Skip to main content
Erschienen in:
Buchtitelbild

2014 | OriginalPaper | Buchkapitel

1. Introduction

verfasst von : Mohammed Rafiq Abdul Kadir

Erschienen in: Computational Biomechanics of the Hip Joint

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This chapter introduces the hip joint and hip disorders that may lead to total replacement of the joint. The internal morphology of the proximal femur, which can be categorised into one of three types, is of primary importance as it will affect the type of implant most suitable for the treatment. Osteoarthritis is one of the most common reasons for hip replacement where in certain cases can severely limit patient mobility and reduce quality of life. Implants for total hip arthroplasty (THA) can be categorised into one of two types, cemented and cementless. Whilst cemented has been regarded as the gold standard, the cementless coutnerpart is gaining popularity. However, the issue of primary stability has to be addressed and tackled if the cementless approach was to be widely accepted. Finite element method will be used to analyse the stability of the cementless implants for hip arthroplasty.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dorr LD, Faugere M-C, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRef Dorr LD, Faugere M-C, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242CrossRef
2.
Zurück zum Zitat Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop Relat Res 235:148–165 Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop Relat Res 235:148–165
3.
Zurück zum Zitat Macdonald DA (1998) Mini symposium: total hip replacement—(i) Risks versus rewards of total hip replacement. Curr Orthopaed 12(4):229–231MathSciNetCrossRef Macdonald DA (1998) Mini symposium: total hip replacement—(i) Risks versus rewards of total hip replacement. Curr Orthopaed 12(4):229–231MathSciNetCrossRef
4.
Zurück zum Zitat Bauer TW, Schils J (1999) The pathology of total joint arthroplasty—II. Mech Implant Fail Skeletal Radiol 28(9):483–497CrossRef Bauer TW, Schils J (1999) The pathology of total joint arthroplasty—II. Mech Implant Fail Skeletal Radiol 28(9):483–497CrossRef
5.
Zurück zum Zitat Emery D, Britton A, Clarke H, Grover M (1997) The stanmore total hip arthroplasty: A 15- to 20-year follow-up study. J Arthroplasty 12(7):728–735CrossRef Emery D, Britton A, Clarke H, Grover M (1997) The stanmore total hip arthroplasty: A 15- to 20-year follow-up study. J Arthroplasty 12(7):728–735CrossRef
6.
Zurück zum Zitat El Warrak AO, Olmstead ML, von Rechenberg B, Auer JA (2001) A review of aseptic loosening in total hip arthroplasty. Vet Comp Orthopaed 14(3):115–124 El Warrak AO, Olmstead ML, von Rechenberg B, Auer JA (2001) A review of aseptic loosening in total hip arthroplasty. Vet Comp Orthopaed 14(3):115–124
7.
Zurück zum Zitat Dorr LD, Wan Z, Gruen T (1997) Functional results in total hip replacement in patients 65 years and older. Clin Orthop Relat Res 336:143–151CrossRef Dorr LD, Wan Z, Gruen T (1997) Functional results in total hip replacement in patients 65 years and older. Clin Orthop Relat Res 336:143–151CrossRef
8.
Zurück zum Zitat Haber D, Goodman SB (1998) Total hip arthroplasty in juvenile chronic arthritis: a consecutive series. J Arthroplasty 13(3):259–265CrossRef Haber D, Goodman SB (1998) Total hip arthroplasty in juvenile chronic arthritis: a consecutive series. J Arthroplasty 13(3):259–265CrossRef
9.
Zurück zum Zitat Harris WH (1997) Options for primary femoral fixation in total hip arthroplasty. Cemented stems for all. Clin Orthop Relat Res 344:118–123CrossRef Harris WH (1997) Options for primary femoral fixation in total hip arthroplasty. Cemented stems for all. Clin Orthop Relat Res 344:118–123CrossRef
10.
Zurück zum Zitat Stauffer RN (1982) 10-year follow-up-study of total hip-replacement—with particular reference to roentgenographic loosening of the components. J Bone Joint Surg Am 64(7):983–990 Stauffer RN (1982) 10-year follow-up-study of total hip-replacement—with particular reference to roentgenographic loosening of the components. J Bone Joint Surg Am 64(7):983–990
11.
Zurück zum Zitat Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A 10-year follow-up of 100 consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982 Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A 10-year follow-up of 100 consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982
12.
