Skip to main content

2013 | OriginalPaper | Buchkapitel

19. Fundamentals of Linking Tribology and Corrosion (Tribocorrosion) for Medical Applications: Bio-tribocorrosion

verfasst von : V. A. Barão, C. Sukotjo, M. T. Mathew

Erschienen in: Tribology for Scientists and Engineers

Verlag: Springer New York

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Metal/alloys have been used in orthopedic and dental implants for many years. In a physiological environment, they are susceptible to materials degradation affecting its performance and lead to gradual and early failures due to the continuous exposure to the variation in in vivo mechanical and chemical conditions. Tribocorrosion is a new area of research that links tribology and corrosion, which can be defined as the irreversible material degradation process resulting from the synergistic interaction of wear and corrosion phenomena on surfaces subjected to a relative contact movement in biological environments. This book chapter describes some fundamental aspects about this new research area and focused on its significances in biomedical application, namely, orthopedics and dentistry.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Mischler S (2008) Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation. Tribol Int 41:573–583CrossRef Mischler S (2008) Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation. Tribol Int 41:573–583CrossRef
2.
Zurück zum Zitat Yan Y, Neville A, Dowson D, Williams S, Fisher J (2008) Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses. Proc Inst Mech Eng Part J J Eng Tribol 222:483–492. doi:10.1243/13506501jet366 CrossRef Yan Y, Neville A, Dowson D, Williams S, Fisher J (2008) Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses. Proc Inst Mech Eng Part J J Eng Tribol 222:483–492. doi:10.​1243/​13506501jet366 CrossRef
3.
Zurück zum Zitat Mathew MT, Barao VA, Yuan JC, Assunção WG, Sukotjo C, Wimmer MA (2012) What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater 8:71–85CrossRef Mathew MT, Barao VA, Yuan JC, Assunção WG, Sukotjo C, Wimmer MA (2012) What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater 8:71–85CrossRef
4.
Zurück zum Zitat Mathew MT, Runa MJ, Laurent M, Jacobs JJ, Rocha LA, Wimmer MA (2011) Tribocorrosion behavior of Co-Cr-Mo alloy for hip prosthesis as a function of loads: a comparison between two testing systems. Wear 271:1210–1219. doi:10.1016/j.wear.2011.01.086 CrossRef Mathew MT, Runa MJ, Laurent M, Jacobs JJ, Rocha LA, Wimmer MA (2011) Tribocorrosion behavior of Co-Cr-Mo alloy for hip prosthesis as a function of loads: a comparison between two testing systems. Wear 271:1210–1219. doi:10.​1016/​j.​wear.​2011.​01.​086 CrossRef
6.
Zurück zum Zitat Mathew MT, Srinivasa Pai P, Pourzal R, Fischer A, Wimmer MA (2009) Significance of tribocorrosion in biomedical applications: overview and current status. Adv Tribol Article ID 250986:250912 pages Mathew MT, Srinivasa Pai P, Pourzal R, Fischer A, Wimmer MA (2009) Significance of tribocorrosion in biomedical applications: overview and current status. Adv Tribol Article ID 250986:250912 pages
7.
10.
Zurück zum Zitat More NS, Diomidis N, Paul SN, Roy M, Mischler S (2011) Tribocorrosion behavior of beta titanium alloys in physiological solutions containing synovial components. Mater Sci Eng C Mater Biol Appl 31:400–408. doi:10.1016/j.msec.2010.10.021 CrossRef More NS, Diomidis N, Paul SN, Roy M, Mischler S (2011) Tribocorrosion behavior of beta titanium alloys in physiological solutions containing synovial components. Mater Sci Eng C Mater Biol Appl 31:400–408. doi:10.​1016/​j.​msec.​2010.​10.​021 CrossRef
12.
Zurück zum Zitat Stack MM, Mathew MT, Hodge C (2011) Micro-abrasion-corrosion interactions of Ni-Cr/WC based coatings: approaches to construction of tribo-corrosion maps for the abrasion-corrosion synergism. Electrochim Acta 56:8249–8259. doi:10.1016/j.electacta.2011.06.064 CrossRef Stack MM, Mathew MT, Hodge C (2011) Micro-abrasion-corrosion interactions of Ni-Cr/WC based coatings: approaches to construction of tribo-corrosion maps for the abrasion-corrosion synergism. Electrochim Acta 56:8249–8259. doi:10.​1016/​j.​electacta.​2011.​06.​064 CrossRef
13.
14.
