Abstract
The surface electromyography (sEMG) signal separation and decphompositions has always been an interesting research topic in the field of rehabilitation and medical research. Subtle myoelectric control is an advanced technique concerned with the detection, processing, classification, and application of myoelectric signals to control human-assisting robots or rehabilitation devices. This paper reviews recent research and development in independent component analysis and Fractal dimensional analysis for sEMG pattern recognition, and presents state-of-the-art achievements in terms of their type, structure, and potential application. Directions for future research are also briefly outlined.
Similar content being viewed by others
References
ICA based identification of sources in sEMG (2007) doi:10.1109/ISSNIP.2007.4496914
Acharya Bhat SP, Kannathal N, Rao A, Lim CM (2005) Analysis of cardiac health using fractal dimension and wavelet transformation. ITBM-RBM 26(2):133–139
Akujuobi C, Baraniecki A (1992) Wavelets and fractals: a comparative study. Statistical signal and array processing, 1992. Conference proceedings., IEEE sixth SP workshop on pp. 42–45
Anmuth CJ, Goldberg G, Mayer NH (1994) Fractal dimension of electromyographic signals recorded with surface electrodes during isometric contractions is linearly correlated with muscle activation. Muscle Nerve 17(8):953–954
Arjunan SP, Kumar DK (2007) Fractal based modelling and analysis of electromyography (EMG) to identify subtle actions. 29th Annual international conference of the IEEE engineering in medicine and biology society pp. 1961–1964
Attias H, Schreiner CE (1998) Blind source separation and deconvolution: the dynamic component analysis algorithm. Neural Comput 10(6):1373–1424
Azzerboni B, Carpentieri M, La Foresta F, Morabito FC (2004) Neural-ICA and wavelet transform for artifacts removal in surface EMG. In: Neural networks, 2004. Proceedings. 2004 IEEE international joint conference on 4:3223–3228
Azzerboni B, Finocchio G, Ipsale M, La Foresta F, Mckeown MJ, Morabito FC (2002) Spatio-temporal analysis of surface electromyography signals by independent component and time-scale analysis. In: Engineering in medicine and biology, 2002. 24th Annual conference and the annual fall meeting of the biomedical engineering society. EMBS/BMES conference, 2002. Proceedings of the 2nd joint 1:112–113. doi:10.1109/IEMBS.2002.1134411
Baris N (2007) The adaptive ARMA analysis of EMG signals. J Med Sys 32(1):43–50
Barlow JS (1979) Computerized clinical electroencephalography in perspective. IEEE Trans Biomed Eng BME-26(7):377–391. doi:10.1109/TBME.1979.326416
Bartolo A, Roberts C, Dzwonczyk RR, Goldman E (1996) Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ecg contamination. J Appl Physiol 80(6):1898–1902
Basmajian Deluca C (1985) Muscles alive: their functions revealed by electromyography, 5th edn. Williams & Wilkins, Baltimore, USA
Bassingthwaighte J, Liebovitch L, West B (1994) Fractal physiology. Oxford University Press, New York
Bourke P (2007) Self similarity. Fractals, Chaos URL http://local.wasp.uwa.edu.au/~pbourke/fractals/selfsimilar/
Calinon S, Billard A (2005) Recognition and reproduction of gestures using a probabilistic framework combining PCA, ICA and HMM. In: ICML ’05: Proceedings of the 22nd international conference on machine learning, pp. 105–112. ACM. doi:10.1145/1102351.1102365
Carlin M (2000) Measuring the complexity of non-fractal shapes by a fractal method. Patt Recog Lett 21(11):1013–1017
Chen B, Wang N (2000) Determining EMG embedding and fractal dimensions and its application. In: Engineering in medicine and biology society, 2000. Proceedings of the 22nd annual international conference of the IEEE 2:1341–1344
Christodoulou CI, Pattichis CS (1999) Unsupervised pattern recognition for the classification of EMG signals. IEEE Trans Biomed Eng 46(2):169–178
Coatrieux JL, Toulouse P, Rouvrais B, Bars RL (1983) Automatic classification of electromyographic signals. EEG Clin Neurophysiol 55:333–341
