Underground cables have been used from the earliest time as integral parts of the power distribution and transmission system. Compared to their overhead analogues, they have been long regarded as the most critical of components due in part to their high total installed cost, their unique ampacity requirements, and the complexity of their installation. Thus, even from the very first technical papers, the sustainability, through reliability and longevity, has been of paramount importance. This contribution addresses the focus on sustainability today while maintaining a linkage to the lessons that have been already learned.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Moore GF (1997) Electrical cables handbook. Blackwell Science, San Diego. ISBN 0 632 04075 0 Moore GF (1997) Electrical cables handbook. Blackwell Science, San Diego. ISBN 0 632 04075 0
2.
go back to reference Densley J (1995) Ageing and diagnostics in extruded insulations for power cables. In: IEEE 5th international conference on conduction and breakdown in solid dielectrics, IEEE publication 95CH3476-9, pp 1–15 Densley J (1995) Ageing and diagnostics in extruded insulations for power cables. In: IEEE 5th international conference on conduction and breakdown in solid dielectrics, IEEE publication 95CH3476-9, pp 1–15
3.
go back to reference Fothergill JC, Hampton RN (2004) Polymer insulated cable. In: Haddad A, Warne D (eds) Advances in high voltage engineering. IEE, London, pp 477–507, Chapter 10. ISBN 0 85296 158 8CrossRef Fothergill JC, Hampton RN (2004) Polymer insulated cable. In: Haddad A, Warne D (eds) Advances in high voltage engineering. IEE, London, pp 477–507, Chapter 10. ISBN 0 85296 158 8CrossRef
4.
go back to reference Abernethy RB (1996) The new Weibull handbook, 2nd edn. Robert B. Abernethy, North Palm Beach. ISBN 0965306208MATH Abernethy RB (1996) The new Weibull handbook, 2nd edn. Robert B. Abernethy, North Palm Beach. ISBN 0965306208MATH
5.
go back to reference Hampton RN (2008) Some of the considerations for materials operating under High Voltage Direct Current Stresses. IEEE Electrical Insulation Magazine 24(1):5–13 Hampton RN (2008) Some of the considerations for materials operating under High Voltage Direct Current Stresses. IEEE Electrical Insulation Magazine 24(1):5–13
6.
go back to reference Leijon M (1999) Novel concept in high voltage generation: PowerformerTM. IEE Conference Publication, v5, n467, 1999. In: Proceedings of the 1999, 11th International symposium on “High Voltage Engineering”, 23–27 Aug 1999, London, UK, p 5.379.S5-5.382.P5, IEE, ISSN: 0537–9989 IECPB4 ISBN: 0-85296-719-5 Leijon M (1999) Novel concept in high voltage generation: PowerformerTM. IEE Conference Publication, v5, n467, 1999. In: Proceedings of the 1999, 11th International symposium on “High Voltage Engineering”, 23–27 Aug 1999, London, UK, p 5.379.S5-5.382.P5, IEE, ISSN: 0537–9989 IECPB4 ISBN: 0-85296-719-5
7.
go back to reference Jenkins N (2002) Power Engineering Journal 16(3):90–91 Jenkins N (2002) Power Engineering Journal 16(3):90–91
8.
go back to reference Karlstrand J, Sunnegardh P, Zenger W, Ghafurian R, Boggia R (2002) Water-cooled 345 kV solid-dielectric cable system, Cigré paper 21–111 Karlstrand J, Sunnegardh P, Zenger W, Ghafurian R, Boggia R (2002) Water-cooled 345 kV solid-dielectric cable system, Cigré paper 21–111
9.
go back to reference Halvarsson P, Karlstrand J, Larsson D, Larsson M, Reinholdsdóttir K, Sigurõsson E (2002) A novel approach to long buried AC transmission system, Cigré paper 21–201 Halvarsson P, Karlstrand J, Larsson D, Larsson M, Reinholdsdóttir K, Sigurõsson E (2002) A novel approach to long buried AC transmission system, Cigré paper 21–201
10.
go back to reference Bartnikas R, Eichhorn RM (eds) (1983) Engineering dielectrics, vol IIA, Electrical properties of solid insulation, Philadelphia, ASTM-STP 783 Bartnikas R, Eichhorn RM (eds) (1983) Engineering dielectrics, vol IIA, Electrical properties of solid insulation, Philadelphia, ASTM-STP 783
11.