Zurück zum Zitat Eddoumy F, Addiego F, Celis JP, Buchheit O, Berradja A, Muller R et al (2011) Reciprocating sliding of uniaxially-stretched ultra-high molecular weight polyethylene for medical device applications. Wear 272:50–61. doi:10.1016/j.wear.2011.07.013 CrossRef Eddoumy F, Addiego F, Celis JP, Buchheit O, Berradja A, Muller R et al (2011) Reciprocating sliding of uniaxially-stretched ultra-high molecular weight polyethylene for medical device applications. Wear 272:50–61. doi:10.​1016/​j.​wear.​2011.​07.​013 CrossRef
15.
Zurück zum Zitat Stack MM, Abdulrahman GH (2010) Mapping erosion-corrosion of carbon steel in oil exploration conditions: some new approaches to characterizing mechanisms and synergies. Tribol Int 43:1268–1277CrossRef Stack MM, Abdulrahman GH (2010) Mapping erosion-corrosion of carbon steel in oil exploration conditions: some new approaches to characterizing mechanisms and synergies. Tribol Int 43:1268–1277CrossRef
16.
Zurück zum Zitat Celis JP, Franck M, Roos JR, Kreutz EW, Gasser A, Wehner M et al (1992) Potential of photon and particle beams for surface-treatment of thin ceramic coatings. Appl Surf Sci 54:322–329CrossRef Celis JP, Franck M, Roos JR, Kreutz EW, Gasser A, Wehner M et al (1992) Potential of photon and particle beams for surface-treatment of thin ceramic coatings. Appl Surf Sci 54:322–329CrossRef
17.
Zurück zum Zitat Mischler S, Debaud S, Landolt D (1998) Wear-accelerated corrosion of passive metals in tribocorrosion systems. J Electrochem Soc 145:750–758CrossRef Mischler S, Debaud S, Landolt D (1998) Wear-accelerated corrosion of passive metals in tribocorrosion systems. J Electrochem Soc 145:750–758CrossRef
18.
19.
Zurück zum Zitat Geringer J, Tatkiewicz W, Rouchouse G (2011) Wear behavior of PAEK, poly(aryl-ether-ketone), under physiological conditions, outlooks for performing these materials in the field of hip prosthesis. Wear 271:2793–2803. doi:10.1016/j.wear.2011.05.034 CrossRef Geringer J, Tatkiewicz W, Rouchouse G (2011) Wear behavior of PAEK, poly(aryl-ether-ketone), under physiological conditions, outlooks for performing these materials in the field of hip prosthesis. Wear 271:2793–2803. doi:10.​1016/​j.​wear.​2011.​05.​034 CrossRef
20.
Zurück zum Zitat Geringer J, Boyer B, Farizon F (2011) Understanding the dual mobility concept for total hip arthroplasty. Investigations on a multiscale analysis-highlighting the role of arthrofibrosis. Wear 271:2379–2385. doi:10.1016/j.wear.2011.02.027 CrossRef Geringer J, Boyer B, Farizon F (2011) Understanding the dual mobility concept for total hip arthroplasty. Investigations on a multiscale analysis-highlighting the role of arthrofibrosis. Wear 271:2379–2385. doi:10.​1016/​j.​wear.​2011.​02.​027 CrossRef
21.
Zurück zum Zitat Pellier J, Geringer J, Forest B (2011) Fretting-corrosion between 316L SS and PMMA: influence of ionic strength, protein and electrochemical conditions on material wear. Application to orthopaedic implants. Wear 271:1563–1571. doi:10.1016/j.wear.2011.01.082 CrossRef Pellier J, Geringer J, Forest B (2011) Fretting-corrosion between 316L SS and PMMA: influence of ionic strength, protein and electrochemical conditions on material wear. Application to orthopaedic implants. Wear 271:1563–1571. doi:10.​1016/​j.​wear.​2011.​01.​082 CrossRef
23.
Zurück zum Zitat Geringer J, Forest B, Combrade P (2007) Wear of poly (methyl methacrylate) against a metallic surface in dry conditions. Polymer Eng Sci 47:633–648. doi:10.1002/Pen.20736 CrossRef Geringer J, Forest B, Combrade P (2007) Wear of poly (methyl methacrylate) against a metallic surface in dry conditions. Polymer Eng Sci 47:633–648. doi:10.​1002/​Pen.​20736 CrossRef
26.
Zurück zum Zitat Souza JCM, Henriques M, Oliveira R, Teughels W, Celis JP, Rocha LA (2010) Do oral biofilms influence the wear and corrosion behavior of titanium? Biofouling 26:471–478CrossRef Souza JCM, Henriques M, Oliveira R, Teughels W, Celis JP, Rocha LA (2010) Do oral biofilms influence the wear and corrosion behavior of titanium? Biofouling 26:471–478CrossRef
29.
