Skip to main content

11.01.2021

Integrating Metamaterial Antenna Node and LiFi for Privacy Preserving Intelligent COVID-19 Hospital Patient Management

verfasst von: A. Garhwal, M. Bunruangses, A. E. Arumona, P. Youplao, K. Ray, S. Suwandee, P. Yupapin

Erschienen in: Cognitive Computation

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Light fidelity (LiFi) and wireless fidelity (WiFi) can be applied with the same network under the different constraints, which is suitable for COVID-19 surveillance in hospitals. The LiFi network is a high-capacity and security platform. A COVID-19 surveillance system using LiFi is proposed, which consists of two switching modes: communication and surveillance. Firstly, the communication targets are to accommodate the electromagnetic interference (EMI) immunity and high-capacity and security data transmission, where secondly the COVID-19 surveillance can be applied. In operation, the up and downlink system uses a metamaterial antenna embedded by Mach Zehnder interferometer (MZI). An antenna consists of silver bars embedded at the microring center with two-phase modulators at its sides. The entangled source namely a dark soliton is applied to form the transmission, where the information security based on quantum cryptography can be managed. By using the suitable parameters, the whispering gallery modes (WGMs) are generated and the up and downlink nodes are formed. The input information is multiplexed with time to form the multiplexed signals, where the big data transmission (40 Pbit \({\mathrm{s}}^{-1})\) can be employed. By using the surveillance mode, the plasmonic antenna can be applied for temperature and electric force sensors, which can offer the disinfectant spray and temperature sensor for COVID-19 applications. The optimum plasma force sensitivity is 0.16 N kg−1 mW−1. The center frequencies of 191.48 THz and 199.41 THz are obtained for uplink and downlink antennas, respectively. The optimum temperature sensitivity is 0.05 rads−1 °C−1. In conclusion, the novelty of proposed work is that the integrated sensor circuits are employed for COVID-19 surveillance in the hospital. The fuzzy-based system is designed for critical patient monitoring alert using this surveillance and management inside the hospital for COVID-19 patients.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Yu J, Qiao S, Guo R, Wang X. Cryo-EM structures of HKU2 and SADS-CoV spike glycoproteins provide insights into coronavirus evolution. Nat Commun. 2020;11(3070):1–12. Yu J, Qiao S, Guo R, Wang X. Cryo-EM structures of HKU2 and SADS-CoV spike glycoproteins provide insights into coronavirus evolution. Nat Commun. 2020;11(3070):1–12.
3.
Zurück zum Zitat Chen B, Tian EK, He B, Tian L, Han R, Wang S, et al. Overview of lethal human coronaviruses. Signal Transduct Target Ther. 2020;5(89):1–16. Chen B, Tian EK, He B, Tian L, Han R, Wang S, et al. Overview of lethal human coronaviruses. Signal Transduct Target Ther. 2020;5(89):1–16.
4.
Zurück zum Zitat Duarte PM, Santana VTPde. Disinfection measures and control of SARS-COV-2 transmission. Global Biosecurity. 2020;1(3). Duarte PM, Santana VTPde. Disinfection measures and control of SARS-COV-2 transmission. Global Biosecurity. 2020;1(3).
5.
Zurück zum Zitat Buonnano M, Welch D, Shuryak I, Brenner DJ. Far-UVC light (222nm) efficiently and safely inactivates airborne human coronaviruses. Sci Rep. 2020;10(10285):1–8. Buonnano M, Welch D, Shuryak I, Brenner DJ. Far-UVC light (222nm) efficiently and safely inactivates airborne human coronaviruses. Sci Rep. 2020;10(10285):1–8.
6.
Zurück zum Zitat Xiao K, Zhai J, Feng Y, Zhou N, Zhang X, Zou JJ et al. Isolation of SARS-CoV-2-related coronavirus from Malayan pangolins. Nature. 2020; 1–18. Xiao K, Zhai J, Feng Y, Zhou N, Zhang X, Zou JJ et al. Isolation of SARS-CoV-2-related coronavirus from Malayan pangolins. Nature. 2020; 1–18.
7.
Zurück zum Zitat Tay MZ, Poh CM, Renia L, MacAry PA, Ng LFP. The trinity of COVID-19: immunity, inflammation and intervention. Nat Rev Immunol. 2020;2020(20):363–74.CrossRef Tay MZ, Poh CM, Renia L, MacAry PA, Ng LFP. The trinity of COVID-19: immunity, inflammation and intervention. Nat Rev Immunol. 2020;2020(20):363–74.CrossRef
8.