Zurück zum Zitat Rasquinha VJ, Dua V, Rodriguez JA, Ranawat CS (2003) Fifteen-year survivorship of a collarless, cemented, normalized femoral stem in primary hybrid total hip arthroplasty with a modified third-generation cement technique. J Arthroplasty 18(7 Suppl 1):86–94CrossRef Rasquinha VJ, Dua V, Rodriguez JA, Ranawat CS (2003) Fifteen-year survivorship of a collarless, cemented, normalized femoral stem in primary hybrid total hip arthroplasty with a modified third-generation cement technique. J Arthroplasty 18(7 Suppl 1):86–94CrossRef
13.
Zurück zum Zitat Oonishi H (1991) The bone-biomaterial interface. Interfacial reactions to bioactive and non-bioactive bone cements. University of Toronto Press, Ontario Oonishi H (1991) The bone-biomaterial interface. Interfacial reactions to bioactive and non-bioactive bone cements. University of Toronto Press, Ontario
14.
Zurück zum Zitat Monti L, Cristofolini L, Viceconti M (2001) Interface biomechanics of the Anca dual fit hip stem: an in vitro experimental study. Proc Inst Mech Eng H 215(6):555–564CrossRef Monti L, Cristofolini L, Viceconti M (2001) Interface biomechanics of the Anca dual fit hip stem: an in vitro experimental study. Proc Inst Mech Eng H 215(6):555–564CrossRef
15.
Zurück zum Zitat Duffy GP, Muratoglu OK, Biggs SA, Larson SL, Lozynsky AJ, Harris WH (2001) A critical assessment of proximal macrotexturing on cemented femoral components. J Arthroplasty 16(8 Suppl 1):42–48CrossRef Duffy GP, Muratoglu OK, Biggs SA, Larson SL, Lozynsky AJ, Harris WH (2001) A critical assessment of proximal macrotexturing on cemented femoral components. J Arthroplasty 16(8 Suppl 1):42–48CrossRef
16.
Zurück zum Zitat Whiteside LA, White SE, Engh CA, Head W (1993) Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. J Arthroplasty 8(2):147–155CrossRef Whiteside LA, White SE, Engh CA, Head W (1993) Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. J Arthroplasty 8(2):147–155CrossRef
17.
Zurück zum Zitat Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85-A (1):109–114 Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85-A (1):109–114
18.
Zurück zum Zitat Bourne RB, Rorabeck CH (1998) A critical look at cementless stems. Taper designs and when to use alternatives. Clin Orthop Relat Res 355:212–223CrossRef Bourne RB, Rorabeck CH (1998) A critical look at cementless stems. Taper designs and when to use alternatives. Clin Orthop Relat Res 355:212–223CrossRef
19.
Zurück zum Zitat Mulliken BD, Nayak N, Bourne RB, Rorabeck CH, Bullas R (1996) Early radiographic results comparing cemented and cementless total hip arthroplasty. J Arthroplasty 11(1):24–33CrossRef Mulliken BD, Nayak N, Bourne RB, Rorabeck CH, Bullas R (1996) Early radiographic results comparing cemented and cementless total hip arthroplasty. J Arthroplasty 11(1):24–33CrossRef
20.
Zurück zum Zitat Zimmerma S, Hawkes WG, Hudson JI, Magaziner J, Hebel JR, Towheed T, Gardner J, Provenzano G, Kenzora JE (2002) Outcomes of surgical management of total HIP replacement in patients aged 65 years and older: Cemented versus cementless femoral components and lateral or anterolateral versus posterior anatomical approach. J Orthop Res 20(2):182–191CrossRef Zimmerma S, Hawkes WG, Hudson JI, Magaziner J, Hebel JR, Towheed T, Gardner J, Provenzano G, Kenzora JE (2002) Outcomes of surgical management of total HIP replacement in patients aged 65 years and older: Cemented versus cementless femoral components and lateral or anterolateral versus posterior anatomical approach. J Orthop Res 20(2):182–191CrossRef
21.
Zurück zum Zitat Nourbash PS, Paprosky WG (1998) Cementless femoral design concerns. Rationale for extensive porous coating. Clin Orthop Relat Res 355:189–199CrossRef Nourbash PS, Paprosky WG (1998) Cementless femoral design concerns. Rationale for extensive porous coating. Clin Orthop Relat Res 355:189–199CrossRef
22.