Zurück zum Zitat Kanagaraj S, Mathew MT, Fonseca A, Oliveira MSA, Simoes JAO, Rocha LA (2010) Tribological characterisation of carbon nanotubes/ultrahigh molecular weight polyethylene composites: the effect of sliding distance. Int J Surf Sci Eng 4:305–321CrossRef Kanagaraj S, Mathew MT, Fonseca A, Oliveira MSA, Simoes JAO, Rocha LA (2010) Tribological characterisation of carbon nanotubes/ultrahigh molecular weight polyethylene composites: the effect of sliding distance. Int J Surf Sci Eng 4:305–321CrossRef
30.
Zurück zum Zitat Vieira AC, Ribeiro AR, Rocha LA, Celis JP (2006) Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva. Wear 261:994–1001CrossRef Vieira AC, Ribeiro AR, Rocha LA, Celis JP (2006) Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva. Wear 261:994–1001CrossRef
33.
34.
Zurück zum Zitat Barao VA, Mathew MT, Assuncao WG, Yuan JC, Wimmer MA, Sukotjo C (2011) Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH—an electrochemical study. Clin Oral Implants Res. doi:10.1111/j.1600-0501.2011.02265.x Barao VA, Mathew MT, Assuncao WG, Yuan JC, Wimmer MA, Sukotjo C (2011) Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH—an electrochemical study. Clin Oral Implants Res. doi:10.​1111/​j.​1600-0501.​2011.​02265.​x
38.
Zurück zum Zitat Milosev I, Remskar M (2009) In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses. J Biomed Mater Res A 91A:1100–1110. doi:10.1002/Jbm.A.32301 CrossRef Milosev I, Remskar M (2009) In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses. J Biomed Mater Res A 91A:1100–1110. doi:10.​1002/​Jbm.​A.​32301 CrossRef
40.
Zurück zum Zitat Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J et al (1998) Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 80:1447–1458 Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J et al (1998) Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 80:1447–1458
41.
Zurück zum Zitat Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC (1998) Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42:103–111CrossRef Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC (1998) Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42:103–111CrossRef
42.
Zurück zum Zitat DiCarlo EF, Bullough PG (1992) The biologic responses to orthopedic implants and their wear debris. Clin Mater 9:235–260CrossRef DiCarlo EF, Bullough PG (1992) The biologic responses to orthopedic implants and their wear debris. Clin Mater 9:235–260CrossRef
43.
Zurück zum Zitat Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83-A:428–436 Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83-A:428–436
44.
Zurück zum Zitat Lenz R, Mittelmeier W, Hansmann D, Brem R, Diehl P, Fritsche A et al (2009) Response of human osteoblasts exposed to wear particles generated at the interface of total hip stems and bone cement. J Biomed Mater Res A 89:370–378. doi:10.1002/jbm.a.31996 CrossRef Lenz R, Mittelmeier W, Hansmann D, Brem R, Diehl P, Fritsche A et al (2009) Response of human osteoblasts exposed to wear particles generated at the interface of total hip stems and bone cement. J Biomed Mater Res A 89:370–378. doi:10.​1002/​jbm.​a.​31996 CrossRef
45.
Zurück zum Zitat Gil RA, Munoz AI (2011) Influence of the sliding velocity and the applied potential on the corrosion and wear behavior of HC Co-Cr-Mo biomedical alloy in simulated body fluids. J Mech Behav Biomed Mater 4:2090–2102. doi:10.1016/j.jmbbm.2011.07.008 CrossRef Gil RA, Munoz AI (2011) Influence of the sliding velocity and the applied potential on the corrosion and wear behavior of HC Co-Cr-Mo biomedical alloy in simulated body fluids. J Mech Behav Biomed Mater 4:2090–2102. doi:10.​1016/​j.​jmbbm.​2011.​07.​008 CrossRef
47.
Zurück zum Zitat Manhabosco TM, Tamborim SM, dos Santos CB, Muller IL (2011) Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution. Corros Sci 53:1786–1793. doi:10.1016/j.corsci.2011.01.057 CrossRef Manhabosco TM, Tamborim SM, dos Santos CB, Muller IL (2011) Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution. Corros Sci 53:1786–1793. doi:10.​1016/​j.​corsci.​2011.​01.​057 CrossRef
48.
