Abstract

The effectiveness of passive energy dissipation systems to improve seismic performance of connected buildings is now well established through extensive analytical and experimental investigations. However, the performance of buildings connected with friction dampers has not been looked into. In this paper, the investigation is carried out to study the structural responses of two adjacent buildings connected with friction dampers under various earthquake excitations. A formulation of the equations of motion for the two adjacent multi degree of freedom (MDOF) buildings connected with friction dampers is presented. The numerical study is carried out in two parts, namely (i) two adjacent MDOF buildings connected with friction dampers having same slip force in all the dampers and (ii) two adjacent MDOF buildings connected with friction dampers having different slip forces in the dampers. The effectiveness of the dampers in terms of the reduction of structural responses, namely, displacement, acceleration and shear forces of connected adjacent buildings is investigated. A parametric study is also conducted to investigate the optimum slip force of the dampers. In addition, the optimal placement of the dampers, rather than providing the dampers at all the floor levels is also studied to minimize the cost of the dampers. Results show that using friction dampers to connect the adjacent buildings of different fundamental frequencies can effectively reduce earthquake-induced responses of either building if slip force of the dampers is appropriately selected. Also, it is not necessary to connect the two adjacent buildings at all floors but lesser dampers at appropriate locations can significantly reduce the earthquake response of the combined system. Further, it is also observed that the reduction in the responses when the two MDOF buildings connected with 50% of the total dampers is almost as much as when they are connected at all the floors, thereby reducing the cost of the dampers significantly.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Carolina, T. and Lopez, O.A. (2004) Effect of the position and number of dampers on the seismic response of frame structure. Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper no: 1044.

  • P. Colajanni M. Papia (1995) ArticleTitleSeismic response of braced frames with and without friction dampers Engineering Structures. 17 129–140 Occurrence Handle10.1016/0141-0296(95)92644-N

    Article  Google Scholar 

  • M.C. Constantinou A.M. Reinhorn A. Mokha R. Watson (1991) ArticleTitleDisplacement control device for base isolation of bridges Earthquake Spectra. 7 179–200 Occurrence Handle10.1193/1.1585625

    Article  Google Scholar 

  • Li, C. and Reinhorn, A.M. (1995) Experimental and analytical investigation of seismic retrofit of structures with supplemental damping: part II-friction damping devices. Report No. NCEER-95-0009. National Center for Earthquake Engineering Research, State University of New York at Buffalo, USA.

  • J.E. Luco F.C.P. Barros ParticleDe (1998) ArticleTitleOptimal damping between two adjacent elastic structures Earthquake Engineering and Structural Dynamics 27 649–659

    Google Scholar 

  • I.H. Mualla B. Belev (2002) ArticleTitlePerformance of steel frames with a new friction damper device under earthquake excitation Engineering Structures. 24 365–371 Occurrence Handle10.1016/S0141-0296(01)00102-X

    Article  Google Scholar 

  • Y.Q. Ni J.M. Ko Z.G. Ying (2001) ArticleTitleRandom seismic response analysis of adjacent buildings coupled with non-linear hysteretic dampers Journal of Sound and Vibration. 246 403–417 Occurrence Handle10.1006/jsvi.2001.3679

    Article  Google Scholar 

  • Pasquin, C., Leboeuf, N., Pall, R.N. and Pall, A. (2004) Friction dampers for seismic rehabilitation of Eaton’s building, Montreal. Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper no: 1949.

  • W.L. Qu Z.H. Chen Y.L. Xu (2001) ArticleTitleDynamic analysis of wind-excited truss tower with friction dampers Computers and Structures. 79 2817–2831

    Google Scholar 

  • A.M. Reinhorn R.E. Valles (1995) Damage evaluation in inelastic response of structures: a deterministic approach State University of New York at Buffalo USA

    Google Scholar 

  • A. Vafai M. Hamidi G. Ahmadi (2001) ArticleTitleNumerical modeling of MDOF structures with sliding supports using rigid-plastic link Earthquake Engineering and Structural Dynamics. 30 27–42 Occurrence Handle10.1002/1096-9845(200101)30:1<27::AID-EQE992>3.0.CO;2-H

    Article  Google Scholar 

  • B. Westermo (1989) ArticleTitleThe dynamics of inter-structural connection to prevent pounding Earthquake Engineering and Structural Dynamics. 18 687–699

    Google Scholar 

  • Y.L. Xu Q. He J.M. Ko (1999) ArticleTitleDynamic response of damper-connected adjacent buildings under earthquake excitation Engineering Structures. 21 135–148 Occurrence Handle10.1016/S0141-0296(97)00154-5

    Article  Google Scholar 

  • Y.B. Yang T.Y. Lee I.C. Tsai (1990) ArticleTitleResponse of multi-degree-of-freedom structures with sliding supports Earthquake Engineering and Structural Dynamics. 19 739–752

    Google Scholar 

  • W.S. Zhang Y.L. Xu (1999) ArticleTitleDynamic characteristics and seismic response of adjacent buildings linked by discrete dampers Earthquake Engineering and Structural Dynamics. 28 1163–1185

    Google Scholar 

  • W.S. Zhang Y.L. Xu (2000) ArticleTitleVibration analysis of two buildings linked by Maxwell Model-defined Fluid Dampers Journal of Sound and Vibration 233 775–796 Occurrence Handle10.1006/jsvi.1999.2735

    Article  Google Scholar 

  • H.P. Zhu H. Iemura (2000) ArticleTitleA study of response control on the passive coupling element between two parallel structures Structural Engineering and Mechanics. 9 383–396

    Google Scholar 

  • H.P. Zhu Y.L Xu (2005) ArticleTitleOptimum parameters of Maxwell model-defined dampers used to link adjacent structures Journal of Sound and Vibration. 279 253–274

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. S. Jangid.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bhaskararao, A.V., Jangid, R.S. Seismic Response of Adjacent Buildings Connected with Friction Dampers. Bull Earthquake Eng 4, 43–64 (2006). https://doi.org/10.1007/s10518-005-5410-1

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-005-5410-1

Keywords

Navigation