The Intelligent Early Warning System for the Gale-Induced Transmission Tower Fault Probability

Authors : Nailong Zhang, Huazhao Wang, Yang Liu, Jianjun Liu, Lujun Zhang

Published in: Proceedings of PURPLE MOUNTAIN FORUM 2019-International Forum on Smart Grid Protection and Control

Publisher: Springer Nature Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Gale is one of the important reasons causing transmission tower collapse. Therefore, precisely prediction and early warning of the gale which may cause the transmission tower fall down can decrease the loss to power grid at utmost. In this paper, non-linear stepwise regression (NLSR) method is used to forecast gale in the power grid. To avoid the single statistical method errors, the back-propagation (BP) artificial neural network is used to optimize the results intelligently. Further, we consider the gale-induced tower failure rate, and couple it to the forecast model. Finally, we establish an intelligent gale-induced transmission tower fault warning system to predict the probability of accident. The simulated result shows that the accuracy of the model in predicting gale-induced transmissions tower fault probability is good.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Zhang LD, Shi H, Zhang YJ (2010) Analysis of causes and prevention methods for power network accidents. Syst Prot Control 38(4):130–133 Zhang LD, Shi H, Zhang YJ (2010) Analysis of causes and prevention methods for power network accidents. Syst Prot Control 38(4):130–133
2.
go back to reference Xing LW, Hu DY, Tang LL (2001) Development of typhoon disaster risk evaluations and early warning system integrating real-time rainfall data from the satellite. In: 19th international conference on Geoinformatics, pp 1–5 Xing LW, Hu DY, Tang LL (2001) Development of typhoon disaster risk evaluations and early warning system integrating real-time rainfall data from the satellite. In: 19th international conference on Geoinformatics, pp 1–5
3.
go back to reference Zhang Y, Zhao Y, Wang JL et al (2012) The influence of typhoon on the operations of power grid and countermeasures. South Power Syst Technol 6(1):42–45 Zhang Y, Zhao Y, Wang JL et al (2012) The influence of typhoon on the operations of power grid and countermeasures. South Power Syst Technol 6(1):42–45
4.
go back to reference Xie Q, Zhang Y, Li J (2006) Investingation on tower collapses of 500 kV renshang 5237 transmission line caused by downburst. Power Syst Technol 30(10):59–63 Xie Q, Zhang Y, Li J (2006) Investingation on tower collapses of 500 kV renshang 5237 transmission line caused by downburst. Power Syst Technol 30(10):59–63
5.
go back to reference Wen SJ (2012) Research of wind disaster early warning method for overhead transmission lines. Chongqing university, Chongqing Wen SJ (2012) Research of wind disaster early warning method for overhead transmission lines. Chongqing university, Chongqing
6.
go back to reference Chang H, Lin ZZ, Yang L et al (2018) Multi-dimensional critical line identification for regional power systems under typhoon. Autom Electr Power Syst 42(15):118–125 Chang H, Lin ZZ, Yang L et al (2018) Multi-dimensional critical line identification for regional power systems under typhoon. Autom Electr Power Syst 42(15):118–125
7.
go back to reference Xu WJ, Dai Y, Jan YL et al (2012) Probabilistic forecasting of transmission line damage and tower collapse from storm disaster. Cent China Electr Power 25(3):77–81 Xu WJ, Dai Y, Jan YL et al (2012) Probabilistic forecasting of transmission line damage and tower collapse from storm disaster. Cent China Electr Power 25(3):77–81
8.
go back to reference Yang FL, Zhang HJ, Yang JB et al (2014) Bearing capacity analysis and load values of transmission towers under thunderstorm downburst. Proc CSEE 34(24):4179–4186 Yang FL, Zhang HJ, Yang JB et al (2014) Bearing capacity analysis and load values of transmission towers under thunderstorm downburst. Proc CSEE 34(24):4179–4186
9.
go back to reference Gao Y, Yang JB (2015) Characteristics of airflow over typical micro-terrain and its application to design of overhead transmission and distribution lines. Electr Power 48(7):146–152 Gao Y, Yang JB (2015) Characteristics of airflow over typical micro-terrain and its application to design of overhead transmission and distribution lines. Electr Power 48(7):146–152
10.
go back to reference Yu F, Ji HL, Xue Y et al (2010) Prediction method establishment of strong wind at the Luoyang airport using the Nonlinear regression. Meteorol Environ Sci 33(4):53–58 Yu F, Ji HL, Xue Y et al (2010) Prediction method establishment of strong wind at the Luoyang airport using the Nonlinear regression. Meteorol Environ Sci 33(4):53–58
11.
go back to reference Yu C, Lyu YJ, Duan RH et al (2018) A forecast method of icing flashover fault based on partial mutual information method and support vector machine. Autom Electr Power Syst 42(2):92–98 Yu C, Lyu YJ, Duan RH et al (2018) A forecast method of icing flashover fault based on partial mutual information method and support vector machine. Autom Electr Power Syst 42(2):92–98
12.
go back to reference Wu YJ, Xue YS, Xie YY et al (2016) Space-time impact of typhoon and rainstorm on power grid fault probability. Autom Electr Power Syst 40(2):20–29 Wu YJ, Xue YS, Xie YY et al (2016) Space-time impact of typhoon and rainstorm on power grid fault probability. Autom Electr Power Syst 40(2):20–29
13.
go back to reference Chen QX (2002) Discussing into influence of topographic height difference on wind velocity. Shanxi Hydrotechnics 1:10–12 Chen QX (2002) Discussing into influence of topographic height difference on wind velocity. Shanxi Hydrotechnics 1:10–12
14.
go back to reference Bao B, Cheng RL, Xiong XF et al (2014) A typhoon risk early warning method for power transmission line considering micro-terrain correction. Power Syst Prot Control 42(14):79–86 Bao B, Cheng RL, Xiong XF et al (2014) A typhoon risk early warning method for power transmission line considering micro-terrain correction. Power Syst Prot Control 42(14):79–86
15.
go back to reference Xiong TH, Liang SG, Zou LH (2009) Dominant failure modes of a transmission tower and its ultimate capacity under wind load. Eng Mechanics 26(12):100–104CrossRef Xiong TH, Liang SG, Zou LH (2009) Dominant failure modes of a transmission tower and its ultimate capacity under wind load. Eng Mechanics 26(12):100–104CrossRef
16.
go back to reference Lou WJ, Sun BN, Ye Y (1999) Across-wind dynamic response of tall latticed towers. China Civil Eng J 32(6):67–71 Lou WJ, Sun BN, Ye Y (1999) Across-wind dynamic response of tall latticed towers. China Civil Eng J 32(6):67–71
17.
go back to reference Cheng ZJ, Fu GH (2000) Research for the wind force on high-rise latticed tower. J Experimental Mechanics 15(1):51–55MathSciNet Cheng ZJ, Fu GH (2000) Research for the wind force on high-rise latticed tower. J Experimental Mechanics 15(1):51–55MathSciNet
18.
go back to reference Xie YY, Xue SY, Wen FS et al (2013) Space-time evaluation for impact of ice disaster on transmission line fault probability. Autom Electr Power Syst 37(18):32–41 Xie YY, Xue SY, Wen FS et al (2013) Space-time evaluation for impact of ice disaster on transmission line fault probability. Autom Electr Power Syst 37(18):32–41
Metadata
Title
The Intelligent Early Warning System for the Gale-Induced Transmission Tower Fault Probability
Authors
Nailong Zhang
Huazhao Wang
Yang Liu
Jianjun Liu
Lujun Zhang
Copyright Year
2020
Publisher
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-13-9779-0_51