Abstract
Two-point velocity correlation measurements were made in the anisotropic flow field of an axisymmetric sudden expansion using two single component LDV systems. The integral length scales and Taylor microscales were estimated and compared with those obtained from auto correlation measurements in conjunction with Taylor's hypothesis. The agreement of the integral scales was within 20% and the values scale well with the flow geometry, while the agreement of the microscales was within 43%.
Similar content being viewed by others
References
Gould RD; Benedict LH (1992) A comparison of spatial correlation and autocorrelation measurements in an axisymmetric sudden expansion flow using LDV, The 13th Symposium on Turbulence, Rolla, Missouri, Sept. 21–23
Hinze JO (1975) Turbulence. McGraw-Hill
Mayo WT; Shay MT; Ritter S (1974) The development of new digital data processing techniques for turbulence measurements with laser velocimetry. AEDC-TR-74-53
Srikantaiah DV; Coleman HW (1985) Turbulence spectra from individual realization laser velocimetry data. Exp Fluids 3: 35–44
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Gould, R.D., Benedict, L.H. Comparison of length scale estimates for a sudden expansion flow estimated from spatial and auto correlation LDV measurements. Experiments in Fluids 17, 285–287 (1994). https://doi.org/10.1007/BF00203049
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00203049