Cram J, Kasman G, Holtz J (1998) Introduction to surface electromyography. Aspen Publishers Inc., Gaithersburg, Maryland
Crawford B, Miller K, Shenoy P, Rao R (2005) Real-time classification of electromyographic signals for robotic control. Tech rep, University of Washington
De Luca C (2006) Electromyography. Encyclopedia of medical devices and instrumentation. Wiley, Indianapolis, pp. 98–109
Devaney RL (1995) Chaos in the classroom. Mathematics and statistics at Boston University. URL http://math.bu.edu/DYSYS/chaos-game/chaos-game.html
Djuwari D, Kumar D, Raghupati S, Polus B (2003) Multi-step independent component analysis for removing cardiac artefacts from back sEMG signals. In: ANZIIS, pp. 35–40
Duchêne J, Goubel F (1993) Surface electromyogram during voluntary contraction: processing tools and relation to physiological events. Crit Rev Biomed Eng 21(4):313–397
Durgam V, Fernandes G, Preiszl H, Lutzenberger W, Pulvermuller F, Birbaumer N (1997) Fractal dimensions of short eeg time series in humans. Neurosci Lett 225(2):77–80. doi:10.1109/TNSRE.2007.908376
Enderle J, Blanchard SM, Bronzino J (eds) (2005) Introduction to Biomedical Engineering, 2nd edn. Academic Press, New York
Englehart K, Hudgins B (2003) A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng 50(7):848–854
Esteller R, Vachtsevanos G, Echauz J, Litt B (2001) A comparison of waveform fractal dimension algorithms. Circuits and systems I: fundamental theory and applications, IEEE Transactions on see also Circuits and Systems I: Regular Papers, IEEE Trans on. 48(2):177–183. doi:10.1109/81.904882
Falconer K (1990) Fractal geometry—mathematical foundations and applications. Wiley, New York
Farina D, Merletti R, Stegeman DF (2005) Biophysics of the Generation of EMG Signals, Electromyography. Wiley-IEEE Press, USA, pp. 81–105
Feder J (1988) Fractals. Plenum Press, New York
Gitter JA, Czerniecki MJ (1995) Fractal analysis of the electromyographic interference pattern. J Neurosci Method 58(1):103–108. doi:10.1016/0165-0270(94)00164-C
Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PC, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE (2000) PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation 101(23):e215–e220 . Circulation Electronic Pages:http://circ.ahajournals.org/cgi/content/full/101/23/e215
Graupe D, Cline WK (1975) Functional separation of sEMG signals via arma identification methods for prosthesis control purposes. IEEE Trans Sys, Man, Cybern 5(2):252–259
Green ER (1998) Understanding fractals and fractal dimensions. Senior honor thesis—University of Wisconsin, Madison, WI. URL http://pages.cs.wisc.edu/~ergreen/honors_thesis/similar.html
Gupta V, Suryanarayanan S, Reddy NP (1997) Fractal analysis of surface EMG signals from the biceps. Int J Med Inform 45(3):185–192. doi:10.1016/S1386-5056(97)00029-4
Hämäläinen M, Hari R, Ilmoniemi RJ, Knuutila J, Lounasmaa OV (1993) Magnetoencephalography-151; theory, instrumentation, and applications to noninvasive studies of the working human brain. Rev Modern Phys 65(2):413–497
Hansen (2000) Blind separation of noicy image mixtures. Springer, Berlin, pp. 159–179
He T, Clifford G, Tarassenko L (2006) Application of independent component analysis in removing artefacts from the electrocardiogram. Neural Comput Appl 15(2):105–116 doi:10.1007/s00521-005-0013-y
Higuchi T (1988) Approach to an irregular time series on the basis of the fractal theory. Phys D 31(2):277–283
Hillyard SA, Galambos R (1970) Eye movement artefact in the cnv. Electroencephalogr Clin Neurophysiol 28(2):173–182
Hu X, Wang ZZ, Ren XM (2005) Classification of surface EMG signal with fractal dimension. J Zhejiang Univ Sci B 6(8):844–848
Hu Y, Mak J, Liu H, Luk KDK (2007) Ecg cancellation for surface electromyography measurement using independent component analysis. In: Circuits and Systems, 2007. ISCAS 2007. IEEE International Symposium on :3235–3238. doi:10.1109/ISCAS.2007.378161
Hyvarinen A, Cristescu R, Oja E (1999) A fast algorithm for estimating overcomplete ICA bases for image windows. In: Neural networks, 1999. IJCNN ’99. International joint conference on 2:894–899. doi:10.1109/IJCNN.1999.831071
