Fast Groupwise 4D Deformable Image Registration for Irregular Breathing Motion Estimation

verfasst von : Bartłomiej W. Papież, Daniel R. McGowan, Michael Skwarski, Geoff S. Higgins, Julia A. Schnabel, Sir Michael Brady

Erschienen in: Biomedical Image Registration

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Tumor heterogeneity can be assessed quantitatively by analyzing dynamic contrast-enhanced imaging modalities potentially leading to improvement in the diagnosis and treatment of cancer, for example of the lung. However, the acquisition of standard lung sequences is often compromised by irregular breathing motion artefacts, resulting in unsystematic errors when estimating tissue perfusion parameters. In this work, we illustrate implicit deformable image registration that integrates the Demons algorithm using the local correlation coefficient as a similarity measure, and locally adaptive regularization that enables incorporation of both spatial sliding motions and irregular temporal motion patterns. We also propose a practical numerical approximation of the regularization model to improve both computational time and registration accuracy, which are important when analyzing long clinical sequences. Our quantitative analysis of 4D lung Computed Tomography and Computed Tomography Perfusion scans from clinical lung trial shows significant improvement over state-of-the-art pairwise registration approaches.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Bai, W., Brady, M.: Regularized B-spline deformable registration for respiratory motion correction in PET images. Phys. Med. Biol. 54(9), 2719 (2009)CrossRef Bai, W., Brady, M.: Regularized B-spline deformable registration for respiratory motion correction in PET images. Phys. Med. Biol. 54(9), 2719 (2009)CrossRef
2.
Zurück zum Zitat Castillo, E., Castillo, R., Martinez, J., Shenoy, M., Guerrero, T.: Four-dimensional deformable image registration using trajectory modeling. Phys. Med. Biol. 55(1), 305 (2009)CrossRef Castillo, E., Castillo, R., Martinez, J., Shenoy, M., Guerrero, T.: Four-dimensional deformable image registration using trajectory modeling. Phys. Med. Biol. 55(1), 305 (2009)CrossRef
3.
Zurück zum Zitat Castillo, R., Castillo, E., Guerra, R., Johnson, V., McPhail, T., Garg, A., Guerrero, T.: A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Phys. Med. Biol. 54, 1849–1870 (2009)CrossRef Castillo, R., Castillo, E., Guerra, R., Johnson, V., McPhail, T., Garg, A., Guerrero, T.: A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Phys. Med. Biol. 54, 1849–1870 (2009)CrossRef
4.
Zurück zum Zitat Craciunescu, O.I., Yoo, D.S., Cleland, E., Muradyan, N., Carroll, M.D., MacFall, J.R., Barboriak, D.P., Brizel, D.M.: Dynamic contrast-enhanced MRI in head-and-neck cancer: the impact of region of interest selection on the intra-and interpatient variability of pharmacokinetic parameters. Int. J. Radiat. Oncol. Biol. Phys. 82(3), e345–e350 (2012)CrossRef Craciunescu, O.I., Yoo, D.S., Cleland, E., Muradyan, N., Carroll, M.D., MacFall, J.R., Barboriak, D.P., Brizel, D.M.: Dynamic contrast-enhanced MRI in head-and-neck cancer: the impact of region of interest selection on the intra-and interpatient variability of pharmacokinetic parameters. Int. J. Radiat. Oncol. Biol. Phys. 82(3), e345–e350 (2012)CrossRef
5.
Zurück zum Zitat García-Figueiras, R., Goh, V.J., Padhani, A.R., Baleato-González, S., Garrido, M., León, L., Gómez-Caamaño, A.: CT perfusion in oncologic imaging: a useful tool? Am. J. Roentgenol. 200(1), 8–19 (2013)CrossRef García-Figueiras, R., Goh, V.J., Padhani, A.R., Baleato-González, S., Garrido, M., León, L., Gómez-Caamaño, A.: CT perfusion in oncologic imaging: a useful tool? Am. J. Roentgenol. 200(1), 8–19 (2013)CrossRef
6.
