Abstract

The filler is the important heat and mass transfer components of dehumidifier and regenerator in liquid desiccant system. The traditional gas–liquid direct contact filler meets an unfavorable factor which is gas with liquid. In this paper, a new indirect gas–liquid contact partitions filler, which has a specific surface area of 286 m2/m3 and a porosity of 0.86, is proposed. Both regeneration performance of the partitions filler and 5090 wet curtain has been tested on a cross-flow regeneration module laboratory. LiBr solution has been used as the desiccant and the regeneration effect is described by regeneration rate, renewable efficiency, average mass transfer coefficient, and volumetric mass transfer coefficient. The influence of the regeneration performance of the system is analyzed with solution inlet temperature. A regeneration performance comparison of the new filler and the 5090 wet curtain has been carried out. It shows the volumetric mass transfer coefficient of the filler is 7–36 % higher than the 5090 wet curtain one when the solution temperature is between 43 and 60 °C, and the quality of air with liquid of the new filler is 58–87 % lower than the 5090 wet curtain one when the face velocity is between 0.387 and 0.645 m/s.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chen X, Cong L, Zhang T et al. (2011) Liquid desiccant air handling technology research progress. HV&AC 41(1):21–27 Chen X, Cong L, Zhang T et al. (2011) Liquid desiccant air handling technology research progress. HV&AC 41(1):21–27
2.
Zurück zum Zitat Liu S, Liu X, Jiang Y et al. (2011) Nanhai E # 3 office temperature and humidity measurement and analysis of individually controlled air conditioning system. HV&AC 41(1):55–59 Liu S, Liu X, Jiang Y et al. (2011) Nanhai E # 3 office temperature and humidity measurement and analysis of individually controlled air conditioning system. HV&AC 41(1):55–59
3.
Zurück zum Zitat Gu Z, Liu Y, Huang D et al. (2011) Temperature and humidity independent control air-conditioning systems in large public buildings in the Beijing area applications. HV&AC 41(1):53 –54 Gu Z, Liu Y, Huang D et al. (2011) Temperature and humidity independent control air-conditioning systems in large public buildings in the Beijing area applications. HV&AC 41(1):53 –54
4.
Zurück zum Zitat Li Y, Hu R, Feng T (2011) Temperature and humidity independent control air-conditioning system in application of the Xiangxi courtyard two villa in Qingdao. HV&AC 41(1):42–47 Li Y, Hu R, Feng T (2011) Temperature and humidity independent control air-conditioning system in application of the Xiangxi courtyard two villa in Qingdao. HV&AC 41(1):42–47
5.
Zurück zum Zitat Chen Y, Pei Q, Xu G (2009) Liquid desiccant air conditioning air with liquid ion detection method and its application. Build Energy Environ 28(3):37–40 Chen Y, Pei Q, Xu G (2009) Liquid desiccant air conditioning air with liquid ion detection method and its application. Build Energy Environ 28(3):37–40
6.
Zurück zum Zitat Wang S (2007) Preliminary study of liquid desiccant air conditioning indoor air quality. Guangzhou University, Guangzhou Wang S (2007) Preliminary study of liquid desiccant air conditioning indoor air quality. Guangzhou University, Guangzhou
7.
Zurück zum Zitat Luo X, Li W, Cao Z (2011) The refrigerant rust change lithium bromide solution corrosive research. Light Ind Mach 29(1):104–107 Luo X, Li W, Cao Z (2011) The refrigerant rust change lithium bromide solution corrosive research. Light Ind Mach 29(1):104–107
8.
Zurück zum Zitat Jiang F, Cai Z, Lu Z (1999) BTA on the corrosion of carbon steel in lithium bromide solution. The Refrigeration 18(4):29–31 Jiang F, Cai Z, Lu Z (1999) BTA on the corrosion of carbon steel in lithium bromide solution. The Refrigeration 18(4):29–31
9.
Zurück zum Zitat Kumar R, Dhar PL, Jain S (2011) Development of new wire mesh packings for improving the performance of zero carryover spray tower. Energy 36:1362–1374CrossRef Kumar R, Dhar PL, Jain S (2011) Development of new wire mesh packings for improving the performance of zero carryover spray tower. Energy 36:1362–1374CrossRef
10.
Zurück zum Zitat An S, Wang J, Liu I et al. (2007) Liquid desiccant packed tower liquid entrainment and pressure drop problem. HV&AC 37(4):109–112 An S, Wang J, Liu I et al. (2007) Liquid desiccant packed tower liquid entrainment and pressure drop problem. HV&AC 37(4):109–112
11.
Zurück zum Zitat Zhang L, Liu J, Zhang H (2011) Liquid desiccant screen corrugated packing application characteristics research. Fluid Mach 39(6):48–52 Zhang L, Liu J, Zhang H (2011) Liquid desiccant screen corrugated packing application characteristics research. Fluid Mach 39(6):48–52
12.
Zurück zum Zitat Sun J, Shi M, Zhao Y (2003) Experimental study of the performance of liquid desiccant air conditioning regeneration. Eng Thermo Phys 24(5):867–869 Sun J, Shi M, Zhao Y (2003) Experimental study of the performance of liquid desiccant air conditioning regeneration. Eng Thermo Phys 24(5):867–869
13.
Zurück zum Zitat Luo L, Zhang X, Yin Y (2008) The experimental study of heat and mass transfer coefficients of Forks flow packing regenerator. J Eng Thermophys 29(7):1215–1217 Luo L, Zhang X, Yin Y (2008) The experimental study of heat and mass transfer coefficients of Forks flow packing regenerator. J Eng Thermophys 29(7):1215–1217
14.
Zurück zum Zitat Bassuoni MM (2011) An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant. Energy 36:2628–2638CrossRef Bassuoni MM (2011) An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant. Energy 36:2628–2638CrossRef
15.
Zurück zum Zitat Yin Y, Li S, Zhang X (2010) Adiabatic and heat- regenerative process thermal performance comparison. Chem Ind Eng 61(S2):157–162 Yin Y, Li S, Zhang X (2010) Adiabatic and heat- regenerative process thermal performance comparison. Chem Ind Eng 61(S2):157–162
16.
Zurück zum Zitat Wang Q, Wang G (2010) Theoretical research and experimental analysis of the solution regeneration of liquid desiccant air conditioning system performance. Refrig Air Condition 24(4):124–128 Wang Q, Wang G (2010) Theoretical research and experimental analysis of the solution regeneration of liquid desiccant air conditioning system performance. Refrig Air Condition 24(4):124–128
Metadaten
Titel
Experiment of a New Partitions Filler Regeneration Performance
verfasst von
Lining Zhou
Zhijia Huang
Liping Zhu
Ping Jiang
Copyright-Jahr
2014
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-39581-9_81