Abstract

Background: Physicians use diver radiology technologies on a daily basis to diagnose stage and treat cancers with the goal of saving thousands of lives. The use of CT scans in medical diagnosis exposes patients to radiation doses higher than other radiological procedures. It is estimated that CT scans represent about 20% of radiological procedures and contribute about 80% to medical radiological exposure doses. Purpose: The purpose of this study is to estimate the doses delivered during abdominopelvic CT procedures in order to evaluate the biological effects in patients at the Mohamed VI University Health Centre in Oujda, Morocco.
Materials and methods: A GENERAL ELECTRIC (GE) Optima CT 540 scanner is used for all CT examinations. A study of 30 patients was carried out in the emergency radiology department. Data were collected from abdominopelvic examinations. For each scan, CT acquisition parameters, including the number of series, contrast medium usage, kV tube, tube current and rotation time, slice thickness, CT dose index (CTDIvol) displayed and Dose Length (DLP) product. The effective dose and the biological effects were estimated using the conversion factors of the International Commission on Radiological Protection (ICRP).
Results: The tube voltage (kV), tube current and rotation time were 120 (kV), 275 (mA) and 1.75 (s) respectively. The average CT dose index (CTDIvol) displayed was (8.37 ± 2.52) mGy. The average dose length (DLP) product was (352.41 ± 153.53) mGy.cm, with a third quartile of 416.5 mGy.cm. The average effective dose received by the patient during an abdominopelvic CT was (5.36 ± 2.33) mSv, with a third quartile of 6.33 mSv. The risk of cancer per abdominopelvic CT procedure is in the order of 348 per one million procedures while the hereditary risk per procedure is about 13 per one million procedures. The effective dose and risk factors for abdominopelvic CT are well below several values recorded on an international scale.
Conclusion: Cancer and hereditary risks are increased when performing multiple scan acquisitions. The study found that the doses received during abdominopelvic CT procedures at Mohammed VI University Hospital in Oujda were within an acceptable range. However, staff must optimize the radiation dose during abdominopelvic procedures, and a CT dose optimization protocol must be implemented in the Moroccan hospitals.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Suetens, P.: Fundamentals of Medical Imaging. Cambridge University Press, Cambridge (2017)CrossRef Suetens, P.: Fundamentals of Medical Imaging. Cambridge University Press, Cambridge (2017)CrossRef
2.
go back to reference Tortora, G.J., Derrickson, B.: Principles of Anatomy & Physiology. Wiley, Hoboken (2017) Tortora, G.J., Derrickson, B.: Principles of Anatomy & Physiology. Wiley, Hoboken (2017)
3.
go back to reference Weissleder, R.: Molecular imaging in cancer. Science 312(5777), 1168–1171 (2006)CrossRef Weissleder, R.: Molecular imaging in cancer. Science 312(5777), 1168–1171 (2006)CrossRef
4.
go back to reference Stone, S.: Communicating with patients undergoing abdominopelvic CT imaging, pp. 76–77 (2018) Stone, S.: Communicating with patients undergoing abdominopelvic CT imaging, pp. 76–77 (2018)
5.
go back to reference Giannitto, C., et al.: Unindicated multiphase CT scans in non-traumatic abdominal emergencies for women of reproductive age: a significant source of unnecessary exposure. Radiol. Med. (Torino) 123(3), 185–190 (2018)CrossRef Giannitto, C., et al.: Unindicated multiphase CT scans in non-traumatic abdominal emergencies for women of reproductive age: a significant source of unnecessary exposure. Radiol. Med. (Torino) 123(3), 185–190 (2018)CrossRef
8.
go back to reference Allisy-Roberts, P., Williams, J.: Farr’s Physics for Medical Imaging. Elsevier, Amsterdam (2007). ISBN 9780702028441 Allisy-Roberts, P., Williams, J.: Farr’s Physics for Medical Imaging. Elsevier, Amsterdam (2007). ISBN 9780702028441
9.
