Skip to main content

2008 | OriginalPaper | Buchkapitel

31. Experimental Methods in Biological Tissue Testing

verfasst von : Stephen M. Belkoff, Prof., Roger C. Haut, Prof.

Erschienen in: Springer Handbook of Experimental Solid Mechanics

Verlag: Springer US

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The current chapter on testing biological tissue is intended to serve as an introduction to the field of experimental biomechanics. The field is broad, encompassing the investigation of the material behavior of plant and animal tissue. We have chosen to focus on experimental methods used to test human tissue, primarily the connective tissues ligament, tendon, articular cartilage, bone, and skin. For each of these tissues, the chapter presents a brief overview of the structure–function relationship of the tissue and then discusses some of the common tests conducted on the tissue to obtain various material and mechanical properties of interest. The chapter also highlights some of the stark differences in testing biological tissues compared with engineering materials with which the reader may be more familiar.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
31.1.
Zurück zum Zitat A. Race, A.A. Amis: The mechanical properties of the two bundles of the human posterior cruciate ligament, J. Biomech. 27, 13–24 (1994)CrossRef A. Race, A.A. Amis: The mechanical properties of the two bundles of the human posterior cruciate ligament, J. Biomech. 27, 13–24 (1994)CrossRef
31.2.
Zurück zum Zitat R.C. Haut, A.C. Powlison: The effects of test environment and cyclic stretching on the failure properties of human patellar tendons, J. Orthop. Res. 8, 532–540 (1990)CrossRef R.C. Haut, A.C. Powlison: The effects of test environment and cyclic stretching on the failure properties of human patellar tendons, J. Orthop. Res. 8, 532–540 (1990)CrossRef
31.3.
Zurück zum Zitat D.L. Butler, M.D. Kay, D.C. Stouffer: Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments, J. Biomech. 19, 425–432 (1986)CrossRef D.L. Butler, M.D. Kay, D.C. Stouffer: Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments, J. Biomech. 19, 425–432 (1986)CrossRef
31.4.
Zurück zum Zitat D.G. Ellis: Cross-sectional area measurements for tendon specimens: a comparison of several methods, J. Biomech. 2, 175–186 (1969)CrossRef D.G. Ellis: Cross-sectional area measurements for tendon specimens: a comparison of several methods, J. Biomech. 2, 175–186 (1969)CrossRef
31.5.
Zurück zum Zitat D.L. Buttler, D.A. Hulse, M.D. Kay, E.S. Grood, P.K. Shires, R. DʼAmbrosia, H. Shoji: Biomechanics of cranial cruciate ligament reconstruction in the dog. II. Mechanical properties, Vet. Surg. 12, 113–118 (1983)CrossRef D.L. Buttler, D.A. Hulse, M.D. Kay, E.S. Grood, P.K. Shires, R. DʼAmbrosia, H. Shoji: Biomechanics of cranial cruciate ligament reconstruction in the dog. II. Mechanical properties, Vet. Surg. 12, 113–118 (1983)CrossRef
31.6.
Zurück zum Zitat B.N. Gupta, K.N. Subramanian, W.O. Brinker, A.N. Gupta: Tensile strength of canine cranial cruciate ligaments, Am. J. Vet. Res. 32, 183–190 (1971) B.N. Gupta, K.N. Subramanian, W.O. Brinker, A.N. Gupta: Tensile strength of canine cranial cruciate ligaments, Am. J. Vet. Res. 32, 183–190 (1971)
31.7.
Zurück zum Zitat F. Iaconis, R. Steindler, G. Marinozzi: Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method, J. Biomech. 20, 1003–1010 (1987)CrossRef F. Iaconis, R. Steindler, G. Marinozzi: Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method, J. Biomech. 20, 1003–1010 (1987)CrossRef
31.8.
Zurück zum Zitat T.Q. Lee, S.L. Woo: A new method for determining cross-sectional shape and area of soft tissues, J. Biomech. Eng. 110, 110–114 (1988)CrossRef T.Q. Lee, S.L. Woo: A new method for determining cross-sectional shape and area of soft tissues, J. Biomech. Eng. 110, 110–114 (1988)CrossRef
31.9.
Zurück zum Zitat S.L. Woo, M.I. Danto, K.J. Ohland, T.Q. Lee, P.O. Newton: The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods, J. Biomech. Eng. 112, 426–431 (1990)CrossRef S.L. Woo, M.I. Danto, K.J. Ohland, T.Q. Lee, P.O. Newton: The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods, J. Biomech. Eng. 112, 426–431 (1990)CrossRef
31.10.
Zurück zum Zitat D.K. Moon, S.D. Abramowitch, S.L. Woo: The development and validation of a charge-coupled device laser reflectance system to measure the complex cross-sectional shape and area of soft tissues, J. Biomech. 39, 3071–3075 (2006)CrossRef D.K. Moon, S.D. Abramowitch, S.L. Woo: The development and validation of a charge-coupled device laser reflectance system to measure the complex cross-sectional shape and area of soft tissues, J. Biomech. 39, 3071–3075 (2006)CrossRef
31.11.
Zurück zum Zitat D.L. Butler: Kappa delta award paper. Anterior cruciate ligament: its normal response and replacement, J. Orthop. Res. 7, 910–921 (1989)CrossRef D.L. Butler: Kappa delta award paper. Anterior cruciate ligament: its normal response and replacement, J. Orthop. Res. 7, 910–921 (1989)CrossRef
31.12.
Zurück zum Zitat D.L. Bartel, J.L. Marshall, R.A. Schieck, J.B. Wang: Surgical repositioning of the medial collateral ligament. An anatomical and mechanical analysis, J. Bone Joint Surg. Am. 59, 107–116 (1977) D.L. Bartel, J.L. Marshall, R.A. Schieck, J.B. Wang: Surgical repositioning of the medial collateral ligament. An anatomical and mechanical analysis, J. Bone Joint Surg. Am. 59, 107–116 (1977)
31.13.
Zurück zum Zitat C.J. Wang, P.S. Walker: The effects of flexion and rotation on the length patterns of the ligaments of the knee, J. Biomech. 6, 587–596 (1973)CrossRef C.J. Wang, P.S. Walker: The effects of flexion and rotation on the length patterns of the ligaments of the knee, J. Biomech. 6, 587–596 (1973)CrossRef
31.14.
Zurück zum Zitat L.F. Warren, J.L. Marshall, F. Girgis: The prime static stabilizer of the medical side of the knee, J. Bone Joint Surg. 56A, 665–674 (1974) L.F. Warren, J.L. Marshall, F. Girgis: The prime static stabilizer of the medical side of the knee, J. Bone Joint Surg. 56A, 665–674 (1974)
31.15.
Zurück zum Zitat D.L. Butler, M.Y. Sheh, D.C. Stouffer, V.A. Samaranayake, M.S. Levy: Surface strain variation in human patellar tendon and knee cruciate ligaments, J. Biomech. Eng. 112, 38–45 (1990)CrossRef D.L. Butler, M.Y. Sheh, D.C. Stouffer, V.A. Samaranayake, M.S. Levy: Surface strain variation in human patellar tendon and knee cruciate ligaments, J. Biomech. Eng. 112, 38–45 (1990)CrossRef
31.16.
Zurück zum Zitat Y. Cao, J.P. Vacanti, X. Ma, K.T. Paige, J. Upton, Z. Chowanski, B. Schloo, R. Langer, C.A. Vacanti: Generation of neo-tendon using synthetic polymers seeded with tenocytes, Transplant. Proc. 26, 3390–3392 (1994) Y. Cao, J.P. Vacanti, X. Ma, K.T. Paige, J. Upton, Z. Chowanski, B. Schloo, R. Langer, C.A. Vacanti: Generation of neo-tendon using synthetic polymers seeded with tenocytes, Transplant. Proc. 26, 3390–3392 (1994)
31.17.
