Abstract

Tests with high impulse currents are performed to simulate the stress of power apparatus in the high-voltage grid caused by lightning and short circuits. Various impulse test currents and the corresponding measurement methods are standardized in IEC 62475, together with DC and AC currents. Impulse currents with peak values of up to several 100 kA are generated in the test laboratory, using capacitive energy storage units which are charged slowly and then discharged abruptly to the test object via an RC network. For the conventional measurement of impulse currents up to the highest current magnitudes, low-ohmic measuring resistors or magnetic coils with and without magnetic core are used together with digital recorders, enabling computer-assisted evaluation of the impulse parameters. A well-founded measurement technique is essential, which is achieved mainly by comparison measurement of the current measuring system with a reference system. One of the important properties of a current sensor is its step response, which characterizes the transfer behavior. Numerical convolution can be used for improving the dynamic behavior of a current measuring system.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Gamlin, M.: Impulse current testing. In: Proceedings of 14th ISH Beijing, Paper J-09 (2005) Gamlin, M.: Impulse current testing. In: Proceedings of 14th ISH Beijing, Paper J-09 (2005)
2.
Zurück zum Zitat Modrusan, M.: Normierte Berechnung von Stoßstromkreisen für vorgegebene Impulsströme. Bull. SEV 67, 1237–1242 (1976) Modrusan, M.: Normierte Berechnung von Stoßstromkreisen für vorgegebene Impulsströme. Bull. SEV 67, 1237–1242 (1976)
3.
Zurück zum Zitat Schwab, A., Imo, F.: Berechnung von Stoßstromkreisen für Exponentialströme. Bull. SEV/VSE 68, 1310–1313 (1977) Schwab, A., Imo, F.: Berechnung von Stoßstromkreisen für Exponentialströme. Bull. SEV/VSE 68, 1310–1313 (1977)
4.
Zurück zum Zitat Kuzhekin, I.P., Hribar, Z.: Imitator of lightning currents with amplitudes of 200 kA. In: Proceedings of 13th ISH Delft (2003) Kuzhekin, I.P., Hribar, Z.: Imitator of lightning currents with amplitudes of 200 kA. In: Proceedings of 13th ISH Delft (2003)
5.
Zurück zum Zitat Körbler, B., Pack, S.: Analysis of an impulse current generator. In: Proceedings of 12th ISH Bangalore, Paper 7–22 (2001) Körbler, B., Pack, S.: Analysis of an impulse current generator. In: Proceedings of 12th ISH Bangalore, Paper 7–22 (2001)
6.
Zurück zum Zitat Zhao, G., Zang, X.: EMTP analysis of impulse voltage generator circuit. In: Proceedings of 14th ISH Beijing, Paper A-11 (2005) Zhao, G., Zang, X.: EMTP analysis of impulse voltage generator circuit. In: Proceedings of 14th ISH Beijing, Paper A-11 (2005)
7.
Zurück zum Zitat Zischank, W.: A surge current generator with a double-crowbar spark gap for the simulation of direct lightning stroke effects. In: Proceedings of 5th ISH Braunschweig, Paper 61.07 (1987) Zischank, W.: A surge current generator with a double-crowbar spark gap for the simulation of direct lightning stroke effects. In: Proceedings of 5th ISH Braunschweig, Paper 61.07 (1987)
8.
Zurück zum Zitat Pietsch, R., Baronick, M., Kubat, M.: Impulse current test system with crowbar gap extension for surge arrester testing. In: Proceedings of 15th ISH Ljubljana, Paper T10-745 (2007) Pietsch, R., Baronick, M., Kubat, M.: Impulse current test system with crowbar gap extension for surge arrester testing. In: Proceedings of 15th ISH Ljubljana, Paper T10-745 (2007)
9.
Zurück zum Zitat Salge, J., Peier, D., Brilka, R., Schneider, D.: Application of inductive energy storage for the production of intense magnetic fields. In: 6th Symposium on Fusion Technology, Aachen (1970) Salge, J., Peier, D., Brilka, R., Schneider, D.: Application of inductive energy storage for the production of intense magnetic fields. In: 6th Symposium on Fusion Technology, Aachen (1970)
10.
Zurück zum Zitat Kind, D., Salge, J., Schiweck, L., Newi, G.: Explodierende Drähte zur Erzeugung von Megavolt-Impulsen in Hochspannungsprüfkreisen. ETZ-A 92, 46–51 (1971) Kind, D., Salge, J., Schiweck, L., Newi, G.: Explodierende Drähte zur Erzeugung von Megavolt-Impulsen in Hochspannungsprüfkreisen. ETZ-A 92, 46–51 (1971)
11.
