Skip to main content
Top

2019 | OriginalPaper | Chapter

Statistical Shape Clustering of Left Atrial Appendages

Authors : Jakob M. Slipsager, Kristine A. Juhl, Per E. Sigvardsen, Klaus F. Kofoed, Ole De Backer, Andy L. Olivares, Oscar Camara, Rasmus R. Paulsen

Published in: Statistical Atlases and Computational Models of the Heart. Atrial Segmentation and LV Quantification Challenges

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Fifteen percent of all strokes are caused by emboli formed in the left atrium (LA) in case of atrial fibrillation (AF). The most common site of thrombus formation is inside the left atrial appendage (LAA). The LAA is accounting for 70% to 90% of the thrombi formed in the LA in patients with non-valvular AF. Studies have shown there is a correlation between the LAA morphology and risk of ischemic stroke; Chicken Wing and Cauliflower LAA shapes are associated with lower and higher risk, respectively. These two LAA shape categories come from a popular classification in the medical domain, but it is subjective and based on qualitative shape parameters. In this paper, we describe a full framework for shape analysis and clustering of the LAA. Initially, we build a point distribution model to quantitatively describe the LAA shape variation based on 103 LAA surfaces segmented and reconstructed from multidetector computed tomography volumes. We are successfully able to determine point correspondence between LAA surfaces, by non-rigid volumetric registration of signed distance fields. To validate if LAA shapes are clustered, we employ an unsupervised clustering on the shape models parameters to estimate the natural number of clusters in our training set, where the number of shape clusters is estimated by validating the test log-likelihood of several Gaussian mixture models using two level cross-validation. We found that the LAAs surfaces basically formed two shape clusters broadly corresponding to the Chicken wing and non-Chicken Wing morphologies, which fits well with clinical knowledge.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Bishop, C.M.: Pattern Recognition and Machine Learning, 1st edn. Springer, New York (2006)MATH Bishop, C.M.: Pattern Recognition and Machine Learning, 1st edn. Springer, New York (2006)MATH
3.
go back to reference Cootes, T.F., Taylor, C.J., Cooper, D.H., Graham, J.: Active shape models-their training and application. Comput. Vis. Image Underst. 61(1), 38–59 (1995)CrossRef Cootes, T.F., Taylor, C.J., Cooper, D.H., Graham, J.: Active shape models-their training and application. Comput. Vis. Image Underst. 61(1), 38–59 (1995)CrossRef
4.
go back to reference Di Biase, L., et al.: Does the left atrial appendage morphology correlate with the risk of stroke in patients with atrial fibrillation?: results from a multicenter study. J. Am. Coll. Cardiol. 60(6), 531–538 (2012)CrossRef Di Biase, L., et al.: Does the left atrial appendage morphology correlate with the risk of stroke in patients with atrial fibrillation?: results from a multicenter study. J. Am. Coll. Cardiol. 60(6), 531–538 (2012)CrossRef
5.
go back to reference Ernst, G., et al.: Morphology of the left atrial appendage. Anat. Rec. 242(4), 553–561 (1995)CrossRef Ernst, G., et al.: Morphology of the left atrial appendage. Anat. Rec. 242(4), 553–561 (1995)CrossRef
6.
go back to reference Fuchs, A., et al.: Normal values of left ventricular mass and cardiac chamber volumes assessed by 320-detector computed tomography angiography in the copenhagen general population study. Eur. Heart J.-Cardiovasc. Imaging 17(9), 1009–1017 (2016)CrossRef Fuchs, A., et al.: Normal values of left ventricular mass and cardiac chamber volumes assessed by 320-detector computed tomography angiography in the copenhagen general population study. Eur. Heart J.-Cardiovasc. Imaging 17(9), 1009–1017 (2016)CrossRef
