Skip to main content

2021 | OriginalPaper | Buchkapitel

18. Key Technology and Economic Analysis of Using Fujiang River Water as the Cooling and Heating Sources for Air Conditioning System

verfasst von : Zhang Wei, Fu Daoyou, Yao Mingqiang, Gan Shiyuan

Erschienen in: Sustainable Development of Water and Environment

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In order to use the river water, a new renewable energy, as the cooling and heating sources for the air conditioning system, the temperature, quality and quantity of water in the downstream of Fujiang River is analyzed; it is believed that it is suitable to use the properly processed river water as the cooling and heating sources for the air conditioning system. The floor area ratio in the riverside is relatively high and the building coverage ratio is large, and its horizontal and vertical distances to Fujiang River are short; therefore, those favorable conditions contribute to the application of the river water source heat pump air conditioning system. With a residential community in downstream of Fujiang River as the research object, the system mode and water intake method for the water resource heat pump air conditioning system are analyzed; it is believed that it is advantageous to adopt the open system and direct water intake method; referring to the existing performance model of the heat pump unit, the operation of the water resource heat pump system is optimized with the aim of high energy efficiency; it is further believed that the energy efficiency ratios in the heating and cooling seasons reach 4.12 and 4.42 respectively. Compared with the conventional air conditioning system, the energy cost saving rate for adopting the river water source heat pump unit is 23.78%. The harmful gas emission reductions are as follows: CO2: 3450.09t/a, SO2:14.58t/a, NO2:5.73t/a, smoke dust: 100.12t/a, with reduction amplitudes of 66%, 54%, 55% and 53% respectively. The application of river water source heat pump unit for water intake and discharge in the downstream of Fujiang River has little influence on water in Fujiang River. The research provides reference for the application of river water source heat pump air conditioning system in the downstream of Fujiang River.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Fan, Y.Q. 2010. Character analysis and program design of lake water-source heat pump system. Chongqing: Master Degree Thesis of Chongqing University, China Fan, Y.Q. 2010. Character analysis and program design of lake water-source heat pump system. Chongqing: Master Degree Thesis of Chongqing University, China
Zurück zum Zitat Fu SD, Liu JX, Lu GL et al (2007) Analysis of common problems in earth’ s surface water heat pump. Refrigeration, Air Conditioning & Electric Power Machinery 28(1):64–66 Fu SD, Liu JX, Lu GL et al (2007) Analysis of common problems in earth’ s surface water heat pump. Refrigeration, Air Conditioning & Electric Power Machinery 28(1):64–66
Zurück zum Zitat Huang Z, Liu XY, Huo JH et al (2008) Water-source heat pump system using water from Yangtze River in Chongqing. HV&AC 38(2):101–104 Huang Z, Liu XY, Huo JH et al (2008) Water-source heat pump system using water from Yangtze River in Chongqing. HV&AC 38(2):101–104
Zurück zum Zitat Huang GQ, Lu J, Wang L et al (2013) Transient condition model of heat pump unit with screw compressor based on data fitting. HV&AC 43(7):82–86 Huang GQ, Lu J, Wang L et al (2013) Transient condition model of heat pump unit with screw compressor based on data fitting. HV&AC 43(7):82–86
Zurück zum Zitat Li Y, Wang ZW (2006) Research on ways of water system of open–loop water source heat pump. Coal and Carbon Process 2006(8):95–97 Li Y, Wang ZW (2006) Research on ways of water system of open–loop water source heat pump. Coal and Carbon Process 2006(8):95–97
Zurück zum Zitat Wang GQ, Li M, Jin JL et al (2012) Variation trend of runoff in Fujiang River catchment and its responses to climate change. Journal of China Hydrology 32(1):22–28 Wang GQ, Li M, Jin JL et al (2012) Variation trend of runoff in Fujiang River catchment and its responses to climate change. Journal of China Hydrology 32(1):22–28
Zurück zum Zitat Wang Y, Xu HM, Cheng BY et al (2014) Impacts of precipitation change on the runoff change in the Fujiang River basin during the period of 1951-2012. Progressus Inquisitiones de Mutatione Climatis 10(22):127–134 Wang Y, Xu HM, Cheng BY et al (2014) Impacts of precipitation change on the runoff change in the Fujiang River basin during the period of 1951-2012. Progressus Inquisitiones de Mutatione Climatis 10(22):127–134
Zurück zum Zitat Xie, H.L., Liu, X.Y. and Lin, X.S. 2011.Testing and discussion on Yangtze River water-source heat pump air conditioning project of Chongqing in winter conditions. HV&AC, 41(11):74–76;91 Xie, H.L., Liu, X.Y. and Lin, X.S. 2011.Testing and discussion on Yangtze River water-source heat pump air conditioning project of Chongqing in winter conditions. HV&AC, 41(11):74–76;91
Zurück zum Zitat Zhang JY (2012) Based on the numerical simulation of river water source heat pump system of the technology of tail water discharge. Chongqing: Master Degree Thesis of Chongqing University, China Zhang JY (2012) Based on the numerical simulation of river water source heat pump system of the technology of tail water discharge. Chongqing: Master Degree Thesis of Chongqing University, China
Zurück zum Zitat Zhao QC (2006) Application prospect of the water- source- based heat- pump and some problems needing attention. Sci- tech Information Development & Economy 16(16):245–247 Zhao QC (2006) Application prospect of the water- source- based heat- pump and some problems needing attention. Sci- tech Information Development & Economy 16(16):245–247
Zurück zum Zitat Zhu JM, Xiang PZ (2007) Application of river water-source heat pump in the Shanghai Shiliupu reconstruction project. HV&AC 37(2):88–93 Zhu JM, Xiang PZ (2007) Application of river water-source heat pump in the Shanghai Shiliupu reconstruction project. HV&AC 37(2):88–93
Metadaten
Titel
Key Technology and Economic Analysis of Using Fujiang River Water as the Cooling and Heating Sources for Air Conditioning System
verfasst von
Zhang Wei
Fu Daoyou
Yao Mingqiang
Gan Shiyuan
Copyright-Jahr
2021
DOI
https://doi.org/10.1007/978-3-030-75278-1_18