Skip to main content
Top
Published in:
Cover of the book

2020 | OriginalPaper | Chapter

1. Quasi-Passive Lower and Upper Extremity Robotic Exoskeleton for Strengthening Human Locomotion

Authors : Aryaman Arora, John R. McIntyre

Published in: Sustainable Innovation

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Most of the robotic exoskeletons available today are either lower extremity or upper extremity devices targeting individual orthotic (elbow, knee, and ankle) joints. However, there are a few which target both lower and upper extremities. This chapter aims to propose a design for a wearable quasi-passive lower and upper extremity robotic exoskeleton (QLUE-REX) system, targeting disabled users and aged seniors. This exoskeleton system aims to improve mobility, assist walking, improve and enhance muscle strength, and help people with leg/arm disabilities. QLUE-REX combines elbow, knee, and ankle joints with options to synchronize individual joints’ movements to achieve the following: (1) assist in lifting loads of 30–40 kilograms, (2) assist in walking, (3) easy and flexible to wear without any discomfort, and (4) be able to learn and adapt along with storing time-stamped sensor data on its exoskeleton storage media for predicting/correcting users’ movements and share data with health professionals. The research’s main objective is to conceptualize a design for QLUE-REX system. QLUE-REX will be a feasible modular-type wearable system that incorporates orthotic elbow, knee, and ankle joints effectively in either synchronous or asynchronous modes depending on the users’ needs. It will utilize human-walking analysis, data sensing and estimation technology, and measurement of the electromyography signals of user’s muscles, exploiting biomechanical principles of human-machine interface.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
go back to reference Almekkawy, M., Chen, J., Ellis, M., Haemmerich, D., Holmes, D., Linte, C., … Zderic, V. (2019). Therapeutic systems and technologies: State-of-the-art, applications, opportunities and challenges. IEEE Reviews in Biomedical Engineering. Almekkawy, M., Chen, J., Ellis, M., Haemmerich, D., Holmes, D., Linte, C., … Zderic, V. (2019). Therapeutic systems and technologies: State-of-the-art, applications, opportunities and challenges. IEEE Reviews in Biomedical Engineering.
go back to reference Arnold, C. M., & Faulkner, R. A. (2002). The history of falls and the association of the timed up and go test to falls and near-falls in older adults with hip osteoarthritis. Journal of the American Geriatrics Society, 50, 671–678.CrossRef Arnold, C. M., & Faulkner, R. A. (2002). The history of falls and the association of the timed up and go test to falls and near-falls in older adults with hip osteoarthritis. Journal of the American Geriatrics Society, 50, 671–678.CrossRef
go back to reference Bacsu, J. R., Jeffery, B., Johnson, S., Martz, D., Novik, N., & Abonyi, S. (2012). Healthy aging in place: Supporting rural seniors’ health needs. Online Journal of Rural Nursing and Health Care, 12(2), 77–87. Bacsu, J. R., Jeffery, B., Johnson, S., Martz, D., Novik, N., & Abonyi, S. (2012). Healthy aging in place: Supporting rural seniors’ health needs. Online Journal of Rural Nursing and Health Care, 12(2), 77–87.
go back to reference Chu, A., Kazerooni, H., & Zoss, A. (2005). On the biomimetic design of the Berkeley lower extremity exoskeleton (BLEEX). Proceedings of Robotics and Automation, ICRA 2005, Proceedings of the 2005 IEEE International Conference on Intelligent Robots and Systems (pp. 4345–4352). https://doi.org/10.1109/ROBOT.2005.1570789 Chu, A., Kazerooni, H., & Zoss, A. (2005). On the biomimetic design of the Berkeley lower extremity exoskeleton (BLEEX). Proceedings of Robotics and Automation, ICRA 2005, Proceedings of the 2005 IEEE International Conference on Intelligent Robots and Systems (pp. 4345–4352). https://​doi.​org/​10.​1109/​ROBOT.​2005.​1570789
go back to reference Cozen, J. A. (1999). Robotic assistance of an active upper limb exercise in neurologically impaired patients. IEEE Transactions on Rehabilitation Engineering, 7(2), 254–256.CrossRef Cozen, J. A. (1999). Robotic assistance of an active upper limb exercise in neurologically impaired patients. IEEE Transactions on Rehabilitation Engineering, 7(2), 254–256.CrossRef
go back to reference Ferguson, P. W., Dimapasoc, B., Shen, Y., & Rosen, J. (2018, October). Design of a hand exoskeleton for use with upper limb exoskeletons. InInternational symposium on wearable robotics (pp. 276–280). Cham: Springer. Ferguson, P. W., Dimapasoc, B., Shen, Y., & Rosen, J. (2018, October). Design of a hand exoskeleton for use with upper limb exoskeletons. InInternational symposium on wearable robotics (pp. 276–280). Cham: Springer.