Zurück zum Zitat C.D. Harner, J.W. Xerogeanes, G.A. Livesay, G.J. Carlin, B.A. Smith, T. Kusayama, S. Kashiwaguchi, S.L. Woo: The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation, Am. J. Sports Med. 23, 736–745 (1995)CrossRef C.D. Harner, J.W. Xerogeanes, G.A. Livesay, G.J. Carlin, B.A. Smith, T. Kusayama, S. Kashiwaguchi, S.L. Woo: The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation, Am. J. Sports Med. 23, 736–745 (1995)CrossRef
31.18.
Zurück zum Zitat S.U. Scheffler, T.D. Clineff, C.D. Papageorgiou, R.E. Debski, C.B. Ma, S.L.Y. Woo: Structure and function of the healing medial collateral ligament in a goat model, Ann. Biomed. Eng. 29, 173–180 (2001)CrossRef S.U. Scheffler, T.D. Clineff, C.D. Papageorgiou, R.E. Debski, C.B. Ma, S.L.Y. Woo: Structure and function of the healing medial collateral ligament in a goat model, Ann. Biomed. Eng. 29, 173–180 (2001)CrossRef
31.19.
Zurück zum Zitat T.C. Lam, C.B. Frank, N.G. Shrive: Calibration characteristics of a video dimension analyser (VDA) system, J. Biomech. 25, 1227–1231 (1992)CrossRef T.C. Lam, C.B. Frank, N.G. Shrive: Calibration characteristics of a video dimension analyser (VDA) system, J. Biomech. 25, 1227–1231 (1992)CrossRef
31.20.
Zurück zum Zitat W.P. Smutz, M. Drexler, L.J. Berglund, E. Growney, K.N. An: Accuracy of a video strain measurement system, J. Biomech. 29, 813–817 (1996)CrossRef W.P. Smutz, M. Drexler, L.J. Berglund, E. Growney, K.N. An: Accuracy of a video strain measurement system, J. Biomech. 29, 813–817 (1996)CrossRef
31.21.
Zurück zum Zitat S.L.Y. Woo: Mechanical properties of tendons and ligaments. I. Quasi-static and nonlinear viscoelastic properties, Biorheology 19, 385–396 (1982) S.L.Y. Woo: Mechanical properties of tendons and ligaments. I. Quasi-static and nonlinear viscoelastic properties, Biorheology 19, 385–396 (1982)
31.22.
Zurück zum Zitat N.A. Sharkey, T.S. Smith, D.C. Lundmark: Freeze clamping musculo-tendinous junctions for in vitro simulation of joint mechanics, J. Biomech. 28, 631–635 (1995)CrossRef N.A. Sharkey, T.S. Smith, D.C. Lundmark: Freeze clamping musculo-tendinous junctions for in vitro simulation of joint mechanics, J. Biomech. 28, 631–635 (1995)CrossRef
31.23.
Zurück zum Zitat T.L.H. Donahue, C. Gregersen, M.L. Hull, S.M. Howell: Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons, J. Biomech. Eng. 123, 162–169 (2001)CrossRef T.L.H. Donahue, C. Gregersen, M.L. Hull, S.M. Howell: Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons, J. Biomech. Eng. 123, 162–169 (2001)CrossRef
31.24.
Zurück zum Zitat R.T. Burks, R.C. Haut, R.L. Lancaster: Biomechanical and histological observations of the dog patellar tendon after removal of its central one-third, Am. J. Sports Med. 18, 146–153 (1990)CrossRef R.T. Burks, R.C. Haut, R.L. Lancaster: Biomechanical and histological observations of the dog patellar tendon after removal of its central one-third, Am. J. Sports Med. 18, 146–153 (1990)CrossRef
31.25.
Zurück zum Zitat Y.C.B. Fung: Biorheology of soft tissues, Biorheology 10, 139–155 (1973) Y.C.B. Fung: Biorheology of soft tissues, Biorheology 10, 139–155 (1973)
31.26.
Zurück zum Zitat J.A. Hannafin, S.P. Arnoczky, A. Hoonjan, P.A. Torzilli: Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: an in vitro study, J. Orthop. Res. 13, 907–914 (1995)CrossRef J.A. Hannafin, S.P. Arnoczky, A. Hoonjan, P.A. Torzilli: Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: an in vitro study, J. Orthop. Res. 13, 907–914 (1995)CrossRef
31.27.
Zurück zum Zitat A. Sverdlik, Y. Lanir: Time-dependent mechanical behavior of sheep digital tendons, including the effects of preconditioning, J. Biomech. Eng. 124, 78–84 (2002)CrossRef A. Sverdlik, Y. Lanir: Time-dependent mechanical behavior of sheep digital tendons, including the effects of preconditioning, J. Biomech. Eng. 124, 78–84 (2002)CrossRef
31.28.
Zurück zum Zitat Y.C. Fung: Biomechanics: Mechanical Properties of Living Tissues (Springer-Verlag, New York 1993) Y.C. Fung: Biomechanics: Mechanical Properties of Living Tissues (Springer-Verlag, New York 1993)
31.29.
Zurück zum Zitat S.L.Y. Woo, T.Q. Lee, M.A. Gomez, S. Sato, F.P. Field: Temperature dependent behavior of the canine medial collateral ligament, J. Biomech. Eng. 109, 68–71 (1987)CrossRef S.L.Y. Woo, T.Q. Lee, M.A. Gomez, S. Sato, F.P. Field: Temperature dependent behavior of the canine medial collateral ligament, J. Biomech. Eng. 109, 68–71 (1987)CrossRef
31.30.
Zurück zum Zitat D. Chimich, N. Shrive, C. Frank, L. Marchuk, R. Bray: Water content alters viscoelastic behaviour of the normal adolescent rabbit medial collateral ligament, J. Biomech. 25, 831–837 (1992)CrossRef D. Chimich, N. Shrive, C. Frank, L. Marchuk, R. Bray: Water content alters viscoelastic behaviour of the normal adolescent rabbit medial collateral ligament, J. Biomech. 25, 831–837 (1992)CrossRef
31.31.
Zurück zum Zitat T.L. Haut, R.C. Haut: The state of tissue hydration determines the strain-rate-sensitive stiffness of human patellar tendon, J. Biomech. 30, 79–81 (1997)CrossRef T.L. Haut, R.C. Haut: The state of tissue hydration determines the strain-rate-sensitive stiffness of human patellar tendon, J. Biomech. 30, 79–81 (1997)CrossRef
31.32.
Zurück zum Zitat J.J. Crisco, D.C. Moore, R.D. McGovern: Strain-rate sensitivity of the rabbit MCL diminishes at traumatic loading rates, J. Biomech. 35, 1379–1385 (2002)CrossRef J.J. Crisco, D.C. Moore, R.D. McGovern: Strain-rate sensitivity of the rabbit MCL diminishes at traumatic loading rates, J. Biomech. 35, 1379–1385 (2002)CrossRef
31.33.
Zurück zum Zitat Y.C. Fung: Stress-strain-history relations of soft tissues in simple elongation. In: Biomechanics: Its Foundations and Objectives, ed. by Y.C. Fung, N. Perrone, M. Anliker (Prentice-Hall, Englewood Cliffs 1972) Y.C. Fung: Stress-strain-history relations of soft tissues in simple elongation. In: Biomechanics: Its Foundations and Objectives, ed. by Y.C. Fung, N. Perrone, M. Anliker (Prentice-Hall, Englewood Cliffs 1972)
31.34.
Zurück zum Zitat T.S. Atkinson, R.C. Haut, N.J. Altiero: A poroelastic model that predicts some phenomenological responses of ligaments and tendons, J. Biomech. Eng. 119, 400–405 (1997)CrossRef T.S. Atkinson, R.C. Haut, N.J. Altiero: A poroelastic model that predicts some phenomenological responses of ligaments and tendons, J. Biomech. Eng. 119, 400–405 (1997)CrossRef
31.35.
