Skip to main content

2020 | OriginalPaper | Buchkapitel

Glucose Sensing for Diabetes Monitoring: From Invasive to Wearable Device

verfasst von : Loubna Chhiba, Basma Zaher, Mustapha Sidqui, Abdelaziz Marzak

Erschienen in: Innovations in Smart Cities Applications Edition 3

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Blood glucose monitoring is considered the gold standard for diabetes diagnostics and self-monitoring. However, the underlying process is invasive and highly uncomfortable for patients. Furthermore, the process must be completed several times a day to successfully manage the disease, which greatly contributes to the massive need for non-invasive monitoring options. Human serums, such as saliva, sweat and tears contain traces of glucose and are easily accessible. It is very important for human health to rapidly and accurately detect glucose levels in biological environments, especially for diabetes mellitus. We proposed a simple, highly sensitive, accurate, convenient, low-cost, and disposable glucose biosensor on a single chip. Thus, this disposable biosensor will be an alternative for real time tracking of glucose levels from body fluids, e.g. saliva, in a noninvasive, pain-free, accurate, and continuous way.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Claussen, J.C., Kumar, A., Jaroch, D.B., Khawaja, M.H., Hibbard, A.B., Porterfield, D.M., Fisher, T.S.: Nanostructuring platinum nanoparticles on multilayered graphene petal nanosheets for electrochemical biosensing. Adv. Funct. Mater. 22, 3399–3405 (2012)CrossRef Claussen, J.C., Kumar, A., Jaroch, D.B., Khawaja, M.H., Hibbard, A.B., Porterfield, D.M., Fisher, T.S.: Nanostructuring platinum nanoparticles on multilayered graphene petal nanosheets for electrochemical biosensing. Adv. Funct. Mater. 22, 3399–3405 (2012)CrossRef
2.
Zurück zum Zitat Sensor detects glucose in saliva and tears for diabetes testing. Purdue University, 20 août 2012 Sensor detects glucose in saliva and tears for diabetes testing. Purdue University, 20 août 2012
3.
Zurück zum Zitat Villagrasa, J.P., Colomer-Farrarons, J., Miribel, P.L.: Bioelectronics for amperometric biosensors (2013) Villagrasa, J.P., Colomer-Farrarons, J., Miribel, P.L.: Bioelectronics for amperometric biosensors (2013)
4.
Zurück zum Zitat Makaram, P., Owens, D., Aceros, J.: Trends in nanomaterial-based non-invasive diabetes sensing technologies. Diagnostics 4, 27–46 (2014)CrossRef Makaram, P., Owens, D., Aceros, J.: Trends in nanomaterial-based non-invasive diabetes sensing technologies. Diagnostics 4, 27–46 (2014)CrossRef
5.
Zurück zum Zitat Corrie, S.J., Coffey, J.W., Islam, J., Markey, K.A., Kendall, M.A.F.: Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis. Analyst 140, 4350–4364 (2015)CrossRef Corrie, S.J., Coffey, J.W., Islam, J., Markey, K.A., Kendall, M.A.F.: Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis. Analyst 140, 4350–4364 (2015)CrossRef
6.
Zurück zum Zitat Yoo, E.H., Lee, S.Y.: Glucose biosensors: an overview of use in clinical practice. Sensors 10, 4558–4576 (2010)CrossRef Yoo, E.H., Lee, S.Y.: Glucose biosensors: an overview of use in clinical practice. Sensors 10, 4558–4576 (2010)CrossRef
7.
Zurück zum Zitat Coyle, S., Curto, V.F., Benito-Lopez, F., Florea, L., Diamond, D.: Wearable bio and chemical sensors. In: Wearable Sensors; Elsevier, Amsterdam (2014) Coyle, S., Curto, V.F., Benito-Lopez, F., Florea, L., Diamond, D.: Wearable bio and chemical sensors. In: Wearable Sensors; Elsevier, Amsterdam (2014)
8.
Zurück zum Zitat Clark Jr., L.C., Lyons, C.: Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 102, 29–45 (1962)CrossRef Clark Jr., L.C., Lyons, C.: Electrode systems for continuous monitoring in cardiovascular surgery. Ann. N. Y. Acad. Sci. 102, 29–45 (1962)CrossRef
9.
Zurück zum Zitat Newman, J.D., Turner, A.P.F.: Home blood glucose biosensors: a commercial perspective. Biosens. Bioelectron. 20, 2435–2453 (2005)CrossRef Newman, J.D., Turner, A.P.F.: Home blood glucose biosensors: a commercial perspective. Biosens. Bioelectron. 20, 2435–2453 (2005)CrossRef