go back to reference Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003). Upper and lower extremity robotic devices for rehabilitation and for studying motor control. Current Opinion in Neurology, 16(6), 705–710.CrossRef Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003). Upper and lower extremity robotic devices for rehabilitation and for studying motor control. Current Opinion in Neurology, 16(6), 705–710.CrossRef
go back to reference Iezzoni, L. I. (2003). When walking fails. Berkeley, CA: University of California Press. Iezzoni, L. I. (2003). When walking fails. Berkeley, CA: University of California Press.
go back to reference Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013, July). High accuracy decoding of user intentions using EEG to control a lower-body exoskeleton. In 2013 35th annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 5606–5609). IEEE. Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013, July). High accuracy decoding of user intentions using EEG to control a lower-body exoskeleton. In 2013 35th annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 5606–5609). IEEE.
go back to reference Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016). Enhancing nervous system recovery through neurobiologics, neural interface training, and neurorehabilitation. Frontiers in Neuroscience, 10, 584.CrossRef Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016). Enhancing nervous system recovery through neurobiologics, neural interface training, and neurorehabilitation. Frontiers in Neuroscience, 10, 584.CrossRef
go back to reference Leveille, S. G., Bean, J., Bandeen-Roche, K., Jones, R., Hochberg, M., & Guralnik, J. M. (2002). Musculoskeletal pain and risk for falls in older disabled women living in the community. Journal of the American Geriatrics Society, 50(4), 671–678.CrossRef Leveille, S. G., Bean, J., Bandeen-Roche, K., Jones, R., Hochberg, M., & Guralnik, J. M. (2002). Musculoskeletal pain and risk for falls in older disabled women living in the community. Journal of the American Geriatrics Society, 50(4), 671–678.CrossRef
go back to reference Lewis, C. L., & Ferris, D. P. (2011). Invariant hip moment patterns when walking with a robotic hip exoskeleton. Journal of Biomechanics, 44(5), 789–793.CrossRef Lewis, C. L., & Ferris, D. P. (2011). Invariant hip moment patterns when walking with a robotic hip exoskeleton. Journal of Biomechanics, 44(5), 789–793.CrossRef
go back to reference Li, G., Fang, Q., Xu, T., Zhao, J., Cai, H., & Zhu, Y. (2019). Inverse kinematic analysis and trajectory planning of a modular upper limb rehabilitation exoskeleton. Technology and Health Care, (Preprint), 1–10. Li, G., Fang, Q., Xu, T., Zhao, J., Cai, H., & Zhu, Y. (2019). Inverse kinematic analysis and trajectory planning of a modular upper limb rehabilitation exoskeleton. Technology and Health Care, (Preprint), 1–10.
go back to reference Lum, P. S., Burgar, C. G., Van der Loos, M., Shor, P., Majmundar, M., & Yap, R. (2005). The MIME robotic system for upper-limb neuro-rehabilitation: Results from a clinical trial in subacute stroke. In Proceedings from ICCOR 9th International Conference on Rehabilitation Robotics, 2005 (pp. 511–514). Chicago, IL: IEEE. https://doi.org/10.1109/ICORR.2005.1501153 Lum, P. S., Burgar, C. G., Van der Loos, M., Shor, P., Majmundar, M., & Yap, R. (2005). The MIME robotic system for upper-limb neuro-rehabilitation: Results from a clinical trial in subacute stroke. In Proceedings from ICCOR 9th International Conference on Rehabilitation Robotics, 2005 (pp. 511–514). Chicago, IL: IEEE. https://​doi.​org/​10.​1109/​ICORR.​2005.​1501153
go back to reference Morone, G., Paolucci, S., Cherubini, A., De Angelis, D., Venturiero, V., Coiro, P., & Iosa, M. (2017). Robot-assisted gait training for stroke patients: Current state of the art and perspectives of robotics. Neuropsychiatric Disease and Treatment, 13, 1303.CrossRef Morone, G., Paolucci, S., Cherubini, A., De Angelis, D., Venturiero, V., Coiro, P., & Iosa, M. (2017). Robot-assisted gait training for stroke patients: Current state of the art and perspectives of robotics. Neuropsychiatric Disease and Treatment, 13, 1303.CrossRef
go back to reference Nef, T., Guidali, M., & Riener, R. (2009). ARMin III–arm therapy exoskeleton with an ergonomic shoulder actuation. Applied Bionics and Biomechanics, 6(2), 127–142.CrossRef Nef, T., Guidali, M., & Riener, R. (2009). ARMin III–arm therapy exoskeleton with an ergonomic shoulder actuation. Applied Bionics and Biomechanics, 6(2), 127–142.CrossRef