Zurück zum Zitat F.R. Noyes, J.L. DeLucas, P.J. Torvik: Biomechanics of anterior cruciate ligament failure: an analysis of strain-rate sensitivity and mechanisms of failure in primates, J. Bone Joint Surg. 56A, 236–253 (1974) F.R. Noyes, J.L. DeLucas, P.J. Torvik: Biomechanics of anterior cruciate ligament failure: an analysis of strain-rate sensitivity and mechanisms of failure in primates, J. Bone Joint Surg. 56A, 236–253 (1974)
31.36.
Zurück zum Zitat R.D. Crowninshield, M.H. Pope: The strength and failure characteristics of rat medial collateral ligaments, J. Trauma 16, 99–105 (1976)CrossRef R.D. Crowninshield, M.H. Pope: The strength and failure characteristics of rat medial collateral ligaments, J. Trauma 16, 99–105 (1976)CrossRef
31.37.
Zurück zum Zitat S.L.Y. Woo, R.E. Debski, J.D. Withrow, M.A. Januashek: Biomechanics of knee ligaments, AJSM 27(4), 533–543 (1999) S.L.Y. Woo, R.E. Debski, J.D. Withrow, M.A. Januashek: Biomechanics of knee ligaments, AJSM 27(4), 533–543 (1999)
31.38.
Zurück zum Zitat S.L.Y. Woo, M.A. Gomez, W.H. Akeson: The time and history-dependent viscoelastic properties of the canine medical collateral ligament, J. Biomech. Eng. 103, 293–298 (1981)CrossRef S.L.Y. Woo, M.A. Gomez, W.H. Akeson: The time and history-dependent viscoelastic properties of the canine medical collateral ligament, J. Biomech. Eng. 103, 293–298 (1981)CrossRef
31.39.
Zurück zum Zitat S.D. Abramowitch, S.L. Woo: An improved method to analyze the stress relaxation of ligaments following a finite ramp time based on the quasi-linear viscoelastic theory, J. Biomech. Eng. 126, 92–97 (2004)CrossRef S.D. Abramowitch, S.L. Woo: An improved method to analyze the stress relaxation of ligaments following a finite ramp time based on the quasi-linear viscoelastic theory, J. Biomech. Eng. 126, 92–97 (2004)CrossRef
31.40.
Zurück zum Zitat R.C. Haut, R.W. Little: A constitutive equation for collagen fibers, J. Biomech. 5, 423–430 (1972)CrossRef R.C. Haut, R.W. Little: A constitutive equation for collagen fibers, J. Biomech. 5, 423–430 (1972)CrossRef
31.41.
Zurück zum Zitat G.M. Thornton, A. Oliynyk, C.B. Frank, N.G. Shrive: Ligament creep cannot be predicted from stress relaxation at low stress: a biomechanical study of the rabbit medial collateral ligament, J. Orthop. Res. 15, 652–656 (1997)CrossRef G.M. Thornton, A. Oliynyk, C.B. Frank, N.G. Shrive: Ligament creep cannot be predicted from stress relaxation at low stress: a biomechanical study of the rabbit medial collateral ligament, J. Orthop. Res. 15, 652–656 (1997)CrossRef
31.42.
Zurück zum Zitat R.V. Hingorani, P.P. Provenzano, R.S. Lakes, A. Escarcega, R. Vanderby Jr.: Nonlinear viscoelasticity in rabbit medial collateral ligament, Ann. Biomed. Eng. 32, 306–312 (2004)CrossRef R.V. Hingorani, P.P. Provenzano, R.S. Lakes, A. Escarcega, R. Vanderby Jr.: Nonlinear viscoelasticity in rabbit medial collateral ligament, Ann. Biomed. Eng. 32, 306–312 (2004)CrossRef
31.43.
Zurück zum Zitat W. Wilson, C.C. van Donkelaar, B. van Rietbergen, K. Ito, R. Huiskes: Stresses in the local collagen network of articular cartilage: a poroviscoelastic fibril-reinforced finite element study, J. Biomech. 37, 357–366 (2004)CrossRef W. Wilson, C.C. van Donkelaar, B. van Rietbergen, K. Ito, R. Huiskes: Stresses in the local collagen network of articular cartilage: a poroviscoelastic fibril-reinforced finite element study, J. Biomech. 37, 357–366 (2004)CrossRef
31.44.
Zurück zum Zitat P. Bullough, J. Goodfellow: The significance of the fine structure of articular cartilage, J. Bone Joint Surg. Br. 50, 852–857 (1968) P. Bullough, J. Goodfellow: The significance of the fine structure of articular cartilage, J. Bone Joint Surg. Br. 50, 852–857 (1968)
31.45.
Zurück zum Zitat A. Benninghoff: Form und Bau der Gelenkknorpel in ihren Beziehungen zur Funktion. II., Zeitschrift für Zellforschung und Mikroskopische Anatomie 2, 793 (1925)CrossRef A. Benninghoff: Form und Bau der Gelenkknorpel in ihren Beziehungen zur Funktion. II., Zeitschrift für Zellforschung und Mikroskopische Anatomie 2, 793 (1925)CrossRef
31.46.
Zurück zum Zitat S. Akizuki, V.C. Mow, F. Muller, J.C. Pita, D.S. Howell, D.H. Manicourt: Tensile properties of human knee joint cartilage: I. influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus, J. Orthop. Res. 4, 379–392 (1986)CrossRef S. Akizuki, V.C. Mow, F. Muller, J.C. Pita, D.S. Howell, D.H. Manicourt: Tensile properties of human knee joint cartilage: I. influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus, J. Orthop. Res. 4, 379–392 (1986)CrossRef
31.47.
Zurück zum Zitat M. Charlebois, M.D. McKee, M.D. Buschmann: Nonlinear tensile properties of bovine articular cartilage and their variation with age and depth, J. Biomech. Eng. 126, 129–137 (2004)CrossRef M. Charlebois, M.D. McKee, M.D. Buschmann: Nonlinear tensile properties of bovine articular cartilage and their variation with age and depth, J. Biomech. Eng. 126, 129–137 (2004)CrossRef
31.48.
Zurück zum Zitat S.L.Y. Woo, P. Lubock, M.A. Gomez, G.F. Jemmott, S.C. Kuei, W.H. Akeson: Large deformation nonhomogeneous and directional properties of articular cartilage in uniaxial tension, J. Biomech. 12, 437–446 (1979)CrossRef S.L.Y. Woo, P. Lubock, M.A. Gomez, G.F. Jemmott, S.C. Kuei, W.H. Akeson: Large deformation nonhomogeneous and directional properties of articular cartilage in uniaxial tension, J. Biomech. 12, 437–446 (1979)CrossRef
31.49.
Zurück zum Zitat V. Roth, V.C. Mow: The intrinsic tensile behavior of the matrix of bovine articular cartilage and its variation with age, J. Bone Joint Surg. Am. 62, 1102–1117 (1980) V. Roth, V.C. Mow: The intrinsic tensile behavior of the matrix of bovine articular cartilage and its variation with age, J. Bone Joint Surg. Am. 62, 1102–1117 (1980)
31.50.
Zurück zum Zitat S.L.Y. Woo, P. Lubock, M.A. Gomez, G.F. Jemmott, S.C. Kuei, W.H. Akeson: Large deformation nonhomogeneous and directional properties of articular cartilage in uniaxial tension, J. Biomech. 12, 437–446 (1979)CrossRef S.L.Y. Woo, P. Lubock, M.A. Gomez, G.F. Jemmott, S.C. Kuei, W.H. Akeson: Large deformation nonhomogeneous and directional properties of articular cartilage in uniaxial tension, J. Biomech. 12, 437–446 (1979)CrossRef
31.51.
Zurück zum Zitat N.O. Chahine, C.C.B. Wang, C.T. Hung, G.A. Ateshian: Anisotropic strain-dependent material properties of bovine articular cartilage in the transitional range from tension to compression, J. Biomech. 37, 1251–1261 (2004)CrossRef N.O. Chahine, C.C.B. Wang, C.T. Hung, G.A. Ateshian: Anisotropic strain-dependent material properties of bovine articular cartilage in the transitional range from tension to compression, J. Biomech. 37, 1251–1261 (2004)CrossRef
31.52.