Zurück zum Zitat Seah I, Su X, Lingam G. Revisiting the dangers of the coronavirus in the ophthalmology practice. Eye. 2020;34:1155–7.CrossRef Seah I, Su X, Lingam G. Revisiting the dangers of the coronavirus in the ophthalmology practice. Eye. 2020;34:1155–7.CrossRef
9.
Zurück zum Zitat Rabenau HF, Kampf G, Cinatl J, Doerr HW. Efficacy of various disinfectants against SARS coronavirus. J Hosp Infect. 2005;61(2):107–11.CrossRef Rabenau HF, Kampf G, Cinatl J, Doerr HW. Efficacy of various disinfectants against SARS coronavirus. J Hosp Infect. 2005;61(2):107–11.CrossRef
10.
Zurück zum Zitat Meng L, Hua F, Bian Z. Coronavirus disease 2019 (COVID-19): emerging and future challenges for dental and oral medicine. J Dent Res. 2020;99(5):481–7.CrossRef Meng L, Hua F, Bian Z. Coronavirus disease 2019 (COVID-19): emerging and future challenges for dental and oral medicine. J Dent Res. 2020;99(5):481–7.CrossRef
11.
Zurück zum Zitat Ather A, Patel B, Ruparel NB, Diogenes A, Hargreaves KM. Coronavirus diseases 19 (COVID-19): implications for clinical dental care. J Endod. 2020;46(5):584–95.CrossRef Ather A, Patel B, Ruparel NB, Diogenes A, Hargreaves KM. Coronavirus diseases 19 (COVID-19): implications for clinical dental care. J Endod. 2020;46(5):584–95.CrossRef
12.
Zurück zum Zitat Youplao P, Sarapat N, Pornsuwancharoen N, Chaiwong K, Jalil MA, Amiri IS, et al. Plasmonic op-amp circuit model using the inline successive microring pumping scheme. Microsyst Technol. 2018;24:3689–95.CrossRef Youplao P, Sarapat N, Pornsuwancharoen N, Chaiwong K, Jalil MA, Amiri IS, et al. Plasmonic op-amp circuit model using the inline successive microring pumping scheme. Microsyst Technol. 2018;24:3689–95.CrossRef
13.
Zurück zum Zitat Bunruangses M, Youplao P, Amiri IS, Pornsuwancharoen N, Punthawanunt S, Singh G, et al. Microring distributed sensors using space-time function control. IEEE Sens J. 2020;20(2):799–805.CrossRef Bunruangses M, Youplao P, Amiri IS, Pornsuwancharoen N, Punthawanunt S, Singh G, et al. Microring distributed sensors using space-time function control. IEEE Sens J. 2020;20(2):799–805.CrossRef
14.
Zurück zum Zitat Garhwal A, Ray K, Arumona AE, Bharti GK, Amiri IS, Yupapin P. Spin-wave generation using MZI embedded plasmonic antenna for quantum communications. Opt Quant Electron. 2020;52(241):1–12. Garhwal A, Ray K, Arumona AE, Bharti GK, Amiri IS, Yupapin P. Spin-wave generation using MZI embedded plasmonic antenna for quantum communications. Opt Quant Electron. 2020;52(241):1–12.
15.
Zurück zum Zitat Arumona AE, Amiri IS, Yupapin P. Plasmonic micro-antenna characteristics using gold grating embedded in a panda-ring circuit. Plasmonics. 2020;2020(15):279–85.CrossRef Arumona AE, Amiri IS, Yupapin P. Plasmonic micro-antenna characteristics using gold grating embedded in a panda-ring circuit. Plasmonics. 2020;2020(15):279–85.CrossRef
16.
Zurück zum Zitat Arumona AE, Amiri IS, Punthawanunt S, Yupapin P. High density quantum bit generation using microring plasmonic antenna. Opt Quant Electron. 2020;52(208):1–12. Arumona AE, Amiri IS, Punthawanunt S, Yupapin P. High density quantum bit generation using microring plasmonic antenna. Opt Quant Electron. 2020;52(208):1–12.
17.
Zurück zum Zitat Otter JA, Donskey C, Yezli S, Douthwaite S, Goldenberg SD, Weber DJ. Transmission of SARS and MARS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination. J Hosp Infect. 2016;92:235–50.CrossRef Otter JA, Donskey C, Yezli S, Douthwaite S, Goldenberg SD, Weber DJ. Transmission of SARS and MARS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination. J Hosp Infect. 2016;92:235–50.CrossRef
18.
