Skip to main content
Top

2023 | OriginalPaper | Chapter

Study on High Flux at Shutdown Alarm Setpoint Automatic Update Logic

Authors : Wen-Qing Yang, Xiao-Fei Li, Wen-Qian Liu, Chao Wang, Bo Lv, Ji-Kun Liu, Hao Luo

Published in: New Energy Power Generation Automation and Intelligent Technology

Publisher: Springer Nature Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The source range of the nuclear instrumentation system (RPN) is used to monitor the reactor neutron flux from shutdown to initial startup. When the count rate measured by source range detector is higher than the set value, a “high flux at shutdown alarm” will be triggered. This alarm alerts the operators that positive reactivity has been added to the core, such as unexpected dilution or control rods withdrawal. This paper analyzes the source range high flux at shutdown alarm setpoint update logic of a nuclear power plant. It is found that the setpoint will be updated to a low value after the source range is automatically put into operation, resulting in false triggering of the alarm. This paper discusses the avoidance measures of alarm false triggering from the perspective of operational administration and control logic optimization. The results show that both measures are feasible.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Mao, H., Xiong, W., Que, J., et al.: The principle and engineering practice of ex-core nuclear instrumentation system in nuclear power plant. Nucl. Electron. Detect. Technol. 34(6), 758–761 (2014) Mao, H., Xiong, W., Que, J., et al.: The principle and engineering practice of ex-core nuclear instrumentation system in nuclear power plant. Nucl. Electron. Detect. Technol. 34(6), 758–761 (2014)
2.
go back to reference Wang, X.: Analysis of Boron Dilution Accident. China Nuclear Power Design Co., ltd, Shenzhen (2014) Wang, X.: Analysis of Boron Dilution Accident. China Nuclear Power Design Co., ltd, Shenzhen (2014)
3.
go back to reference Li, L., Wang, Z., Guan, Z., et al.: The effect of statistical fluctuation on control operation and the method of its elimination in nuclear gauge. Nucl. Electron. Detect. Technol. 2, 87–91 (1993) Li, L., Wang, Z., Guan, Z., et al.: The effect of statistical fluctuation on control operation and the method of its elimination in nuclear gauge. Nucl. Electron. Detect. Technol. 2, 87–91 (1993)
4.
go back to reference Li, J., Fan, W.: Section 6.2 Alarm Card of Nuclear Instrumentation System (RPN) System Design Manual. Shenzhen CGN Engineering Design Co., Ltd. (2019) Li, J., Fan, W.: Section 6.2 Alarm Card of Nuclear Instrumentation System (RPN) System Design Manual. Shenzhen CGN Engineering Design Co., Ltd. (2019)
5.
go back to reference Xie, Z., Wu, H., Zhang, S.: Physical Analysis of Nuclear Reactors, pp. 240–242. Xi’an Jiaotong University Press, Xi’an (2004) Xie, Z., Wu, H., Zhang, S.: Physical Analysis of Nuclear Reactors, pp. 240–242. Xi’an Jiaotong University Press, Xi’an (2004)
6.
go back to reference Tang, B., Ge, L., Fang, F., et al.: Principles of Nuclear Radiation Measurement, pp. 120–125. Harbin Engineering University Press, Harbin (2011) Tang, B., Ge, L., Fang, F., et al.: Principles of Nuclear Radiation Measurement, pp. 120–125. Harbin Engineering University Press, Harbin (2011)
Metadata
Title
Study on High Flux at Shutdown Alarm Setpoint Automatic Update Logic
Authors
Wen-Qing Yang
Xiao-Fei Li
Wen-Qian Liu
Chao Wang
Bo Lv
Ji-Kun Liu
Hao Luo
Copyright Year
2023
Publisher
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-99-3455-3_2