Abstract
Progress in microfabricated technologies has attracted the attention of researchers in several areas, including microcirculation. Microfluidic devices are expected to provide powerful tools not only to better understand the biophysical behavior of blood flow in microvessels, but also for disease diagnosis. Such microfluidic devices for biomedical applications must be compatible with state-of-the-art flow measuring techniques, such as confocal microparticle image velocimetry (PIV). This confocal system has the ability to not only quantify flow patterns inside microchannels with high spatial and temporal resolution, but can also be used to obtain velocity measurements for several optically sectioned images along the depth of the microchannel. In this study, we investigated the ability to obtain velocity measurements using physiological saline (PS) and in vitro blood in a rectangular polydimethysiloxane (PDMS) microchannel (300 μm wide, 45 μm deep) using a confocal micro-PIV system. Applying this combination, measurements of trace particles seeded in the flow were performed for both fluids at a constant flow rate (Re = 0.02). Velocity profiles were acquired by successive measurements at different depth positions to obtain three-dimensional (3-D) information on the behavior of both fluid flows. Generally, the velocity profiles were found to be markedly blunt in the central region, mainly due to the low aspect ratio (h/w = 0.15) of the rectangular microchannel. Predictions using a theoretical model for the rectangular microchannel corresponded quite well with the experimental micro-PIV results for the PS fluid. However, for the in vitro blood with 20% hematocrit, small fluctuations were found in the velocity profiles. The present study clearly shows that confocal micro-PIV can be effectively integrated with a PDMS microchannel and used to obtain blood velocity profiles along the full depth of the microchannel because of its unique 3-D optical sectioning ability. Advantages and disadvantages of PDMS microchannels over glass capillaries are also discussed.
Similar content being viewed by others
References
R. Adrian, Annu. Rev. Fluid Mech. 23, 261–304 (1991)
C. Alonso, A. Pries, O. Kiesslich, D. Lerche, P. Gaehtgens, Am. J. Physiol. 268(1 Pt 2), H25–H32 (1995)
M. Baker, H. Wayland, Microvasc. Res. 7, 131–143 (1974)
D. Beebe, G. Mensing, G. Walker, Annu. Rev. Biomed. Eng. 4, 261–286 (2002)
L. Bitsch, L. Olesen, C. Westergaard, H. Bruus, H. Klank, J. Kutter, Exp. Fluids 39, 505–511 (2005)
J. Borenstein, H. Terai, K. King, E. Weinberg, M. Kaazempur-Mofrad, J. Vacanti, Biomedical Microdevices 4(3), 167–175 (2002)
G. Born, A. Melling, J. Whitelaw, Biorheology 15, 163–172 (1978)
T. Brown, J. Biomech. 33, 3–14 (2000)
H. Bruus, Theoretical microfluidics (MIC, Technical University of Denmark, Denmark, 2004)
G. Bugliarello, J. Hayden, Trans. Soc. Rheol. 7, 209–230 (1963)
C. Caro, T. Pedley, R. Schroter, W. Seed, The mechanics of the circulation (Oxford University Press, 1978)
W. Chang, D. Akin, M. Sedlak, M. Ladisch, R. Bashir, Biomedical Microdevices 5(4), 281–290 (2003)
