Open Access 01-12-2022 | Original Article

Simplified Matrix Focusing Imaging Algorithm for Ultrasonic Nondestructive Testing

Authors: Xinyu Zhao, Zemin Ma, Jiaying Zhang

Published in: Chinese Journal of Mechanical Engineering | Issue 1/2022

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT. However, it is still suffering from the time-consuming data acquisition and processing. In order to solve the problem, two simplified matrix focusing methods are provided in the paper. One provided method is a triangular matrix focusing algorithm based on the principle of reciprocity for the multi-channel ultrasonic system. The other provided method is a trapezoidal matrix focusing algorithm based on the energy weight of the different channel to the focusing area. Time of data acquisition and computational is decreased with the provided simplified matrix focusing methods. In order to prove the validity of two provided algorithms, both side-drilled holes and oblique cracks are used for imaging experiments. The experimental results show that the imaging quality of the triangular matrix focusing algorithm is basically consistent to that of the full matrix focusing method. And imaging quality of the trapezoidal matrix focusing algorithm is slightly reduced with the amount of multi-channel data decreasing. Both data acquisition and computational efficiency using the triangular matrix focusing algorithm and the trapezoidal matrix focusing algorithm have been improved significantly compared with original full matrix focusing method.

1 Introduction

In recent years, ultrasonic phased array technology has been developed rapidly [14]. And ultrasonic phased array technology has been gradually applied in the field of industrial nondestructive testing [58]. The phased array imaging algorithms have been widely studied [912]. Holmes et al. [13] proposed the concept of full-matrix focus capture (FMC), and set up the total focus method (TFM) algorithm using FMC. Compared with the conventional ultrasonic phased array testing, the geometric features of defects are more clearly with TFM technology. And the image quality of TFM technology is significantly better than the traditional phased array imaging algorithm with steering and focusing time delays. Wu et al. [14] extended the total focusing imaging method to the multi-mode case with both direct and reflection waves. Pan et al. [15] used the total focusing imaging method to simulate the cracks quantitatively. Wu et al. [16] studied primary reflection detection mode based on the optimized direct wave detection, and provided the multi-mode composite full focus imaging method. Aiming at the problem of internal defect detection of aluminum container weld, Wang et al. [17] proposed an ultrasonic array full focus imaging method based on oblique incidence.
However, TFM imaging is a time-consuming method due to the large amount of full matrix data [1821], and it is difficult to obtain real-time image [2225]. In order to improve the efficiency of TFM, Ran [26] used FPGA to analyzing the principle of full focus synthetic aperture imaging algorithm, and designed software to optimize the algorithm for results. Jin et al. [27] introduced the wavenumber algorithm to improving computational efficiency for ultrasonic full-matrix imaging in multi- layered medium. Post-processing speed of full matrix data is increased significantly with the provided method. The binary particle swarm optimization (BPSO) algorithm is applied to optimize the array layout. The BPSO algorithm produced favorable results in the case of small-scale sparse array [28]. Hu et al. [29, 30] optimized the locations of active array elements in the sparse array with the genetic algorithm.
Two simplified matrix focusing methods are proposed in the paper. One is the triangular matrix focusing algorithm based on the reciprocity principle of the transmitter and receiver channel, named as triangular matrix focusing method. The other one is the trapezoidal matrix focusing algorithm based on the energy weight of the distance from different channels to the focusing point, named as trapezoidal matrix focusing method.
In Section 2, the data acquisition and imaging algorithm of full matrix focusing method is introduced, and the simplified imaging methods are provided. In Section 3, side-drilled holes and oblique crack defects imaging experiments are carried out. The experimental results are analyzed to compare the imaging quality and computational efficiency with three image algorithms.

2 Focus Imaging Algorithm

2.1 Full Matrix Focused Data Acquisition

A-scan data is acquired and arranged in a matrix for imaging. Taking a linear array with n elements as an example, the 1st element is fired and all elements are received. The acquired data is named as A11, A12, ..., A1n. And the acquired data is placed in the first row. Then next element is excited in turn until all the n×n A-scan data are acquired as listed in Eq. (1).
$$ \left[ {\begin{array}{*{20}c} {A_{11} } & {A_{12} } & {A_{13} } & \cdots & {A_{1n} } \\ {A_{21} } & {A_{22} } & {A_{23} } & \cdots & {A_{2n} } \\ {A_{31} } & {A_{32} } & {A_{33} } & \cdots & {A_{3n} } \\ \vdots & \vdots & \vdots & \ddots & \vdots \\ {A_{n1} } & {A_{n2} } & {A_{n3} } & \cdots & {A_{nn} } \\ \end{array} } \right]. $$
(1)