Zurück zum Zitat Feser, K., Modrusan, M., Sutter, H.: Simulation of multiple lightning strokes in laboratory. In: Proceedings of 3rd ISH Mailand, Paper 41.05 (1979) Feser, K., Modrusan, M., Sutter, H.: Simulation of multiple lightning strokes in laboratory. In: Proceedings of 3rd ISH Mailand, Paper 41.05 (1979)
12.
Zurück zum Zitat Klein, T., Köhler, W., Feser, K.: Exponential current generator for multiple pulses. In: Proceedings of 12th ISH Bangalore, Paper 7-21 (2001) Klein, T., Köhler, W., Feser, K.: Exponential current generator for multiple pulses. In: Proceedings of 12th ISH Bangalore, Paper 7-21 (2001)
13.
Zurück zum Zitat Modrusan, M.: Langzeit-Stoßstromgenerator für die Ableiterprüfung gemäß CEI-Empfehlung. Bull. SEV 68, 1304–1309 (1977) Modrusan, M.: Langzeit-Stoßstromgenerator für die Ableiterprüfung gemäß CEI-Empfehlung. Bull. SEV 68, 1304–1309 (1977)
14.
Zurück zum Zitat Park, E.H.: Shunts and inductors for current measurements. NBS J. Res. 39, 191–212 (1947) Park, E.H.: Shunts and inductors for current measurements. NBS J. Res. 39, 191–212 (1947)
15.
Zurück zum Zitat Navarro, A., et al.: Transducer for lightning current measurement. In: Proceedings of 14th ISH Beijing, Paper B-29 (2005) Navarro, A., et al.: Transducer for lightning current measurement. In: Proceedings of 14th ISH Beijing, Paper B-29 (2005)
16.
Zurück zum Zitat Schwab, A.J.: Die Berechnung der Bandbreite und der Anstiegszeit rohrförmiger Messwiderstände unter Berücksichtigung der Stromverdrängung. ETZ A 89, 604–606 (1968) Schwab, A.J.: Die Berechnung der Bandbreite und der Anstiegszeit rohrförmiger Messwiderstände unter Berücksichtigung der Stromverdrängung. ETZ A 89, 604–606 (1968)
17.
Zurück zum Zitat Schwab, A.J.: Low-resistance shunts for impulse currents. IEEE Trans. PAS 90, 2251–2257 (1971)CrossRef Schwab, A.J.: Low-resistance shunts for impulse currents. IEEE Trans. PAS 90, 2251–2257 (1971)CrossRef
18.
Zurück zum Zitat Pfeiffer, W.: Aufbau und Überprüfung von koaxialen Rohrwiderständen sehr kurzer Anstiegszeit. ETZ-A 91, 59–60 (1970) Pfeiffer, W.: Aufbau und Überprüfung von koaxialen Rohrwiderständen sehr kurzer Anstiegszeit. ETZ-A 91, 59–60 (1970)
19.
Zurück zum Zitat Wakimoto, T., Ishii, M.: Step response and comparison test of impulse current measuring system. In: Proceedings of 18th ISH Seoul, Paper PC-10 (2013) Wakimoto, T., Ishii, M.: Step response and comparison test of impulse current measuring system. In: Proceedings of 18th ISH Seoul, Paper PC-10 (2013)
20.
Zurück zum Zitat Nagel, A., Kerwer, T.: Design of a 1 kA pulsed current source with 60 ns rise time for the analysis of current probes. In: Proceedings of PCIM Europe Nürnberg, pp. 899–902 (2004) Nagel, A., Kerwer, T.: Design of a 1 kA pulsed current source with 60 ns rise time for the analysis of current probes. In: Proceedings of PCIM Europe Nürnberg, pp. 899–902 (2004)
21.
Zurück zum Zitat Högberg, L.: 1 Gc/s bandwidth shunt for measurements of current transients in the 10 A–10 kA range. J. Sci. Instrum. 42, 273–279 (1965)CrossRef Högberg, L.: 1 Gc/s bandwidth shunt for measurements of current transients in the 10 A–10 kA range. J. Sci. Instrum. 42, 273–279 (1965)CrossRef
22.