Zurück zum Zitat Boss JH, Shajrawi I, Soudry M, Mendes DG (1990) Histological features of the interface membrane of failed isoelastic cementless prostheses. Int Orthop 14(4):399–403CrossRef Boss JH, Shajrawi I, Soudry M, Mendes DG (1990) Histological features of the interface membrane of failed isoelastic cementless prostheses. Int Orthop 14(4):399–403CrossRef
23.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69(1):45–55 Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69(1):45–55
24.
Zurück zum Zitat Cruz-Pardos A, Garcia-Cimbrelo E (2001) The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study. J Arthroplasty 16(5):586–597CrossRef Cruz-Pardos A, Garcia-Cimbrelo E (2001) The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study. J Arthroplasty 16(5):586–597CrossRef
25.
Zurück zum Zitat Barrack RL (1998) The adult hip. Pre-operative planning, 1st edn. Lippincott-Raven, USA Barrack RL (1998) The adult hip. Pre-operative planning, 1st edn. Lippincott-Raven, USA
26.
Zurück zum Zitat Healy WL (2002) Hip implant selection for total hip arthroplasty in elderly patients. Clin Orthop Relat Res 405:54–64CrossRef Healy WL (2002) Hip implant selection for total hip arthroplasty in elderly patients. Clin Orthop Relat Res 405:54–64CrossRef
27.
Zurück zum Zitat Reitman RD, Emerson R, Higgins L, Head W (2003) Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty 18:116–121CrossRef Reitman RD, Emerson R, Higgins L, Head W (2003) Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty 18:116–121CrossRef
28.
Zurück zum Zitat Horikoshi M, Macaulay W, Booth RE, Crossett LS, Rubash HE (1994) Comparison of interface membranes obtained from failed cemented and cementless hip and knee prostheses. Clin Orthop Relat Res 309:69–87 Horikoshi M, Macaulay W, Booth RE, Crossett LS, Rubash HE (1994) Comparison of interface membranes obtained from failed cemented and cementless hip and knee prostheses. Clin Orthop Relat Res 309:69–87
29.
Zurück zum Zitat Adam F, Hammer DS, Pfautsch S, Westermann K (2002) Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface. J Arthroplasty 17(2):217–223CrossRef Adam F, Hammer DS, Pfautsch S, Westermann K (2002) Early failure of a press-fit carbon fiber hip prosthesis with a smooth surface. J Arthroplasty 17(2):217–223CrossRef
30.
Zurück zum Zitat Chan YK, Chiu KY, Yip DK, Ng TP, Tang WM (2003) Full weight bearing after non-cemented total hip replacement is compatible with satisfactory results. Int Orthop 27(2):94–97 Chan YK, Chiu KY, Yip DK, Ng TP, Tang WM (2003) Full weight bearing after non-cemented total hip replacement is compatible with satisfactory results. Int Orthop 27(2):94–97
31.
Zurück zum Zitat Woolson ST, Adler NS (2002) The effect of partial or full weight bearing ambulation after cementless total hip arthroplasty. J Arthroplasty 17(7):820–825CrossRef Woolson ST, Adler NS (2002) The effect of partial or full weight bearing ambulation after cementless total hip arthroplasty. J Arthroplasty 17(7):820–825CrossRef
32.
Zurück zum Zitat Kienapfel H, Sprey C, Wilke A, Griss P (1999) Implant fixation by bone ingrowth. J Arthroplasty 14(3):355–368CrossRef Kienapfel H, Sprey C, Wilke A, Griss P (1999) Implant fixation by bone ingrowth. J Arthroplasty 14(3):355–368CrossRef
33.
Zurück zum Zitat Burke DW, O’Connor DO, Zalenski EB, Jasty M, Harris WH (1991) Micromotion of cemented and uncemented femoral components. J Bone Joint Surg Br 73(1):33–37MATH Burke DW, O’Connor DO, Zalenski EB, Jasty M, Harris WH (1991) Micromotion of cemented and uncemented femoral components. J Bone Joint Surg Br 73(1):33–37MATH
34.
Zurück zum Zitat Schneider E, Kinast C, Eulenberger J, Wyder D, Eskilsson G, Perren SM (1989) A comparative study of the initial stability of cementless hip prostheses. Clin Orthop Relat Res 248:200–209 Schneider E, Kinast C, Eulenberger J, Wyder D, Eskilsson G, Perren SM (1989) A comparative study of the initial stability of cementless hip prostheses. Clin Orthop Relat Res 248:200–209
35.