2.2 Full Matrix Focusing Imaging Algorithm

Imaging algorithm according to the full matrix data is shown schematically in Figure 1. The imaging region below the transducers is discretized into many focus points in alignment. Taking focus point P as an example, the distances between the point P and two elements i, j can be calculated. The amplitude Aij(t0) in the signal Aij can be determined according to the corresponding travel time t0. The amplitudes from all A-scan signals is superimposed with the same rule. Thus the digital amplitude of the focus point P \(I_{{\text{P}}} \left( {x,z} \right)\) can be calculated according to Eq. (2).
$$ I_{{\text{P}}} \left( {x,z} \right) = \sum\limits_{i = 1}^{N} {\sum\limits_{j = 1}^{N} {A_{ij} \left( {t_{0} } \right)} } , $$
(2)
$$ t_{0} = \left( {\sqrt {\left( {x_{i} - x} \right)^{2} + z^{2} } + \sqrt {\left( {x_{j} - x} \right)^{2} + z^{2} } } \right)/c, $$
(3)
where c is the wave speed in the material.

2.3 Triangular Matrix Focusing Imaging Algorithm

The full-matrix focus imaging algorithm needs all A-scan data acquisition and superposition, so it is a time-consuming method. Considering the reciprocity principle of the multi-channel acoustic system, the transmit and receive channels are interchanged. A good consistency in A-scan amplitudes is maintained. The Aij signal (the i element is transmitted, and the j element is received) should have a good consistency with the Aji signal (the j element is transmitted, and the i element is received). Then, the full matrix data shown in Eq. (1) is a symmetric matrix. It is sufficient that the imaging algorithm only use the upper triangular matrix signal, as shown in Eq. (4). It is called as the triangular matrix focusing imaging algorithm according to Eq. (5).
$$ \left[ {\begin{array}{*{20}c} {A_{11} } & {A_{12} } & {A_{13} } & \cdots & {A_{1n} } \\ {A_{21} } & {A_{22} } & {A_{23} } & \cdots & {A_{2n} } \\ {A_{31} } & {A_{32} } & {A_{33} } & \cdots & {A_{3n} } \\ \vdots & \vdots & \vdots & \ddots & \vdots \\ {A_{n1} } & {A_{n2} } & {A_{n3} } & \cdots & {A_{nn} } \\ \end{array} } \right], $$
(4)
$$ I_{{\text{P}}} \left( {x,z} \right) = \sum\limits_{i = 1}^{N} {\sum\limits_{j \ge i}^{N} {A_{ij} \left( {t_{0} } \right)} } . $$
(5)
Comparing Eqs. (1) and (2) to Eqs. (4) and (5), the amount of data acquisition and calculation is reduced from n×n to n×(n+1)/2. Then the amount of both data transfer, storage and calculation will be almost reduced by half.

2.4 Trapezoidal Matrix Focusing Imaging Algorithm

In order to improve the computational efficiency, the signal energy weights of different channels to the focus point are also considered. Synthetic aperture focusing technique (SAFT) is very useful method. The data on the main diagonal of the matrix is used in SAFT. The transmitting element is same as the receiving element. For a given focus point as shown in Figure 2, the A-scan amplitude is weaken with the distance from the transmitter to the receiver element increasing. Taking path1, path2 and path3 in Figure 2 as an example, with the travelled distance increasing from the focus point, the A-scan amplitude of the receiving element i, j and n is weaken gradually.
It is easy to find that the data with larger energy weight are distributed near the diagonal of the triangular matrix. Therefore, the data near to the diagonal of the triangular matrix is reserved, and data far from the diagonal of the triangular matrix is ignored. Then, the trapezoidal matrix focusing imaging algorithm is determined as shown in Eqs. (6) and (7).
$$ \left[ {\begin{array}{*{20}c} {A_{11} } & {A_{12} } & {A_{13} } & \cdots & {A_{1n} } \\ {A_{21} } & {A_{22} } & {A_{23} } & \cdots & {A_{2n} } \\ {A_{31} } & {A_{32} } & {A_{33} } & \cdots & {A_{3n} } \\ \vdots & \vdots & \vdots & \ddots & \vdots \\ {A_{n1} } & {A_{n2} } & {A_{n3} } & \cdots & {A_{nn} } \\ \end{array} } \right], $$
(6)
$$ I_{{\text{P}}} \left( {x,z} \right) = \sum\limits_{i = 1}^{N} {\sum\limits_{i \le j \le k}^{N} {A_{ij} \left( {t_{0} } \right)} } , $$
(7)
where \(i < k < N\).
After obtaining the superposition amplitude of each focusing point, the original image needs to be normalized for the digital display. The 256 colors bar is often used in the ultrasonic NDT field. The superposition amplitudes are normalized from − 127 to 128 using Eqs. (8) and (9).
If \(I_{{\text{P}}} \left( {x,z} \right) > 0,\)
$$ I_{{\text{P}}} \left( {x,z} \right) = \frac{{I_{{\text{P}}} \left( {x,z} \right)}}{{I\left( {x,z} \right)_{\max } }} \times 128, $$
(8)
If \(I_{{\text{P}}} \left( {x,z} \right) \le 0,\)
$$ I_{{\text{P}}} \left( {x,z} \right) = - \frac{{I_{{\text{P}}} \left( {x,z} \right)}}{{I\left( {x,z} \right)_{{{\text{min}}}} }} \times 127. $$
(9)

