Experimental investigation on the suitability of flexible pressure sensor for wrist pulse measurement

verfasst von: Sukesh Rao M., Rathnamala Rao

Erschienen in: Health and Technology | Ausgabe 2/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Pulse examination at the radial artery of the wrist is a most apparent diagnosis technique. Wrist pulse carries rich information about the cardiovascular system of human body. An investigation is made here to suggest suitable flexible type of thin film pressure sensor to measure the wrist pulse as per Ayurvedic medicine system. Primary objective of this work is to suggest a sensor which exhibits optimum spatial features and SNR values. Force Sensing Resistor (FSR), piezoresistive and piezoelectric thin film sensors are considered under this study. Piezoelectric sensor shows good performance in the quality of the pulse with 22 dB SNR. Further experimentation is conducted to find out transmissivity, repeatability and susceptibility to motion artifact. Trasnsmissivities of 0.91, 0.68 and 0.64 are obtained for piezoelectric, piezoresistive and FSR sensors respectively. Piezoresistive and FSR show repeatability error of ±8% and ± 7% while measuring pulse amplitude under standard force. Noise due to motion artifact for each type of sensors are recorded and compared with the standard Gaussian distribution function with the help of histogram. Collectively, piezoelectric sensor exhibits good spatial features, high transmissivity and comparatively low susceptibility to motion artifact.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Nakajima K, Tamura T, Miike H. Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. Med Eng Phys. 1996;18(5):65–372.CrossRef Nakajima K, Tamura T, Miike H. Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. Med Eng Phys. 1996;18(5):65–372.CrossRef
2.
Zurück zum Zitat Mendelson Y, Ochs BD. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans Biomed Eng. 1988;35(10):798–805.CrossRef Mendelson Y, Ochs BD. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans Biomed Eng. 1988;35(10):798–805.CrossRef
3.
Zurück zum Zitat Lee QY, Chan GSH, Redmond SJ, Middleton PM, Steel E, Malouf P, et al. N. H. Lovell "classification of low systemic vascular resistance using photoplethysmogram and routine cardiovascular measurements" proc. Annu. Int Conf IEEE Eng Med Biol Soc. 2010:1930–3. Lee QY, Chan GSH, Redmond SJ, Middleton PM, Steel E, Malouf P, et al. N. H. Lovell "classification of low systemic vascular resistance using photoplethysmogram and routine cardiovascular measurements" proc. Annu. Int Conf IEEE Eng Med Biol Soc. 2010:1930–3.
4.
Zurück zum Zitat Zhang A. H. Wang "real-time detection system for photoelectric pulse signals" proc. IEEE Int Conf Bus ManagElectron Inform. 2011:498–501. Zhang A. H. Wang "real-time detection system for photoelectric pulse signals" proc. IEEE Int Conf Bus ManagElectron Inform. 2011:498–501.
5.
Zurück zum Zitat Doupis J, Papanas N, Cohen A, McFarlan L, Horton E. Pulse wave analysis by Applanation tonometry for the measurement of arterial stiffness. Open Cardiovasc Med J. 2016;10:188–95.CrossRef Doupis J, Papanas N, Cohen A, McFarlan L, Horton E. Pulse wave analysis by Applanation tonometry for the measurement of arterial stiffness. Open Cardiovasc Med J. 2016;10:188–95.CrossRef
6.
Zurück zum Zitat Yoo SK, Shin KY, Lee TB, Jin SO. New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics. SpringerPlus. 2013;2:406.CrossRef Yoo SK, Shin KY, Lee TB, Jin SO. New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics. SpringerPlus. 2013;2:406.CrossRef
7.
Zurück zum Zitat Renevey P, Vetter R, Krauss J, Celka P, Depeursinge Y. Wrist-located pulse detection using IR signals activity and nonlinear artifact cancellation. Proc Annu Int Conf IEEE Eng Med Biol Soc. 2001;3:3030–3. Renevey P, Vetter R, Krauss J, Celka P, Depeursinge Y. Wrist-located pulse detection using IR signals activity and nonlinear artifact cancellation. Proc Annu Int Conf IEEE Eng Med Biol Soc. 2001;3:3030–3.
8.
Zurück zum Zitat Kwak YH, Kim W, Park KB, Kim K, Seo S. Flexible heartbeat sensor for wearable device. Biosensors Bioelectron. 2017;94(15):250–5.CrossRef Kwak YH, Kim W, Park KB, Kim K, Seo S. Flexible heartbeat sensor for wearable device. Biosensors Bioelectron. 2017;94(15):250–5.CrossRef
9.