Zurück zum Zitat Schneider E, Eulenberger J, Steiner W, Wyder D, Friedman RJ, Perren SM (1989) Experimental method for the in vitro testing of the initial stability of cementless hip prostheses. J Biomech 22(6–7):735–744CrossRef Schneider E, Eulenberger J, Steiner W, Wyder D, Friedman RJ, Perren SM (1989) Experimental method for the in vitro testing of the initial stability of cementless hip prostheses. J Biomech 22(6–7):735–744CrossRef
36.
Zurück zum Zitat Duparc J, Massin P (1992) Results of 203 total hip replacements using a smooth, cementless femoral component. J Bone Joint Surg Br 74(2):251–256 Duparc J, Massin P (1992) Results of 203 total hip replacements using a smooth, cementless femoral component. J Bone Joint Surg Br 74(2):251–256
37.
Zurück zum Zitat Dickob M, Martini T (1996) The cementless PM hip arthroplasty. Four-to-seven-year results. J Bone Joint Surg Br 78(2):195–199 Dickob M, Martini T (1996) The cementless PM hip arthroplasty. Four-to-seven-year results. J Bone Joint Surg Br 78(2):195–199
38.
Zurück zum Zitat Menon DK, McCreath SW (1999) 5- to 8-Year results of the freeman press-fit hip arthroplasty without HA coating: a clinicoradiologic study. J Arthroplasty 14(5):581–588CrossRef Menon DK, McCreath SW (1999) 5- to 8-Year results of the freeman press-fit hip arthroplasty without HA coating: a clinicoradiologic study. J Arthroplasty 14(5):581–588CrossRef
39.
Zurück zum Zitat Phillips TW, Messieh SS (1988) Cementless hip replacement for arthritis. Problems with a smooth surface moore stem. J Bone Joint Surg Br 70(5):750–755 Phillips TW, Messieh SS (1988) Cementless hip replacement for arthritis. Problems with a smooth surface moore stem. J Bone Joint Surg Br 70(5):750–755
40.
Zurück zum Zitat Dorr LD, Lewonowski K, Lucero M, Harris M, Wan Z (1997) Failure mechanisms of anatomic porous replacement I cementless total hip replacement. Clin Orthop Relat Res 334:157–167CrossRef Dorr LD, Lewonowski K, Lucero M, Harris M, Wan Z (1997) Failure mechanisms of anatomic porous replacement I cementless total hip replacement. Clin Orthop Relat Res 334:157–167CrossRef
41.
Zurück zum Zitat Kobayashi A, Donnelly WJ, Scott G, Freeman MA (1997) Early radiological observations may predict the long-term survival of femoral hip prostheses. J Bone Joint Surg Br 79(4):583–589CrossRef Kobayashi A, Donnelly WJ, Scott G, Freeman MA (1997) Early radiological observations may predict the long-term survival of femoral hip prostheses. J Bone Joint Surg Br 79(4):583–589CrossRef
42.
Zurück zum Zitat Vresilovic EJ, Hozack WJ, Rothman RH (1994) Radiographic assessment of cementless femoral components: correlation with intraoperative mechanical stability. J Arthroplasty 9(2):137–141CrossRef Vresilovic EJ, Hozack WJ, Rothman RH (1994) Radiographic assessment of cementless femoral components: correlation with intraoperative mechanical stability. J Arthroplasty 9(2):137–141CrossRef
43.
Zurück zum Zitat Khalily C, Whiteside LA (1998) Predictive value of early radiographic findings in cementless total hip arthroplasty femoral components: an 8- to 12-year follow-up. J Arthroplasty 13(7):768–773CrossRef Khalily C, Whiteside LA (1998) Predictive value of early radiographic findings in cementless total hip arthroplasty femoral components: an 8- to 12-year follow-up. J Arthroplasty 13(7):768–773CrossRef
44.
Zurück zum Zitat Kitamura S, Hasegawa Y, Iwasada S, Yamauchi K-i, Kawamoto K, Kanamono T, Iwata H (1999) Catastrophic failure of cementless total hip arthroplasty using a femoral component without surface coating. J Arthroplasty 14(8):918–924CrossRef Kitamura S, Hasegawa Y, Iwasada S, Yamauchi K-i, Kawamoto K, Kanamono T, Iwata H (1999) Catastrophic failure of cementless total hip arthroplasty using a femoral component without surface coating. J Arthroplasty 14(8):918–924CrossRef
45.
