Skip to main content

2019 | OriginalPaper | Buchkapitel

Impedimetric Method to Monitor Biological Layer Formation on Central Venous Catheters for Hemodialysis Made of Carbothane

verfasst von : Ewa Paradowska, Marta Nycz, Katarzyna Arkusz, Bartosz Kudliński, Elżbieta Krasicka-Cydzik

Erschienen in: Biomechanics in Medicine and Biology

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The aim of the study was to specify by an impedimetric method the changes observed on the inner wall of central venous catheters for hemodialysis leading to the formation of a biological film. To evaluate these changes a patient-dialyzer model was built in which experimental parameters were kept closely similar to the clinical conditions of hemodialysis. The impedance spectra and SEM/EDS analysis of the biological layer deposited on the inner surface of the distal part of the catheter gave an insight into the structure of film formation and its chemical composition. Since an early detection of biofilm formation inside the distal part of the catheter is crucial for the safety of medical treatment and it usually prompts the implementation of antibiotic therapy. Developed impedimetric method can minimize the risk of infection and ensure the continuity of treatment.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Saxena, A.K., Panhotra, B.R.: Haemodialysis catheter-related bloodstream infections: current treatment options and strategies for prevention. Swiss Med. Wkly. 127–138 (2005) Saxena, A.K., Panhotra, B.R.: Haemodialysis catheter-related bloodstream infections: current treatment options and strategies for prevention. Swiss Med. Wkly. 127–138 (2005)
5.
Zurück zum Zitat Tsukashita, M., Anda, A., Balsam, L.: Type A aortic dissection: a rare complication of central venous catheter placement. J. Card. Surg. 29, 368–370 (2014)CrossRef Tsukashita, M., Anda, A., Balsam, L.: Type A aortic dissection: a rare complication of central venous catheter placement. J. Card. Surg. 29, 368–370 (2014)CrossRef
7.
Zurück zum Zitat Raad, I., Hanna, H., Maki, D.: Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lan. Infect. Dis. 7, 645–657 (2007)CrossRef Raad, I., Hanna, H., Maki, D.: Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lan. Infect. Dis. 7, 645–657 (2007)CrossRef
9.
Zurück zum Zitat Menglin, T., Mei, F., Lijun, C., Jinmei, Z., Peng, K., Shuhua, L.: Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery. Crit. Care Nurse 5, 53–61 (2014) Menglin, T., Mei, F., Lijun, C., Jinmei, Z., Peng, K., Shuhua, L.: Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery. Crit. Care Nurse 5, 53–61 (2014)
10.
Zurück zum Zitat Horvath, R., Collignon, P.: Controlling intravascular catheter infections. Aust. Prescr. 26, 41–43 (2003)CrossRef Horvath, R., Collignon, P.: Controlling intravascular catheter infections. Aust. Prescr. 26, 41–43 (2003)CrossRef
11.
Zurück zum Zitat Elliott, T.S.J.: The pathogensis and prevention of intervascular catheter infections Central Venous Catheters. Lancet Infect. Dis. 206-215 (2009) Elliott, T.S.J.: The pathogensis and prevention of intervascular catheter infections Central Venous Catheters. Lancet Infect. Dis. 206-215 (2009)
12.
Zurück zum Zitat Cornelis van Rooden, J., Schippers, E.F., Rosendaal, F.R., Meinders, A.E., Huisman, M.V.: Infectious complications of central venous catheters increase the risk of catheter-related thrombosis in hematology patients: a prospective study. J. Clin. Oncol. 23, 2655–2660 (2005). https://doi.org/10.1200/JCO.2005.05.002CrossRef Cornelis van Rooden, J., Schippers, E.F., Rosendaal, F.R., Meinders, A.E., Huisman, M.V.: Infectious complications of central venous catheters increase the risk of catheter-related thrombosis in hematology patients: a prospective study. J. Clin. Oncol. 23, 2655–2660 (2005). https://​doi.​org/​10.​1200/​JCO.​2005.​05.​002CrossRef
15.