Zurück zum Zitat Wesner, F.: Koaxiale Flächenwiderstände zur Messung hoher Stoßströme mit extrem kurzer Anstiegszeit. ETZ-A 91, 521–524 (1970) Wesner, F.: Koaxiale Flächenwiderstände zur Messung hoher Stoßströme mit extrem kurzer Anstiegszeit. ETZ-A 91, 521–524 (1970)
23.
Zurück zum Zitat Witt, H.: Response of low ohmic resistance shunts for impulse currents. Elteknik 3, 45–47 (1960) Witt, H.: Response of low ohmic resistance shunts for impulse currents. Elteknik 3, 45–47 (1960)
24.
Zurück zum Zitat Lappe, F., Westendorf, K.B.: Ein Meß-Widerstand für Hochfrequenz. Z. Angew. Phys. 3, 29–32 (1951) Lappe, F., Westendorf, K.B.: Ein Meß-Widerstand für Hochfrequenz. Z. Angew. Phys. 3, 29–32 (1951)
25.
Zurück zum Zitat Malewski, R.: New device for current measurement in exploding wire circuits. Rev. Sci. Instr. 39, 90–94 (1968)CrossRef Malewski, R.: New device for current measurement in exploding wire circuits. Rev. Sci. Instr. 39, 90–94 (1968)CrossRef
26.
Zurück zum Zitat Malewski, R.: Micro-Ohm shunts for precise recording of short-circuit currents. IEEE Trans. PAS 96, 579–585 (1977)CrossRef Malewski, R.: Micro-Ohm shunts for precise recording of short-circuit currents. IEEE Trans. PAS 96, 579–585 (1977)CrossRef
27.
Zurück zum Zitat Malewski, R., Nguyen, Chinh T., Feser, K., Hyltén-Cavallius, N.: Elimination of the skin effect error in heavy-current shunts. IEEE Trans. PAS 100, 1333–1340 (1981)CrossRef Malewski, R., Nguyen, Chinh T., Feser, K., Hyltén-Cavallius, N.: Elimination of the skin effect error in heavy-current shunts. IEEE Trans. PAS 100, 1333–1340 (1981)CrossRef
28.
Zurück zum Zitat Schwab, A., Imo, F.: Übergangsverhalten koaxialer Strommesswiderstände mit exzentrischem Spannungsabgriff. ETZ A-Arch. 2, 95–100 (1980) Schwab, A., Imo, F.: Übergangsverhalten koaxialer Strommesswiderstände mit exzentrischem Spannungsabgriff. ETZ A-Arch. 2, 95–100 (1980)
29.
Zurück zum Zitat Lu, L., Mou, L., Liu, J., Li, Y.: Development of a standardizing device for Rogowski coil. In: Proceedings of 14th ISH Beijing, Paper J-48 (2005) Lu, L., Mou, L., Liu, J., Li, Y.: Development of a standardizing device for Rogowski coil. In: Proceedings of 14th ISH Beijing, Paper J-48 (2005)
30.
Zurück zum Zitat Rogowski, W.: Über einige Anwendungen des magnetischen Spannungsmessers. Arch. Elektrotech. 1, 511–527 (1913)CrossRef Rogowski, W.: Über einige Anwendungen des magnetischen Spannungsmessers. Arch. Elektrotech. 1, 511–527 (1913)CrossRef
31.
Zurück zum Zitat Destefan, D.E., Ramboz, J.D.: Advancements in high current measurement and calibration. In: NCSL Intern. Workshop and Symposium, Toronto (2000) Destefan, D.E., Ramboz, J.D.: Advancements in high current measurement and calibration. In: NCSL Intern. Workshop and Symposium, Toronto (2000)
32.
Zurück zum Zitat Ward, D.A., Exon, J.L.T.: Using Rogowski coils for transient current measurements. IEE Eng. Sci. Educ. J. 2, 105–113 (1993)CrossRef Ward, D.A., Exon, J.L.T.: Using Rogowski coils for transient current measurements. IEE Eng. Sci. Educ. J. 2, 105–113 (1993)CrossRef
33.
Zurück zum Zitat Ray, W.F., Hewson, C.R.: High performance Rogowski current transducers. In: Conference Proceedings of IEEE-IAS Conference, Rome (2000) Ray, W.F., Hewson, C.R.: High performance Rogowski current transducers. In: Conference Proceedings of IEEE-IAS Conference, Rome (2000)
34.