Zurück zum Zitat Lautiainen IA, Joukainen J, Makela EA (1994) Clinical and roentgenographic results of cementless total hip arthroplasty. J Arthroplasty 9(6):653–660CrossRef Lautiainen IA, Joukainen J, Makela EA (1994) Clinical and roentgenographic results of cementless total hip arthroplasty. J Arthroplasty 9(6):653–660CrossRef
46.
Zurück zum Zitat Petersilge WJ, D’Lima DD, Walker RH, Colwell CW Jr (1997) Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 4- to 8-year follow-up study. J Arthroplasty 12(2):185–193CrossRef Petersilge WJ, D’Lima DD, Walker RH, Colwell CW Jr (1997) Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 4- to 8-year follow-up study. J Arthroplasty 12(2):185–193CrossRef
47.
Zurück zum Zitat Mont MA, Hungerford DS (1997) Proximally coated ingrowth prostheses. A review. Clin Orthop Relat Res 344:139–149CrossRef Mont MA, Hungerford DS (1997) Proximally coated ingrowth prostheses. A review. Clin Orthop Relat Res 344:139–149CrossRef
48.
Zurück zum Zitat Chen CH, Shih CH, Lin CC, Cheng CK (1998) Cementless Roy-Camille femoral component. Arch Orthop Trauma Surg 118(1–2):85–88CrossRef Chen CH, Shih CH, Lin CC, Cheng CK (1998) Cementless Roy-Camille femoral component. Arch Orthop Trauma Surg 118(1–2):85–88CrossRef
49.
Zurück zum Zitat Kusakabe H, Sakamaki T, Nihei K, Oyama Y, Yanagimoto S, Ichimiya M, Kimura J, Toyama Y (2004) Osseointegration of a hydroxyapatite-coated multilayered mesh stem. Biomaterials 25(15):2957–2969CrossRef Kusakabe H, Sakamaki T, Nihei K, Oyama Y, Yanagimoto S, Ichimiya M, Kimura J, Toyama Y (2004) Osseointegration of a hydroxyapatite-coated multilayered mesh stem. Biomaterials 25(15):2957–2969CrossRef
50.
Zurück zum Zitat von Knoch M, Engh CA, Sychterz CJ, Engh CA, Willert H-G (2000) Migration of polyethylene wear debris in one type of uncemented femoral component with circumferential porous coating: an autopsy study of 5 femurs. J Arthroplasty 15(1):72–78 von Knoch M, Engh CA, Sychterz CJ, Engh CA, Willert H-G (2000) Migration of polyethylene wear debris in one type of uncemented femoral component with circumferential porous coating: an autopsy study of 5 femurs. J Arthroplasty 15(1):72–78
51.
Zurück zum Zitat Dorr LD, Wan Z (1996) Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the anatomic porous replacement II. J Arthroplasty 11(4):419–428CrossRef Dorr LD, Wan Z (1996) Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the anatomic porous replacement II. J Arthroplasty 11(4):419–428CrossRef
52.
Zurück zum Zitat Jacobsen S, Jensen FK, Poulsen K, Sturup J, Retpen JB (2003) Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5–11 years. Acta Orthop Scand 74(4):375–379 Jacobsen S, Jensen FK, Poulsen K, Sturup J, Retpen JB (2003) Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5–11 years. Acta Orthop Scand 74(4):375–379
53.
Zurück zum Zitat Yoshinari M, Matsuzaka K, Inoue T, Oda Y, Shimono M (2003) Effects of multigrooved surfaces on fibroblast behavior. J Biomed Mater Res A 65(3):359–368CrossRef Yoshinari M, Matsuzaka K, Inoue T, Oda Y, Shimono M (2003) Effects of multigrooved surfaces on fibroblast behavior. J Biomed Mater Res A 65(3):359–368CrossRef
54.
Zurück zum Zitat Matsuzaka K, Yoshinari M, Shimono M, Inoue T (2004) Effects of multigrooved surfaces on osteoblast-like cells in vitro: scanning electron microscopic observation and mRNA expression of osteopontin and osteocalcin. J Biomed Mater Res A 68A(2):227–234CrossRef Matsuzaka K, Yoshinari M, Shimono M, Inoue T (2004) Effects of multigrooved surfaces on osteoblast-like cells in vitro: scanning electron microscopic observation and mRNA expression of osteopontin and osteocalcin. J Biomed Mater Res A 68A(2):227–234CrossRef
55.
