Abstract

The contamination of insulators increases their surface conductivity, resulting in a higher chance of shutdowns occurring. To measure contamination, equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) are used. In this paper, the VGG-11, VGG-13, VGG-16, VGG-19, ResNet-18, ResNet-34, ResNet-50, ResNet-152, DenseNet-121, DenseNet-161, DenseNet-169, and DenseNet-201 convolutional neural networks (CNNs) were considered to classify the visible contamination of pin-type distribution power grid insulators. The NSDD presents more visual variation than ESDD when artificial contamination is evaluated. Comparing the CNNs, the ResNet-50 had the best performance for classifying visible contamination using unbalanced data with an accuracy of 99.242% and an F1-score of 0.97436, respectively. In benchmarking, the ResNet-50 outperformed well-established classifiers such as the multilayer perceptron, support vector machine, k-nearest neighbors, decision tree, ensemble bagged trees, and quadratic discriminant.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
14.
Zurück zum Zitat Zhao Z, Zhen Z, Zhang L, Qi Y, Kong Y, Zhang K (2019) Insulator detection method in inspection image based on improved faster r-cnn. Energies 12(7):1204CrossRef Zhao Z, Zhen Z, Zhang L, Qi Y, Kong Y, Zhang K (2019) Insulator detection method in inspection image based on improved faster r-cnn. Energies 12(7):1204CrossRef
40.
Zurück zum Zitat da Silva Júnior ET, de Aquino FJA, Silva DA, Rocha Neto AR, Gurgel KJA, de Oliveira AERM, de Araújo ALC (2018) Corona effect detection in energized polymeric insulators using machine learning and ultrasonic emissions. IEEE Latin Am Trans 16(6):1587–1594. https://doi.org/10.1109/TLA.2018.m19CrossRef da Silva Júnior ET, de Aquino FJA, Silva DA, Rocha Neto AR, Gurgel KJA, de Oliveira AERM, de Araújo ALC (2018) Corona effect detection in energized polymeric insulators using machine learning and ultrasonic emissions. IEEE Latin Am Trans 16(6):1587–1594. https://​doi.​org/​10.​1109/​TLA.​2018.​m19CrossRef
57.
Zurück zum Zitat IEC: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions: part 1: Definitions, information and general principles. In: International Electrotechnical Commission TS 60815-1, 1–53 (2008) IEC: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions: part 1: Definitions, information and general principles. In: International Electrotechnical Commission TS 60815-1, 1–53 (2008)
63.
Zurück zum Zitat Srivastava N, Hinton G, Krizhevsky A, Sutskever I, Salakhutdinov R (2014) Dropout: a simple way to prevent neural networks from overfitting. J Mach Learn Res 15(1):1929–1958MathSciNetMATH Srivastava N, Hinton G, Krizhevsky A, Sutskever I, Salakhutdinov R (2014) Dropout: a simple way to prevent neural networks from overfitting. J Mach Learn Res 15(1):1929–1958MathSciNetMATH
Metadaten
Titel
Evaluation of visible contamination on power grid insulators using convolutional neural networks
verfasst von
Marcelo Picolotto Corso
Stefano Frizzo Stefenon
Gurmail Singh
Marcos Vinicius Matsuo
Fábio Luis Perez
Valderi Reis Quietinho Leithardt
Publikationsdatum
14.07.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Electrical Engineering / Ausgabe 6/2023
Print ISSN: 0948-7921
Elektronische ISSN: 1432-0487
DOI
https://doi.org/10.1007/s00202-023-01915-2