Zurück zum Zitat Deshmukh SP, Patil SM, Mullani SB, Delekar SD. Silver nanoparticles as an effective disinfectant: a review. Mater Sci Eng: C. 2019;97:954–65.CrossRef Deshmukh SP, Patil SM, Mullani SB, Delekar SD. Silver nanoparticles as an effective disinfectant: a review. Mater Sci Eng: C. 2019;97:954–65.CrossRef
19.
Zurück zum Zitat Bashir S, Chamakura K, Perez-Ballestero R, Luo Z, Liu J. Mechanism of silver nanoparticles as a disinfectant. Int J Green Energy. 2011;3(2):118–33. Bashir S, Chamakura K, Perez-Ballestero R, Luo Z, Liu J. Mechanism of silver nanoparticles as a disinfectant. Int J Green Energy. 2011;3(2):118–33.
20.
Zurück zum Zitat Ding H. Application and design of patient temperature acquisition system based on wireless sensor network. Int J Online Biomed Eng. 2017;13(5):18–28. Ding H. Application and design of patient temperature acquisition system based on wireless sensor network. Int J Online Biomed Eng. 2017;13(5):18–28.
21.
Zurück zum Zitat Geng Y, Li X, Tan X, Deng Y, Yu Y. High-sensitivity Mach Zehnder interferometric temperature fiber sensor based on a waist-enlarged fusion bitaper. IEEE Sens J. 2011;11(11):2891–4.CrossRef Geng Y, Li X, Tan X, Deng Y, Yu Y. High-sensitivity Mach Zehnder interferometric temperature fiber sensor based on a waist-enlarged fusion bitaper. IEEE Sens J. 2011;11(11):2891–4.CrossRef
22.
Zurück zum Zitat Geng Y, Li X, Tan X, Deng Y, Yu Y. Compact and ultrasensitive temperature sensor with a fully liquid-filled photonic crystal fiber Mach-Zehnder interferometer. IEEE Sens J. 2014;14(1):167–70.CrossRef Geng Y, Li X, Tan X, Deng Y, Yu Y. Compact and ultrasensitive temperature sensor with a fully liquid-filled photonic crystal fiber Mach-Zehnder interferometer. IEEE Sens J. 2014;14(1):167–70.CrossRef
23.
Zurück zum Zitat Alexandru AG, Radu IM, Bizon ML. Big data in healthcare-opportunities and challenges. Informatica Economica. 2018;22(2):43–54.CrossRef Alexandru AG, Radu IM, Bizon ML. Big data in healthcare-opportunities and challenges. Informatica Economica. 2018;22(2):43–54.CrossRef
24.
Zurück zum Zitat Dash S, Shakyawar SK, Sharma M, Kaushik S. Big data in healthcare: management, analysis and future prospects. J Big Data. 2019;6(54):1–25. Dash S, Shakyawar SK, Sharma M, Kaushik S. Big data in healthcare: management, analysis and future prospects. J Big Data. 2019;6(54):1–25.
25.
Zurück zum Zitat Pires P, Mendes L, Mendes J, Rodrigues R, Pereira A. Integrated e healthcare system for elderly people. Cognitive Computing. 2015;8:368–84.CrossRef Pires P, Mendes L, Mendes J, Rodrigues R, Pereira A. Integrated e healthcare system for elderly people. Cognitive Computing. 2015;8:368–84.CrossRef
26.
Zurück zum Zitat Price WN, Cohen IG. Privacy in age of medical big data. Nat Med. 2019;25(1):37–43.CrossRef Price WN, Cohen IG. Privacy in age of medical big data. Nat Med. 2019;25(1):37–43.CrossRef
27.
Zurück zum Zitat Liu S, Liu W, Guo G, Cai B, Liu X. Cryptanalysis of controlled bidirectional quantum secure direct communication network using classical XOR operation and quantum entanglement. IEEE Commun Lett. 2017;21(10):2202–5.CrossRef Liu S, Liu W, Guo G, Cai B, Liu X. Cryptanalysis of controlled bidirectional quantum secure direct communication network using classical XOR operation and quantum entanglement. IEEE Commun Lett. 2017;21(10):2202–5.CrossRef
28.
29.
Zurück zum Zitat Abd El-Latif AA, Abd-El-Atty B, Talha M. Robust encryption of quantum medical images. Special Section on Mobile Multimedia for Health Care, IEEE Access. 2018; 6: 1073–81. Abd El-Latif AA, Abd-El-Atty B, Talha M. Robust encryption of quantum medical images. Special Section on Mobile Multimedia for Health Care, IEEE Access. 2018; 6: 1073–81.
30.
