Skip to main content

2013 | OriginalPaper | Buchkapitel

4. Finite Element Modelling

verfasst von : Muhammad Ikman Ishak, Mohammed Rafiq Abdul Kadir

Erschienen in: Biomechanics in Dentistry: Evaluation of Different Surgical Approaches to Treat Atrophic Maxilla Patients

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this chapter, all methods involved to generate 3D finite element models are presented in detail. The finite element modelling initially started by the reconstruction of bone models and then followed by the development of implant models. The 3D anatomical model of craniofacial presented in this text was obtained by the original maxilla with a high degree of bone resorption. The simulated implantation procedure would be conducted to place the implants into bone site afterwards. The prepared models were assigned with material properties, contact parameters, boundary conditions and simulated loadings before proceeding to the analysis. The 3D FEA was then performed with the data of equivalent von Mises stress and displacements within the respective models were presented numerically and plotted in spectrum colouring scale.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Uchida H, Kobayashi K, Nagao M (1989) Measurement in vivo of masticatory mucosal thickness with 20 MHz B-mode ultrasonic diagnostic equipment. J Dent Res 68(2):95–100CrossRef Uchida H, Kobayashi K, Nagao M (1989) Measurement in vivo of masticatory mucosal thickness with 20 MHz B-mode ultrasonic diagnostic equipment. J Dent Res 68(2):95–100CrossRef
2.
Zurück zum Zitat Teixeira ER, Sato Y, Akagawa Y, Shindoi N (1998) A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil 25 (4):299–303 Teixeira ER, Sato Y, Akagawa Y, Shindoi N (1998) A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil 25 (4):299–303
3.
Zurück zum Zitat Maló P, de Araujo Nobre M, Lopes I (2008) A new approach to rehabilitate the severely atrophic maxilla using extra maxillary anchored implants in immediate function: a pilot study. J Prosthet Dent 100(5):354–366CrossRef Maló P, de Araujo Nobre M, Lopes I (2008) A new approach to rehabilitate the severely atrophic maxilla using extra maxillary anchored implants in immediate function: a pilot study. J Prosthet Dent 100(5):354–366CrossRef
4.
Zurück zum Zitat Eufinger H, Gellrich NC, Sandmann D, Dieckmann J (1997) Descriptive and metric classification of jaw atrophy: an evaluation of 104 mandibles and 96 maxillae of dried skulls. Int J Oral Maxillofac Surg 26(1):23–28CrossRef Eufinger H, Gellrich NC, Sandmann D, Dieckmann J (1997) Descriptive and metric classification of jaw atrophy: an evaluation of 104 mandibles and 96 maxillae of dried skulls. Int J Oral Maxillofac Surg 26(1):23–28CrossRef
5.
Zurück zum Zitat Uchida Y, Goto M, Katsuki T, Akiyoshi T (2001) Measurement of the maxilla and zygoma as an aid in installing zygomatic implant. J Oral Maxillofac Surg 59:1193–1198CrossRef Uchida Y, Goto M, Katsuki T, Akiyoshi T (2001) Measurement of the maxilla and zygoma as an aid in installing zygomatic implant. J Oral Maxillofac Surg 59:1193–1198CrossRef
6.
Zurück zum Zitat Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW (2008) Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. J Dent 36(6):409–417CrossRef Huang HL, Hsu JT, Fuh LJ, Tu MG, Ko CC, Shen YW (2008) Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. J Dent 36(6):409–417CrossRef
7.
Zurück zum Zitat Ujigawa K, Kato Y, Kizu Y, Tonogi M, Yamane GY (2007) Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures. Int J Oral Maxillofac Surg 36(7):620–625CrossRef Ujigawa K, Kato Y, Kizu Y, Tonogi M, Yamane GY (2007) Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures. Int J Oral Maxillofac Surg 36(7):620–625CrossRef
8.
Zurück zum Zitat Cattaneo PM, Dalstra M, Melsen B (2003) The transfer of occlusal forces through the maxillary molars: a finite element study. Am J Orthod Dentofac Orthop 123(4):367–373CrossRef Cattaneo PM, Dalstra M, Melsen B (2003) The transfer of occlusal forces through the maxillary molars: a finite element study. Am J Orthod Dentofac Orthop 123(4):367–373CrossRef
9.
