Skip to main content
Log in

Comparison of Monte Carlo simulations of photon/electron dosimetry in microscale applications

  • Technical Report
  • Published:
Australasian Physics & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

It is important to establish reliable calculational tools to plan and analyse representative microdosimetry experiments in the context of microbeam radiation therapy development. In this paper, an attempt has been made to investigate the suitability of the MCNP4C Monte Carlo code to adequately model photon/electron transport over micron distances. The case of a single cylindrical microbeam of 25-micron diameter incident on a water phantom has been simulated in detail with both MCNP4C and the code PSI-GEANT, for different incident photon energies, to get absorbed dose distributions at various depths, with and without electron transport being considered. In addition, dose distributions calculated for a single microbeam with a photon spectrum representative of the European Synchrotron Radiation Facility (ESRF) have been compared. Finally, a large number of cylindrical microbeams ( a total of 2601 beams, placed on a 200-micron square pitch, covering an area of 1cm2) incident on a water phantom have been considered to study cumulative radial dose distributions at different depths. From these distributions, ratios of peak (within the microbeam) to valley (mid-point along the diagonal connecting two microbeams) dose values have been determined. The various comparisons with PSI-GEANT results have shown that MCNP4C, with its high flexibility in terms of its numerous source and geometry description options, variance reduction methods, detailed error analysis, statistical checks and different tally types, can be a valuable tool for the analysis of microbeam experiments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Slatkin, D. N., Spanne, P. O., Dilmanian, F. A. and Sandborg, M.,Microbeam radiation therapy, Med. Phys. 19, 1395–1400, 1992.

    Article  CAS  PubMed  Google Scholar 

  2. Dilmanian, F. A., Wu, X. Y., Huang, X., Kershaw, M., Ren, B., Slatkin, D. N., Trandem, K., Menk, R., Thomlinson, W. C. and Zhong, Z.,Microbeam irradiation of duck embryo brains: Relevance to microbeam radiation therapy [MRT] of brain tumors in infants, 1996 NSLS Activity Report, E.Z. Rothman and J. B. Hastings eds.), BNL 52517, B-140, 1997.

  3. Laissue, J. A., Lyubimova, N., Wagner, H. P., Archer, D. W., Slatkin, D. N., Michiel, M. Di., Namoz, C., Renier, M., Brauer, E., Spanne, P.O., Gebbers, J. O., Dixon, K. and Blattmann, H.,Microbeam radiation therapy, SPIE Conference on Medical Applications of Penetrating Radiation Denver, Colorado, 38–45, July 1999.

  4. Slatkin, D. N., Dilmanian, F. A., Nawrocky, M. M., Spanne, P.O., Gebbers, J. O., Archer, D. W. and Laissue, J. A.,Design of a multislit, variable width collimator for microplanar beam radiotherapy, Rev. Sci. Instrum. 66, 1459–1460, 1995.

    Article  CAS  Google Scholar 

  5. Archer, D. W.,Collimator for producing an array microbeams, U.S. Patent No. 5771270, June23, 1998.

  6. Rosenfeld, A. B., Kaplan, G. I., Kron, I., Allen, B., Dilmanian, F. A., Orion, I., Ren, B., Lerch, B. M. and Holmes-Siedle, A.,MOSFET dosimetry of an X-ray microbeam, IEEE Trans. Nucl. Sci. Vol. 46(6), 1774–80, 1999.

    Article  CAS  Google Scholar 

  7. Rosenfeld, A. B., Lerch, B. M., Kron, T., Brauere-Kirch, E., Bravin, A., Siedle, A. H. and Allen, B. J.,Feasibility study of online high-spatial resolution MOSFET dosimetry in static and pulsed X-ray radiation fields, IEEE Transactions on Nucl. Sci. Vol. 48, No. 6, December 2001.

  8. Stepanek, J., Blattmann, H., Laissue, J. A., Lyubimova, N., Michiel, M. Di. and Slatkin, D. N.,Physics study of microbeam radition therapy with psi-version of Monte-Carlo code GEANT as a new computational tool, Med. Phys. 27(7), July 2000.

  9. Orion, I., Rosenfeld, A. B., Dilmanian, F. A., Telang, F., Ren, B. and Namito, Y.,Monte Carlo simulation of dose distributions from a synchrotron-produced mcroplanar beam array using the EGS4 code system, Phys. Med. Biol. 45, 2497–2508, 2000.

    Article  CAS  PubMed  Google Scholar 

  10. Briesmeister, J. F., (edt),MCNP™ — A General Monte Carlo N-Particle Transport Code Version-4C, LA-13709-M, March 2000.

  11. Zilio, V. O.,Monte Carlo predictions of dose in the radiation treatment of prostate cancer, Diplôme d’ingénieur-physicien, EPFL, Octobre 2000-Février 2001.

  12. GEANT team,GEANT version 3.15, CERN data handling Division, DD/EE/84-1, revision 1992.

  13. Bravin, A. and Brauer, E.,European Synchrotron Radiation facility, Private Communication.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to O. P. Joneja.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Joneja, O.P., Negreanu, C., Stepanek, J. et al. Comparison of Monte Carlo simulations of photon/electron dosimetry in microscale applications. Australas. Phys. Eng. Sci. Med. 26, 62–68 (2003). https://doi.org/10.1007/BF03178459

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03178459