Zurück zum Zitat Matsuzaka K, Walboomers XF, Yoshinari M, Inoue T, Jansen JA (2003) The attachment and growth behavior of osteoblast-like cells on microtextured surfaces. Biomaterials 24(16):2711–2719CrossRef Matsuzaka K, Walboomers XF, Yoshinari M, Inoue T, Jansen JA (2003) The attachment and growth behavior of osteoblast-like cells on microtextured surfaces. Biomaterials 24(16):2711–2719CrossRef
56.
Zurück zum Zitat Chang CK, Wu JS, Mao DL, Ding CX (2001) Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4 V implants in tibia bone. J Biomed Mater Res 56(1):17–23CrossRef Chang CK, Wu JS, Mao DL, Ding CX (2001) Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4 V implants in tibia bone. J Biomed Mater Res 56(1):17–23CrossRef
57.
Zurück zum Zitat Eckardt A, Aberman HM, Cantwell HD, Heine J (2003) Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study. Arch Orthop Trauma Surg 123(1):28–35 Eckardt A, Aberman HM, Cantwell HD, Heine J (2003) Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study. Arch Orthop Trauma Surg 123(1):28–35
58.
Zurück zum Zitat Mouzin O, Soballe K, Bechtold JE (2001) Loading improves anchorage of hydroxyapatite implants more than titanium implants. J Biomed Mater Res 58(1):61–68CrossRef Mouzin O, Soballe K, Bechtold JE (2001) Loading improves anchorage of hydroxyapatite implants more than titanium implants. J Biomed Mater Res 58(1):61–68CrossRef
59.
Zurück zum Zitat Ricci JL, Spivak JM, Blumenthal NC, Alexander H (1991) The bone-biomaterial interface. Modulation of bone ingrowth by surface chemistry and roughness. University of Toronto Press, Ontario Ricci JL, Spivak JM, Blumenthal NC, Alexander H (1991) The bone-biomaterial interface. Modulation of bone ingrowth by surface chemistry and roughness. University of Toronto Press, Ontario
60.
Zurück zum Zitat Niki M, Ito G, Matsuda T, Ogino M (1991) The bone-biomaterial interface. Comparative push-out data of bioactive and non-bioactive materials of similar rugosity. University of Toronto Press, Ontario Niki M, Ito G, Matsuda T, Ogino M (1991) The bone-biomaterial interface. Comparative push-out data of bioactive and non-bioactive materials of similar rugosity. University of Toronto Press, Ontario
61.
Zurück zum Zitat Uchida A, Nade SM, McCartney ER, Ching W (1984) The use of ceramics for bone replacement. A comparative study of three different porous ceramics. J Bone Joint Surg Br 66(2):269–275 Uchida A, Nade SM, McCartney ER, Ching W (1984) The use of ceramics for bone replacement. A comparative study of three different porous ceramics. J Bone Joint Surg Br 66(2):269–275
62.
Zurück zum Zitat Yamamuro T, Takagi H (1991) The bone-biomaterial interface bone bonding behaviour of biomaterials with different surface characteristics under load-bearing conditions. University of Toronto Press, Ontario Yamamuro T, Takagi H (1991) The bone-biomaterial interface bone bonding behaviour of biomaterials with different surface characteristics under load-bearing conditions. University of Toronto Press, Ontario
63.
Zurück zum Zitat Jinno T, Kirk SK, Morita S, Goldberg VM (2004) Effects of calcium ion implantation on osseointegration of surface-blasted titanium alloy femoral implants in a canine total hip arthroplasty model. J Arthroplasty 19(1):102–109CrossRef Jinno T, Kirk SK, Morita S, Goldberg VM (2004) Effects of calcium ion implantation on osseointegration of surface-blasted titanium alloy femoral implants in a canine total hip arthroplasty model. J Arthroplasty 19(1):102–109CrossRef
64.
Zurück zum Zitat Gong W, Abdelouas A, Lutze W (2001) Porous bioactive glass and glass–ceramics made by reaction sintering under pressure. J Biomed Mater Res 54(3):320–327CrossRef Gong W, Abdelouas A, Lutze W (2001) Porous bioactive glass and glass–ceramics made by reaction sintering under pressure. J Biomed Mater Res 54(3):320–327CrossRef
65.