go back to reference Rupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., & Virk, G. S. (2017). Lower-limb exoskeletons: Research trends and regulatory guidelines in medical and non-medical applications. International Journal of Advanced Robotic Systems, 14(6). http://dx.doi.org/10.1729881417743554 Rupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., & Virk, G. S. (2017). Lower-limb exoskeletons: Research trends and regulatory guidelines in medical and non-medical applications. International Journal of Advanced Robotic Systems, 14(6). http://​dx.​doi.​org/​10.​1729881417743554​
go back to reference Sanchez, R. J., Wolbrecht, E., Smith, R., Liu, J., Rao, S., Cramer, S., … & Reinkensmeyer, D. J. (2005, June). A pneumatic robot for re-training arm movement after stroke: Rationale and mechanical design. In 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005 (pp. 500–504). IEEE. Sanchez, R. J., Wolbrecht, E., Smith, R., Liu, J., Rao, S., Cramer, S., … & Reinkensmeyer, D. J. (2005, June). A pneumatic robot for re-training arm movement after stroke: Rationale and mechanical design. In 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005 (pp. 500–504). IEEE.
go back to reference Shen, Y., Ma, J., Dobkin, B., & Rosen, J. (2018, July). Asymmetric dual arm approach for post stroke recovery of motor functions utilizing the EXO-UL8 exoskeleton system: A pilot study. In 2018 40th annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 1701–1707). IEEE. Shen, Y., Ma, J., Dobkin, B., & Rosen, J. (2018, July). Asymmetric dual arm approach for post stroke recovery of motor functions utilizing the EXO-UL8 exoskeleton system: A pilot study. In 2018 40th annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 1701–1707). IEEE.
go back to reference Silveira, A. T., Souza, M. A. D., Fernandes, B. L., & Nohama, P. (2018). From the past to the future of therapeutic orthoses for upper limbs rehabilitation. Research on Biomedical Engineering, 34(4), 368–380.CrossRef Silveira, A. T., Souza, M. A. D., Fernandes, B. L., & Nohama, P. (2018). From the past to the future of therapeutic orthoses for upper limbs rehabilitation. Research on Biomedical Engineering, 34(4), 368–380.CrossRef
go back to reference Singh, H., Unger, J., Zariffa, J., Pakosh, M., Jaglal, S., Craven, B. C., & Musselman, K. E. (2018). Robot-assisted upper extremity rehabilitation for cervical spinal cord injuries: A systematic scoping review. Disability and Rehabilitation: Assistive Technology, 13(7), 704–715. Singh, H., Unger, J., Zariffa, J., Pakosh, M., Jaglal, S., Craven, B. C., & Musselman, K. E. (2018). Robot-assisted upper extremity rehabilitation for cervical spinal cord injuries: A systematic scoping review. Disability and Rehabilitation: Assistive Technology, 13(7), 704–715.
go back to reference Stokes, J., & Lindsay, J. (1996). Major causes of death and hospitalization in Canadian seniors. Chronic Disease in Canada, 17, 63–73. Stokes, J., & Lindsay, J. (1996). Major causes of death and hospitalization in Canadian seniors. Chronic Disease in Canada, 17, 63–73.
go back to reference Yu, S. N., Lee, H. D., Lee, S. H., Kim, W. S., Han, J. S., & Han, C. S. (2012). Design of an under-actuated exoskeleton system for walking assist while load carrying. Advanced Robotics, 26(5–6), 561–580.CrossRef Yu, S. N., Lee, H. D., Lee, S. H., Kim, W. S., Han, J. S., & Han, C. S. (2012). Design of an under-actuated exoskeleton system for walking assist while load carrying. Advanced Robotics, 26(5–6), 561–580.CrossRef
go back to reference Zoss, A., Kazerooni, H., & Chu, A. (2005). On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX). In Proceedings from Intelligent Robots and Systems, 2005. (IROS 2005). 2005 IEEE/RSJ International Conference on (pp. 3465–3472). Edmonton, AB: IEEE. https://doi.org/10.1109/IROS.2005.1545453 Zoss, A., Kazerooni, H., & Chu, A. (2005). On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX). In Proceedings from Intelligent Robots and Systems, 2005. (IROS 2005). 2005 IEEE/RSJ International Conference on (pp. 3465–3472). Edmonton, AB: IEEE. https://​doi.​org/​10.​1109/​IROS.​2005.​1545453
go back to reference Zaroug, A., Proud, J. K., Lai, D. T., Mudie, K., Billing, D., & Begg, R. (2019). Overview of Computational Intelligence (CI) techniques for powered exoskeletons. In Computational intelligence in sensor networks (pp. 353–383). Berlin, Heidelberg: Springer.CrossRef Zaroug, A., Proud, J. K., Lai, D. T., Mudie, K., Billing, D., & Begg, R. (2019). Overview of Computational Intelligence (CI) techniques for powered exoskeletons. In Computational intelligence in sensor networks (pp. 353–383). Berlin, Heidelberg: Springer.CrossRef
Metadata
Title
Quasi-Passive Lower and Upper Extremity Robotic Exoskeleton for Strengthening Human Locomotion
Authors
Aryaman Arora
John R. McIntyre
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-30421-8_1