go back to reference Diagnostic Testing of Underground Cable Systems (Cable Diagnostic Focused Initiative) DOE Award No. DE-FC02-04CH11237, December 2010 Diagnostic Testing of Underground Cable Systems (Cable Diagnostic Focused Initiative) DOE Award No. DE-FC02-04CH11237, December 2010
12.
go back to reference Dissado LA, Fothergill JC (1992) Electrical degradation and breakdown in polymers. In: Peter Peregrinuns for the IEE, LondonCrossRef Dissado LA, Fothergill JC (1992) Electrical degradation and breakdown in polymers. In: Peter Peregrinuns for the IEE, LondonCrossRef
13.
go back to reference Brincourt T, Regaudie V (1999) Evaluation of different diagnostic methods for the French underground MV network. In: JICABLE’99, Versailles, p 451 Brincourt T, Regaudie V (1999) Evaluation of different diagnostic methods for the French underground MV network. In: JICABLE’99, Versailles, p 451
14.
go back to reference Peschke E, Schroth R, Olshausen R (1995) Extension of XLPE cables to 500 kV based on progress in technology. In: JICABLE’95, Montreal, pp 6–10 Peschke E, Schroth R, Olshausen R (1995) Extension of XLPE cables to 500 kV based on progress in technology. In: JICABLE’95, Montreal, pp 6–10
15.
go back to reference Griffiths CL, Betteridge S, Hampton RN (1998) Thermoelectric ageing of cable grade XLPE in dry conditions. Conduction and breakdown in solid dielectrics ICSD '98. Proceedings of the 1998 IEEE 6th international conference, pp 279–282, doi:http://10.1109/ICSD.1998.709279 Griffiths CL, Betteridge S, Hampton RN (1998) Thermoelectric ageing of cable grade XLPE in dry conditions. Conduction and breakdown in solid dielectrics ICSD '98. Proceedings of the 1998 IEEE 6th international conference, pp 279–282, doi:http://​10.​1109/​ICSD.​1998.​709279
16.
go back to reference Coppard RW, Bowman J, Dissado LA, Roland SM, Rakowski RT (1990) The effect of aluminium inclusions on the dielectric breakdown strength of polyethylene. J Appl Phys 23:1554–1561 Coppard RW, Bowman J, Dissado LA, Roland SM, Rakowski RT (1990) The effect of aluminium inclusions on the dielectric breakdown strength of polyethylene. J Appl Phys 23:1554–1561
17.
go back to reference Antoniscki JR, Nilsson U, Gubanski SM (1997) The effect of metal inclusions on the breakdown strength of XLPE cables. In: CEIDP 1997, Minneapolis, pp 283–286 Antoniscki JR, Nilsson U, Gubanski SM (1997) The effect of metal inclusions on the breakdown strength of XLPE cables. In: CEIDP 1997, Minneapolis, pp 283–286
18.
go back to reference Hagen ST, Ildstad E (1993) Reduction of AC breakdown strength due to particle inclusions in XLPE cable insulation. In: Conference on power cables and accessories 10 kV–500 kV, London, pp 165–168 Hagen ST, Ildstad E (1993) Reduction of AC breakdown strength due to particle inclusions in XLPE cable insulation. In: Conference on power cables and accessories 10 kV–500 kV, London, pp 165–168
19.
go back to reference Blodgett RB (1962) Influence of absorbed water and temperature on tan delta and dielectric constant of oil-impregnated paper insulation. Trans AIEE 81:93–100 Blodgett RB (1962) Influence of absorbed water and temperature on tan delta and dielectric constant of oil-impregnated paper insulation. Trans AIEE 81:93–100
20.
go back to reference Hartlein RA, Hampton RN, Perkel J (2008) Some considerations on the selection of optimum location, timing, and technique, for diagnostic tests. In: IEEE Power Engineering Society (PES) general meeting panel session, Pittsburg Hartlein RA, Hampton RN, Perkel J (2008) Some considerations on the selection of optimum location, timing, and technique, for diagnostic tests. In: IEEE Power Engineering Society (PES) general meeting panel session, Pittsburg
21.
go back to reference Steennis EF (1989) Water treeing: the behaviour of water trees in extruded cable insulation. ISBN 90-353-1022-5, Kema, pp 132–133 Steennis EF (1989) Water treeing: the behaviour of water trees in extruded cable insulation. ISBN 90-353-1022-5, Kema, pp 132–133
22.