Hyvarinen A, Karhunen J, Oja E (2001) Independent component analysis. Wiley-Interscience, London
Hyvärinen A, Oja E (2000) Independent component analysis: algorithms and applications. Neural Netw 13(4-5):411–430
Iannaconne P, Khokha M (1996) Fractal geometry in biological systems: an analytical approach. CRC Press, Boca Raton
Ivanov PC, Amaral LAN, Goldberger AL, Stanley HE (1998) Stochastic feedback and the regulation of biological rhythms. EPL (Europhys Lett) 43(4):363–368
Jung TP, Makeig S, Humphries C, Lee TW, McKeown MJ, Iragui V, Sejnowski TJ (2001) Removing electroencephalographic artifacts by blind source separation. Psychophysiology 37(2):163–178
Kabn (2000) Clustering of text documents by skewness maximization. pp. 435–440
Kalden R, Ibrahim S (2004) Searching for self-similarity in gprs. In: PAM 2004 : passive and active network measurement, pp. 83–92
Karlsson S, Yu J, Akay M (2000) Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study. IEEE Trans Biomed Eng 47(2):228–238 doi:10.1109/10.821766
Kato M, Chen YW, Xu G (2006) Articulated hand tracking by pca-ica approach. In: FGR ’06: Proceedings of the 7th international conference on automatic face and gesture Recognition, IEEE Computer Society, pp. 329–334. doi:10.1109/FGR.2006.21
Katz MJ (1988) Fractals and the analysis of waveforms. Comp Biol Med 18(3):145–156
Kimura J (2001) Electrodiagnosis in diseases of nerve and muscle: principles and practice, 3rd edn. Oxford University Press, New York
Kleine BU, van Dijk JP, Lapatki BG, Zwarts MJ, Stegeman DF (2007) Using two-dimensional spatial information in decomposition of surface EMG signals. J Electromyogr Kinesiol 17(5):535–548
Knox R, Brooks D (1994) Classification of multifunction surface EMG using advanced ar model representations. Proceedings of the 20th annual northeast bioengineering conference, pp. 96–98
Kobayashi M, Musha T (1982) 1/f fluctuation of heartbeat period. IEEE Trans Biomed Eng BME-29(6):456–457 doi:10.1109/TBME.1982.324972
Kolenda (2000) Independent components in text. Advances in independent component analysis. Springer, Berlin, pp. 229–250
Kumar D, Pah ND (2000) Neural networks and wavelet decomposition for classification of surface electromyography. Electromyogr Clin Neurophysiol 40(6):411–421
Kumar DK, Ma N, Burton P (2001) Classification of dynamic multi-channel electromyography by neural network. Electromyogr Clin Neurophysiol 41(7):401–408
Lee TW (1997) Blind separation of delayed and convolved sources. pp. 758–764
Lee TW (1998) Independent component analysis: theory and applications. Kluwer Academic Publishers, Dordrecht
Lee TW, Lewicki MS, Sejnowski TJ (1999) Unsupervised classification with non-gaussian mixture models using ica. In: Proceedings of the 1998 conference on advances in neural information processing systems, MIT Press, Cambridge, MA, USA, pp. 508–514
Lévy-Véhel J, Lutton E (2006) Fractals in Engineering; New Trends in Theory and Applications. Springer,New York Inc., Secaucus, NJ, USA
Lewicki MS, Sejnowski TJ (2000) Learning overcomplete representations. Neural Comput 12(2):337–365
Lowery MM, O’Malley MJ (2003) Analysis and simulation of changes in EMG amplitude during high-level fatiguing contractions. IEEE Trans Biomed Eng 50(9):1052–1062
Mackay DJC (1996) Maximum likelihood and covariant algorithms for independent component analysis. Tech. rep., University of Cambridge, London
Mandelbrot BB (1977) Fractals: Form, chance, and dimension, 1st edn. W. H. Freeman and Co, San Francisco
Mckeown MJ, Makeig S, Brown GG, Jung TP, Kindermann SS, Bell AJ, Sejnowski TJ (1999) Analysis of fMRI data by blind separation into independent spatial components. Hum Brain Map 6(3):160–188
Mckeown MJ, Torpey DC, Gehm WC (2002) Non-invasive monitoring of functionally distinct muscle activations during swallowing. Clin Neurophysiol 113(3):354–366. doi:10.1016/S1388-2457(02)00007-X
Merletti R, Rainoldi A, Farina D (2005) Myoelectric manifestations of muscle fatigue, Electromyography, Wiley-IEEE Press, USA pp. 233–253