Zurück zum Zitat Kojovic, L.: PCB Rogowski coils benefit relay protection. IEEE Comput. Appl. Power 15, 1–4 (2002)CrossRef Kojovic, L.: PCB Rogowski coils benefit relay protection. IEEE Comput. Appl. Power 15, 1–4 (2002)CrossRef
35.
Zurück zum Zitat Schon, K., Schuppel, W.: Precision Rogowski coil used with numerical integration. In: Proceedings of 13th ISH Ljubljana, Paper T10-130 (2007) Schon, K., Schuppel, W.: Precision Rogowski coil used with numerical integration. In: Proceedings of 13th ISH Ljubljana, Paper T10-130 (2007)
36.
Zurück zum Zitat Hewson, C.R., Ray, W.F.: Optimising the high frequency bandwidth and immunity to interference of Rogowski coils in measurement applications with large local dV/dt. In: Conference Proceedings of IEEE-APEC Conference, Palm Springs (2010) Hewson, C.R., Ray, W.F.: Optimising the high frequency bandwidth and immunity to interference of Rogowski coils in measurement applications with large local dV/dt. In: Conference Proceedings of IEEE-APEC Conference, Palm Springs (2010)
37.
Zurück zum Zitat Cooper, J.: On the high-frequency response of a Rogowski coil. J. Nucl. Energy Part C 5, 285–289 (1963)CrossRef Cooper, J.: On the high-frequency response of a Rogowski coil. J. Nucl. Energy Part C 5, 285–289 (1963)CrossRef
38.
Zurück zum Zitat Bellm, H., Küchler, A., Herold, J., Schwab, A.: Rogowski-Spulen und Magnetfeldsensoren zur Messung transienter Ströme im Nanosekundenbereich. Arch. Elektrotechn. 68, part 1, 63–74, part 2, 69–74 (1985)CrossRef Bellm, H., Küchler, A., Herold, J., Schwab, A.: Rogowski-Spulen und Magnetfeldsensoren zur Messung transienter Ströme im Nanosekundenbereich. Arch. Elektrotechn. 68, part 1, 63–74, part 2, 69–74 (1985)CrossRef
39.
Zurück zum Zitat Anderson, J.M.: Wide frequency range current transformers. Rev. Sci. Instrum. 42, 915–926 (1971)CrossRef Anderson, J.M.: Wide frequency range current transformers. Rev. Sci. Instrum. 42, 915–926 (1971)CrossRef
40.
Zurück zum Zitat Waters, C.: Current transformers provide accurate, isolated measurements. In: Conference PCIM (1986) Waters, C.: Current transformers provide accurate, isolated measurements. In: Conference PCIM (1986)
41.
Zurück zum Zitat Schon, K., Mohns, E., Gheorghe, A.: Calibration of ferromagnetic coils used for impulse current measurements. In: Proceedings of 12th ISH Bangalore, vol. 5, 166–1169 (2001) Schon, K., Mohns, E., Gheorghe, A.: Calibration of ferromagnetic coils used for impulse current measurements. In: Proceedings of 12th ISH Bangalore, vol. 5, 166–1169 (2001)
42.
Zurück zum Zitat Di Capua, M.S.: High speed magnetic field and current measurements. In: NATO ASI Series E Applied Sciences, vol. 1, issue 108, 223–262 (1986)CrossRef Di Capua, M.S.: High speed magnetic field and current measurements. In: NATO ASI Series E Applied Sciences, vol. 1, issue 108, 223–262 (1986)CrossRef
43.
Zurück zum Zitat Krauß, T., Köhler, W., Feser, K.: Improved high bandwidth potential-free magnetic field probe for the measurement of transient magnetic fields. In: Proceedings of 11th ISH London, Paper 467 (1999) Krauß, T., Köhler, W., Feser, K.: Improved high bandwidth potential-free magnetic field probe for the measurement of transient magnetic fields. In: Proceedings of 11th ISH London, Paper 467 (1999)
44.
Zurück zum Zitat Kull, M., Krauß, T., Köhler, W., Feser, K.: High bandwidth 3D-magnetic field probe for the measurement of transient magnetic fields. In: Proceedings of 12th ISH Bangalore, Paper 1–16 (2001) Kull, M., Krauß, T., Köhler, W., Feser, K.: High bandwidth 3D-magnetic field probe for the measurement of transient magnetic fields. In: Proceedings of 12th ISH Bangalore, Paper 1–16 (2001)
Metadaten
Titel
High Impulse Currents
verfasst von
Klaus Schon
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-030-21770-9_5