S. Chien, S. Usami, R. Skalak, Blood flow in small tubes Handbook of Physiology – The cardiovascular system IV (1984) 217–249
T. Cochrane, J. Earnshaw, A. Love, Med. Biol. Eng. Comput. 19, 589–596 (1981)
C. Duffy, J. McDonald, O. Schueller, G. Whitesides, Anal. Chem. 70, 4974–4984 (1998)
S. Einav, R. Berman, P. Fuhro, P. DiGiovanni, S. Fine, J. Fridman, Biorheology 12, 207–210 (1975)
R. Fahraeus, T. Lindqvist, Am. J. Physiol. 96, 562–568 (1931)
M. Faivre, M. Abkarian, K. Bickraj, H. Stone, Biorheology 43, 147–159 (2006)
T. Fujii, Microelectron. Eng. 61–62, 907–914 (2002)
P. Gaehtgens, Biorheology 24, 367–376 (1987)
P. Gaehtgens, H. Meiselman, H. Wayland, Microvasc. Res. 2, 13–23 (1970)
S. Gifford, M. Frank, J. Derganc, C. Gabel, R. Austin, T. Yoshida, W. Bitensky, Biophys. J. 84, 623–633 (2003)
H. Goldsmith, V. Turitto, Tromb. Haemost. 55, 415–435 (1986)
H. Golster, M. Linden, S. Bertuglia, A. Colantuoni, G. Nilsson, F. Sjoberg, Microvasc. Res. 58, 62–73 (1999)
R. Gomez, R. Bashir, A. Sarikaya, M. Ladish, J. Sturgis, J. Robison, T. Geng, A. Bhunia, H. Apple, S. Wereley, Biomedical Microdevices 3(3), 201–209 (2001)
G. Holzapfel, G. Sommer, C. Gasser, P. Regitnig, Am. J. Physiol Heart Circ. Physiol. 289, H2048–H2058 (2005)
H. Kaji, T. Kawashima, M. Nishizawa, Langmuir 22, 10784–10787 (2006)
G.B. Kim, S.J. Lee, Exp Fluids 41, 195–200 (2006)
H. Kinoshita, M. Oshima, S. Kaneda, T. Fujii, Proceedings of the 9thICMSCLS (Boston, Massachusetts, USA, 2005)
A. Koutsiaris, D. Mathioulakis, S. Tsangaris, Meas. Sci. Technol. 10, 1037–1046 (1999)
R. Lima, Analysis of the blood flow behavior through microchannels by confocal micro-PIV/PTV system, Doctoral thesis (Tohoku University, Japan, 2007)
R. Lima, S. Wada, K. Tsubota, T. Yamaguchi, Proceedings of the 3rd IASTED ICB—BioMech (Benidorm, Spain, 485, 2005)
R. Lima, S. Wada, K. Tsubota, T. Yamaguchi, Meas. Sci. Technol. 17, 797–808 (2006)
R. Lima, S. Wada, M. Takeda, K. Tsubota, T. Yamaguchi, J. Biomech. 40, 2752–2757 (2007)
N. Maeda, Jpn. J. Physiol 46, 1–14 (1996)
A. Mata, A. Fleischman, S. Roy, Biomedical Microdevices 7(4), 281–293 (2005)
J. McDonald, G. Whitesides, Acc. Chem. Res 35(7), 491–499 (2002)
G. Mchedlishvili, N. Maeda, Jpn. J. Physiol 51, 19–30 (2001)
C. Meinhart, S. Wereley, J. Santiago, J. Fluids Eng 122, 285–289 (2000)
G. Minas, J. Martins, J. Ribeiro, R. Wolffenbuttel, J. Correia, Sens. Actuators 110, 33–38 (2004)
J. Moger, S. Matcher, C. Winlove, A. Shore, J. Biomed. Opt. 9(5), 982–994 (2004)
N. Mortensen, F. Okkels, H. Bruus, Phys. Rev. E 71, 1–4 (2005)
A. Nakano, Y. Sugii, M. Minamiyama, H. Niimi, Clin. Hemorheol. Microcirc. 29, 445–455 (2003)
N. Nguyen, S. Wereley, Fundamentals and applications of microfluidics (Artech House, Inc., Norwood, MA, 2002)
J. Park, K. Kihm, Opt. Lasers Eng. 44, 208–223 (2006)
J. Park, C. Choi, K. Kihm, Exp. Fluids 37, 105–119 (2004)
A. Parthasarathi, S. Japee, R. Pittman, Ann Biomed. Eng. 27, 313–325 (1999)
A. Pries, T. Secomb, Clin. Hemorheol. Microcirc. 29, 143–148 (2003)
A. Pries, T. Secomb, T. Gessner, M. Sperandio, J. Gross, P. Gaehtgens, Circ. Res. 75, 904–915 (1994)