3 Experimental Verification

Both symmetric side-drilled holes and asymmetric oblique cracks are used in the experiment. The experiments are analyzed imaging quality and calculation efficiency with different matrix focusing imaging algorithm. The data acquisition and imaging experiments are based on an AOS 64×64 ultrasonic phased array system and independent-research-and-development imaging software. The sampling frequency of each channel is 100MSPS. A linear array with 5 MHz center frequency and 0.6 mm element center distance is used in the experiment. Due to the large amount of data collected using the full matrix focus method, only 32 channels and elements are used in the data acquisition.
Symmetric side-driller holes with 1.5 mm diameter are fabricated in an aluminum alloy specimen, as shown in Figure 3(a). Three asymmetric cracks with different tilt angles of 30°, 45° and 60° are fabricated at the bottom of the low carbon steel, as shown in Figure 3(b).

3.1 Comparison of Signal Consistency and Energy Weight

Considering the reciprocity principle of the A-scan signals, the transmitter and receiver channels are interchanged. Some pairs of A-scan signals are selected randomly from the full matrix data, as shown in Figure 4. Figure 4(a) shows that the signal of the symmetric side-drilled holes, and Figure 4(b)–(d) shows the signal of asymmetric oblique cracks. It can be seen from the results that the A5-21 signal always keeps good consistency with A21-5 signal. Both phase and amplitude of A5-21 and A21-5 are almost same, and signal amplitude in the near field part is slightly different. The rule can also be found in any pair of Aij and Aji channels in the full matrix data. Therefore, the full matrix data is a symmetric matrix.
As shown in Figure 5, A-scan signals are side-drill hole response with 6th element fired and 6th, 15th, 23rd element received. It can be seen that, as the distance from the transmitter to the receiver increasing, the amplitude of side-drill hole response is gradually decreased and time delay is increased. The data energy weight is lower as far away from the main diagonal of the matrix.

3.2 Comparison of Imaging Quality

Comparison of different matrix focus imaging methods is shown in Figures 6, 7, 8 and 9. Figure 6 shows the different matrix focus imaging of symmetric defects, and Figures 7, 8 and 9 show the different matrix focus imaging of asymmetric cracks with oblique angle of 30°, 45° and 60°. It is difficult to identify the difference of the four algorithms in those imaging results observationally. The holes and crack tip signals with different oblique angles can be found clearly. And the crack oblique angle can be evaluated according to the missing position of bottom reflection to the crack tip position as shown in Figures 7, 8 and 9. These patterns can be found in a good consistency with original full matrix focusing method, provided triangular matrix focusing method and provided the trapezoidal matrix focusing method.
In order to analyze consistency of original full matrix focusing method, provided triangular matrix focusing method and provided the trapezoidal matrix focusing method, A-scan signals of side-drilled holes and oblique cracks are shown in Figure 10. It can be seen that amplitude and phase of the synthesized A-scan signals are in good consistency with the three matrix focusing methods.
The signal-to-noise ratio (SNR) of echo signal are calculated separately. The peak value of the signal is regarded as Vs, and the average amplitude of noise as Vn. Then the SNR is calculated according to the signal peak value and the average amplitude of noise using Eq. (10).
$$SNR = 20 \times \log_{10} \left( {V_{S} /V_{n} } \right).$$
(10)
Echo signal SNR of oblique cracks and side-driller holes are shown in Figure 11 with original full matrix focusing method, provided triangular matrix focusing method and provided the trapezoidal matrix focusing method. Obviously, the SNR of the triangular matrix focusing algorithm is almost the same as that of the full matrix focusing algorithm. And the slightly difference is found in that of the trapezoidal matrix focusing algorithm. As decreasing the number of A-scan data (k from 16 to 12), SNR of the trapezoidal matrix is decreased.
The computational efficiencies of original full matrix focusing method, provided triangular matrix focusing method and provided the trapezoidal matrix focusing method are figured out as shown in Figure 12. B-scan image with 115×150 pixels is used to compare the imaging time with the three methods. It can be seen that the full matrix focusing is a time-consuming method. The calculation time of the triangular matrix focusing method is cut in half to that of full matrix focusing method. The trapezoidal matrix focusing method spends shorter time as decreasing the number of A-scan data (k from 16 to 12). Therefore, the computation efficiency can be improved greatly with the help of both provided triangular and trapezoidal matrix algorithms.