Zurück zum Zitat A.K. Williamson, A.C. Chen, K. Masuda, R.L. Sah, E.J.M.A. Thonar: Tensile mechanical properties of bovine articular cartilage: variations with growth and relationships to collagen network components, J. Orthop. Res. 21, 872–880 (2003)CrossRef A.K. Williamson, A.C. Chen, K. Masuda, R.L. Sah, E.J.M.A. Thonar: Tensile mechanical properties of bovine articular cartilage: variations with growth and relationships to collagen network components, J. Orthop. Res. 21, 872–880 (2003)CrossRef
31.53.
Zurück zum Zitat V.C. Mow, S.C. Kuei, W.M. Lai, C.G. Armstrong: Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments, J. Biomech. Eng. 102, 73–84 (1980)CrossRef V.C. Mow, S.C. Kuei, W.M. Lai, C.G. Armstrong: Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments, J. Biomech. Eng. 102, 73–84 (1980)CrossRef
31.54.
Zurück zum Zitat T.D. Brown, R.J. Singerman: Experimental determination of the linear biphasic constitutive coefficients of human fetal proximal femoral chondroepiphysis, J. Biomech. 19, 597–605 (1986)CrossRef T.D. Brown, R.J. Singerman: Experimental determination of the linear biphasic constitutive coefficients of human fetal proximal femoral chondroepiphysis, J. Biomech. 19, 597–605 (1986)CrossRef
31.55.
Zurück zum Zitat C.G. Armstrong, W.M. Lai, V.C. Mow: An analysis of the unconfined compression of articular cartilage, J. Biomech. Eng. 106, 165–173 (1984)CrossRef C.G. Armstrong, W.M. Lai, V.C. Mow: An analysis of the unconfined compression of articular cartilage, J. Biomech. Eng. 106, 165–173 (1984)CrossRef
31.56.
Zurück zum Zitat V.C. Mow, W.C. Hayes: Basic Orthopaedic Biomechanics (Raven, New York 1991) V.C. Mow, W.C. Hayes: Basic Orthopaedic Biomechanics (Raven, New York 1991)
31.57.
Zurück zum Zitat J.J. Garcia, N.J. Altiero, R.C. Haut: Estimation of in situ elastic properties of biphasic cartilage based on a transversely isotropic hypo-elastic model, J. Biomech. Eng. 122, 1–8 (2000)CrossRef J.J. Garcia, N.J. Altiero, R.C. Haut: Estimation of in situ elastic properties of biphasic cartilage based on a transversely isotropic hypo-elastic model, J. Biomech. Eng. 122, 1–8 (2000)CrossRef
31.58.
Zurück zum Zitat P.M. Bursac, T.W. Obitz, S.R. Eisenberg, D. Stamenovic: Confined and unconfined stress relaxation of cartilage: appropriateness of a transversely isotropic analysis, J. Biomech. 32, 1125–1130 (1999)CrossRef P.M. Bursac, T.W. Obitz, S.R. Eisenberg, D. Stamenovic: Confined and unconfined stress relaxation of cartilage: appropriateness of a transversely isotropic analysis, J. Biomech. 32, 1125–1130 (1999)CrossRef
31.59.
Zurück zum Zitat M.A. Soltz, G.A. Ateshian: A conewise linear elasticity mixture model for the analysis of tension-compression nonlinearity in articular cartilage, J. Biomech. Eng. 122, 576–586 (2000)CrossRef M.A. Soltz, G.A. Ateshian: A conewise linear elasticity mixture model for the analysis of tension-compression nonlinearity in articular cartilage, J. Biomech. Eng. 122, 576–586 (2000)CrossRef
31.60.
Zurück zum Zitat L.P. Li, J. Soulhat, M.D. Buschmann, A. Shirazi-Adl: Nonlinear analysis of cartilage in unconfined ramp compression using a fibril reinforced poroelastic model, Clin. Biomech. 14, 673–682 (1999)CrossRef L.P. Li, J. Soulhat, M.D. Buschmann, A. Shirazi-Adl: Nonlinear analysis of cartilage in unconfined ramp compression using a fibril reinforced poroelastic model, Clin. Biomech. 14, 673–682 (1999)CrossRef
31.61.
Zurück zum Zitat R.K. Korhonen, M.S. Laasanen, J. Toyras, J. Rieppo, J. Hirvonen, H.J. Helminen, J.S. Jurvelin: Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation, J. Biomech. 35, 903–909 (2002)CrossRef R.K. Korhonen, M.S. Laasanen, J. Toyras, J. Rieppo, J. Hirvonen, H.J. Helminen, J.S. Jurvelin: Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation, J. Biomech. 35, 903–909 (2002)CrossRef
31.62.
Zurück zum Zitat L.P. Li, R.K. Korhonen, J. Iivarinen, J.S. Jurvelin, W. Herzog: Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage, Med. Eng. Phys. 30(2), 182–189 (2007)CrossRef L.P. Li, R.K. Korhonen, J. Iivarinen, J.S. Jurvelin, W. Herzog: Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage, Med. Eng. Phys. 30(2), 182–189 (2007)CrossRef
31.63.
Zurück zum Zitat R.C. Haut, T.M. Ide, C.E. De Camp: Mechanical responses of the rabbit patello-femoral joint to blunt impact, J. Biomech. Eng. 117, 402–408 (1995)CrossRef R.C. Haut, T.M. Ide, C.E. De Camp: Mechanical responses of the rabbit patello-femoral joint to blunt impact, J. Biomech. Eng. 117, 402–408 (1995)CrossRef
31.64.
Zurück zum Zitat W.C. Hayes, L.M. Keer, G. Herrmann, L.F. Mockros: A mathematical analysis for indentation tests of articular cartilage, J. Biomech. 5, 541–551 (1972)CrossRef W.C. Hayes, L.M. Keer, G. Herrmann, L.F. Mockros: A mathematical analysis for indentation tests of articular cartilage, J. Biomech. 5, 541–551 (1972)CrossRef
31.65.
Zurück zum Zitat M. Zhang, Y.P. Zheng, A.F.T. Mak: Estimating the effective youngʼs modulus of soft tissues from indentation tests–nonlinear finite element analysis of effects of friction and large deformation, Med. Eng. Phys. 19, 512–517 (1997)CrossRef M. Zhang, Y.P. Zheng, A.F.T. Mak: Estimating the effective youngʼs modulus of soft tissues from indentation tests–nonlinear finite element analysis of effects of friction and large deformation, Med. Eng. Phys. 19, 512–517 (1997)CrossRef
31.66.
Zurück zum Zitat J.R. Parsons, J. Black: The viscoelastic shear behavior of normal rabbit articular cartilage, J. Biomech. 10, 21–29 (1977)CrossRef J.R. Parsons, J. Black: The viscoelastic shear behavior of normal rabbit articular cartilage, J. Biomech. 10, 21–29 (1977)CrossRef
31.67.
Zurück zum Zitat H. Jin, J.L. Lewis: Determination of poissonʼs ratio of articular cartilage by indentation using different-sized indenters, J. Biomech. Eng. 126, 138–145 (2004)CrossRef H. Jin, J.L. Lewis: Determination of poissonʼs ratio of articular cartilage by indentation using different-sized indenters, J. Biomech. Eng. 126, 138–145 (2004)CrossRef
31.68.
Zurück zum Zitat J. Jurvelin, I. Kiviranta, J. Arokoski, M. Tammi, H.J. Helminen: Indentation study of the biochemical properties of articular cartilage in the canine knee, Eng. Med. 16, 15–22 (1987)CrossRef J. Jurvelin, I. Kiviranta, J. Arokoski, M. Tammi, H.J. Helminen: Indentation study of the biochemical properties of articular cartilage in the canine knee, Eng. Med. 16, 15–22 (1987)CrossRef
31.69.
