Abstract

There can be no discussion on the accuracy of a measurement result without its proven traceability. Traceability is a fundamental property of a measurement that ensures the measured quantity is comparable to the international definition of the unit with which it is expressed. The task of achieving traceability requires a thorough understanding of the measurement procedure and, in particular, the operating principle of the measuring instrument. In this chapter, the concept of traceability is introduced as it applies to dimensional measurements. The role of instrument calibration in establishing traceability of its measurements is presented for earlier coordinate measuring systems, to serve as a precursor to the discussion on how CT instruments can be calibrated. Finally, methods for assessing task-specific measurement uncertainty are discussed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21(5):733–744CrossRef Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21(5):733–744CrossRef
Zurück zum Zitat Barna SL, Tate MW, Gruner SM, Eikenberry EF (1999) Calibration procedures for charge-coupled device x-ray detectors. Rev Sci Instrum 70(7):2927–2934CrossRef Barna SL, Tate MW, Gruner SM, Eikenberry EF (1999) Calibration procedures for charge-coupled device x-ray detectors. Rev Sci Instrum 70(7):2927–2934CrossRef
Zurück zum Zitat Beers JS, Tucker CD (1976) Intercomparison procedures for gage blocks using electromechanical comparators. National Bureau of Standards Interagency Report NBSIR, pp 76–979 Beers JS, Tucker CD (1976) Intercomparison procedures for gage blocks using electromechanical comparators. National Bureau of Standards Interagency Report NBSIR, pp 76–979
Zurück zum Zitat BIPM (2006) The International system of units (SI), 8th edn. International Organisation for Standardisation, Geneva BIPM (2006) The International system of units (SI), 8th edn. International Organisation for Standardisation, Geneva
Zurück zum Zitat BIPM JCGM 100 (2008a) Evaluation of measurement data—guide to the expression of uncertainty in measurement. International Organisation for Standardisation, Geneva BIPM JCGM 100 (2008a) Evaluation of measurement data—guide to the expression of uncertainty in measurement. International Organisation for Standardisation, Geneva
Zurück zum Zitat BIPM JCGM 101 (2008b) Evaluation of measurement data—supplement 1 to the “Guide to the expression of uncertainty in measurement”—propagation of distributions using a Monte Carlo method. International Organisation for Standardisation, Geneva BIPM JCGM 101 (2008b) Evaluation of measurement data—supplement 1 to the “Guide to the expression of uncertainty in measurement”—propagation of distributions using a Monte Carlo method. International Organisation for Standardisation, Geneva
Zurück zum Zitat BIPM JCGM 200 (2012) International vocabulary of metrology—basic and general concepts and associated terms (VIM), 3rd edn. International Organisation for Standardisation, Geneva BIPM JCGM 200 (2012) International vocabulary of metrology—basic and general concepts and associated terms (VIM), 3rd edn. International Organisation for Standardisation, Geneva
Zurück zum Zitat Braun H, Kyriakou Y, Kachelrieß M, Kalender WA (2010) The influence of the heel effect in cone-beam computed tomography: artifacts in standard and novel geometries and their correction. Phys Med Biol 55:6005–6021CrossRef Braun H, Kyriakou Y, Kachelrieß M, Kalender WA (2010) The influence of the heel effect in cone-beam computed tomography: artifacts in standard and novel geometries and their correction. Phys Med Biol 55:6005–6021CrossRef
Zurück zum Zitat Clackdoyle R, Mennessier C (2011) Centers and centroids of the cone-beam projection of a ball. Phys Med Biol 56:7371–7391CrossRef Clackdoyle R, Mennessier C (2011) Centers and centroids of the cone-beam projection of a ball. Phys Med Biol 56:7371–7391CrossRef
Zurück zum Zitat Davidson DW, Fröjdh C, O’Shea V, Nilsson H-E, Rahman M (2003) Limitations to flat-field correction methods when using an X-ray spectrum. Nucl Instrum Methods Phys Res A 509:146–150CrossRef Davidson DW, Fröjdh C, O’Shea V, Nilsson H-E, Rahman M (2003) Limitations to flat-field correction methods when using an X-ray spectrum. Nucl Instrum Methods Phys Res A 509:146–150CrossRef