Zurück zum Zitat Jensen OT, Adams MW (2009) The maxillary M-4: a technical and biomechanical note for all-on-4 management of severe maxillary atrophy: report of three cases. J Oral Maxillofac Surg 67:1739–1744CrossRef Jensen OT, Adams MW (2009) The maxillary M-4: a technical and biomechanical note for all-on-4 management of severe maxillary atrophy: report of three cases. J Oral Maxillofac Surg 67:1739–1744CrossRef
10.
Zurück zum Zitat Lin CL, Chang SH, Wang JC (2006) Finite element analysis of biomechanical interactions of a tooth-implant splinting system for various bone qualities. Chang Gung Med J 29(2):143–153 Lin CL, Chang SH, Wang JC (2006) Finite element analysis of biomechanical interactions of a tooth-implant splinting system for various bone qualities. Chang Gung Med J 29(2):143–153
11.
Zurück zum Zitat Geng JP, Tan KBC, Liu GR (2001) Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 85(6):585–598CrossRef Geng JP, Tan KBC, Liu GR (2001) Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 85(6):585–598CrossRef
12.
Zurück zum Zitat Koca OL, Eskitascioglu G, Usumez A (2005) Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor. J Prosthet Dent 93(1):38–44CrossRef Koca OL, Eskitascioglu G, Usumez A (2005) Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor. J Prosthet Dent 93(1):38–44CrossRef
13.
Zurück zum Zitat Meyer U, Vollmer D, Runte C, Bourauel C, Joos U (2001) Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. J Cranio Maxill Surg 29(2):100–105CrossRef Meyer U, Vollmer D, Runte C, Bourauel C, Joos U (2001) Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. J Cranio Maxill Surg 29(2):100–105CrossRef
14.
Zurück zum Zitat Cheng YY, Cheung WL, Chow TW (2010) Strain analysis of maxillary complete denture with three-dimensional finite element method. J Prosthet Dent 103(5):309–318CrossRef Cheng YY, Cheung WL, Chow TW (2010) Strain analysis of maxillary complete denture with three-dimensional finite element method. J Prosthet Dent 103(5):309–318CrossRef
15.
Zurück zum Zitat Manda M, Galanis C, Georgiopoulos V, Provatidis C, Koidis P (2010) Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: a three-dimensional finite element analysis. J Prosthet Dent 103(2):91–100CrossRef Manda M, Galanis C, Georgiopoulos V, Provatidis C, Koidis P (2010) Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: a three-dimensional finite element analysis. J Prosthet Dent 103(2):91–100CrossRef
16.
Zurück zum Zitat Rohlig BG (2004) The use of angulated implants in the maxillary tuberosity region. Dissertation, University of Marburg, Istanbul Rohlig BG (2004) The use of angulated implants in the maxillary tuberosity region. Dissertation, University of Marburg, Istanbul
17.
Zurück zum Zitat Bonnet AS, Postaire M, Lipinski P (2009) Biomechanical study of mandible bone supporting a four-implant retained bridge: finite element analysis of the influence of bone anisotropy and foodstuff position. Med Eng Phys 31(7):806–815CrossRef Bonnet AS, Postaire M, Lipinski P (2009) Biomechanical study of mandible bone supporting a four-implant retained bridge: finite element analysis of the influence of bone anisotropy and foodstuff position. Med Eng Phys 31(7):806–815CrossRef
18.
Zurück zum Zitat Duyck J, Naert I, Oosterwyck Van, Ronold HJ, Vander Sloten J, Ellingsen J (2001) The influence of static and dynamic on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Impl Res 12:207–218CrossRef Duyck J, Naert I, Oosterwyck Van, Ronold HJ, Vander Sloten J, Ellingsen J (2001) The influence of static and dynamic on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Impl Res 12:207–218CrossRef
19.
Zurück zum Zitat Li T, Kong L, Wang Y, Hu K, Song L, Liu B, Li D, Shao J, Ding Y (2009) Selection of optimal dental implant diameter and length in type IV bone: a three-dimensional finite element analysis. Int J Oral Maxillofac Surg 38(10):1077–1083CrossRef Li T, Kong L, Wang Y, Hu K, Song L, Liu B, Li D, Shao J, Ding Y (2009) Selection of optimal dental implant diameter and length in type IV bone: a three-dimensional finite element analysis. Int J Oral Maxillofac Surg 38(10):1077–1083CrossRef
Metadaten
Titel
Finite Element Modelling
verfasst von
Muhammad Ikman Ishak
Mohammed Rafiq Abdul Kadir
Copyright-Jahr
2013
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-32603-5_4

Neuer Inhalt