Zurück zum Zitat D.H. Hoch, A.J. Grodzinsky, T.J. Koob, M.L. Albert, D.R. Eyre: Early changes in material properties of rabbit articular cartilage after meniscectomy, J. Orthop. Res. 1, 4–12 (1983)CrossRef D.H. Hoch, A.J. Grodzinsky, T.J. Koob, M.L. Albert, D.R. Eyre: Early changes in material properties of rabbit articular cartilage after meniscectomy, J. Orthop. Res. 1, 4–12 (1983)CrossRef
31.70.
Zurück zum Zitat V.C. Mow, M.C. Gibbs, W.M. Lai, W.B. Zhu, K.A. Athanasiou: Biphasic indentation of articular cartilage – II. A numerical algorithm and an experimental study, J. Biomech. 22, 853–861 (1989)CrossRef V.C. Mow, M.C. Gibbs, W.M. Lai, W.B. Zhu, K.A. Athanasiou: Biphasic indentation of articular cartilage – II. A numerical algorithm and an experimental study, J. Biomech. 22, 853–861 (1989)CrossRef
31.71.
Zurück zum Zitat J.S. Jurvelin, T. Rasanen, P. Kolmonen, T. Lyyra: Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular cartilage thickness, J. Biomech. 28, 231–235 (1995)CrossRef J.S. Jurvelin, T. Rasanen, P. Kolmonen, T. Lyyra: Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular cartilage thickness, J. Biomech. 28, 231–235 (1995)CrossRef
31.72.
Zurück zum Zitat J.K.F. Suh, I. Youn, F.H. Fu: An in situ calibration of an ultrasound transducer: a potential application for an ultrasonic indentation test of articular cartilage, J. Biomech. 34, 1347–1353 (2001)CrossRef J.K.F. Suh, I. Youn, F.H. Fu: An in situ calibration of an ultrasound transducer: a potential application for an ultrasonic indentation test of articular cartilage, J. Biomech. 34, 1347–1353 (2001)CrossRef
31.73.
Zurück zum Zitat J. Toyras, T. Lyyra-Laitinen, M. Niinimaki, R. Lindgren, M.T. Nieminen, I. Kiviranta, J.S. Jurvelin: Estimation of the youngʼs modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thickness, J. Biomech. 34, 251–256 (2001)CrossRef J. Toyras, T. Lyyra-Laitinen, M. Niinimaki, R. Lindgren, M.T. Nieminen, I. Kiviranta, J.S. Jurvelin: Estimation of the youngʼs modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thickness, J. Biomech. 34, 251–256 (2001)CrossRef
31.74.
Zurück zum Zitat A.F. Mak, W.M. Lai, V.C. Mow: Biphasic indentation of articular cartilage – I. theoretical analysis, J. Biomech. 20, 703–714 (1987)CrossRef A.F. Mak, W.M. Lai, V.C. Mow: Biphasic indentation of articular cartilage – I. theoretical analysis, J. Biomech. 20, 703–714 (1987)CrossRef
31.75.
Zurück zum Zitat K.A. Athanasiou, A. Agarwal, F.J. Dzida: Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilage, J. Orthop. Res. 12, 340–349 (1994)CrossRef K.A. Athanasiou, A. Agarwal, F.J. Dzida: Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilage, J. Orthop. Res. 12, 340–349 (1994)CrossRef
31.76.
Zurück zum Zitat M.L. Roemhildt, K.M. Coughlin, G.D. Peura, B.C. Fleming, B.D. Beynnon: Material properties of articular cartilage in the rabbit tibial plateau, J. Biomech. 39, 2331–2337 (2006)CrossRef M.L. Roemhildt, K.M. Coughlin, G.D. Peura, B.C. Fleming, B.D. Beynnon: Material properties of articular cartilage in the rabbit tibial plateau, J. Biomech. 39, 2331–2337 (2006)CrossRef
31.77.
Zurück zum Zitat R.K. Korhonen, M.S. Laasanen, J. Toyras, R. Lappalainen, H.J. Helminen, J.S. Jurvelin: Fibril reinforced poroelastic model predicts specifically mechanical behavior of normal, proteoglycan depleted and collagen degraded articular cartilage, J. Biomech. 36, 1373–1379 (2003)CrossRef R.K. Korhonen, M.S. Laasanen, J. Toyras, R. Lappalainen, H.J. Helminen, J.S. Jurvelin: Fibril reinforced poroelastic model predicts specifically mechanical behavior of normal, proteoglycan depleted and collagen degraded articular cartilage, J. Biomech. 36, 1373–1379 (2003)CrossRef
31.78.
Zurück zum Zitat J.J. Garcia, D.H. Cortes: A nonlinear biphasic viscohyperelastic model for articular cartilage, J. Biomech. 39, 2991–2998 (2006)CrossRef J.J. Garcia, D.H. Cortes: A nonlinear biphasic viscohyperelastic model for articular cartilage, J. Biomech. 39, 2991–2998 (2006)CrossRef
31.79.
Zurück zum Zitat M.R. DiSilvestro, Q. Zhu, M. Wong, J.S. Jurvelin, J.K. Suh: Biphasic poroviscoelastic simulation of the unconfined compression of articular cartilage: I – simultaneous prediction of reaction force and lateral displacement, J. Biomech. Eng. 123, 191–197 (2001)CrossRef M.R. DiSilvestro, Q. Zhu, M. Wong, J.S. Jurvelin, J.K. Suh: Biphasic poroviscoelastic simulation of the unconfined compression of articular cartilage: I – simultaneous prediction of reaction force and lateral displacement, J. Biomech. Eng. 123, 191–197 (2001)CrossRef
31.80.
Zurück zum Zitat B.B. Ngu, S.M. Belkoff, D.E. Gelb, S.C. Ludwig: A biomechanical comparison of sacral pedicle screw salvage techniques, Spine 31, E166–E168 (2006)CrossRef B.B. Ngu, S.M. Belkoff, D.E. Gelb, S.C. Ludwig: A biomechanical comparison of sacral pedicle screw salvage techniques, Spine 31, E166–E168 (2006)CrossRef
31.81.
Zurück zum Zitat G.P. Paremain, V.P. Novak, R.H. Jinnah, S.M. Belkoff: Biomechanical evaluation of tension band placement for the repair of olecranon fractures, Clin. Orthop. Relat. Res. 335, 325–330 (1997) G.P. Paremain, V.P. Novak, R.H. Jinnah, S.M. Belkoff: Biomechanical evaluation of tension band placement for the repair of olecranon fractures, Clin. Orthop. Relat. Res. 335, 325–330 (1997)
31.82.
Zurück zum Zitat S.M. Belkoff, D.L. Millis, C.W. Probst: Biomechanical comparison of three internal fixations for treatment of slipped capital femoral epiphysis in immature dogs, Am. J. Vet. Res. 53, 2136–2140 (1992) S.M. Belkoff, D.L. Millis, C.W. Probst: Biomechanical comparison of three internal fixations for treatment of slipped capital femoral epiphysis in immature dogs, Am. J. Vet. Res. 53, 2136–2140 (1992)
31.83.
Zurück zum Zitat S.M. Belkoff, J.M. Mathis, L.E. Jasper: An ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty, Am. J. Neuroradiol. 23, 1647–1651 (2002) S.M. Belkoff, J.M. Mathis, L.E. Jasper: An ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty, Am. J. Neuroradiol. 23, 1647–1651 (2002)
31.84.
Zurück zum Zitat J.T. Campbell, L.C. Schon, B.G. Parks, Y. Wang, B.I. Berger: Mechanical comparison of biplanar proximal closing wedge osteotomy with plantar plate fixation versus crescentic osteotomy with screw fixation for the correction of metatarsus primus varus, Foot Ankle Int. 19, 293–299 (1998) J.T. Campbell, L.C. Schon, B.G. Parks, Y. Wang, B.I. Berger: Mechanical comparison of biplanar proximal closing wedge osteotomy with plantar plate fixation versus crescentic osteotomy with screw fixation for the correction of metatarsus primus varus, Foot Ankle Int. 19, 293–299 (1998)
31.85.
