Skip to main content

2017 | OriginalPaper | Buchkapitel

Influence of Exoskeleton Parameters Calibration Inaccuracies on the Step Length Error

verfasst von : Rafał Kabaciński, Mateusz Kowalski, Piotr Kaczmarek

Erschienen in: Automation 2017

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

While exoskeletons for paraplegic users are used nowadays only in laboratory environments for therapy, their use in less orderly environments or for climbing stairs is still troublesome for operators. One of the factors is the high step length variance. In this paper, the analysis of the influence of exoskeleton parameters calibration inaccuracies on the sagittal step length error in regard to the different dimensions and programmed step lengths is performed on CIE Exoskeleton kinematic model. Results show that the exoskeleton parameters calibration inaccuracies have a significant influence on the step length error. The exoskeleton segments lengths, have to be measured with at least millimeter accuracy, and special care is advised in case of the rigidity of the back segment of the exoskeleton.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Contreras-Vidal, J.L., Bhagat, N.A., Brantley, J., Cruz-Garza, J.G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S.H., Zhu, F., Pons, J.L.: Powered exoskeletons for bipedal locomotion after spinal cord injury. J. Neural Eng. 13(3), 031001 (2016)CrossRef Contreras-Vidal, J.L., Bhagat, N.A., Brantley, J., Cruz-Garza, J.G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S.H., Zhu, F., Pons, J.L.: Powered exoskeletons for bipedal locomotion after spinal cord injury. J. Neural Eng. 13(3), 031001 (2016)CrossRef
2.
Zurück zum Zitat Esquenazi, A., Talaty, M., Jayaraman, A.: Powered exoskeletons for walking assistance in persons with central nervous system injuries: a narrative review. PM&R (2016) Esquenazi, A., Talaty, M., Jayaraman, A.: Powered exoskeletons for walking assistance in persons with central nervous system injuries: a narrative review. PM&R (2016)
3.
Zurück zum Zitat Farris, J.: Design of a powered lower-limb exoskeleton and control for gait assistance in paraplegics. Ph.D. thesis, Vanderbilt University (2012) Farris, J.: Design of a powered lower-limb exoskeleton and control for gait assistance in paraplegics. Ph.D. thesis, Vanderbilt University (2012)
4.
Zurück zum Zitat Gedliczka, A.: Atlas antropometryczny populacji polskiej - dane do projektowania i oceny ergonomicznej. Centralny Instytut Ochrony Pracy (2001) Gedliczka, A.: Atlas antropometryczny populacji polskiej - dane do projektowania i oceny ergonomicznej. Centralny Instytut Ochrony Pracy (2001)
5.
Zurück zum Zitat Kabaciński, R., Kowalski, M.: Preliminary study on accuracy of step length measurement for CIE exoskeleton. In: 2016 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (2016) Kabaciński, R., Kowalski, M.: Preliminary study on accuracy of step length measurement for CIE exoskeleton. In: 2016 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (2016)
6.
Zurück zum Zitat Kaczmarek, P., Kabaciński, R., Kowalski, M.: Konstrukcja egzoszkieletu kończyn dolnych do rehabilitacji i wspomagania lokomocji. In: Prace naukowe Politechniki Warszawskiej, vol. 182, pp. 71–81. Oficyna wydawnicza Politechniki Warszawskiej (2012) Kaczmarek, P., Kabaciński, R., Kowalski, M.: Konstrukcja egzoszkieletu kończyn dolnych do rehabilitacji i wspomagania lokomocji. In: Prace naukowe Politechniki Warszawskiej, vol. 182, pp. 71–81. Oficyna wydawnicza Politechniki Warszawskiej (2012)
7.
Zurück zum Zitat Mikołajewska, E., Mikołajewski, D.: Exoskeletons in neurological diseases-current and potential future applications. Adv. Clin. Exp. Med. 20(2), 227–233 (2011) Mikołajewska, E., Mikołajewski, D.: Exoskeletons in neurological diseases-current and potential future applications. Adv. Clin. Exp. Med. 20(2), 227–233 (2011)
8.
Zurück zum Zitat Quintero, H.: A powered lower limb exoskeleton supplemented with FES for gait assistance in paraplegic patients. Ph.D. thesis, Vanderbilt University (2012) Quintero, H.: A powered lower limb exoskeleton supplemented with FES for gait assistance in paraplegic patients. Ph.D. thesis, Vanderbilt University (2012)
9.
Zurück zum Zitat Rojek, A., Zwolińska-Mirek, K., Oleksy, Ł., Cygoń, K., Michałek, A., Janiszewska, N., Mika, A.: From the treadmill to the exoskeleton. Evolution of mechanical gait assistance methods. Med. Rehabil. 19(4), 25–33 (2015) Rojek, A., Zwolińska-Mirek, K., Oleksy, Ł., Cygoń, K., Michałek, A., Janiszewska, N., Mika, A.: From the treadmill to the exoskeleton. Evolution of mechanical gait assistance methods. Med. Rehabil. 19(4), 25–33 (2015)
10.
Zurück zum Zitat Swift, T.A.: Control and trajectory generation of a wearable mobility exoskeleton for spinal cord injury patients. Ph.D. thesis, University of California, Berkeley (2011) Swift, T.A.: Control and trajectory generation of a wearable mobility exoskeleton for spinal cord injury patients. Ph.D. thesis, University of California, Berkeley (2011)
Metadaten
Titel
Influence of Exoskeleton Parameters Calibration Inaccuracies on the Step Length Error
verfasst von
Rafał Kabaciński
Mateusz Kowalski
Piotr Kaczmarek
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-54042-9_32