Zurück zum Zitat Deng L, Xi X, Li L, Han Y, Yan B (2015) A method to determine the detector locations of the cone-beam projection of the balls’ centers. Phys Med Biol 60:9295–9311CrossRef Deng L, Xi X, Li L, Han Y, Yan B (2015) A method to determine the detector locations of the cone-beam projection of the balls’ centers. Phys Med Biol 60:9295–9311CrossRef
Zurück zum Zitat Doiron T, Beers J (1995) The gauge block handbook. NIST Monograph 180 Doiron T, Beers J (1995) The gauge block handbook. NIST Monograph 180
Zurück zum Zitat Floudas CA, Gounaris CE (2009) A review of recent advances in global optimization. J Glob Optim 45:3–38CrossRef Floudas CA, Gounaris CE (2009) A review of recent advances in global optimization. J Glob Optim 45:3–38CrossRef
Zurück zum Zitat Gruner SM, Eikenberry EF, Tate MW (2001) Comparison of X-ray detectors. In: International tables for crystallography, vol F, pp 143–147 Gruner SM, Eikenberry EF, Tate MW (2001) Comparison of X-ray detectors. In: International tables for crystallography, vol F, pp 143–147
Zurück zum Zitat Gruner SM, Tate MW, Eikenberry EF (2002) Charge-coupled device area X-ray detectors. Rev Sci Instrum 73(8):2815–2843CrossRef Gruner SM, Tate MW, Eikenberry EF (2002) Charge-coupled device area X-ray detectors. Rev Sci Instrum 73(8):2815–2843CrossRef
Zurück zum Zitat Haugh MJ, Charest MR, Ross PW, Lee JJ, Schneider MB, Palmer NE, Teruya AT (2012) Calibration of X-ray imaging devices for accurate intensity measurement. Powder Diffr 27(2):79–86CrossRef Haugh MJ, Charest MR, Ross PW, Lee JJ, Schneider MB, Palmer NE, Teruya AT (2012) Calibration of X-ray imaging devices for accurate intensity measurement. Powder Diffr 27(2):79–86CrossRef
Zurück zum Zitat Hermann G (2007) Geometric error correction in coordinate measurement. Acta Polytechnica Hungarica 4(1):47–61 Hermann G (2007) Geometric error correction in coordinate measurement. Acta Polytechnica Hungarica 4(1):47–61
Zurück zum Zitat Hsieh J (2015) Computed tomography: principles, design, artifacts, and recent advances, 3rd edn. SPIE Press, BellinghamCrossRef Hsieh J (2015) Computed tomography: principles, design, artifacts, and recent advances, 3rd edn. SPIE Press, BellinghamCrossRef
Zurück zum Zitat ISO 15530–3 (2011) Geometrical product specifications (GPS)—coordinate measuring machines (CMM): technique for determining the uncertainty of measurement Part 3 : Use of calibrated workpieces or measurement standards. International Organisation for Standardisation, Geneva ISO 15530–3 (2011) Geometrical product specifications (GPS)—coordinate measuring machines (CMM): technique for determining the uncertainty of measurement Part 3 : Use of calibrated workpieces or measurement standards. International Organisation for Standardisation, Geneva
Zurück zum Zitat ISO 230-7 (2015) Test code for machine tools—Part 7: Geometric accuracy of axes of rotation. International Organisation for Standardisation, Geneva ISO 230-7 (2015) Test code for machine tools—Part 7: Geometric accuracy of axes of rotation. International Organisation for Standardisation, Geneva
Zurück zum Zitat Kanno I, Imamura R, Minami Y, Ohtaka M, Hashimoto M, Ara K, Onabe H (2012) Third-generation computed tomography with energy information of X-rays using a CdTe flat panel detector. Nucl Instrum Methods Phys Res A 695:268–271CrossRef Kanno I, Imamura R, Minami Y, Ohtaka M, Hashimoto M, Ara K, Onabe H (2012) Third-generation computed tomography with energy information of X-rays using a CdTe flat panel detector. Nucl Instrum Methods Phys Res A 695:268–271CrossRef
Zurück zum Zitat Kwan ALC, Seibert JA, Boone JM (2006) An improved method for flat-field correction of flat panel x-ray detector. Med Phys 33(2):391–393CrossRef Kwan ALC, Seibert JA, Boone JM (2006) An improved method for flat-field correction of flat panel x-ray detector. Med Phys 33(2):391–393CrossRef
Zurück zum Zitat Lifton JJ, Malcolm AA, McBride JW (2015) On the uncertainty of surface determination in x-ray computed tomography for dimensional metrology. Meas Sci Technol 26:035003CrossRef Lifton JJ, Malcolm AA, McBride JW (2015) On the uncertainty of surface determination in x-ray computed tomography for dimensional metrology. Meas Sci Technol 26:035003CrossRef