go back to reference Dendy, P.P., Heaton, B.: Physics for Diagnostic Radiology. Taylor & Francis, New York (1999). ISBN 9780750305914CrossRef Dendy, P.P., Heaton, B.: Physics for Diagnostic Radiology. Taylor & Francis, New York (1999). ISBN 9780750305914CrossRef
10.
go back to reference Kamiya, K., Ozasa, K., Akiba, S., et al.: Long-term effects of radiation exposure on health. Lancet 386(9992), 469–478 (2015)CrossRef Kamiya, K., Ozasa, K., Akiba, S., et al.: Long-term effects of radiation exposure on health. Lancet 386(9992), 469–478 (2015)CrossRef
11.
go back to reference Ma, S., Kong, B., Liu, B., Liu, X.: Biological effects of low-dose radiation from computed tomography scanning. Int. J. Radiat. Biol. 89(5), 326–333 (2013)CrossRef Ma, S., Kong, B., Liu, B., Liu, X.: Biological effects of low-dose radiation from computed tomography scanning. Int. J. Radiat. Biol. 89(5), 326–333 (2013)CrossRef
12.
go back to reference Elgazzar, A.H., Kazem, N.: Biological effects of ionizing radiation. In: Elgazzar, A.H. (ed.) The Pathophysiologic Basis of Nuclear Medicine. Springer, Heidelberg (2006)CrossRef Elgazzar, A.H., Kazem, N.: Biological effects of ionizing radiation. In: Elgazzar, A.H. (ed.) The Pathophysiologic Basis of Nuclear Medicine. Springer, Heidelberg (2006)CrossRef
13.
go back to reference Harrison, J.D., et al.: Use of effective dose. Ann. ICRP 45(1_suppl), 215–2016 (2016)CrossRef Harrison, J.D., et al.: Use of effective dose. Ann. ICRP 45(1_suppl), 215–2016 (2016)CrossRef
15.
go back to reference Semghouli, S., Amaoui, B., El Kharras, A., Bouyakhlef, K., Hakam, O.K., Choukri, A.: Establishment of a diagnostic reference level for brain CT procedures in Moroccan Hospitals. Int. J. Adv. Res. 5(5), 319–324 (2017)CrossRef Semghouli, S., Amaoui, B., El Kharras, A., Bouyakhlef, K., Hakam, O.K., Choukri, A.: Establishment of a diagnostic reference level for brain CT procedures in Moroccan Hospitals. Int. J. Adv. Res. 5(5), 319–324 (2017)CrossRef
18.
go back to reference ICRP 2007: The 2007 recommendations of the international commission on radiological protection. ICRP publication 103. Ann. ICRP 37(2–4), 1–332 (2007) ICRP 2007: The 2007 recommendations of the international commission on radiological protection. ICRP publication 103. Ann. ICRP 37(2–4), 1–332 (2007)
19.
21.
go back to reference Canadian Computed tomography survey. National diagnostic reference levels. Health Canada (2016) Canadian Computed tomography survey. National diagnostic reference levels. Health Canada (2016)
24.
go back to reference Roch, P., Aubert, B.: French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004–2008 review. Radiat. Prot. Dosimetry. 154(1), 52–75 (2013)CrossRef Roch, P., Aubert, B.: French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004–2008 review. Radiat. Prot. Dosimetry. 154(1), 52–75 (2013)CrossRef
25.
go back to reference Salama, D.H., Vassileva, J., Mahdaly, G., Shawki, M., Salama, A., Gilley, D., Rehani, M.M.: Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt. Phys. Med. 39, 16–24 (2017)CrossRef Salama, D.H., Vassileva, J., Mahdaly, G., Shawki, M., Salama, A., Gilley, D., Rehani, M.M.: Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt. Phys. Med. 39, 16–24 (2017)CrossRef
Metadata
Title
Risks of Radiation Exposure During Abdominopelvic CT Procedures at Mohamed VI University Hospital of Oujda, Morocco
Authors
Mohammed Aabid
Slimane Semghouli
Oum Keltoum Hakam
Abdelmajid Choukri
Copyright Year
2020
DOI
https://doi.org/10.1007/978-3-030-37629-1_26

Premium Partner