4 Conclusions

(1)
Based on the reciprocity principle, the triangular matrix focusing algorithm is provided to simplify the full matrix focusing method. Furthermore, the trapezoidal matrix focusing algorithm is proposed based on the signal energy weight.
 
(2)
The experimental results of side-drilled holes and oblique cracks show that, three imaging methods keep a great agreement in both B-scan images and synthesized A-scan signals. The signal-to-noise ratio of the triangular matrix is almost same as full matrix focusing algorithm. And the signal-to-noise ratio of the trapezoidal matrix are slightly lower as deceasing the amount of A-scan data.
 
(3)
The triangular and trapezoidal matrix algorithms can achieve the good imaging quality and increase the computation efficiency greatly.
 

Acknowledgements

Not applicable.

Competing interests

The authors declare no competing financial interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
Literature
[1]
go back to reference G Yang, N Du. Phased array three-dimensional all-focus imaging detection technology. NDT & E, 2018, 40(5): 64–67. G Yang, N Du. Phased array three-dimensional all-focus imaging detection technology. NDT & E, 2018, 40(5): 64–67.
[2]
go back to reference J P Jiao, S F Yang. Research on phase-weighted vector all-focus ultrasound array imaging method. Acta Acoustics, 2017, 42(4): 485–494. J P Jiao, S F Yang. Research on phase-weighted vector all-focus ultrasound array imaging method. Acta Acoustics, 2017, 42(4): 485–494.
[3]
go back to reference Y Lin. Ultrasonic phased array full-focus imaging detection. Nondestructive Testing, 2017, 39(5): 57–64. Y Lin. Ultrasonic phased array full-focus imaging detection. Nondestructive Testing, 2017, 39(5): 57–64.
[4]
go back to reference Z Q Zhou, Y Li. Research, application and development of phased array ultrasonic post-processing imaging technology. Chinese Journal of Mechanical Engineering, 2016, 52(6):1–11.CrossRef Z Q Zhou, Y Li. Research, application and development of phased array ultrasonic post-processing imaging technology. Chinese Journal of Mechanical Engineering, 2016, 52(6):1–11.CrossRef
[5]
go back to reference L Lin, P H Yang, D H Zhang. Review of phased array ultrasonic testing for thick wall cast austenitic stainless steel pipeline welds. Journal of Mechanical Engineering, 2012, 48(4): 12–20.CrossRef L Lin, P H Yang, D H Zhang. Review of phased array ultrasonic testing for thick wall cast austenitic stainless steel pipeline welds. Journal of Mechanical Engineering, 2012, 48(4): 12–20.CrossRef
[6]
go back to reference C Li, D Pain, P D Wilcox. Imaging composite material using ultrasonic arrays. NDT & International, 2013, 53 (16): 8–17.CrossRef C Li, D Pain, P D Wilcox. Imaging composite material using ultrasonic arrays. NDT & International, 2013, 53 (16): 8–17.CrossRef
[7]
go back to reference X Y Zhao, T Gang, B X Zhang. Prediction of radiation beam fields from an array transducer with nonparaxial multi-Gaussian beam model. Acta Acustica, 2008, 33(5): 475–480. X Y Zhao, T Gang, B X Zhang. Prediction of radiation beam fields from an array transducer with nonparaxial multi-Gaussian beam model. Acta Acustica, 2008, 33(5): 475–480.
[8]
go back to reference X Y Zhao, T Gang. Nonparaxial multi-Gaussian beam models and measurement models for phased array transducers. Ultrasonics, 2009, 49(1): 126–130.MathSciNetCrossRef X Y Zhao, T Gang. Nonparaxial multi-Gaussian beam models and measurement models for phased array transducers. Ultrasonics, 2009, 49(1): 126–130.MathSciNetCrossRef
[9]
go back to reference Z Pan, B J Zhang. Quantitative simulation of tilted cracks with ultrasonic phased array all-focus imaging technology. China Test, 2020, 46(4): 36–41.MathSciNet Z Pan, B J Zhang. Quantitative simulation of tilted cracks with ultrasonic phased array all-focus imaging technology. China Test, 2020, 46(4): 36–41.MathSciNet