Zurück zum Zitat Kato H, Neo M, Tamura J, Nakamura T (2001) Bone bonding in bioactive glass ceramics combined with a new synthesized agent TAK-778. J Biomed Mater Res 57(2):291–299CrossRef Kato H, Neo M, Tamura J, Nakamura T (2001) Bone bonding in bioactive glass ceramics combined with a new synthesized agent TAK-778. J Biomed Mater Res 57(2):291–299CrossRef
66.
Zurück zum Zitat Kato H, Nishiguchi S, Furukawa T, Neo M, Kawanabe K, Saito K, Nakamura T (2001) Bone bonding in sintered hydroxyapatite combined with a new synthesized agent, TAK-778. J Biomed Mater Res 54(4):619–629CrossRef Kato H, Nishiguchi S, Furukawa T, Neo M, Kawanabe K, Saito K, Nakamura T (2001) Bone bonding in sintered hydroxyapatite combined with a new synthesized agent, TAK-778. J Biomed Mater Res 54(4):619–629CrossRef
67.
Zurück zum Zitat Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop Relat Res 355:200–211CrossRef Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop Relat Res 355:200–211CrossRef
68.
Zurück zum Zitat Røkkum M, Reigstad A (1999) Total hip replacement with an entirely hydroxyapatite-coated prosthesis: 5 years’ follow-up of 94 consecutive hips. J Arthroplasty 14(6):689–700CrossRef Røkkum M, Reigstad A (1999) Total hip replacement with an entirely hydroxyapatite-coated prosthesis: 5 years’ follow-up of 94 consecutive hips. J Arthroplasty 14(6):689–700CrossRef
69.
Zurück zum Zitat Ciccotti MG, Rothman RH, Hozack WJ, Moriarty L (1994) Clinical and roentgenographic evaluation of hydroxyapatite-augmented and nonaugmented porous total hip arthroplasty. J Arthroplasty 9(6):631–639CrossRef Ciccotti MG, Rothman RH, Hozack WJ, Moriarty L (1994) Clinical and roentgenographic evaluation of hydroxyapatite-augmented and nonaugmented porous total hip arthroplasty. J Arthroplasty 9(6):631–639CrossRef
70.
Zurück zum Zitat Rothman RH, Hozack WJ, Ranawat A, Moriarty L (1996) Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am 78(3):319–324 Rothman RH, Hozack WJ, Ranawat A, Moriarty L (1996) Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am 78(3):319–324
71.
Zurück zum Zitat Johnston DW, Davies DM, Beaupre LA, Lavoie G (2001) Standard anatomical medullary locking (AML) versus tricalcium phosphate-coated AML femoral prostheses. Can J Surg 44(6):421–427 Johnston DW, Davies DM, Beaupre LA, Lavoie G (2001) Standard anatomical medullary locking (AML) versus tricalcium phosphate-coated AML femoral prostheses. Can J Surg 44(6):421–427
72.
Zurück zum Zitat Kim YH, Kim JS, Oh SH, Kim JM (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85-A (9):1682–1688 Kim YH, Kim JS, Oh SH, Kim JM (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85-A (9):1682–1688
73.
Zurück zum Zitat Yee AJ, Kreder HK, Bookman I, Davey JR (1999) A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Clin Orthop Relat Res 366:120–132CrossRef Yee AJ, Kreder HK, Bookman I, Davey JR (1999) A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Clin Orthop Relat Res 366:120–132CrossRef
74.
Zurück zum Zitat Kang JS, Dorr LD, Wan Z (2000) The effect of diaphyseal biologic fixation on clinical results and fixation of the APR-II stem. J Arthroplasty 15(6):730–735CrossRef Kang JS, Dorr LD, Wan Z (2000) The effect of diaphyseal biologic fixation on clinical results and fixation of the APR-II stem. J Arthroplasty 15(6):730–735CrossRef
75.
Zurück zum Zitat Hayashi K, Mashima T, Uenoyama K (1999) The effect of hydroxyapatite coating on bony ingrowth into grooved titanium implants. Biomaterials 20(2):111–119CrossRef Hayashi K, Mashima T, Uenoyama K (1999) The effect of hydroxyapatite coating on bony ingrowth into grooved titanium implants. Biomaterials 20(2):111–119CrossRef
76.