Zurück zum Zitat Aritomo M, Yonezawa Y. A wrist-mounted activity and pulse recording system. In Proc of the First Joint BMES/EMBS Conf. 1999;2:693.CrossRef Aritomo M, Yonezawa Y. A wrist-mounted activity and pulse recording system. In Proc of the First Joint BMES/EMBS Conf. 1999;2:693.CrossRef
10.
Zurück zum Zitat Rangaprakash D, Narayana Dutt D. Study of wrist pulse signals using time domain spatial features. Comput Electr Eng. 2015;45:100–7.CrossRef Rangaprakash D, Narayana Dutt D. Study of wrist pulse signals using time domain spatial features. Comput Electr Eng. 2015;45:100–7.CrossRef
11.
Zurück zum Zitat Hu C-S, Chung Y-F, Yeh C-C, Luo C-H. Temporal and spatial properties of arterial pulsation measurement using pressure sensor array. Evidence-Based Complementary Alternative Med. 2012;2012:1–9. Hu C-S, Chung Y-F, Yeh C-C, Luo C-H. Temporal and spatial properties of arterial pulsation measurement using pressure sensor array. Evidence-Based Complementary Alternative Med. 2012;2012:1–9.
12.
Zurück zum Zitat Joshi AB, Kalange AE, Bodas D, Gangal SA. Simulations of piezoelectric pressure sensor for radial artery pulse measurement. Mater Sci Eng B. 2010;168(1–3):250–3.CrossRef Joshi AB, Kalange AE, Bodas D, Gangal SA. Simulations of piezoelectric pressure sensor for radial artery pulse measurement. Mater Sci Eng B. 2010;168(1–3):250–3.CrossRef
13.
Zurück zum Zitat Selvaraj N, Shelley KH, Silverman DG, Stachenfeld N, Galante N, Florian JP, et al. A novel approach using time frequency analysis of pulse-oximeter data to detect progressive hypovolemia in spontaneously breathing healthy subjects. IEEE Trans Biomed Eng. 2011;58(8):2272–9.CrossRef Selvaraj N, Shelley KH, Silverman DG, Stachenfeld N, Galante N, Florian JP, et al. A novel approach using time frequency analysis of pulse-oximeter data to detect progressive hypovolemia in spontaneously breathing healthy subjects. IEEE Trans Biomed Eng. 2011;58(8):2272–9.CrossRef
14.
Zurück zum Zitat Wang P, Zuo W, Zhang D. A compound pressure signal acquisition system for multichannel wrist pulse signal analysis. IEEE Trans Instrum Meas. 2014;63(6):1556–65.CrossRef Wang P, Zuo W, Zhang D. A compound pressure signal acquisition system for multichannel wrist pulse signal analysis. IEEE Trans Instrum Meas. 2014;63(6):1556–65.CrossRef
15.
Zurück zum Zitat Zuo W, Wang P, Zhang D. Comparison of three different types of wrist pulse signals by their physical meanings and diagnosis performance. IEEE J Biomed Health Inform. 2016;20(1):119–27.CrossRef Zuo W, Wang P, Zhang D. Comparison of three different types of wrist pulse signals by their physical meanings and diagnosis performance. IEEE J Biomed Health Inform. 2016;20(1):119–27.CrossRef
16.
Zurück zum Zitat Wang P, Zuo W, Zhang H, Zhang D. "Design and implementation of a multi-channel pulse signal acquisition system" proc. IEEE Int Conf Biomed Eng Informat. 2012:1063–7. Wang P, Zuo W, Zhang H, Zhang D. "Design and implementation of a multi-channel pulse signal acquisition system" proc. IEEE Int Conf Biomed Eng Informat. 2012:1063–7.
17.
Zurück zum Zitat Wang D, Zhang D, Lu G. A novel multichannel wrist pulse system with different sensor arrays. IEEE Trans Instrum Meas. 2015;64(7):2020–34.CrossRef Wang D, Zhang D, Lu G. A novel multichannel wrist pulse system with different sensor arrays. IEEE Trans Instrum Meas. 2015;64(7):2020–34.CrossRef
18.
Zurück zum Zitat Mi X, Nakazawa F. A multipoint thin film polymer pressure/force sensor to visualize traditional medicine palpations. IEEE SENSORS 2014 Proc, Valencia. 2014:843–6. Mi X, Nakazawa F. A multipoint thin film polymer pressure/force sensor to visualize traditional medicine palpations. IEEE SENSORS 2014 Proc, Valencia. 2014:843–6.