Zurück zum Zitat Kumar S, Narayanan TSNS, Raman SGS, Seshadri SK (2010) Surface modification of CP-Ti to improve the fretting-corrosion resistance: thermal oxidation vs. anodizing. Mater Sci Eng C Mater Biol Appl 30:921–927. doi:10.1016/j.msec.2010.03.024 CrossRef Kumar S, Narayanan TSNS, Raman SGS, Seshadri SK (2010) Surface modification of CP-Ti to improve the fretting-corrosion resistance: thermal oxidation vs. anodizing. Mater Sci Eng C Mater Biol Appl 30:921–927. doi:10.​1016/​j.​msec.​2010.​03.​024 CrossRef
50.
Zurück zum Zitat Ratner BD, Hoffman AS, Schoen FJ, Lemon JE (2004) Biomaterials science: a multidisciplinary endeavor. An introduction to materials in medicine. Elsevier Academic Press, San Diego Ratner BD, Hoffman AS, Schoen FJ, Lemon JE (2004) Biomaterials science: a multidisciplinary endeavor. An introduction to materials in medicine. Elsevier Academic Press, San Diego
51.
Zurück zum Zitat Nakagawa M, Matsuya S, Shiraishi T, Ohta M (1999) Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use. J Dent Res 78:1568–1572CrossRef Nakagawa M, Matsuya S, Shiraishi T, Ohta M (1999) Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use. J Dent Res 78:1568–1572CrossRef
52.
Zurück zum Zitat Huang HH (2003) Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy. Biomaterials 24:275–282CrossRef Huang HH (2003) Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy. Biomaterials 24:275–282CrossRef
53.
Zurück zum Zitat Mabilleau G, Bourdon S, Joly-Guillou ML, Filmon R, Basle MF, Chappard D (2006) Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. Acta Biomater 2:121–129. doi:10.1016/j.actbio.2005.09.004 CrossRef Mabilleau G, Bourdon S, Joly-Guillou ML, Filmon R, Basle MF, Chappard D (2006) Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. Acta Biomater 2:121–129. doi:10.​1016/​j.​actbio.​2005.​09.​004 CrossRef
55.
Zurück zum Zitat Jones FH (2001) Teeth and bones: applications of surface science to dental materials and related biomaterials. Surf Sci Rep 42:79–205CrossRef Jones FH (2001) Teeth and bones: applications of surface science to dental materials and related biomaterials. Surf Sci Rep 42:79–205CrossRef
56.
Zurück zum Zitat Schiff N, Grosgogeat B, Lissac M, Dalard F (2002) Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials 23:1995–2002CrossRef Schiff N, Grosgogeat B, Lissac M, Dalard F (2002) Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials 23:1995–2002CrossRef
57.
Zurück zum Zitat Popa MV, Vasilescu E, Drob P, Vasilescu C, Demetrescu I, Ionita D (2008) Long-term assessment of the implant titanium material–artificial saliva interface. J Mater Sci Mater Med 19:1–9. doi:10.1007/s10856-007-3271-7 CrossRef Popa MV, Vasilescu E, Drob P, Vasilescu C, Demetrescu I, Ionita D (2008) Long-term assessment of the implant titanium material–artificial saliva interface. J Mater Sci Mater Med 19:1–9. doi:10.​1007/​s10856-007-3271-7 CrossRef
59.
Zurück zum Zitat Souza ME, Lima L, Lima CR, Zavaglia CA, Freire CM (2009) Effects of pH on the electrochemical behaviour of titanium alloys for implant applications. J Mater Sci Mater Med 20:549–552. doi:10.1007/s10856-008-3623-y CrossRef Souza ME, Lima L, Lima CR, Zavaglia CA, Freire CM (2009) Effects of pH on the electrochemical behaviour of titanium alloys for implant applications. J Mater Sci Mater Med 20:549–552. doi:10.​1007/​s10856-008-3623-y CrossRef
60.
Zurück zum Zitat Messer RL, Tackas G, Mickalonis J, Brown Y, Lewis JB, Wataha JC (2009) Corrosion of machined titanium dental implants under inflammatory conditions. J Biomed Mater Res B Appl Biomater 88:474–481. doi:10.1002/jbm.b.31162 CrossRef Messer RL, Tackas G, Mickalonis J, Brown Y, Lewis JB, Wataha JC (2009) Corrosion of machined titanium dental implants under inflammatory conditions. J Biomed Mater Res B Appl Biomater 88:474–481. doi:10.​1002/​jbm.​b.​31162 CrossRef
61.