Zurück zum Zitat Geng, X., Christensen, G.E., Gu, H., Ross, T.J., Yang, Y.: Implicit reference-based group-wise image registration and its application to structural and functional MRI. Neuroimage 47(4), 1341–1351 (2009)CrossRef Geng, X., Christensen, G.E., Gu, H., Ross, T.J., Yang, Y.: Implicit reference-based group-wise image registration and its application to structural and functional MRI. Neuroimage 47(4), 1341–1351 (2009)CrossRef
7.
Zurück zum Zitat Godenschweger, F., Kägebein, U., Stucht, D., Yarach, U., Sciarra, A., Yakupov, R., Lüsebrink, F., Schulze, P., Speck, O.: Motion correction in MRI of the brain. Phys. Med. Biol. 61(5), R32 (2016)CrossRef Godenschweger, F., Kägebein, U., Stucht, D., Yarach, U., Sciarra, A., Yakupov, R., Lüsebrink, F., Schulze, P., Speck, O.: Motion correction in MRI of the brain. Phys. Med. Biol. 61(5), R32 (2016)CrossRef
9.
Zurück zum Zitat He, K., Sun, J., Tang, X.: Guided image filtering. IEEE Trans. Pattern Anal. Mach. Intell. 35(6), 1397–1409 (2013)CrossRef He, K., Sun, J., Tang, X.: Guided image filtering. IEEE Trans. Pattern Anal. Mach. Intell. 35(6), 1397–1409 (2013)CrossRef
10.
Zurück zum Zitat Koyama, H., Ohno, Y., Seki, S., Nishio, M., Yoshikawa, T., Matsumoto, S., Sugimura, K.: Magnetic resonance imaging for lung cancer. J. Thorac. Imaging 28(3), 138–150 (2013)CrossRef Koyama, H., Ohno, Y., Seki, S., Nishio, M., Yoshikawa, T., Matsumoto, S., Sugimura, K.: Magnetic resonance imaging for lung cancer. J. Thorac. Imaging 28(3), 138–150 (2013)CrossRef
11.
Zurück zum Zitat Lorenzi, M., Ayache, N., Frisoni, G.B., Pennec, X., Alzheimer’s Disease Neuroimaging Initiative (ADNI): LCC-Demons: a robust and accurate symmetric diffeomorphic registration algorithm. Neuroimage 81, 470–483 (2013)CrossRef Lorenzi, M., Ayache, N., Frisoni, G.B., Pennec, X., Alzheimer’s Disease Neuroimaging Initiative (ADNI): LCC-Demons: a robust and accurate symmetric diffeomorphic registration algorithm. Neuroimage 81, 470–483 (2013)CrossRef
12.
Zurück zum Zitat McClelland, J.R., Blackall, J.M., Tarte, S., Chandler, A.C., Hughes, S., Ahmad, S., Landau, D.B., Hawkes, D.J.: A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med. Phys. 33(9), 3348–3358 (2006)CrossRef McClelland, J.R., Blackall, J.M., Tarte, S., Chandler, A.C., Hughes, S., Ahmad, S., Landau, D.B., Hawkes, D.J.: A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med. Phys. 33(9), 3348–3358 (2006)CrossRef
13.
Zurück zum Zitat Metz, C.T., Klein, S., Schaap, M., van Walsum, T., Niessen, W.J.: Nonrigid registration of dynamic medical imaging data using nD+ t B-splines and a groupwise optimization approach. Med. Image Anal. 15(2), 238–249 (2011)CrossRef Metz, C.T., Klein, S., Schaap, M., van Walsum, T., Niessen, W.J.: Nonrigid registration of dynamic medical imaging data using nD+ t B-splines and a groupwise optimization approach. Med. Image Anal. 15(2), 238–249 (2011)CrossRef
14.
Zurück zum Zitat Papież, B.W., Franklin, J., Heinrich, M.P., Gleeson, F.V., Schnabel, J.A.: Liver motion estimation via locally adaptive over-segmentation regularization. In: Navab, N., Hornegger, J., Wells, W.M., Frangi, A.F. (eds.) MICCAI 2015. LNCS, vol. 9351, pp. 427–434. Springer, Cham (2015). https://doi.org/10.1007/978-3-319-24574-4_51CrossRef Papież, B.W., Franklin, J., Heinrich, M.P., Gleeson, F.V., Schnabel, J.A.: Liver motion estimation via locally adaptive over-segmentation regularization. In: Navab, N., Hornegger, J., Wells, W.M., Frangi, A.F. (eds.) MICCAI 2015. LNCS, vol. 9351, pp. 427–434. Springer, Cham (2015). https://​doi.​org/​10.​1007/​978-3-319-24574-4_​51CrossRef
15.