go back to reference Gregory B, Griffiths CL, Hampton RN and Mainwaring SP (2000) A probabilistic design method for polymeric structures to operate at high electrical stress. In: 8th international conference on dielectric materials, measurements and application, IEE Conference Publication no 473, pp 419–424 Gregory B, Griffiths CL, Hampton RN and Mainwaring SP (2000) A probabilistic design method for polymeric structures to operate at high electrical stress. In: 8th international conference on dielectric materials, measurements and application, IEE Conference Publication no 473, pp 419–424
23.
go back to reference Ogawa K, Kosugi T, Kato N, Kawawata Y (1990) The worlds first use of 500 kV XLPE insulated aluminium sheathed power cables at the Shimogo and Imaichi power stations. IEEE Trans Power Delivery 5(1):26–32CrossRef Ogawa K, Kosugi T, Kato N, Kawawata Y (1990) The worlds first use of 500 kV XLPE insulated aluminium sheathed power cables at the Shimogo and Imaichi power stations. IEEE Trans Power Delivery 5(1):26–32CrossRef
25.
go back to reference Gorham and Partners (1995) Undergrounding – A success story already in Europe – Potentially worldwide. Report to ICF Congress 1995 Gorham and Partners (1995) Undergrounding – A success story already in Europe – Potentially worldwide. Report to ICF Congress 1995
26.
go back to reference Campbell A (2003) Undergrounding HV and EHV – window of opportunity opens. In: ICF Congress 2003, St Petersburg, pp 169–193 Campbell A (2003) Undergrounding HV and EHV – window of opportunity opens. In: ICF Congress 2003, St Petersburg, pp 169–193
27.
go back to reference Hampton RN (2005) Electrical insulation systems for energy technology and clean environment. In: Nordic insulation symposium (NORDIS), Trondheim, June 2005 Hampton RN (2005) Electrical insulation systems for energy technology and clean environment. In: Nordic insulation symposium (NORDIS), Trondheim, June 2005
28.
go back to reference Hampton RN, Olearczyk M, Perkel J, Weisenfeld N (2010) Cable fleet management. IEEE Power and Engineering, Nov 2010 Hampton RN, Olearczyk M, Perkel J, Weisenfeld N (2010) Cable fleet management. IEEE Power and Engineering, Nov 2010
29.
go back to reference Perkel J, Hernández JC, Hampton RN, Drapeau JF, Densley (2011) Challenges associated with the interpretation of dielectric loss data from power cable system measurements. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, C.4.5 Perkel J, Hernández JC, Hampton RN, Drapeau JF, Densley (2011) Challenges associated with the interpretation of dielectric loss data from power cable system measurements. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, C.4.5
30.
go back to reference Drapeau J-F, Cantin B, Hampton N, Perkel J (2011) Dielectric loss characterization of hydro-quebec medium voltage (MV) submarine cables – phase 1. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper A.7.6 Drapeau J-F, Cantin B, Hampton N, Perkel J (2011) Dielectric loss characterization of hydro-quebec medium voltage (MV) submarine cables – phase 1. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper A.7.6
31.
go back to reference Fletcher CL, Perkel J, Hampton RN, Hernandez JC, Hesse J, Pearman MG, Wall CT, Zenger W (2011) First practical utility implementation of monitored withstand diagnostics in the USA. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper A.10.2 Fletcher CL, Perkel J, Hampton RN, Hernandez JC, Hesse J, Pearman MG, Wall CT, Zenger W (2011) First practical utility implementation of monitored withstand diagnostics in the USA. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper A.10.2
32.
go back to reference Parker T, Hampton RN (2011) Impact of filled-strand conductor on connector temperature for medium voltage joints. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper C.1.5 Parker T, Hampton RN (2011) Impact of filled-strand conductor on connector temperature for medium voltage joints. In: International conference on insulated power cables JICABLE11, Versailles France, June 2011, Paper C.1.5
Metadata
Title
Underground Cable Systems
Authors
Yamille Del Valle
Nigel Hampton
Josh Perkel
Caryn Riley
Copyright Year
2013
Publisher
Springer New York
DOI
https://doi.org/10.1007/978-1-4614-5830-2_7