[10]
go back to reference Y Jing, B Wu. Ultrasonic array full-focus imaging method for anisotropic weld defects. Acta Acoustics, 2019, 44(1): 125–135. Y Jing, B Wu. Ultrasonic array full-focus imaging method for anisotropic weld defects. Acta Acoustics, 2019, 44(1): 125–135.
[11]
go back to reference J Q Liu, H Y Zhang. Ultrasonic phased array wavenumber imaging algorithm for rail defects. Applied Acoustics, 2018, 37(6): 835–842. J Q Liu, H Y Zhang. Ultrasonic phased array wavenumber imaging algorithm for rail defects. Applied Acoustics, 2018, 37(6): 835–842.
[12]
go back to reference Y Chen, Q Q Ma. Research on fast all-focus ultrasound imaging based on Omega-K algorithm. Chinese Journal of Scientific Instrument, 2018, 39(9): 128–134. Y Chen, Q Q Ma. Research on fast all-focus ultrasound imaging based on Omega-K algorithm. Chinese Journal of Scientific Instrument, 2018, 39(9): 128–134.
[13]
go back to reference C Holmes, B W Drinkwater, P D Wilcox. Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation. NDT&E International, 2005, 38(8): 701–711.CrossRef C Holmes, B W Drinkwater, P D Wilcox. Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation. NDT&E International, 2005, 38(8): 701–711.CrossRef
[14]
go back to reference B Wu, J Yang, J P Jiao. Study on ultrasonic multi-mode composite total focusing imaging method for welds defect inspection in small-diameter tube of austenitic stainless steel. Journal of Mechanical Engineering, 2020, 56(14): 9–18.CrossRef B Wu, J Yang, J P Jiao. Study on ultrasonic multi-mode composite total focusing imaging method for welds defect inspection in small-diameter tube of austenitic stainless steel. Journal of Mechanical Engineering, 2020, 56(14): 9–18.CrossRef
[15]
go back to reference Z Pan, B J Zhang, H L Wang. Simulation on inclined cracks sizing of using the ultrasonic phased array total focusing imaging technique. China Measurement & Test, 2020, 46(4): 37–41. Z Pan, B J Zhang, H L Wang. Simulation on inclined cracks sizing of using the ultrasonic phased array total focusing imaging technique. China Measurement & Test, 2020, 46(4): 37–41.
[16]
go back to reference B Wu, J Yang, J P Jiao. Study on ultrasonic array imaging method for aluminum container welds. Journal of Mechanical Engineering, 2020, 56(14): 9–18. B Wu, J Yang, J P Jiao. Study on ultrasonic array imaging method for aluminum container welds. Journal of Mechanical Engineering, 2020, 56(14): 9–18.
[17]
go back to reference J G Wang, H Yao, H J Luo. Study on ultrasonic array imaging method for aluminum container welds. Experimental Mechanics, 2018, 33(4): 517–524. J G Wang, H Yao, H J Luo. Study on ultrasonic array imaging method for aluminum container welds. Experimental Mechanics, 2018, 33(4): 517–524.
[18]
go back to reference X W Shen. Full focus imaging of sparse array ultrasonic phased array based on particle swarm optimization. Applied Acoustics, 2020, 39(3): 354–359. X W Shen. Full focus imaging of sparse array ultrasonic phased array based on particle swarm optimization. Applied Acoustics, 2020, 39(3): 354–359.
[19]
go back to reference S A Yang. Design of ultrasonic phased array real-time full focus system based on FPGA. Wuhan: University of Chinese Academy of Sciences (Wuhan Institute of physics and mathematics, Chinese Academy of Sciences), 2020. S A Yang. Design of ultrasonic phased array real-time full focus system based on FPGA. Wuhan: University of Chinese Academy of Sciences (Wuhan Institute of physics and mathematics, Chinese Academy of Sciences), 2020.
[20]
go back to reference P J Chen. Debonding detection of composite shell engine based on phased array ultrasound. Taiyuan: Zhongbei University, 2021. P J Chen. Debonding detection of composite shell engine based on phased array ultrasound. Taiyuan: Zhongbei University, 2021.