Zurück zum Zitat J.W. Smith, R. Walmsley: Factors affecting the elasticity of bone, J. Anat. 93, 503–523 (1959) J.W. Smith, R. Walmsley: Factors affecting the elasticity of bone, J. Anat. 93, 503–523 (1959)
31.86.
Zurück zum Zitat S.M. Belkoff, J.M. Mathis, L.E. Jasper, H. Deramond: The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior, Spine 26, 1537–1541 (2001)CrossRef S.M. Belkoff, J.M. Mathis, L.E. Jasper, H. Deramond: The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior, Spine 26, 1537–1541 (2001)CrossRef
31.87.
Zurück zum Zitat W.C. Hayes, S.J. Piazza, P.K. Zysset: Biomechanics of fracture risk prediction of the hip and spine by quantitative computed tomography, Radiol. Clin. North Am. 29, 1–18 (1991) W.C. Hayes, S.J. Piazza, P.K. Zysset: Biomechanics of fracture risk prediction of the hip and spine by quantitative computed tomography, Radiol. Clin. North Am. 29, 1–18 (1991)
31.88.
Zurück zum Zitat M.L. Frost, G.M. Blake, I. Fogelman: Can the who criteria for diagnosing osteoporosis be applied to calcaneal quantitative ultrasound?, Osteoporos. Int. 11, 321–330 (2000)CrossRef M.L. Frost, G.M. Blake, I. Fogelman: Can the who criteria for diagnosing osteoporosis be applied to calcaneal quantitative ultrasound?, Osteoporos. Int. 11, 321–330 (2000)CrossRef
31.89.
Zurück zum Zitat J.L. Kuhn, S.A. Goldstein, M.J. Ciarelli, L.S. Matthews: The limitations of canine trabecular bone as a model for human: a biomechanical study, J. Biomech. 22, 95–107 (1989)CrossRef J.L. Kuhn, S.A. Goldstein, M.J. Ciarelli, L.S. Matthews: The limitations of canine trabecular bone as a model for human: a biomechanical study, J. Biomech. 22, 95–107 (1989)CrossRef
31.90.
Zurück zum Zitat D.J. Sartoris, F.G. Sommer, R. Marcus, P. Madvig: Bone mineral density in the femoral neck: quantitative assessment using dual-energy projection radiography, Am. J. Roentgenol. 144, 605–611 (1985) D.J. Sartoris, F.G. Sommer, R. Marcus, P. Madvig: Bone mineral density in the femoral neck: quantitative assessment using dual-energy projection radiography, Am. J. Roentgenol. 144, 605–611 (1985)
31.91.
Zurück zum Zitat D.T. Reilly, A.H. Burstein: The elastic and ultimate properties of compact bone tissue, J. Biomech. 8, 393–405 (1975)CrossRef D.T. Reilly, A.H. Burstein: The elastic and ultimate properties of compact bone tissue, J. Biomech. 8, 393–405 (1975)CrossRef
31.92.
Zurück zum Zitat T.M. Wright, W.C. Hayes: Tensile testing of bone over a wide range of strain rates: effects of strain rate, microstructure and density, Med. Biol. Eng. 14, 671–680 (1976)CrossRef T.M. Wright, W.C. Hayes: Tensile testing of bone over a wide range of strain rates: effects of strain rate, microstructure and density, Med. Biol. Eng. 14, 671–680 (1976)CrossRef
31.93.
Zurück zum Zitat Q. Kang, Y.H. An, R.J. Friedman: Effects of multiple freezing-thawing cycles on ultimate indentation load and stiffness of bovine cancellous bone, Am. J. Vet. Res. 58, 1171–1173 (1997) Q. Kang, Y.H. An, R.J. Friedman: Effects of multiple freezing-thawing cycles on ultimate indentation load and stiffness of bovine cancellous bone, Am. J. Vet. Res. 58, 1171–1173 (1997)
31.94.
Zurück zum Zitat F. Linde, H.C.F. Sorensen: The effect of different storage methods on the mechanical properties of trabecular bone, J. Biomech. 26, 1249–1252 (1993)CrossRef F. Linde, H.C.F. Sorensen: The effect of different storage methods on the mechanical properties of trabecular bone, J. Biomech. 26, 1249–1252 (1993)CrossRef
31.95.
Zurück zum Zitat W.W. Tomford, S.H. Doppelt, H.J. Mankin, G.E. Friedlaender: Bone bank procedures, Clin. Orthop. Relat. Res. 174, 15–21 (1983) W.W. Tomford, S.H. Doppelt, H.J. Mankin, G.E. Friedlaender: Bone bank procedures, Clin. Orthop. Relat. Res. 174, 15–21 (1983)
31.96.
Zurück zum Zitat D.B. Brooks, A.H. Burstein, V.H. Frankel: The biomechanics of torsional fractures. The stress concentration effect of a drill hole, J. Bone Joint Surg. Am. 52, 507–514 (1970) D.B. Brooks, A.H. Burstein, V.H. Frankel: The biomechanics of torsional fractures. The stress concentration effect of a drill hole, J. Bone Joint Surg. Am. 52, 507–514 (1970)
31.97.
Zurück zum Zitat J.J. Elias, F.J. Frassica, E.Y. Chao: The open section effect in a long bone with a longitudinal defect - a theoretical modeling study, J. Biomech. 33, 1517–1522 (2000)CrossRef J.J. Elias, F.J. Frassica, E.Y. Chao: The open section effect in a long bone with a longitudinal defect - a theoretical modeling study, J. Biomech. 33, 1517–1522 (2000)CrossRef
31.98.
Zurück zum Zitat R.J. McBroom, E.J. Cheal, W.C. Hayes: Strength reductions from metastatic cortical defects in long bones, J. Orthop. Res. 6, 369–378 (1988)CrossRef R.J. McBroom, E.J. Cheal, W.C. Hayes: Strength reductions from metastatic cortical defects in long bones, J. Orthop. Res. 6, 369–378 (1988)CrossRef
31.99.
Zurück zum Zitat A.A. White III, M.M. Panjabi, W.O. Southwick: The four biomechanical stages of fracture repair, J. Bone Joint Surg. 59A, 188–192 (1977) A.A. White III, M.M. Panjabi, W.O. Southwick: The four biomechanical stages of fracture repair, J. Bone Joint Surg. 59A, 188–192 (1977)
31.100.
Zurück zum Zitat C.T. Rubin, L.E. Lanyon: Regulation of bone formation by applied dynamic loads, J. Bone Joint Surg. Am. 66, 397–402 (1984) C.T. Rubin, L.E. Lanyon: Regulation of bone formation by applied dynamic loads, J. Bone Joint Surg. Am. 66, 397–402 (1984)
31.101.
Zurück zum Zitat M.E. Levenston, G.S. Beaupre, M.C. Van Der Meulen: Improved method for analysis of whole bone torsion tests, J. Bone Miner. Res. 9, 1459–1465 (1994)CrossRef M.E. Levenston, G.S. Beaupre, M.C. Van Der Meulen: Improved method for analysis of whole bone torsion tests, J. Bone Miner. Res. 9, 1459–1465 (1994)CrossRef
31.102.
Zurück zum Zitat S.L. Salkeld, L.P. Patron, R.L. Barrack, S.D. Cook: The effect of osteogenic protein-1 on the healing of segmental bone defects treated with autograft or allograft bone, J. Bone Joint Surg. Am. 83, 803–816 (2001) S.L. Salkeld, L.P. Patron, R.L. Barrack, S.D. Cook: The effect of osteogenic protein-1 on the healing of segmental bone defects treated with autograft or allograft bone, J. Bone Joint Surg. Am. 83, 803–816 (2001)
31.103.
Zurück zum Zitat M.B. Henley, L.B. Bone, B. Parker: Operative management of intra-articular fractures of the distal humerus, J. Orthop. Trauma 1, 24–35 (1987)CrossRef M.B. Henley, L.B. Bone, B. Parker: Operative management of intra-articular fractures of the distal humerus, J. Orthop. Trauma 1, 24–35 (1987)CrossRef
31.104.