Zurück zum Zitat Messer RL, Seta F, Mickalonis J, Brown Y, Lewis JB, Wataha JC (2010) Corrosion of phosphate-enriched titanium oxide surface dental implants (TiUnite) under in vitro inflammatory and hyperglycemic conditions. J Biomed Mater Res B Appl Biomater 92:525–534. doi:10.1002/jbm.b.31548 Messer RL, Seta F, Mickalonis J, Brown Y, Lewis JB, Wataha JC (2010) Corrosion of phosphate-enriched titanium oxide surface dental implants (TiUnite) under in vitro inflammatory and hyperglycemic conditions. J Biomed Mater Res B Appl Biomater 92:525–534. doi:10.​1002/​jbm.​b.​31548
62.
64.
Zurück zum Zitat Nakagawa M, Matsuya S, Udoh K (2002) Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys. Dent Mater J 21:83–92CrossRef Nakagawa M, Matsuya S, Udoh K (2002) Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys. Dent Mater J 21:83–92CrossRef
65.
Zurück zum Zitat Landolt D, Mischler S, Stemp M (2001) Electrochemical methods in tribocorrosion: a critical appraisal. Electrochim Acta 46:3913–3929CrossRef Landolt D, Mischler S, Stemp M (2001) Electrochemical methods in tribocorrosion: a critical appraisal. Electrochim Acta 46:3913–3929CrossRef
67.
Zurück zum Zitat van Loon JP, de Bont LG, Stegenga B, Spijkervet FK, Verkerke GJ (2002) Groningen temporomandibular joint prosthesis. Development and first clinical application. Int J Oral Maxillofac Surg 31:44–52. doi:10.1054/ijom.2001.0175 CrossRef van Loon JP, de Bont LG, Stegenga B, Spijkervet FK, Verkerke GJ (2002) Groningen temporomandibular joint prosthesis. Development and first clinical application. Int J Oral Maxillofac Surg 31:44–52. doi:10.​1054/​ijom.​2001.​0175 CrossRef
68.
Zurück zum Zitat Mercuri LG (2000) The use of alloplastic prostheses for temporomandibular joint reconstruction. J Oral Maxillofac Surg 58:70–75CrossRef Mercuri LG (2000) The use of alloplastic prostheses for temporomandibular joint reconstruction. J Oral Maxillofac Surg 58:70–75CrossRef
69.
Zurück zum Zitat Chaturvedi TP (2009) An overview of the corrosion aspect of dental implants (titanium and its alloys). Indian J Dent Res 20:91–98CrossRef Chaturvedi TP (2009) An overview of the corrosion aspect of dental implants (titanium and its alloys). Indian J Dent Res 20:91–98CrossRef
70.
Zurück zum Zitat Simon BI, Goldman HM, Ruben MP, Baker E (1969) The role of endotoxin in periodontal disease. I. A reproducible, quantitative method for determining the amount of endotoxin in human gingival exudate. J Periodontol 40:695–701CrossRef Simon BI, Goldman HM, Ruben MP, Baker E (1969) The role of endotoxin in periodontal disease. I. A reproducible, quantitative method for determining the amount of endotoxin in human gingival exudate. J Periodontol 40:695–701CrossRef
71.
Zurück zum Zitat Wilson M (1995) Biological activities of lipopolysaccharides from oral bacteria and their relevance to the pathogenesis of chronic periodontitis. Sci Prog 78(Pt 1):19–34 Wilson M (1995) Biological activities of lipopolysaccharides from oral bacteria and their relevance to the pathogenesis of chronic periodontitis. Sci Prog 78(Pt 1):19–34
72.
Zurück zum Zitat Knoernschild KL, Tompkins GR, Lefebvre CA, Griffiths LL, Schuster GS (1996) Effect of pH on Porphyromonas gingivalis endotoxin affinity for resins. Int J Prosthodont 9:239–247 Knoernschild KL, Tompkins GR, Lefebvre CA, Griffiths LL, Schuster GS (1996) Effect of pH on Porphyromonas gingivalis endotoxin affinity for resins. Int J Prosthodont 9:239–247
73.
Zurück zum Zitat Nelson SK, Knoernschild KL, Robinson FG, Schuster GS (1997) Lipopolysaccharide affinity for titanium implant biomaterials. J Prosthet Dent 77:76–82CrossRef Nelson SK, Knoernschild KL, Robinson FG, Schuster GS (1997) Lipopolysaccharide affinity for titanium implant biomaterials. J Prosthet Dent 77:76–82CrossRef
Metadaten
Titel
Fundamentals of Linking Tribology and Corrosion (Tribocorrosion) for Medical Applications: Bio-tribocorrosion
verfasst von
V. A. Barão
C. Sukotjo
M. T. Mathew
Copyright-Jahr
2013
Verlag
Springer New York
DOI
https://doi.org/10.1007/978-1-4614-1945-7_19

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.