Zurück zum Zitat Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH (1998) Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43(2):192–203CrossRef Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH (1998) Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43(2):192–203CrossRef
77.
Zurück zum Zitat Maloney WJ, Jasty M, Burke DW, O’Connor DO, Zalenski EB, Bragdon C, Harris WH (1989) Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling. Clin Orthop Relat Res 249:129–140 Maloney WJ, Jasty M, Burke DW, O’Connor DO, Zalenski EB, Bragdon C, Harris WH (1989) Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling. Clin Orthop Relat Res 249:129–140
78.
Zurück zum Zitat Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH (1992) Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res 285:13–29 Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH (1992) Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res 285:13–29
79.
Zurück zum Zitat Bernakiewicz M, Viceconti M, Toni A (2001) Investigation of the influence of periprosthetic fibrous tissue on the primary stability of uncemented hip prosthesis. Comput Meth Biomech Biomed Eng 3:21–26 Bernakiewicz M, Viceconti M, Toni A (2001) Investigation of the influence of periprosthetic fibrous tissue on the primary stability of uncemented hip prosthesis. Comput Meth Biomech Biomed Eng 3:21–26
80.
Zurück zum Zitat Viceconti M, Monti L, Muccini R, Bernakiewicz M, Toni A (2001) Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems. Clin Biomech (Bristol, Avon) 16(9):765–775 Viceconti M, Monti L, Muccini R, Bernakiewicz M, Toni A (2001) Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems. Clin Biomech (Bristol, Avon) 16(9):765–775
81.
Zurück zum Zitat Weinans H, Huiskes R, Grootenboer HJ (1993) Quantitative analysis of bone reactions to relative motions at implant-bone interfaces. J Biomech 26(11):1271–1281CrossRef Weinans H, Huiskes R, Grootenboer HJ (1993) Quantitative analysis of bone reactions to relative motions at implant-bone interfaces. J Biomech 26(11):1271–1281CrossRef
82.
Zurück zum Zitat O’Toole Iii RV, Jaramaz B, DiGioia Iii AM, Visnic CD, Reid RH (1995) Biomechanics for preoperative planning and surgical simulations in orthopaedics. Comput Biol Med 25(2):183–191CrossRef O’Toole Iii RV, Jaramaz B, DiGioia Iii AM, Visnic CD, Reid RH (1995) Biomechanics for preoperative planning and surgical simulations in orthopaedics. Comput Biol Med 25(2):183–191CrossRef
83.
Zurück zum Zitat Huiskes R, Verdonschot N, Nivbrant B (1998) Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop Relat Res 355:103–112CrossRef Huiskes R, Verdonschot N, Nivbrant B (1998) Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop Relat Res 355:103–112CrossRef
84.
Zurück zum Zitat McNamara BP, Cristofolini L, Toni A, Taylor D (1997) Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. J Biomech 30(6):621–630CrossRef McNamara BP, Cristofolini L, Toni A, Taylor D (1997) Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. J Biomech 30(6):621–630CrossRef
85.
Zurück zum Zitat Stolk J, Maher SA, Verdonschot N, Prendergast PJ, Huiskes R (2003) Can finite element models detect clinically inferior cemented hip implants? Clin Orthop Relat Res 409:138–150CrossRef Stolk J, Maher SA, Verdonschot N, Prendergast PJ, Huiskes R (2003) Can finite element models detect clinically inferior cemented hip implants? Clin Orthop Relat Res 409:138–150CrossRef
86.
Zurück zum Zitat Tanner KE, Yettram AL, Loeffler M, Goodier WD, Freeman MAR, Bonfield W (1995) Is stem length important in uncemented endoprostheses? Med Eng Phys 17(4):291–296CrossRef Tanner KE, Yettram AL, Loeffler M, Goodier WD, Freeman MAR, Bonfield W (1995) Is stem length important in uncemented endoprostheses? Med Eng Phys 17(4):291–296CrossRef
87.
Zurück zum Zitat Prendergast PJ (1997) Finite element models in tissue mechanics and orthopaedic implant design. Clin Biomech 12(6):343–366CrossRef Prendergast PJ (1997) Finite element models in tissue mechanics and orthopaedic implant design. Clin Biomech 12(6):343–366CrossRef
Metadaten
Titel
Introduction
verfasst von
Mohammed Rafiq Abdul Kadir
Copyright-Jahr
2014
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-38777-7_1

Neuer Inhalt