Zurück zum Zitat Moroni G, Petrò S (2016) Impact of the threshold on the performance verification of computerized tomography scanners. Procedia CIRP 43:345–350CrossRef Moroni G, Petrò S (2016) Impact of the threshold on the performance verification of computerized tomography scanners. Procedia CIRP 43:345–350CrossRef
Zurück zum Zitat Muller P, Hiller J, Dai Y, Andreasen JL, Hansen HN, De Chiffre L (2014) Estimation of measurement uncertainties in X-ray computed tomography metrology using the substitution method. CIRP J Manufact Sci Technol 7:222–232CrossRef Muller P, Hiller J, Dai Y, Andreasen JL, Hansen HN, De Chiffre L (2014) Estimation of measurement uncertainties in X-ray computed tomography metrology using the substitution method. CIRP J Manufact Sci Technol 7:222–232CrossRef
Zurück zum Zitat Muralikrishnan B, Sawyer DS, Blackburn CJ, Phillips SD, Borchardt BR, Estler WT (2009) ASME B89.4.19 performance evaluation tests and geometric misalignments in laser trackers. J Res Natl Inst Stand Technol 114:21–35CrossRef Muralikrishnan B, Sawyer DS, Blackburn CJ, Phillips SD, Borchardt BR, Estler WT (2009) ASME B89.4.19 performance evaluation tests and geometric misalignments in laser trackers. J Res Natl Inst Stand Technol 114:21–35CrossRef
Zurück zum Zitat Muralikrishnan B, Ferrucci M, Sawyer DS, Gerner G, Lee V, Blackburn C, Phillips S, Petrov P, Yakovlev Y, Astrelin A, Milligan S, Palmateer J (2015) Volumetric performance evaluation of a laser scanner based on geometric error model. Prec Eng 40:139–150CrossRef Muralikrishnan B, Ferrucci M, Sawyer DS, Gerner G, Lee V, Blackburn C, Phillips S, Petrov P, Yakovlev Y, Astrelin A, Milligan S, Palmateer J (2015) Volumetric performance evaluation of a laser scanner based on geometric error model. Prec Eng 40:139–150CrossRef
Zurück zum Zitat Muralikrishnan B, Phillips S, Sawyer D (2016) Laser trackers for large-scale dimensional metrology: a review. Prec Eng 44:13–28CrossRef Muralikrishnan B, Phillips S, Sawyer D (2016) Laser trackers for large-scale dimensional metrology: a review. Prec Eng 44:13–28CrossRef
Zurück zum Zitat NBS (1975) The International Bureau of Weights and Measures 1875–1975, translation of the BIPM centennial volume, vol 420. NBS Special Publication, pp 77–85 NBS (1975) The International Bureau of Weights and Measures 1875–1975, translation of the BIPM centennial volume, vol 420. NBS Special Publication, pp 77–85
Zurück zum Zitat Pereira PH (2012) Cartesian coordinate measuring machines. In: Hocken RJ, Pereira PH (eds) Coordinate measuring machines and systems, 2nd edn. CRC Press, Boca Raton, pp 61–67 Pereira PH (2012) Cartesian coordinate measuring machines. In: Hocken RJ, Pereira PH (eds) Coordinate measuring machines and systems, 2nd edn. CRC Press, Boca Raton, pp 61–67
Zurück zum Zitat Petrov P, Yakovlev Y, Grigorievsky V, Astrelin A, Sherstuk A (2011) Binary modulation rangefinder. US Patent US 7,973,912 B2 Petrov P, Yakovlev Y, Grigorievsky V, Astrelin A, Sherstuk A (2011) Binary modulation rangefinder. US Patent US 7,973,912 B2
Zurück zum Zitat Santolaria J, Aguilar JJ (2010) Kinematic calibration of articulated arm coordinate measuring machines and robot arms using passive and active self-centering probes and multipose optimization algorithm based in point and length constraints. In: Lazinica A, Kawai H (eds) Robot manipulators new achievements. Intech, Vukovar Santolaria J, Aguilar JJ (2010) Kinematic calibration of articulated arm coordinate measuring machines and robot arms using passive and active self-centering probes and multipose optimization algorithm based in point and length constraints. In: Lazinica A, Kawai H (eds) Robot manipulators new achievements. Intech, Vukovar
Zurück zum Zitat Santolaria J, Majarena AC, Samper D, Brau A, Velázquez J (2014) Articulated arm coordinate measuring machine calibration by laser tracker multilateration. Sci World J 2014:681853CrossRef Santolaria J, Majarena AC, Samper D, Brau A, Velázquez J (2014) Articulated arm coordinate measuring machine calibration by laser tracker multilateration. Sci World J 2014:681853CrossRef