Zurück zum Zitat Arumona AE, Garhal A, Punthawanunt S, Ray K, Youplao P, Yupapin P. Micro-metamaterial antenna characteristics using microring embedded silver bars. Microsyst Technol. 2020; 1–4. Arumona AE, Garhal A, Punthawanunt S, Ray K, Youplao P, Yupapin P. Micro-metamaterial antenna characteristics using microring embedded silver bars. Microsyst Technol. 2020; 1–4.
31.
Zurück zum Zitat Arumona AE, Garhwal A, Youplao P, Amiri IS, Ray K, Punthawanunt S et al. Electron cloud spectroscopy using microring Fabry-Perot sensor embedded gold grating. IEEE Sensors Journal. 2020;20(18):10564-71.CrossRef Arumona AE, Garhwal A, Youplao P, Amiri IS, Ray K, Punthawanunt S et al. Electron cloud spectroscopy using microring Fabry-Perot sensor embedded gold grating. IEEE Sensors Journal. 2020;20(18):10564-71.CrossRef
32.
Zurück zum Zitat Phatharacorn P, Chiangga S, Yupapin P. Analytical and simulation of a triple micro whispering gallery mode probe system for a 3D blood flow rate sensor. Appl Opt. 2016;55:9504–13.CrossRef Phatharacorn P, Chiangga S, Yupapin P. Analytical and simulation of a triple micro whispering gallery mode probe system for a 3D blood flow rate sensor. Appl Opt. 2016;55:9504–13.CrossRef
33.
Zurück zum Zitat Mirmira SR, Fletcher LS. Review of the thermal conductivity of thin films. J Thermophys Heat Trans. 1998;12(2):121–31.CrossRef Mirmira SR, Fletcher LS. Review of the thermal conductivity of thin films. J Thermophys Heat Trans. 1998;12(2):121–31.CrossRef
34.
Zurück zum Zitat OptiFDTD Technical Background and Tutorials (Finite Difference Time Domain) Photonics Simulation Software, Version 12.0. http://www.optiwave.com, Searched on 20th May, 2020. OptiFDTD Technical Background and Tutorials (Finite Difference Time Domain) Photonics Simulation Software, Version 12.0. http://​www.​optiwave.​com, Searched on 20th May, 2020.
35.
Zurück zum Zitat Garhwal A, Arumona AE, Ray K, Youplao P, Suwandee S, Yupapin P. Microplasma source circuit using microring space-time distortion control. IEEE Transactions on Plasma Science. 2020;48(10):3600-5.CrossRef Garhwal A, Arumona AE, Ray K, Youplao P, Suwandee S, Yupapin P. Microplasma source circuit using microring space-time distortion control. IEEE Transactions on Plasma Science. 2020;48(10):3600-5.CrossRef
36.
Zurück zum Zitat Young HD. Universityphysics,11thEd. USA: AddisonWesley Publishing Company; 2006. Young HD. Universityphysics,11thEd. USA: AddisonWesley Publishing Company; 2006.
37.
Zurück zum Zitat Babar S, Weaver JH. Optical constants of Cu, Ag, and Au revisited. Appl Opt. 2015;54(3):477–81.CrossRef Babar S, Weaver JH. Optical constants of Cu, Ag, and Au revisited. Appl Opt. 2015;54(3):477–81.CrossRef
38.
Zurück zum Zitat Pornsuwancharoen N, Amiri IS, Suhailin FH, Aziz MS, Ali J, Singh G, et al. Micro-current source generated by a WGM of light within a stacked silicon-graphene-Au waveguide. IEEE Photonics Technol Lett. 2017;29(21):1768–71.CrossRef Pornsuwancharoen N, Amiri IS, Suhailin FH, Aziz MS, Ali J, Singh G, et al. Micro-current source generated by a WGM of light within a stacked silicon-graphene-Au waveguide. IEEE Photonics Technol Lett. 2017;29(21):1768–71.CrossRef
39.
Zurück zum Zitat Bunruangses M, Youplao P, Amiri IS, Pornsuwancharoen, Yupapin P. Double vision model using space-time function control within silicon microring system. Silicon. 2019; 1–6. Bunruangses M, Youplao P, Amiri IS, Pornsuwancharoen, Yupapin P. Double vision model using space-time function control within silicon microring system. Silicon. 2019; 1–6.
40.
Zurück zum Zitat Kibira MG, Nguyen K, Villardi GP, Zhao O, Ishizu K, Kojima F. Big data analytics, machine learning and artificial intelligence in next generation wireless networks. IEEE Access. 2018;6:32328–38.CrossRef Kibira MG, Nguyen K, Villardi GP, Zhao O, Ishizu K, Kojima F. Big data analytics, machine learning and artificial intelligence in next generation wireless networks. IEEE Access. 2018;6:32328–38.CrossRef
41.