10.
Zurück zum Zitat Bratlie, K.M., York, R.L., Invernale, M.A., Langer, R., Anderson, D.G.: Materials for diabetes therapeutics. Adv. Healthc. Mater. 1, 267–284 (2012)CrossRef Bratlie, K.M., York, R.L., Invernale, M.A., Langer, R., Anderson, D.G.: Materials for diabetes therapeutics. Adv. Healthc. Mater. 1, 267–284 (2012)CrossRef
11.
Zurück zum Zitat Do Amaral, C.E.F., Wolf, B.: Current development in non-invasive glucose monitoring. Med. Eng. Phys. 30, 541–549 (2008)CrossRef Do Amaral, C.E.F., Wolf, B.: Current development in non-invasive glucose monitoring. Med. Eng. Phys. 30, 541–549 (2008)CrossRef
12.
Zurück zum Zitat Saraoğlu, H.M., Koçan, M.: A study on non-invasive detection of blood glucose concentration from human palm perspiration by using artificial neural networks. Expert Syst. 27, 156–165 (2010)CrossRef Saraoğlu, H.M., Koçan, M.: A study on non-invasive detection of blood glucose concentration from human palm perspiration by using artificial neural networks. Expert Syst. 27, 156–165 (2010)CrossRef
13.
Zurück zum Zitat Gao, W., Emaminejad, S., Nyein, H.Y.Y., Challa, S., Chen, K., Peck, A., Fahad, H.M., Ota, H., Shiraki, H., Kiriya, D., Lien, D.H., Brooks, G.A., Davis, R.W., Javey, A.: Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature 529, 509 (2016)CrossRef Gao, W., Emaminejad, S., Nyein, H.Y.Y., Challa, S., Chen, K., Peck, A., Fahad, H.M., Ota, H., Shiraki, H., Kiriya, D., Lien, D.H., Brooks, G.A., Davis, R.W., Javey, A.: Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature 529, 509 (2016)CrossRef
14.
Zurück zum Zitat Lee, H., Choi, T.K., Lee, Y.B., Cho, H.R., Ghaffari, R., Wang, L., Choi, H.J., Chung, T.D., Lu, N., Hyeon, T., Choi, S.H., Kim, D.-H.: A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy. Nat. Nanotechnol. 11, 566 (2016)CrossRef Lee, H., Choi, T.K., Lee, Y.B., Cho, H.R., Ghaffari, R., Wang, L., Choi, H.J., Chung, T.D., Lu, N., Hyeon, T., Choi, S.H., Kim, D.-H.: A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy. Nat. Nanotechnol. 11, 566 (2016)CrossRef
15.
Zurück zum Zitat Lee, H., Song, C., Hong, Y.S., Kim, M.S., Cho, H.R., Kang, T., Shin, K., Choi, S.H., Hyeon, T., Kim, D.-H.: Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module. Sci. Adv. 3, e1601314 (2017)CrossRef Lee, H., Song, C., Hong, Y.S., Kim, M.S., Cho, H.R., Kang, T., Shin, K., Choi, S.H., Hyeon, T., Kim, D.-H.: Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module. Sci. Adv. 3, e1601314 (2017)CrossRef
16.
Zurück zum Zitat Yan, Q., Peng, B., Su, G., Cohan, B.E., Major, T.C., Meyerhoff, M.E.: Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration. Anal. Chem. 83, 8341–8346 (2011)CrossRef Yan, Q., Peng, B., Su, G., Cohan, B.E., Major, T.C., Meyerhoff, M.E.: Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration. Anal. Chem. 83, 8341–8346 (2011)CrossRef
17.
Zurück zum Zitat Zhang, J., Hodge, W., Hutnick, C., Wang, X.: Noninvasive diagnostic devices for diabetes through measuring tear glucose. J. Diabetes Sci. Technol. 5, 166–172 (2011)CrossRef Zhang, J., Hodge, W., Hutnick, C., Wang, X.: Noninvasive diagnostic devices for diabetes through measuring tear glucose. J. Diabetes Sci. Technol. 5, 166–172 (2011)CrossRef
18.
Zurück zum Zitat Kim, J., Kim, M., Lee, M.S., Kim, K., Ji, S., Kim, Y.T., Park, J., Na, K., Bae, K.H., Kyun Kim, H., Bien, F., Young Lee, C., Park, J.U.: Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics. Nat. Commun. 8, 14997 (2017)CrossRef Kim, J., Kim, M., Lee, M.S., Kim, K., Ji, S., Kim, Y.T., Park, J., Na, K., Bae, K.H., Kyun Kim, H., Bien, F., Young Lee, C., Park, J.U.: Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics. Nat. Commun. 8, 14997 (2017)CrossRef
19.
Zurück zum Zitat Falk, M., Andoralov, V., Silow, M., Toscano, M.D., Shleev, S.: Miniature biofuel cell as a potential power source for glucose-sensing contact lenses. Anal. Chem. 85, 6342–6348 (2013)CrossRef Falk, M., Andoralov, V., Silow, M., Toscano, M.D., Shleev, S.: Miniature biofuel cell as a potential power source for glucose-sensing contact lenses. Anal. Chem. 85, 6342–6348 (2013)CrossRef