19.
Zurück zum Zitat V. D. Lad Secrets of the Pulse Albuquerque NM USA:TheAyurvedic Press 1996. V. D. Lad Secrets of the Pulse Albuquerque NM USA:TheAyurvedic Press 1996.
20.
Zurück zum Zitat S. UpadhyayNadivijnana (Ancient pulse science).Chaukhambha Sanskrit Pratishthan Delhi 1986. S. UpadhyayNadivijnana (Ancient pulse science).Chaukhambha Sanskrit Pratishthan Delhi 1986.
21.
Zurück zum Zitat Hankey A. Establishing the scientific validity of tridosha part 1: Dosha ,Subdosha and DoshaPrakritis. Anc Sci Life. 2010;20(3):6–18. Hankey A. Establishing the scientific validity of tridosha part 1: Dosha ,Subdosha and DoshaPrakritis. Anc Sci Life. 2010;20(3):6–18.
22.
Zurück zum Zitat Joshi A, Kulkarni A, Chandran S, Jayaraman VK, Kulkarni BD. "NadiTarangini: a pulse based diagnostic system," 2007 29th annual international conference of the IEEE engineering in medicine and biology society. Lyon. 2007:2207–10. Joshi A, Kulkarni A, Chandran S, Jayaraman VK, Kulkarni BD. "NadiTarangini: a pulse based diagnostic system," 2007 29th annual international conference of the IEEE engineering in medicine and biology society. Lyon. 2007:2207–10.
23.
Zurück zum Zitat Abhinav MS, Kumar M, Anand S, Salhan A, Santhosh J. “Nadiyantra: a robust system design to capture the signals from the radial artery for non-invasive diagnosis,” in bioinformatics and biomedical engineering, 2008. ICBBE 2008. 2nd Int Conf. 2008:1387–90. Abhinav MS, Kumar M, Anand S, Salhan A, Santhosh J. “Nadiyantra: a robust system design to capture the signals from the radial artery for non-invasive diagnosis,” in bioinformatics and biomedical engineering, 2008. ICBBE 2008. 2nd Int Conf. 2008:1387–90.
24.
Zurück zum Zitat Selvan T, Begum M. Nadiaridhal: A pulse based automated diagnostic system, in Electronics Computer Technology (ICECT). 3rd Int Conf. 2011;1:305–8. Selvan T, Begum M. Nadiaridhal: A pulse based automated diagnostic system, in Electronics Computer Technology (ICECT). 3rd Int Conf. 2011;1:305–8.
25.
Zurück zum Zitat Begum M, Poonguzhali R. “Noikanippaan: Nadi diagnosing system,” in recent trends in information technology (ICRTIT). Int Conf. 2011:1049–54. Begum M, Poonguzhali R. “Noikanippaan: Nadi diagnosing system,” in recent trends in information technology (ICRTIT). Int Conf. 2011:1049–54.
26.
Zurück zum Zitat Kalange AE, Mahale BP, Aghav ST, Gangal SA. Nadiparikshanyantra and analysis of radial pulse, in physics and Technology of Sensors (ISPTS). 1st Int Symposium. 2012;2012:165–8. Kalange AE, Mahale BP, Aghav ST, Gangal SA. Nadiparikshanyantra and analysis of radial pulse, in physics and Technology of Sensors (ISPTS). 1st Int Symposium. 2012;2012:165–8.
27.
Zurück zum Zitat N. Arunkumar K. M. M. Sirajudeen. Approximate entropy based ayurvedic pulse diagnosis for diabetics—A case study" Proc. IEEE Int Conf Trendz Inf Sci Comp. 133–135, 2011. N. Arunkumar K. M. M. Sirajudeen. Approximate entropy based ayurvedic pulse diagnosis for diabetics—A case study" Proc. IEEE Int Conf Trendz Inf Sci Comp. 133–135, 2011.
Metadaten
Titel
Experimental investigation on the suitability of flexible pressure sensor for wrist pulse measurement
verfasst von
Sukesh Rao M.
Rathnamala Rao
Publikationsdatum
20.09.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Health and Technology / Ausgabe 2/2019
Print ISSN: 2190-7188
Elektronische ISSN: 2190-7196
DOI
https://doi.org/10.1007/s12553-018-0264-0

Weitere Artikel der Ausgabe 2/2019

Health and Technology 2/2019 Zur Ausgabe