Zurück zum Zitat H.T. Aro, M.D. Markel, E.Y. Chao: Cortical bone reactions at the interface of external fixation half-pins under different loading conditions, J. Trauma 35, 776–785 (1993)CrossRef H.T. Aro, M.D. Markel, E.Y. Chao: Cortical bone reactions at the interface of external fixation half-pins under different loading conditions, J. Trauma 35, 776–785 (1993)CrossRef
31.105.
Zurück zum Zitat L. Cristofolini, M. Viceconti, A. Cappello, A. Toni: Mechanical validation of whole bone composite femur models, J. Biomech. 29, 525–535 (1996)CrossRef L. Cristofolini, M. Viceconti, A. Cappello, A. Toni: Mechanical validation of whole bone composite femur models, J. Biomech. 29, 525–535 (1996)CrossRef
31.106.
Zurück zum Zitat J.A. Szivek, M. Thomas, J.B. Benjamin: Characterization of a synthetic foam as a model for human cancellous bone, J. Appl. Biomater. 4, 269–272 (1993)CrossRef J.A. Szivek, M. Thomas, J.B. Benjamin: Characterization of a synthetic foam as a model for human cancellous bone, J. Appl. Biomater. 4, 269–272 (1993)CrossRef
31.107.
Zurück zum Zitat J.A. Szivek, J.D. Thompson, J.B. Benjamin: Characterization of three formulations of a synthetic foam as models for a range of human cancellous bone types, J. Appl. Biomater. 6, 125–128 (1995)CrossRef J.A. Szivek, J.D. Thompson, J.B. Benjamin: Characterization of three formulations of a synthetic foam as models for a range of human cancellous bone types, J. Appl. Biomater. 6, 125–128 (1995)CrossRef
31.108.
Zurück zum Zitat S. Uta: Development of synthetic bone models for the evaluation of fracture fixation devices, Nippon Seikeigeka Gakkai Zasshi 66, 1156–1164 (1992) S. Uta: Development of synthetic bone models for the evaluation of fracture fixation devices, Nippon Seikeigeka Gakkai Zasshi 66, 1156–1164 (1992)
31.109.
Zurück zum Zitat L. Cristofolini, M. Viceconti: Mechanical validation of whole bone composite tibia models, J. Biomech. 33, 279–288 (2000)CrossRef L. Cristofolini, M. Viceconti: Mechanical validation of whole bone composite tibia models, J. Biomech. 33, 279–288 (2000)CrossRef
31.110.
Zurück zum Zitat L. Orienti, M. Fini, M. Rocca, G. Giavaresi, M. Guzzardella, A. Moroni, R. Giardino: Measurement of insertion torque of tapered external fixation pins: a comparison between two experimental models, J. Biomed. Mater Res. 48, 216–219 (1999)CrossRef L. Orienti, M. Fini, M. Rocca, G. Giavaresi, M. Guzzardella, A. Moroni, R. Giardino: Measurement of insertion torque of tapered external fixation pins: a comparison between two experimental models, J. Biomed. Mater Res. 48, 216–219 (1999)CrossRef
31.111.
Zurück zum Zitat J.A. Szivek, R.L. Gealer: Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance, J. Appl. Biomater. 2, 277–280 (1991)CrossRef J.A. Szivek, R.L. Gealer: Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance, J. Appl. Biomater. 2, 277–280 (1991)CrossRef
31.112.
Zurück zum Zitat T. Marqueen, J. Owen, G. Nicandri, J. Wayne, J. Carr: Comparison of the syndesmotic staple to the transsyndesmotic screw: a biomechanical study, Foot Ankle Int. 26, 224–230 (2005) T. Marqueen, J. Owen, G. Nicandri, J. Wayne, J. Carr: Comparison of the syndesmotic staple to the transsyndesmotic screw: a biomechanical study, Foot Ankle Int. 26, 224–230 (2005)
31.113.
Zurück zum Zitat A.A. White III, M.M. Panjabi: Kinematics of the spine. In: Clinical Biomechanics of the Spine (JB Lippincott, Philadelphia 1990) A.A. White III, M.M. Panjabi: Kinematics of the spine. In: Clinical Biomechanics of the Spine (JB Lippincott, Philadelphia 1990)
31.114.
Zurück zum Zitat L.P. Maletsky, J. Sun, N.A. Morton: Accuracy of an optical active-marker system to track the relative motion of rigid bodies, J. Biomech. 40, 682–685 (2007)CrossRef L.P. Maletsky, J. Sun, N.A. Morton: Accuracy of an optical active-marker system to track the relative motion of rigid bodies, J. Biomech. 40, 682–685 (2007)CrossRef
31.115.
Zurück zum Zitat G. Ferrigno, A. Pedotti: ELITE: a digital dedicated hardware system for movement analysis via real-time tv signal processing, IEEE Trans. Biomed. Eng. 32, 943–950 (1985)CrossRef G. Ferrigno, A. Pedotti: ELITE: a digital dedicated hardware system for movement analysis via real-time tv signal processing, IEEE Trans. Biomed. Eng. 32, 943–950 (1985)CrossRef
31.116.
Zurück zum Zitat C.G. Meskers, H. Fraterman, F.C. van der Helm, H.M. Vermeulen, P.M. Rozing: Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies, J. Biomech. 32, 629–633 (1999)CrossRef C.G. Meskers, H. Fraterman, F.C. van der Helm, H.M. Vermeulen, P.M. Rozing: Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies, J. Biomech. 32, 629–633 (1999)CrossRef
31.117.
Zurück zum Zitat A.E. Engin, R.D. Peindl, N. Berme, I. Kaleps: Kinematic and force data collection in biomechanics by means of sonic emitters–I: Kinematic data collection methodology, J. Biomech. Eng. 106, 204–211 (1984)CrossRef A.E. Engin, R.D. Peindl, N. Berme, I. Kaleps: Kinematic and force data collection in biomechanics by means of sonic emitters–I: Kinematic data collection methodology, J. Biomech. Eng. 106, 204–211 (1984)CrossRef
31.118.
Zurück zum Zitat T.M. Wright, W.C. Hayes: Strain gage application on compact bone, J. Biomech. 12, 471–475 (1979)CrossRef T.M. Wright, W.C. Hayes: Strain gage application on compact bone, J. Biomech. 12, 471–475 (1979)CrossRef
31.119.
Zurück zum Zitat B.K. Bay: Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone, J. Orthop. Res. 13, 258–267 (1995)CrossRef B.K. Bay: Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone, J. Orthop. Res. 13, 258–267 (1995)CrossRef
31.120.
Zurück zum Zitat A. Rohlmann, F. Graichen, U. Weber, G. Bergmann: Volvo award winner in biomechanical studies. Monitoring in vivo implant loads with a telemeterized internal spinal fixation device, Spine 25, 2981–2986 (2000)CrossRef A. Rohlmann, F. Graichen, U. Weber, G. Bergmann: Volvo award winner in biomechanical studies. Monitoring in vivo implant loads with a telemeterized internal spinal fixation device, Spine 25, 2981–2986 (2000)CrossRef
31.121.
Zurück zum Zitat G. Bergmann, F. Graichen, A. Rohlmann: Hip joint loading during walking and running, measured in two patients, J. Biomech. 26, 969–990 (1993)CrossRef G. Bergmann, F. Graichen, A. Rohlmann: Hip joint loading during walking and running, measured in two patients, J. Biomech. 26, 969–990 (1993)CrossRef
31.122.
Zurück zum Zitat P.J. Atkinson, R.C. Haut: Subfracture insult to the human cadaver patellofemoral joint produces occult injury, J. Orthop. Res. 13, 936–944 (1995)CrossRef P.J. Atkinson, R.C. Haut: Subfracture insult to the human cadaver patellofemoral joint produces occult injury, J. Orthop. Res. 13, 936–944 (1995)CrossRef
31.123.
