Abstract

Design and fabrication of patient-specific radiotherapy phantom is now more accessible and cost-effective using 3D printing technology. This study fabricates a 3D printed radiotherapy phantom for quality assurance of Intensity Modulated Radiotherapy (IMRT). Using an IMRT Thorax anthropomorphic phantom (CIRS) as a substitute for an actual patient, a 3D printed radiotherapy phantom was designed based on a patient computed tomography (CT) scan during treatment planning. Before printing the phantom, the tissue equivalence of Acrylonitrile Butadiene Styrene (ABS) and Polylactic Acid (PLA) polymers used in 3D printing was characterized by quantifying its CT number and relative electron density to water. In the 3D printed phantom fabricated, it was shown that soft tissue and lungs can be simulated using PLA 100% infill \( \left( {\rho_{e,w}^{130kV} = 0.99} \right) \) and 20% infill plastic \( \left( {\rho_{e,w}^{130kV} = 0.20} \right) \).

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Nakamura, M., Minemura, T., Ishikura, S., Nishio, T., Narita, Y., & Nishimura, Y. An on-site audit system for dosimetry credentialing of intensity modulated radiotherapy in Japanese Clinical Oncology Group (JCOG) clinical trials. Physical Medical, 32, 987–991. (2016). Nakamura, M., Minemura, T., Ishikura, S., Nishio, T., Narita, Y., & Nishimura, Y. An on-site audit system for dosimetry credentialing of intensity modulated radiotherapy in Japanese Clinical Oncology Group (JCOG) clinical trials. Physical Medical, 32, 987–991. (2016).
2.
Zurück zum Zitat Leary, M., Kron, T. Keller, C., Franich, R. Lonski, P. Subic, A. & Brandt, M. Additive manufacture of custom radiation dosimetry phantoms: An automated method compatible with commercial polymer 3D printers. Materials and Design. 86. 487–499. (2015). Leary, M., Kron, T. Keller, C., Franich, R. Lonski, P. Subic, A. & Brandt, M. Additive manufacture of custom radiation dosimetry phantoms: An automated method compatible with commercial polymer 3D printers. Materials and Design. 86. 487–499. (2015).
3.
Zurück zum Zitat Rehman, J. Tailor, R. Isa, M. Afzal, M. Chow, J., & Ibbot, G. Evaluation of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study. Medical Dosimetry. 40. 70–75. (2014). Rehman, J. Tailor, R. Isa, M. Afzal, M. Chow, J., & Ibbot, G. Evaluation of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study. Medical Dosimetry. 40. 70–75. (2014).
4.
Zurück zum Zitat Sini, C., Broggi, S., Fiorino, C. Cattaneo, G. & Calandrino, R. (2015). Accuracy of dose calculation algorithm for static and rotational IMRT of lung cancer: A phantom study. Physica Medica, 31, 382–390. Sini, C., Broggi, S., Fiorino, C. Cattaneo, G. & Calandrino, R. (2015). Accuracy of dose calculation algorithm for static and rotational IMRT of lung cancer: A phantom study. Physica Medica, 31, 382–390.
5.
Zurück zum Zitat Sumida, I., Yamaguchi, H., Das, I., Kizaki, H., Aboshi, K., Tsujii, M. Yamada, Y., Suzuki, O., Seo, Y., Isohashi, F. & Ogawa, K. (2016). Intensity-modulated radiation therapy dose verification using fluence and portal imaging device. Journal of Applied Clinical Medical Physics. Volume 17. 259–271. Sumida, I., Yamaguchi, H., Das, I., Kizaki, H., Aboshi, K., Tsujii, M. Yamada, Y., Suzuki, O., Seo, Y., Isohashi, F. & Ogawa, K. (2016). Intensity-modulated radiation therapy dose verification using fluence and portal imaging device. Journal of Applied Clinical Medical Physics. Volume 17. 259–271.
6.
Zurück zum Zitat International Atomic Energy Agency (IAEA). (2008). Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques. IAEA-TECDOC-1583, IAEA, Vienna. International Atomic Energy Agency (IAEA). (2008). Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques. IAEA-TECDOC-1583, IAEA, Vienna.
7.
Zurück zum Zitat Kumar, R., Sharma, S. D., Despande, S., Ghadi, Y., Shaiju, V.S., Amols, H.I. & Mayya, Y.S. (2009). Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT. Journal of Applied Clinical Medical Physics, Volume 11, Number 1. Kumar, R., Sharma, S. D., Despande, S., Ghadi, Y., Shaiju, V.S., Amols, H.I. & Mayya, Y.S. (2009). Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT. Journal of Applied Clinical Medical Physics, Volume 11, Number 1.
8.
Zurück zum Zitat Ehler, E.D., Barney, B.M., et al. (2014). Patient specific 3D printed phantom for IMRT quality assurance. Phys. Med. Biol. 59, 5763–5773. Ehler, E.D., Barney, B.M., et al. (2014). Patient specific 3D printed phantom for IMRT quality assurance. Phys. Med. Biol. 59, 5763–5773.
9.
Zurück zum Zitat Kairn, T., Crowe, S.B. & Markwell, T. (2015). Use of 3D Printed Materials as Tissue-Equivalent Phantoms. World Congress on Medical Physics and Biomedical Engineering, June 7–12, 2015. Kairn, T., Crowe, S.B. & Markwell, T. (2015). Use of 3D Printed Materials as Tissue-Equivalent Phantoms. World Congress on Medical Physics and Biomedical Engineering, June 7–12, 2015.
10.
Zurück zum Zitat Zou, W., Fisher, T., Zhang, M., Kim, L., Chen, T., Narra, V., Swann, B., Singh, R., Siderit, R., Yin, L., Teo, B.K., Mckenna, M., McDonough, J. & Ning, Y.J. (2015). Potential of 3D printing technologies for fabrication of electron bolus and proton compensators. Journal of Applied Clinical Medical Physics. Volume 16. 90–98. Zou, W., Fisher, T., Zhang, M., Kim, L., Chen, T., Narra, V., Swann, B., Singh, R., Siderit, R., Yin, L., Teo, B.K., Mckenna, M., McDonough, J. & Ning, Y.J. (2015). Potential of 3D printing technologies for fabrication of electron bolus and proton compensators. Journal of Applied Clinical Medical Physics. Volume 16. 90–98.
12.
Zurück zum Zitat Bibb, R., Thompson, D. & Winder, J. (2011). Computed tomography characterization of additive manufacturing materials. Medical Engineering & Physics 33, 590–596. Bibb, R., Thompson, D. & Winder, J. (2011). Computed tomography characterization of additive manufacturing materials. Medical Engineering & Physics 33, 590–596.
13.
Zurück zum Zitat Canters, R.A., Lips, I.M., Wendling, M., Kusters, M., Zeeland, M., Gerritsen, R.M., Poortmans, P. & Verhoef, C.G. (2016). Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer. Radiotherapy and Oncology, 121, 148–153. https://doi.org/10.1016/j.radonc.2016.07.011. Canters, R.A., Lips, I.M., Wendling, M., Kusters, M., Zeeland, M., Gerritsen, R.M., Poortmans, P. & Verhoef, C.G. (2016). Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer. Radiotherapy and Oncology, 121, 148–153. https://​doi.​org/​10.​1016/​j.​radonc.​2016.​07.​011.
Metadaten
Titel
Intensity Modulated Radiotherapy (IMRT) Phantom Fabrication Using Fused Deposition Modeling (FDM) 3D Printing Technique
verfasst von
John Paul Bustillo
Roy Tumlos
Randal Zandro Remoto
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9023-3_92

Neuer Inhalt