Zurück zum Zitat Tamee K, Yupapin P. Psychiatric investigation using WGMs in microring circuits. J Innov Opt Health Sci 2013;6(4), 1350004–1–7. Tamee K, Yupapin P. Psychiatric investigation using WGMs in microring circuits. J Innov Opt Health Sci 2013;6(4), 1350004–1–7.
42.
Zurück zum Zitat Bunruangses M, Youplao P, Amiri S, Pornsuwancharoen, Yupapin P. Double vision model using space-time function control within silicon microring system. Silicon, 2019; 1–6. Bunruangses M, Youplao P, Amiri S, Pornsuwancharoen, Yupapin P. Double vision model using space-time function control within silicon microring system. Silicon, 2019; 1–6.
43.
Zurück zum Zitat Bunruangses M, Chaiwong K, Amiri IS, Youplao P, Pornsuwancharoen N, Yupapin P. High-density wavelength multiplexing model for THz-EMI transmission. Wirel Pers Commun; 2020;1–6. Bunruangses M, Chaiwong K, Amiri IS, Youplao P, Pornsuwancharoen N, Yupapin P. High-density wavelength multiplexing model for THz-EMI transmission. Wirel Pers Commun; 2020;1–6.
44.
Zurück zum Zitat Arumona AE, Amiri IS, Yupapin P. Plasmonic microring-antenna characteristics using gold grating embedded in a Panda-ring circuit. Plasmonics. 2019;15:279–85.CrossRef Arumona AE, Amiri IS, Yupapin P. Plasmonic microring-antenna characteristics using gold grating embedded in a Panda-ring circuit. Plasmonics. 2019;15:279–85.CrossRef
45.
Zurück zum Zitat Youplao P, Pornsuwancharoen, Amiri IS, Ali J, Grattan KTV. Microring stereo sensor model using Kerr-Vernier effects for bio-cell sensor and communication. Nano Communication 2018; 17: 30–35. Youplao P, Pornsuwancharoen, Amiri IS, Ali J, Grattan KTV. Microring stereo sensor model using Kerr-Vernier effects for bio-cell sensor and communication. Nano Communication 2018; 17: 30–35.
46.
Zurück zum Zitat Bunruangses M, Sunat K, Mitatha S, Yupapin. Vehicular ad hoc network for a surveillance system using multifrequency band enhancement. Opt Eng 2010; 49: 095001. Bunruangses M, Sunat K, Mitatha S, Yupapin. Vehicular ad hoc network for a surveillance system using multifrequency band enhancement. Opt Eng 2010; 49: 095001.
47.
Zurück zum Zitat Bunruangses M, Arumona AE, Youplao P, Pornsuwancharoen N, Ray K, Yupapin P. Modeling of a superconducting sensor with microring-embedded gold-island space-time control. Journal of Computational Electronics. 2020;19:1678–84.CrossRef Bunruangses M, Arumona AE, Youplao P, Pornsuwancharoen N, Ray K, Yupapin P. Modeling of a superconducting sensor with microring-embedded gold-island space-time control. Journal of Computational Electronics. 2020;19:1678–84.CrossRef
49.
Zurück zum Zitat Al-Dmour JA, SagahyroonAssim, Al-Ali Ar, Abusnana Salah, A fuzzy logic-based warning system for patient classification. Health Inform J. 2019;25(3):1004–24. Al-Dmour JA, SagahyroonAssim, Al-Ali Ar, Abusnana Salah, A fuzzy logic-based warning system for patient classification. Health Inform J. 2019;25(3):1004–24.
50.
Zurück zum Zitat Belmonte-Fernandez O, Caballer-Miedes A, Chinellato A, Montoliu E, Sansano-Sansano E, Garcia-Vidal R. Anomaly detection in activities of daily living with linear drift. Cognitive Computation. 2020;12:1233–51.CrossRef Belmonte-Fernandez O, Caballer-Miedes A, Chinellato A, Montoliu E, Sansano-Sansano E, Garcia-Vidal R. Anomaly detection in activities of daily living with linear drift. Cognitive Computation. 2020;12:1233–51.CrossRef
Metadaten
Titel
Integrating Metamaterial Antenna Node and LiFi for Privacy Preserving Intelligent COVID-19 Hospital Patient Management
verfasst von
A. Garhwal
M. Bunruangses
A. E. Arumona
P. Youplao
K. Ray
S. Suwandee
P. Yupapin
Publikationsdatum
11.01.2021
Verlag
Springer US
Erschienen in
Cognitive Computation
Print ISSN: 1866-9956
Elektronische ISSN: 1866-9964
DOI
https://doi.org/10.1007/s12559-020-09778-6