[21]
go back to reference J Zhang, M R Yang. Comparative analysis of ultrasonic phased array full focus imaging algorithms. Acoustic technology, 2021, 40(1): 71–76. J Zhang, M R Yang. Comparative analysis of ultrasonic phased array full focus imaging algorithms. Acoustic technology, 2021, 40(1): 71–76.
[22]
go back to reference Y Chen, Q Q Mao, G Chen. Research on fast full focus ultrasound imaging based on omega-k algorithm. Journal of Instrumentation, 2018, 39(9): 128–134. Y Chen, Q Q Mao, G Chen. Research on fast full focus ultrasound imaging based on omega-k algorithm. Journal of Instrumentation, 2018, 39(9): 128–134.
[23]
go back to reference H Q Wu. Acquisition method of coded ultrasonic sparse data and plate weld defect imaging based on FPGA. Zhenjiang: Jiangsu University, 2020. H Q Wu. Acquisition method of coded ultrasonic sparse data and plate weld defect imaging based on FPGA. Zhenjiang: Jiangsu University, 2020.
[24]
go back to reference M L Zhao. Research on defect detection of double-layer structure based on full matrix phase transfer algorithm. Chengdu: Southwest Jiaotong University, 2020. M L Zhao. Research on defect detection of double-layer structure based on full matrix phase transfer algorithm. Chengdu: Southwest Jiaotong University, 2020.
[25]
go back to reference L C Jia, S L Chen, Z L Bai. Calibration model and acceleration algorithm of ultrasonic full focus imaging. Journal of instrumentation, 2017, 38(7): 1589–1596. L C Jia, S L Chen, Z L Bai. Calibration model and acceleration algorithm of ultrasonic full focus imaging. Journal of instrumentation, 2017, 38(7): 1589–1596.
[26]
go back to reference C Ran. Research on fast ultrasonic full focus imaging based on FPGA. Chengdu: Southwest Jiaotong University, 2017. C Ran. Research on fast ultrasonic full focus imaging based on FPGA. Chengdu: Southwest Jiaotong University, 2017.
[27]
go back to reference H R Jin, J Chen. An efficient wavenumber algorithm towards real-time ultrasonic full-matrix imaging of multi-layered medium. Mechanical Systems and Signal Processing, 2021: 149. H R Jin, J Chen. An efficient wavenumber algorithm towards real-time ultrasonic full-matrix imaging of multi-layered medium. Mechanical Systems and Signal Processing, 2021: 149.
[28]
go back to reference H Zhang, J Zheng, B Bai. Optimal design of sparse array for ultrasonic total focusing method by binary particle swarm optimization. IEEE Access, 2020, 8: 111945–111953.CrossRef H Zhang, J Zheng, B Bai. Optimal design of sparse array for ultrasonic total focusing method by binary particle swarm optimization. IEEE Access, 2020, 8: 111945–111953.CrossRef
[29]
go back to reference H W Hu, J Du. Ultrasonic phased array sparse-TFM imaging based on sparse array optimization and new edge-directed interpolation. Sensors, 2018, 18(6): 1830–1845.CrossRef H W Hu, J Du. Ultrasonic phased array sparse-TFM imaging based on sparse array optimization and new edge-directed interpolation. Sensors, 2018, 18(6): 1830–1845.CrossRef
[30]
go back to reference H W Hu, J Du, N Xu. Ultrasonic sparse-TFM imaging for a two-layer medium using genetic algorithm optimization and effective aperture correction. NDT & E International, 2017, 90: 24–32.CrossRef H W Hu, J Du, N Xu. Ultrasonic sparse-TFM imaging for a two-layer medium using genetic algorithm optimization and effective aperture correction. NDT & E International, 2017, 90: 24–32.CrossRef
Metadata
Title
Simplified Matrix Focusing Imaging Algorithm for Ultrasonic Nondestructive Testing
Authors
Xinyu Zhao
Zemin Ma
Jiaying Zhang
Publication date
01-12-2022
Publisher
Springer Singapore
Published in
Chinese Journal of Mechanical Engineering / Issue 1/2022
Print ISSN: 1000-9345
Electronic ISSN: 2192-8258
DOI
https://doi.org/10.1186/s10033-022-00682-8