Momen K, Krishnan S, Chau T (2007) Real-time classification of forearm electromyographic signals corresponding to user-selected intentional movements for multifunction prosthesis control. IEEE Trans Neu Sys Rehab Eng 15(4):535–542. doi:10.1109/TNSRE.2007.908376
Mosher JC, Lewis PS, Leahy RM (1992) Multiple dipole modeling and localization from spatio-temporal MEG data. IEEE Trans Biomed Eng 39(6):541–557 doi:10.1109/10.141192
Nagata K, Adno K, Magatani K, Yamada M (2005) A classification method of hand movements using multi channel electrode. 27th Annual international conference of the engineering in medicine and biology society, pp. 2375–2378
Nagata K, Magatani K (2004) Development of the assist system to operate a computer for the disabled using multichannel surface EMG. Proceedings of 26th annual international conference of the IEEE engineering in medicine and biology society
Naik G, Kumar D (2010) Identification of hand and finger movements using multi run ICA of surface electromyogram. J Med Sys pp. 1–11–11. doi:10.1007/s10916-010-9548-2
Naik GR, Kumar D (2010) Hybrid feature selection for myoelectric signal classification using MICA. J Elec Eng 1(2):93–99
Naik GR, Kumar DK (2010) Jayadeva: Twin svm for gesture classification using the surface electromyogram. IEEE Trans Infor Technol Biomed 14(2):301–308 doi:10.1109/TITB.2009.2037752
Naik GR, Kumar DK, Palaniswami M (2008) Identification of independent biological sensors-electromyogram example. pp. 1112–1115. IEEE. doi:10.1109/IEMBS.2008.4649355
Naik GR, Kumar DK, Palaniswami M (2008) Source identification and separation using sub-band ICA of sEMG. In: TENCON 2008—2008 IEEE Region 10 Conference, pp. 1–6. IEEE. doi:10.1109/TENCON.2008.4766726 URL http://dx.doi.org/10.1109/TENCON.2008.4766726
Naik GR, Kumar DK, Singh VP, Palaniswami M (2006) Hand gestures for hci using ICA of EMG. In: VisHCI ’06: Proceedings of the HCSNet workshop on Use of vision in human-computer interaction, Australian Computer Society, Inc., Sydney, Australia, pp. 67–72
Naik GR, Kumar DK, Weghorn H, Palaniswami M (2007) Subtle hand gesture identification for hci using temporal decorrelation source separation bss of surface EMG. In: Digital image computing techniques and applications, 9th Biennial conference of the Australian pattern recognition society, Adelaide, Australia, pp. 30–37
Naik GR, Kumar DK, Wheeler K, Arjunan SP (2009) Estimation of muscle fatigue during cyclic contractions using source separation techniques. In: 2009 Digital image computing: techniques and applications, Melbourne, Australia, pp. 217–222. doi:10.1109/DICTA.2009.43
Naik GR, Kumar DK, Yadav V, Wheeler K, Arjunan S (2009) Testing of motor unit synchronization model for localized muscle fatigue. In: 2009 Annual international conference of the IEEE engineering in medicine and biology society, Minneapolis, USA, pp. 360–363. doi:10.1109/IEMBS.2009.5332486
Nakamura H, Yoshida M, Kotani M, Akazawa K, Moritani T (2004) The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part i-measuring techniques. J Electromyogr Kinesiol: Official J Int Soc Electrophysiol Kinesiol 14(4):423–432. doi:10.1016/j.jelekin.2004.01.004
Niedermeyer E, Da Silva FL (1999) Electroencephalography: basic principles, clinical applications, and related fields, 4th edn. Lippincott Williams and Wilkins, Philadelphia, PA
Nussbaum MA (2006) Localized muscle fatigue. Lecture notes on advanced methods in occupational biomechanics. URL http://www.nussbaum.org.vt.edu/courses.htm
Osamu Fukuda TT (2004) Control of an externally powered prosthetic forearm using raw-EMG signals. SICE 40(11):1124–1131
Parra J, Kalitzin SN (2004) Lopes: magnetoencephalography: an investigational tool or a routine clinical technique?. Epilepsy Behav 5(3):277–285
Peng CK, Hausdorff J, Goldberger A (1999) Fractal mechanisms in neural control: human heartbeat and gait dynamics in health and disease. Nonlinear Dynamics, Self-Organization, and biomedicine, Cambridge University Press, Cambridge
Peters J (1967) Surface electrical fields generated by eye movement and eye blink potentials over the scalp. J EEG Technol 7:1129–1159