Zurück zum Zitat Papież, B.W., Heinrich, M.P., Fehrenbach, J., Risser, L., Schnabel, J.A.: An implicit sliding-motion preserving regularisation via bilateral filtering for deformable image registration. Med. Image Anal. 18(8), 1299–1311 (2014)CrossRef Papież, B.W., Heinrich, M.P., Fehrenbach, J., Risser, L., Schnabel, J.A.: An implicit sliding-motion preserving regularisation via bilateral filtering for deformable image registration. Med. Image Anal. 18(8), 1299–1311 (2014)CrossRef
16.
Zurück zum Zitat Schnabel, J.A., Heinrich, M.P., Papież, B.W., Brady, J.M.: Advances and challenges in deformable image registration: from image fusion to complex motion modelling. Med. Image Anal. 33, 145–148 (2016)CrossRef Schnabel, J.A., Heinrich, M.P., Papież, B.W., Brady, J.M.: Advances and challenges in deformable image registration: from image fusion to complex motion modelling. Med. Image Anal. 33, 145–148 (2016)CrossRef
17.
Zurück zum Zitat Sotiras, A., Davatzikos, C., Paragios, N.: Deformable medical image registration: a survey. IEEE Trans. Med. Imaging 32(7), 1153–1190 (2013)CrossRef Sotiras, A., Davatzikos, C., Paragios, N.: Deformable medical image registration: a survey. IEEE Trans. Med. Imaging 32(7), 1153–1190 (2013)CrossRef
18.
Zurück zum Zitat Vandemeulebroucke, J., Rit, S., Kybic, J., Clarysse, P., Sarrut, D.: Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs. Med. Phys. 38(1), 166–178 (2011)CrossRef Vandemeulebroucke, J., Rit, S., Kybic, J., Clarysse, P., Sarrut, D.: Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs. Med. Phys. 38(1), 166–178 (2011)CrossRef
19.
Zurück zum Zitat Vercauteren, T., Pennec, X., Perchant, A., Ayache, N.: Diffeomorphic demons: efficient non-parametric image registration. Neuroimage 45, S61–S72 (2009)CrossRef Vercauteren, T., Pennec, X., Perchant, A., Ayache, N.: Diffeomorphic demons: efficient non-parametric image registration. Neuroimage 45, S61–S72 (2009)CrossRef
20.
Zurück zum Zitat von Siebenthal, M., Szekely, G., Gamper, U., Boesiger, P., Lomax, A., Cattin, P.: 4D MR imaging of respiratory organ motion and its variability. Phys. Med. Biol. 52(6), 1547 (2007)CrossRef von Siebenthal, M., Szekely, G., Gamper, U., Boesiger, P., Lomax, A., Cattin, P.: 4D MR imaging of respiratory organ motion and its variability. Phys. Med. Biol. 52(6), 1547 (2007)CrossRef
21.
Zurück zum Zitat Wu, G., Wang, Q., Shen, D., Alzheimer’s Disease NeuroImaging Initiative, et al.: Registration of longitudinal brain image sequences with implicit template and spatial-temporal heuristics. NeuroImage 59(1), 404–421 (2012)CrossRef Wu, G., Wang, Q., Shen, D., Alzheimer’s Disease NeuroImaging Initiative, et al.: Registration of longitudinal brain image sequences with implicit template and spatial-temporal heuristics. NeuroImage 59(1), 404–421 (2012)CrossRef
Metadaten
Titel
Fast Groupwise 4D Deformable Image Registration for Irregular Breathing Motion Estimation
verfasst von
Bartłomiej W. Papież
Daniel R. McGowan
Michael Skwarski
Geoff S. Higgins
Julia A. Schnabel
Sir Michael Brady
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-92258-4_4