20.
Zurück zum Zitat Kim, J., Imani, S., de Araujo, W.R., Warchall, J., Valdes-Ramirez, G., Paixao, T.R., Mercier, P.P., Wang, J.: Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosens. Bioelectron. 74, 1061–1068 (2015)CrossRef Kim, J., Imani, S., de Araujo, W.R., Warchall, J., Valdes-Ramirez, G., Paixao, T.R., Mercier, P.P., Wang, J.: Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosens. Bioelectron. 74, 1061–1068 (2015)CrossRef
21.
Zurück zum Zitat Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., Mitsubayashi, K.: Mouthguard biosensor with telemetry system for monitoring of saliva glucose: a novel cavitas sensor. Biosens. Bioelectron. 84, 106–111 (2016)CrossRef Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., Mitsubayashi, K.: Mouthguard biosensor with telemetry system for monitoring of saliva glucose: a novel cavitas sensor. Biosens. Bioelectron. 84, 106–111 (2016)CrossRef
22.
Zurück zum Zitat Zhang, W., Du, Y., Wang, M.L.: Noninvasive glucose monitoring using saliva nano-biosensor. Sens. Biosens. Res. 4, 23 (2015) Zhang, W., Du, Y., Wang, M.L.: Noninvasive glucose monitoring using saliva nano-biosensor. Sens. Biosens. Res. 4, 23 (2015)
23.
Zurück zum Zitat Du, Y., Zhang, W., Wang, M.L.: Sensing of salivary glucose using nano-structured biosensors. Biosensors 6, 10 (2016)CrossRef Du, Y., Zhang, W., Wang, M.L.: Sensing of salivary glucose using nano-structured biosensors. Biosensors 6, 10 (2016)CrossRef
24.
Zurück zum Zitat Zhang, M., Liao, C., Mak, C.H., You, P., Mak, C.L., Yan, F.: Highly sensitive glucose sensors based on enzyme-modified whole-graphene solution-gated transistors. Sci. Rep. 5, 8311 (2015)CrossRef Zhang, M., Liao, C., Mak, C.H., You, P., Mak, C.L., Yan, F.: Highly sensitive glucose sensors based on enzyme-modified whole-graphene solution-gated transistors. Sci. Rep. 5, 8311 (2015)CrossRef
25.
Zurück zum Zitat Food and Drug Administration: Glucowatch for diabetes. WHO Drug Inf. 16, 1 (2002) Food and Drug Administration: Glucowatch for diabetes. WHO Drug Inf. 16, 1 (2002)
26.
Zurück zum Zitat American Diabetes Association: Diagnosis and classification of diabetes mellitus. Diabetes Care 27, 5–10 (2004)CrossRef American Diabetes Association: Diagnosis and classification of diabetes mellitus. Diabetes Care 27, 5–10 (2004)CrossRef
27.
Zurück zum Zitat Sabokdast, M., Habibi-Rezaei, M., Moosavi-Movahedi, A.A., Ferdousi, M., Azimzadeh-Irani, E., Poursasan, N.: Protection by beta-hydroxybutyric acid against insulin glycation, lipid peroxidation and microglial cell apoptosis. DARU J. Pharm. Sci. 23, 42 (2015)CrossRef Sabokdast, M., Habibi-Rezaei, M., Moosavi-Movahedi, A.A., Ferdousi, M., Azimzadeh-Irani, E., Poursasan, N.: Protection by beta-hydroxybutyric acid against insulin glycation, lipid peroxidation and microglial cell apoptosis. DARU J. Pharm. Sci. 23, 42 (2015)CrossRef
28.
Zurück zum Zitat Coster, S., Gulliford, M.C., Seed, P.T., Powrie, J.K., Swaminathan, R.: Monitoring blood glucose control in diabetes mellitus: a systematic review. Health Technol. Assess 4, i–iv, 1–93 (2000) Coster, S., Gulliford, M.C., Seed, P.T., Powrie, J.K., Swaminathan, R.: Monitoring blood glucose control in diabetes mellitus: a systematic review. Health Technol. Assess 4, i–iv, 1–93 (2000)
31.
Zurück zum Zitat Toghill, K.E., Compton, R.G.: Electrochemical non-enzymatic glucose sensors: a perspective and an evaluation. Int. J. Electrochem. Sci. 5, 1246–1301 (2010) Toghill, K.E., Compton, R.G.: Electrochemical non-enzymatic glucose sensors: a perspective and an evaluation. Int. J. Electrochem. Sci. 5, 1246–1301 (2010)
Metadaten
Titel
Glucose Sensing for Diabetes Monitoring: From Invasive to Wearable Device
verfasst von
Loubna Chhiba
Basma Zaher
Mustapha Sidqui
Abdelaziz Marzak
Copyright-Jahr
2020
DOI
https://doi.org/10.1007/978-3-030-37629-1_27

    Premium Partner