Zurück zum Zitat S.J. Svoboda, K. McHale, S.M. Belkoff, K.S. Cohen, W.R. Klemme: The effects of tibial malrotation on the biomechanics of the tibiotalar joint, Foot Ankle Int. 23, 102–106 (2002) S.J. Svoboda, K. McHale, S.M. Belkoff, K.S. Cohen, W.R. Klemme: The effects of tibial malrotation on the biomechanics of the tibiotalar joint, Foot Ankle Int. 23, 102–106 (2002)
31.124.
Zurück zum Zitat L.A. Whitaker: Characteristics of skin of importance to the surgeon, Int. Surg. 57, 877–879 (1972) L.A. Whitaker: Characteristics of skin of importance to the surgeon, Int. Surg. 57, 877–879 (1972)
31.125.
Zurück zum Zitat I.A. Brown: A scanning electron microscope study of the effects of uniaxial tension on human skin, Br. J. Dermatol. 89, 383–393 (1973)CrossRef I.A. Brown: A scanning electron microscope study of the effects of uniaxial tension on human skin, Br. J. Dermatol. 89, 383–393 (1973)CrossRef
31.126.
Zurück zum Zitat B. Finlay: Scanning electron microscopy of the human dermis under uni-axial strain, Biomed. Eng. 4, 322–327 (1969) B. Finlay: Scanning electron microscopy of the human dermis under uni-axial strain, Biomed. Eng. 4, 322–327 (1969)
31.127.
Zurück zum Zitat R.M. Lavker, P.S. Zheng, G. Dong: Aged skin: A study by light, transmission electron, and scanning electron microscopy, J. Invest. Dermatol. 88, 44s–51s (1987)CrossRef R.M. Lavker, P.S. Zheng, G. Dong: Aged skin: A study by light, transmission electron, and scanning electron microscopy, J. Invest. Dermatol. 88, 44s–51s (1987)CrossRef
31.128.
Zurück zum Zitat M.D. Ridge, V. Wright: Mechanical properties of skin: A bioengineering study of skin structure, J. Appl. Physiol. 21, 1602–1606 (1966) M.D. Ridge, V. Wright: Mechanical properties of skin: A bioengineering study of skin structure, J. Appl. Physiol. 21, 1602–1606 (1966)
31.129.
Zurück zum Zitat M.D. Ridge, V. Wright: The directional effects of skin. A bio-engineering study of skin with particular reference to langerʼs lines, J. Invest. Dermatol. 46, 341–346 (1966) M.D. Ridge, V. Wright: The directional effects of skin. A bio-engineering study of skin with particular reference to langerʼs lines, J. Invest. Dermatol. 46, 341–346 (1966)
31.130.
Zurück zum Zitat J.F. Manschot, A.J. Brakkee: The measurement and modelling of the mechanical properties of human skin in vivo – I. The measurement, J. Biomech. 19, 511–515 (1986)CrossRef J.F. Manschot, A.J. Brakkee: The measurement and modelling of the mechanical properties of human skin in vivo – I. The measurement, J. Biomech. 19, 511–515 (1986)CrossRef
31.131.
Zurück zum Zitat B. Finlay: Dynamic mechanical testing of human skin ʼin vivoʼ, J. Biomech. 3, 557–568 (1970)CrossRef B. Finlay: Dynamic mechanical testing of human skin ʼin vivoʼ, J. Biomech. 3, 557–568 (1970)CrossRef
31.132.
Zurück zum Zitat R. Sanders: Torsional elasticity of human skin in vivo, Pflugers Arch. 342, 255–260 (1973)CrossRef R. Sanders: Torsional elasticity of human skin in vivo, Pflugers Arch. 342, 255–260 (1973)CrossRef
31.133.
Zurück zum Zitat P.F.F. Wijn, A.J.M. Brakkee, G.J.M. Steinen, A.J.G. Vendrick: Mechanical properties of human skin in vivo for small deformatons: a comparison of uniaxial strain and torsion measurements. In: Bodsore Biomechanics (McMillan, London 1976) pp. 103–108 P.F.F. Wijn, A.J.M. Brakkee, G.J.M. Steinen, A.J.G. Vendrick: Mechanical properties of human skin in vivo for small deformatons: a comparison of uniaxial strain and torsion measurements. In: Bodsore Biomechanics (McMillan, London 1976) pp. 103–108
31.134.
Zurück zum Zitat R. Grahame: A method for measuring human skin elasticity in vivo with observations of the effects of age, sex and pregnancy, Clin. Sci. 39, 223–229 (1970) R. Grahame: A method for measuring human skin elasticity in vivo with observations of the effects of age, sex and pregnancy, Clin. Sci. 39, 223–229 (1970)
31.135.
Zurück zum Zitat R. Grahame, P.J. Holt: The influence of ageing on the in vivo elasticity of human skin, Gerontologia 15, 121–139 (1969)CrossRef R. Grahame, P.J. Holt: The influence of ageing on the in vivo elasticity of human skin, Gerontologia 15, 121–139 (1969)CrossRef
31.136.
Zurück zum Zitat L.H. Jansen, P.B. Rottier: Some mechanical properties of human abdominal skin measured on excised strips, Dermatologica 117, 65–83 (1958)CrossRef L.H. Jansen, P.B. Rottier: Some mechanical properties of human abdominal skin measured on excised strips, Dermatologica 117, 65–83 (1958)CrossRef
31.137.
Zurück zum Zitat T. Cook, H. Alexander, M. Cohen: Experimental method for determining the 2-dimensional mechanical properties of living human skin, Med. Biol. Eng. Comput. 15, 381–390 (1977)CrossRef T. Cook, H. Alexander, M. Cohen: Experimental method for determining the 2-dimensional mechanical properties of living human skin, Med. Biol. Eng. Comput. 15, 381–390 (1977)CrossRef
31.138.
Zurück zum Zitat H. Alexander, T.H. Cook: Accounting for natural tension in the mechanical testing of human skin, J. Invest. Dermatol. 69, 310–314 (1977)CrossRef H. Alexander, T.H. Cook: Accounting for natural tension in the mechanical testing of human skin, J. Invest. Dermatol. 69, 310–314 (1977)CrossRef
31.139.
Zurück zum Zitat S.M. Belkoff, R.C. Haut: A structural model used to evaluate the changing microstructure of maturing rat skin, J. Biomech. 24, 711–720 (1991)CrossRef S.M. Belkoff, R.C. Haut: A structural model used to evaluate the changing microstructure of maturing rat skin, J. Biomech. 24, 711–720 (1991)CrossRef
31.140.
Zurück zum Zitat R.C. Haut: The effects of orientation and location on the strength of dorsal rat skin in high and low speed tensile failure experiments, J. Biomech. Eng. 111, 136–140 (1989)CrossRef R.C. Haut: The effects of orientation and location on the strength of dorsal rat skin in high and low speed tensile failure experiments, J. Biomech. Eng. 111, 136–140 (1989)CrossRef
31.141.
Zurück zum Zitat Y. Lanir, Y.C. Fung: Two-dimensional mechanical properties of rabbit skin. II. Experimental results, J. Biomech. 7, 171–182 (1974)CrossRef Y. Lanir, Y.C. Fung: Two-dimensional mechanical properties of rabbit skin. II. Experimental results, J. Biomech. 7, 171–182 (1974)CrossRef
31.142.
Zurück zum Zitat A.E. Green, J.E. Adkins (Eds.): Large Elastic Deformations (Oxford Univ. Press, Oxford 1971) A.E. Green, J.E. Adkins (Eds.): Large Elastic Deformations (Oxford Univ. Press, Oxford 1971)
31.143.
Zurück zum Zitat R.W. Snyder, L.H. Lee: Experimental study of biological tissue subjected to pure shear, J. Biomech. 8, 415–419 (1975)CrossRef R.W. Snyder, L.H. Lee: Experimental study of biological tissue subjected to pure shear, J. Biomech. 8, 415–419 (1975)CrossRef
Metadaten
Titel
Experimental Methods in Biological Tissue Testing
verfasst von
Stephen M. Belkoff, Prof.
Roger C. Haut, Prof.
Copyright-Jahr
2008
Verlag
Springer US
DOI
https://doi.org/10.1007/978-0-387-30877-7_31

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.