Zurück zum Zitat Maczynska, B., Przondo-Mordarska, A.: Bloodstream infections related to venous access. Zakazenia, p. 4 (2011) Maczynska, B., Przondo-Mordarska, A.: Bloodstream infections related to venous access. Zakazenia, p. 4 (2011)
17.
Zurück zum Zitat Kutner, D.J.: Thrombotic complications of centra venous catheters in cancer patients. Oncologist 9, 207–216 (2004)CrossRef Kutner, D.J.: Thrombotic complications of centra venous catheters in cancer patients. Oncologist 9, 207–216 (2004)CrossRef
20.
Zurück zum Zitat Kingdon, E.J., et al.: Atrial thrombus and central venous dialysis catheters. Am. J. Kidney Dis. 38, 631–639 (2001)CrossRef Kingdon, E.J., et al.: Atrial thrombus and central venous dialysis catheters. Am. J. Kidney Dis. 38, 631–639 (2001)CrossRef
22.
Zurück zum Zitat Paredes, J., Becerro, S., Arizti, F., Aguinaga, A., Del Pozo, J.L., Arana, S.: Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system. Biosens. Bioelectron. 38, 226–232 (2012)CrossRef Paredes, J., Becerro, S., Arizti, F., Aguinaga, A., Del Pozo, J.L., Arana, S.: Real time monitoring of the impedance characteristics of Staphylococcal bacterial biofilm cultures with a modified CDC reactor system. Biosens. Bioelectron. 38, 226–232 (2012)CrossRef
26.
Zurück zum Zitat Wei, H., Ding, D., Wei, S., Guo, Z.: Anticorrosive conductive polyurethane multiwalled carbon nanotube nanocomposites. J. Mater. Chem. 45, 10805–10813 (2013)CrossRef Wei, H., Ding, D., Wei, S., Guo, Z.: Anticorrosive conductive polyurethane multiwalled carbon nanotube nanocomposites. J. Mater. Chem. 45, 10805–10813 (2013)CrossRef
27.
Zurück zum Zitat Ookubo, A., Nishida, M., Ooi, K., Ishida, K., Hashimura, Y., Ikawa, A., Yoshimura, Y., Kawada, J.: Mechanism of phosphate adsorption to a three-dimensional structure of boehmite in the presence of bovine serum albumin. J. Pharm. Sci. 82, 744–749 (1993)CrossRef Ookubo, A., Nishida, M., Ooi, K., Ishida, K., Hashimura, Y., Ikawa, A., Yoshimura, Y., Kawada, J.: Mechanism of phosphate adsorption to a three-dimensional structure of boehmite in the presence of bovine serum albumin. J. Pharm. Sci. 82, 744–749 (1993)CrossRef
29.
Zurück zum Zitat Moradi, M., Yeganeh, H., Pazokifard, S.: Synthesis and assessment of novel anticorrosive polyurethane coatings containing an amine-functionalized nanoclay additive prepared by the cathodic electrophoretic deposition method. RSC Adv. 6, 28089–28102 (2016). https://doi.org/10.1039/C5RA26609BCrossRef Moradi, M., Yeganeh, H., Pazokifard, S.: Synthesis and assessment of novel anticorrosive polyurethane coatings containing an amine-functionalized nanoclay additive prepared by the cathodic electrophoretic deposition method. RSC Adv. 6, 28089–28102 (2016). https://​doi.​org/​10.​1039/​C5RA26609BCrossRef
30.
Zurück zum Zitat Mohsen, Q., SFadl-allah, S.A., El-Shenawy, N.S.: Electrochemical impedance spectroscopy study of the adsorption behavior of bovine serum albumin at biomimetic calcium - phosphate coating. Int. J. Electrochem. Sc. 7, 4510–4527 (2012) Mohsen, Q., SFadl-allah, S.A., El-Shenawy, N.S.: Electrochemical impedance spectroscopy study of the adsorption behavior of bovine serum albumin at biomimetic calcium - phosphate coating. Int. J. Electrochem. Sc. 7, 4510–4527 (2012)
31.
Zurück zum Zitat Vlasova, I., Saletsky, A.: Study of the denaturation of human serum albumin by sodium dodecyl sulfate using the intrinsic fluorescence of albumin. J. App. Spectrosc. 76, 536–541 (2009)CrossRef Vlasova, I., Saletsky, A.: Study of the denaturation of human serum albumin by sodium dodecyl sulfate using the intrinsic fluorescence of albumin. J. App. Spectrosc. 76, 536–541 (2009)CrossRef
Metadaten
Titel
Impedimetric Method to Monitor Biological Layer Formation on Central Venous Catheters for Hemodialysis Made of Carbothane
verfasst von
Ewa Paradowska
Marta Nycz
Katarzyna Arkusz
Bartosz Kudliński
Elżbieta Krasicka-Cydzik
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-319-97286-2_4