7.
go back to reference Go, A.S., et al.: Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the anticoagulation and risk factors in atrial fibrillation (ATRIA) study. JAMA 285(18), 2370–2375 (2001)CrossRef Go, A.S., et al.: Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the anticoagulation and risk factors in atrial fibrillation (ATRIA) study. JAMA 285(18), 2370–2375 (2001)CrossRef
8.
go back to reference Khurram, I.M., et al.: Relationship between left atrial appendage morphology and stroke in patients with atrial fibrillation. Heart Rhythm 10(12), 1843–1849 (2013)CrossRef Khurram, I.M., et al.: Relationship between left atrial appendage morphology and stroke in patients with atrial fibrillation. Heart Rhythm 10(12), 1843–1849 (2013)CrossRef
9.
go back to reference Klein, S., Pluim, J.P., Staring, M., Viergever, M.A.: Adaptive stochastic gradient descent optimisation for image registration. Int. J. Comput. Vis. 81(3), 227 (2009)CrossRef Klein, S., Pluim, J.P., Staring, M., Viergever, M.A.: Adaptive stochastic gradient descent optimisation for image registration. Int. J. Comput. Vis. 81(3), 227 (2009)CrossRef
10.
go back to reference Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)CrossRef Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)CrossRef
11.
go back to reference Lorensen, W.E., Cline, H.E.: Marching cubes: a high resolution 3D surface construction algorithm. ACM SIGGRAPH Comput. Graph. 21, 163–169 (1987)CrossRef Lorensen, W.E., Cline, H.E.: Marching cubes: a high resolution 3D surface construction algorithm. ACM SIGGRAPH Comput. Graph. 21, 163–169 (1987)CrossRef
12.
go back to reference Nordestgaard, B.G., et al.: The effect of elevated body mass index on ischemic heart disease risk: causal estimates from a mendelian randomisation approach. PLoS Med. 9(5), e1001212 (2012)CrossRef Nordestgaard, B.G., et al.: The effect of elevated body mass index on ischemic heart disease risk: causal estimates from a mendelian randomisation approach. PLoS Med. 9(5), e1001212 (2012)CrossRef
13.
go back to reference Paulsen, R.R., Baerentzen, J.A., Larsen, R.: Markov random field surface reconstruction. IEEE Trans. Vis. Comput. Graph. 16(4), 636–646 (2010)CrossRef Paulsen, R.R., Baerentzen, J.A., Larsen, R.: Markov random field surface reconstruction. IEEE Trans. Vis. Comput. Graph. 16(4), 636–646 (2010)CrossRef
16.
go back to reference Rusinkiewicz, S., Levoy, M.: Efficient variants of the ICP algorithm. In: 2001 Proceedings of the Third International Conference on 3-D Digital Imaging and Modeling, pp. 145–152. IEEE (2001) Rusinkiewicz, S., Levoy, M.: Efficient variants of the ICP algorithm. In: 2001 Proceedings of the Third International Conference on 3-D Digital Imaging and Modeling, pp. 145–152. IEEE (2001)
17.
go back to reference Wunderlich, N.C., Beigel, R., Swaans, M.J., Ho, S.Y., Siegel, R.J.: Percutaneous interventions for left atrial appendage exclusion: options, assessment, and imaging using 2D and 3D echocardiography. JACC Cardiovasc. Imaging 8(4), 472–488 (2015)CrossRef Wunderlich, N.C., Beigel, R., Swaans, M.J., Ho, S.Y., Siegel, R.J.: Percutaneous interventions for left atrial appendage exclusion: options, assessment, and imaging using 2D and 3D echocardiography. JACC Cardiovasc. Imaging 8(4), 472–488 (2015)CrossRef
Metadata
Title
Statistical Shape Clustering of Left Atrial Appendages
Authors
Jakob M. Slipsager
Kristine A. Juhl
Per E. Sigvardsen
Klaus F. Kofoed
Ole De Backer
Andy L. Olivares
Oscar Camara
Rasmus R. Paulsen
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-030-12029-0_4

Premium Partner