M. Raffel, C. Willert, J. Kompenhans, Particle image velocimetry: a practical guide (Springer, Germany, 1998)
Rika nenpyo, Chronological scientific tables, (National Astronomical Observatory), Maruzen Co., Japan, 1996
J. Santiago, S. Wereley, C. Meinhart, D. Beebe, R. Adrian, Exp Fluids 25, 316–319 (1998)
T. Secomb, Symp. Soc. Exp. Biol. vol 49 (London, UK, 1995), pp. 305–321
S. Shevkoplyas, S. Gifford, T. Yoshida, M. Bitensky, Microvasc. Res. 65, 132–136 (2003)
M. Shin, K. Matsuda, O. Ishii, H. Terai, M. Kaazempur-Mofrad, J. Borenstein, M. Detmar, J. Vacanti, Biomedical Microdevices 6(4), 269–278 (2004)
H. Steiger, R. Aaslid, S. Keller, H. Reulen, Heart Vessels 5(1), 41–46 (1989)
N. Sutton, M. Tracey, I. Johnston, R. Greenaway, M. Rampling, Microvasc. Res. 53, 272–281 (1997)
Y. Suzuki, N. Tateishi, M. Soutani, N. Maeda, Microcirculation 3, 49–57 (1996)
P. Tabeling, Proceedings of the 14th Australasian Fluid Mechanics Conference (Adelaide, Australia, 2001)
S. Takayama, J. McDonald, E. Ostuni, M. Liang, P. Kenis, F. Ismagilov, G. Whitesides, Patterning cells and their environments using multiple laminar fluid flows in capillary networks Proc. Natl. Acad. Sci. 96, 5545–5548 (1999)
T. Tanaani, S. Otsuki, N. Tomosada, Y. Kosugi, M. Shimizu, H. Ishida, Appl. Opt. 41(22), 4704–4708 (2002)
G. Tangelder, D. Slaaf, M. Muijtjens, T. Arts, M. Egbrink, R. Reneman, Circ. Res. 59, 505–514 (1986)
T. Thorsen, S. Maerkl, S. Quake, Science 298, 580–584 (2002)
M. Toner, D. Irimia, Annu. Rev. Biomed. Eng. 7, 77–103 (2005)
K. Tsukada, H. Minamitami, E. Sekizuka, C. Oshio, Physiol. Meas. 21(4), 459–471 (2000)
W. Uijttewaal, E. Nijhof, R. Heethaar, J. Biomech. 27, 35–42 (1994)
M. Unger, H. Chou, T. Thorsen, A. Scherer, S. Quake, Science 288, 113–116 (2000)
P. Vennemann, K. Kiger, R. Lindken, B. Groenendijk, S. Stekelenburg-de Vos, T. Hagen, N. Ursem, R. Poelmann, J. Westerweel, B. Hierk, J. Biomech. 39, 1191–1200 (2006)
S. Wilhelm, B. Grobler, M. Gluch, H. Heinz, Confocal laser scanning microscopy: principles (Carl Zeiss, Germany, 2003)
C. Willert, M. Raffel, J. Kompenhans, B. Stasicki, C. Kahler, Flow Meas. Instrum. 7, 247–256 (1996)
Acknowledgements
This study was supported in part by the following grants: International Doctoral Program in Engineering from the Ministry of Education, Culture, Sports, Science and Technology of Japan (MEXT), “Revolutionary Simulation Software (RSS21)” next-generation IT program of MEXT; Grants-in-Aid for Scientific Research from MEXT and JSPS Scientific Research in Priority Areas (768) “Biomechanics at Micro- and Nanoscale Levels,” Scientific Research (A) No.16200031 “Mechanism of the formation, destruction, and movement of thrombi responsible for ischemia of vital organs”. The authors also thank all members of Esashi, Ono and Tanaka Lab. for their assistance in fabricating the PDMS microchannel.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lima, R., Wada, S., Tanaka, S. et al. In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system. Biomed Microdevices 10, 153–167 (2008). https://doi.org/10.1007/s10544-007-9121-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10544-007-9121-z