007)CrossRef Allen, J.: Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28(3), R1–R39 (2007)CrossRef
2.
go back to reference Zhang, Z., Pi, Z., Liu, B.: TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Trans. Biomed. Eng. 62(2), 522–531 (2015)CrossRef Zhang, Z., Pi, Z., Liu, B.: TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Trans. Biomed. Eng. 62(2), 522–531 (2015)CrossRef
3.
go back to reference Kim, B.S., Yoo, S.K.: Motion artifact reduction in photoplethysmography using independent component analysis. IEEE Trans. Biomed. Eng. 53(3), 566–568 (2006)MathSciNetCrossRef Kim, B.S., Yoo, S.K.: Motion artifact reduction in photoplethysmography using independent component analysis. IEEE Trans. Biomed. Eng. 53(3), 566–568 (2006)MathSciNetCrossRef
4.
go back to reference Lee, B., Han, J., Baek, H.J., Shin, J.H., Park, K.S., Yi, W.J.: Improved elimination of motion artifacts from a photoplehysmographic signal using a Kalman smoother with simultaneous accelerometry. Physiol. Meas. 31(12), 1585–1603 (2010)CrossRef Lee, B., Han, J., Baek, H.J., Shin, J.H., Park, K.S., Yi, W.J.: Improved elimination of motion artifacts from a photoplehysmographic signal using a Kalman smoother with simultaneous accelerometry. Physiol. Meas. 31(12), 1585–1603 (2010)CrossRef
5.
go back to reference Krishnan, R., Natarajan, B., Warren, S.: Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans. Biomed. Eng. 57(8), 1867–1876 (2010)CrossRef Krishnan, R., Natarajan, B., Warren, S.: Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans. Biomed. Eng. 57(8), 1867–1876 (2010)CrossRef
6.
go back to reference López, S.M., Giannetti, R., Dotor, M.L., Silveria, J.P., Golmayo, D., Miguel-Tobal, F., Bilbao, A., Galindo Canales, M., Martn Escudero, P., et al.: Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test. J. Med. Biol. Eng. 32(3), 181–188 (2012)CrossRef López, S.M., Giannetti, R., Dotor, M.L., Silveria, J.P., Golmayo, D., Miguel-Tobal, F., Bilbao, A., Galindo Canales, M., Martn Escudero, P., et al.: Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test. J. Med. Biol. Eng. 32(3), 181–188 (2012)CrossRef
7.
go back to reference Sun, B., Zhang, Z.: Photoplethysmography-based heart rate monitoring using asymmetric least squares spectrum subtraction and Bayesian decision theory. IEEE Sens. J. 15(12), 7161–7168 (2015)CrossRef Sun, B., Zhang, Z.: Photoplethysmography-based heart rate monitoring using asymmetric least squares spectrum subtraction and Bayesian decision theory. IEEE Sens. J. 15(12), 7161–7168 (2015)CrossRef
8.
go back to reference Ram, M., Madhav, K.V., Krishna, E.H., Komalla, N.R., Reddy, K.A.: A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive Iter. IEEE Trans. Instrum. Meas. 61(5), 1445–1457 (2012)CrossRef Ram, M., Madhav, K.V., Krishna, E.H., Komalla, N.R., Reddy, K.A.: A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive Iter. IEEE Trans. Instrum. Meas. 61(5), 1445–1457 (2012)CrossRef
9.
go back to reference Yousefi, R., Nourani, M., Ostadabbas, S., Panahi, I.: A motion-tolerant adaptive algorithm for wearable photoplethysmographic biosensors. IEEE J. Biomed. Health Inform. 18(2), 670–681 (2014)CrossRef Yousefi, R., Nourani, M., Ostadabbas, S., Panahi, I.: A motion-tolerant adaptive algorithm for wearable photoplethysmographic biosensors. IEEE J. Biomed. Health Inform. 18(2), 670–681 (2014)CrossRef
10.
go back to reference Reddy, K.A., George, B., Kumar, V.J.: Use of fourier series analysis for motion artifact reduction and data compression of photoplethysmographic signals. IEEE Trans. Instrum. Meas. 58(5), 1706–1711 (2009)CrossRef Reddy, K.A., George, B., Kumar, V.J.: Use of fourier series analysis for motion artifact reduction and data compression of photoplethysmographic signals. IEEE Trans. Instrum. Meas. 58(5), 1706–1711 (2009)CrossRef
11.
go back to reference Zhang, Z.: Undergraduate students compete in the IEEE signal processing cup: part 3. IEEE Signal Process. Mag. 32(6), 13–116 (2015)CrossRef Zhang, Z.: Undergraduate students compete in the IEEE signal processing cup: part 3. IEEE Signal Process. Mag. 32(6), 13–116 (2015)CrossRef
Metadata
Title
Progressive Motion Artifact Removal in PPG Signal for Accurate Heart Rate Estimation
Authors
Ji Hun An
Heemang Song
Hyun-Chool Shin
Copyright Year
2017
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-5041-1_92

Premium Partner