Zurück zum Zitat Schmidgunst C, Ritter D, Lang E (2007) Calibration model of a dual gain flat panel detector for 2D and 3D X-ray imaging. Med Phys 34(9):3649–3664CrossRef Schmidgunst C, Ritter D, Lang E (2007) Calibration model of a dual gain flat panel detector for 2D and 3D X-ray imaging. Med Phys 34(9):3649–3664CrossRef
Zurück zum Zitat Schwenke H, Knapp W, Haitjema H, Weckenmann A, Schmitt R, Delbressine F (2008) Geometric error measurement and compensation of machines—an update. CIRP Ann Manuf Technol 57:660–675 Schwenke H, Knapp W, Haitjema H, Weckenmann A, Schmitt R, Delbressine F (2008) Geometric error measurement and compensation of machines—an update. CIRP Ann Manuf Technol 57:660–675
Zurück zum Zitat Seibert JA, Boone JM, Lindfors KK (1998) Flat-field correction technique for digital detectors. Proc SPIE 3336:348–354CrossRef Seibert JA, Boone JM, Lindfors KK (1998) Flat-field correction technique for digital detectors. Proc SPIE 3336:348–354CrossRef
Zurück zum Zitat Sładek J, Ostrowska K, Gąska A (2013) Modeling and identification of errors of coordinate measuring arms with the use of a metrological model. Measurement 46:667–679CrossRef Sładek J, Ostrowska K, Gąska A (2013) Modeling and identification of errors of coordinate measuring arms with the use of a metrological model. Measurement 46:667–679CrossRef
Zurück zum Zitat Stolfi A, Thompson MK, Carli L, De Chiffre L (2016) Quantifying the contribution of post-processing in computed tomography measurement uncertainty. Procedia CIRP 43:297–302CrossRef Stolfi A, Thompson MK, Carli L, De Chiffre L (2016) Quantifying the contribution of post-processing in computed tomography measurement uncertainty. Procedia CIRP 43:297–302CrossRef
Zurück zum Zitat Tate MW, Chamberlain D, Gruner SM (2005) Area X-ray detector based on a lens-coupled charge-coupled device. Rev Sci Instrum 76:081301CrossRef Tate MW, Chamberlain D, Gruner SM (2005) Area X-ray detector based on a lens-coupled charge-coupled device. Rev Sci Instrum 76:081301CrossRef
Zurück zum Zitat Trapet E, Wäldele F (1996) The virtual CMM concept. Advanced mathematical tools in metrology. World Scientific Publishing Company, pp 238–247 Trapet E, Wäldele F (1996) The virtual CMM concept. Advanced mathematical tools in metrology. World Scientific Publishing Company, pp 238–247
Zurück zum Zitat VDI/VDE 2630 Part 2.1 (2015) Computed tomography in dimensional measurement: determination of the uncertainty of measurement and the test process suitability of coordinate measurement systems with CT sensors. Verein Deutscher Ingenieure e.V., Dusseldorf VDI/VDE 2630 Part 2.1 (2015) Computed tomography in dimensional measurement: determination of the uncertainty of measurement and the test process suitability of coordinate measurement systems with CT sensors. Verein Deutscher Ingenieure e.V., Dusseldorf
Zurück zum Zitat Weckenmann A, Hoffmann J (2012) Probing systems for coordinate measuring machines. In: Hocken RJ, Pereira PH (eds) Coordinate measuring machines and systems, 2nd edn. CRC Press, Boca Raton, pp 100–105 Weckenmann A, Hoffmann J (2012) Probing systems for coordinate measuring machines. In: Hocken RJ, Pereira PH (eds) Coordinate measuring machines and systems, 2nd edn. CRC Press, Boca Raton, pp 100–105
Zurück zum Zitat Williams TC, Shaddix CR (2007) Simultaneous correction of flat field and nonlinearity response of intensified charge-coupled devices. Rev Sci Instrum 78:123702CrossRef Williams TC, Shaddix CR (2007) Simultaneous correction of flat field and nonlinearity response of intensified charge-coupled devices. Rev Sci Instrum 78:123702CrossRef
Zurück zum Zitat Yu Y, Wang J (2012) Beam hardening-respecting flat field correction of digital X-ray detectors. IEEE International Conference on Image Processing, pp 2085–2088 Yu Y, Wang J (2012) Beam hardening-respecting flat field correction of digital X-ray detectors. IEEE International Conference on Image Processing, pp 2085–2088
Metadaten
Titel
Towards Traceability of CT Dimensional Measurements
verfasst von
Massimiliano Ferrucci
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-59573-3_7

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.