Petersen K, Hansen LK, Kolenda T, Rostrup E (2000) On the independent components of functional neuroimages. In: 3rd International conference on independent component analysis and blind source separation, pp. 615–620
Petrosian A (1995) Kolmogorov complexity of finite sequences and recognition of different preictal eeg patterns. In: Computer-based medical systems, Proceedings of the 8th IEEE symposium on, pp. 212–217
Rainoldi A, Casale R, Hodges P, Jull G (2005) Applications in rehabilitation medicine and related fields, Electromyography, Wiley-IEEE Press, New York, pp. 403–425
Rajapakse JC, Cichocki A (2002) Sanchez: Independent component analysis and beyond in brain imaging: EEg, MEG, fMRI, and PEt. In: Neural information processing, 2002. ICONIP ’02. Proceedings of the 9th international conference on 1:404–412. doi:10.1109/ICONIP.2002.1202202
Ren XH, Wang Z, Yan Z (2006) Muap extraction and classification based on wavelet transform and ICA for EMG decomposition. Med Biol Eng Comput 44:371–382
Sarkar M, Leong TY (2003) Characterization of medical time series using fuzzy similarity-based fractal dimensions. Artif Intell Med 27(2):201–222
Scherg M, Von Cramon D (1985) Two bilateral sources of the late aep as identified by a spatio-temporal dipole model. Electroencephalogr Clin Neurophysiol 62(1):32–44
Schroeder M (1991) Fractals, chaos, power laws. Freeman, New York
Sorenson (2002) Mean field approaches to independent component analysis. Neu Comput 14:889–918
Stashuk D (2001) EMG signal decomposition: how can it be accomplished and used?. J Electromyogr Kinesiol 11(3):151–173
Subasi A, Kiymik M (2010) Muscle fatigue detection in EMG using time-frequency methods, ICA and neural networks. J Med Sys 34(4):777–785. doi:10.1007/s10916-009-9292-7
Sueaseenak D, Chanwimalueang T, Praliwanon C, Sangworasil M, Pintavirooj C (2009) An eigen based feature on time-frequency representation of EMG. In: 2009 IEEE-RIVF international conference on computing and communication technologies, pp. 1–6. doi:10.1109/RIVF.2009.5174621
Tang AC, Pearlmutter BA (2003) Independent components of magnetoencephalography: localization pp. 129–162
Tenore F, Ramos A, Fahmy A, Acharya S, Etienne-Cummings R, Thakor N (2009) Decoding of individuated finger movements using surface electromyography. IEEE Trans Biomed Eng 56(5):1427–1434. doi:10.1109/TBME.2008.2005485
Tsuji T, Kaneko M (2000) An EMG controlled pointing device using a neural network. SICE 37(5):425–431
Verleger R, Gasser T, Mocks J (1982) Correction of eog artefacts in event related potentials of the eeg: aspects of reliability and validity, psychophysiology. Psychophysiology 19(2):472–480
Vigário R, Särelä J, Jousmäki V, Hämäläinen M, Oja E (2000) Independent component approach to the analysis of eeg and MEG recordings. IEEE Trans Biomed Eng 47(5):589–593 doi:10.1109/10.841330
Weerts TC, Lang PJ (1973) The effects of eye fixation and stimulus and response location on the contingent negative variation (cnv). Biol Psychol 1(1):1–19
Whitton JL, Lue F, Moldofsky H (1978) A spectral method for removing eye movement artifacts from the eeg. Electroencephalogr Clin Neurophysiol 44(6):735–741
Wisbeck J, Barros A, Ojeda R (1998) Application of ICA in the separation of breathing artifacts in ECG signals
Woestenburg JC, Verbaten MN, Slangen JL (1983) The removal of the eye-movement artifact from the eeg by regression analysis in the frequency domain. Biol Psychol 16(1-2):127–147
Xu Z, Xiao S (1997) Fractal dimension of surface EMG and its determinants. In: Engineering in medicine and biology society, 1997. Proceedings of the 19th annual international conference of the IEEE 4:1570–1573
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Naik, G.R., Arjunan, S. & Kumar, D. Applications of ICA and fractal dimension in sEMG signal processing for subtle movement analysis: a review. Australas Phys Eng Sci Med 34, 179–193 (2011). https://doi.org/10.1007/s13246-011-0066-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-011-0066-4