Skip to main content

Application Examples of STATCOM

Flexible AC Transmission Systems

Abstract

The chapter starts with a brief introduction of the STATCOM technology and then provides a number of typical applications of the STATCOM from around the world. Some application examples are general transmission system applications, where the purpose of the STATCOM is to regulate and support the ac voltage and to minimize the over- and undervoltages that may occur during various faults and event in the network, including the commutation failure of large HVDC schemes. Some examples demonstrate the ability to improve the power quality, e.g., due to disturbing loads such as arc furnaces, wind farms, single-phase tractions loads, etc. Some STATCOM applications demonstrate the capability of the STATCOM to damp power system oscillations and to increase the power capabilities of ac lines.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  • Anderson, P.M., Farmer, R.G.: Subsynchronous resonance; Chapter 6, pages 229 to 286, In: Series capacitor studies, testing and maintenance, Chapter 8. In: Series Compensation of Power Systems. PBLSH! Inc., Encinitas (1996)

    Google Scholar 

  • Cao, Z., Shi, Y., et al.: Simulation analysis on sub synchronous oscillation at sending end of ±500 kV power transmission project from Hulun Buir to Liaoning. Power Syst. Technol. 35(6), 107–112 (2011)

    Google Scholar 

  • Diaz de Leon, J.A., Kehrli, B., Zalay, A.: How the Lake Bonney wind farm met ESCOSA’s, NEMMCO’s, and ElectraNet’s rigorous interconnecting requirements. In: IEEE/PES Transmission and Distribution Conference and Exposition (2008)

    Google Scholar 

  • Farmer, R.G., Schwalb, A.L., Katz, E.: Navajo project report on subsynchronous resonance analysis and solutions. IEEE Trans. Power Syst. PAS-96(4), 1226–1232 (1977)

    Article  Google Scholar 

  • Hanson, D.J., Horwill, C., Loughran, J., Monkhouse D.R.: The application of a relocatable STATCOM on the UK National Grid system. In: CIGRÉ Regional Conference, New Delhi (2001)

    Google Scholar 

  • Hasler, J-P, Sneed, T., Holmberg, M., Lund, J., Näslund, M.: Power Quality Analysis and IEC Standard Evaluation Using Measurements and Simulations in a STATCOM Application. Paper C4-114. CIGRÉ, Paris (2018)

    Google Scholar 

  • Horwill, C., Totterdell, A.J., Hanson, D.J., et al.: Commission of a 225 MVAr SVC incorporating a ±75MVAr STATCOM AT NGC’s 400kV east claydon substation. In: Seventh International Conference on AC-DC Power Transmission, pp. 232–237. Institution of Electrical Engineers, London (2001)

    Chapter  Google Scholar 

  • IEC/TR 61000-3-7: Electromagnetic Compatibility (EMC) – Part 3–7: Limits – Assessment of Emission Limits for the Connection of Fluctuating Installations to MV, HV and EHV Power Systems, Ed.2.0. BSI, London (2008)

    Google Scholar 

  • Li Chunhua, Zhang Yongkang, et al.: Artificial short circuit test and analysis of ±200MVAr static synchronous compensator artificial short-circuit test and analysing in Southern power grid. Autom. Elect. Power Syst. 37(4), 125–129 (2013)

    Google Scholar 

  • Liu Wen-hua, Song Qiang, Teng Le-tian, et al.: ±50MVAr STATCOM based on chain circuit converter employing IGCT’s. Proc. CSEE. 28(15), 55–60 (2008)

    Google Scholar 

  • Rao, H., Xu, S., Zhao, Y., et al.: Research and application of multiple STATCOMs to improve the stability of ACDC power systems in China Southern Grid. IET J. 10(13), 3111–3118 (2016)

    Google Scholar 

  • Woodhouse, M.L., Donoghue, M.W., Osborne, M.M.: Type testing of the GTO valves for a novel STATCOM converter. In: Seventh International Conference on AC-DC Power Transmission. Institution of Electrical Engineers, London (2001)

    Google Scholar 

  • Xiao Leisi, Li Ming, et al.: Manual instantaneous earthing test of CSG transmission lines. South. Power Syst. Technol. 9(3), 63–66 (2015)

    Google Scholar 

  • Yao Weizheng, Liu Gang, Hu Siquan, et al.: Research on improved control strategies of STATCOM for LCC-HVDC weak receiving station. Proc. CSEE. 38(12), 3362–3670 (2018)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bjarne Andersen .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG 2019

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Xu, S. et al. (2019). Application Examples of STATCOM. In: Nilsson, S. (eds) Flexible AC Transmission Systems . CIGRE Green Books. Springer, Cham. https://doi.org/10.1007/978-3-319-71926-9_13-1

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-71926-9_13-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-71926-9

  • Online ISBN: 978-3-319-71926-9

  • eBook Packages: Springer Reference EnergyReference Module Computer Science and Engineering

Publish with us

Policies and ethics

Chapter history

  1. Latest

    Application Examples of STATCOM
    Published:
    12 March 2020

    DOI: https://doi.org/10.1007/978-3-319-71926-9_13-2

  2. Original

    Application Examples of STATCOM
    Published:
    16 May 2019

    DOI: https://doi.org/10.1007/978-3-319-71926-9_13-1