Assessment of the Structural Integrity of C3–C5 Cervical Porcine Vertebrae Model Based on 2D Classic CAD, 3D Scanner and 3D Computed Tomography

verfasst von : J. A. Beltrán-Fernández, L. H. Hernández-Gómez, G. Urriolagoitia-Calderón, A. González-Rebatú, G. Urriolagoitia-Sosa, M. M. Galán Vera, E. Escalante-Rodríguez

Erschienen in: Analysis and Design of Biological Materials and Structures

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this chapter, the biomechanical behavior of C3–C5 porcine cervical vertebrae is analyzed. The objective of this evaluation is to establish the advantages and limitations of three numerical procedures when a compressive load is applied. In a first stage, a damaged C4 vertebral body is instrumented with a bone graft and a titanium alloy (Ti-6A1-4V) cervical plate fixed with titanium alloy screws. In the second stage, the biomechanical integrity of a healthy C3–C5 unit is studied. The required numerical models were created with three different techniques; these are 2D Computer Tomography (CT), 3D ZScan and CT scanning with a Siemens Emotion system. This was done in conjunction with Pro-E Wildfire 4.0, Scan IP 3.1, UGS NX-4 and Geomagics R 10 codes. Lateral displacements among the upper and lower surfaces of the vertebral bodies and the bone graft, as well as the von Misses stresses, were calculated. Numerical differences from the biomechanical models are discussed. In order to establish a performance criterion, the results obtained were compared against those obtained for the case of the instrumented C3–C5 unit. In order to establish helpful criteria to optimize the therapeutic procedures before a surgery is performed, the analysis of the results was focused to demonstrate that DICOM methodology can be applied when a biomechanical simulation for a patient is required. It is possible, to apply this technique safely as it is not invasive and geometrical parameters are obtained directly from a tomography taken at a hospital. On the other hand, classical CAD models and Z scan methodology has shown to be useful when specimens are numerically analyzed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat D’Amico, D.S., Cisilino, A.P., Sammartino, M.R., Capiel, C.: Modelado computacional de estructuras óseas utilizando el Método de los Elementos Finitos y tomografías computarizadas, Análisis de la estabilidad de un implante Gleno-Humeral. Mecánica Computacional V. XXIV. A. Larreteguy (Editor). Argentina (2005) D’Amico, D.S., Cisilino, A.P., Sammartino, M.R., Capiel, C.: Modelado computacional de estructuras óseas utilizando el Método de los Elementos Finitos y tomografías computarizadas, Análisis de la estabilidad de un implante Gleno-Humeral. Mecánica Computacional V. XXIV. A. Larreteguy (Editor). Argentina (2005)
2.
Zurück zum Zitat Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Calderón, G., Urriolagoitia-Sosa, G., González-Revattú, A., Dufoo-Olvera, M.: Mechanical behavior of a calcium phosphate ceramic bone graft used in the rehabilitation of a C4 human vertebra. Appl. Mech. Mater. 7–8, 101–106 (2007)CrossRef Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Calderón, G., Urriolagoitia-Sosa, G., González-Revattú, A., Dufoo-Olvera, M.: Mechanical behavior of a calcium phosphate ceramic bone graft used in the rehabilitation of a C4 human vertebra. Appl. Mech. Mater. 7–8, 101–106 (2007)CrossRef
3.
Zurück zum Zitat Ortosintese: Catalog of products 2006, Rua Friedrich Von Voith, 896-Jaragua, Brasil (2006) Ortosintese: Catalog of products 2006, Rua Friedrich Von Voith, 896-Jaragua, Brasil (2006)
4.
Zurück zum Zitat Beltrán Fernández, J.A., Hernández Gómez, L.H., Urriolagoitia Calderón, G., Dufoo Olvera, M., González Rebatú, A.: Distribución de esfuerzos por la acción de cargas de compresión en la vértebra cervical C5, empleando el Método del Elemento Finito, Científica, 9(3),135–142 (2005), Julio-Septiembre del 2005, ISSN 1665–0654 Beltrán Fernández, J.A., Hernández Gómez, L.H., Urriolagoitia Calderón, G., Dufoo Olvera, M., González Rebatú, A.: Distribución de esfuerzos por la acción de cargas de compresión en la vértebra cervical C5, empleando el Método del Elemento Finito, Científica, 9(3),135–142 (2005), Julio-Septiembre del 2005, ISSN 1665–0654
5.
Zurück zum Zitat Ruíz-Muñoz, E.R., Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Sosa, G., Urriolagoitia-Calderón, G.: Técnicas de modelado en 3D aplicado a casos de vértebras porcinas por medio de un escaner 3D y tomografías. Conferencia XXV Congreso Nacional de Investigación Biomédica, UANL-Facultad de Medicina. Monterrey, México (2009) Ruíz-Muñoz, E.R., Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Sosa, G., Urriolagoitia-Calderón, G.: Técnicas de modelado en 3D aplicado a casos de vértebras porcinas por medio de un escaner 3D y tomografías. Conferencia XXV Congreso Nacional de Investigación Biomédica, UANL-Facultad de Medicina. Monterrey, México (2009)
6.
Zurück zum Zitat Ruiz Muñoz, E.R.: Análisis de la estabilización segmentaria en especímenes de columna lumbar porcina (L2–L5) con cerclaje interespinoso empleando cinturones de poliamida 6/6. Tesis de maestría, SEPI—ESIME Zacatenco, México (2010) Ruiz Muñoz, E.R.: Análisis de la estabilización segmentaria en especímenes de columna lumbar porcina (L2–L5) con cerclaje interespinoso empleando cinturones de poliamida 6/6. Tesis de maestría, SEPI—ESIME Zacatenco, México (2010)
7.
Zurück zum Zitat Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Sosa, G., González-Rebatu, A., Urriolagoitia-Calderón, G.: Evaluation of a C3–C5 human cervical model created by computer tomography CT and 3D scan under compression loading, 3rd international conference on advanced computational engineering and experimenting, ACE-X 2009, book ok abstracts, pp. 108–109 (2009) Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Sosa, G., González-Rebatu, A., Urriolagoitia-Calderón, G.: Evaluation of a C3–C5 human cervical model created by computer tomography CT and 3D scan under compression loading, 3rd international conference on advanced computational engineering and experimenting, ACE-X 2009, book ok abstracts, pp. 108–109 (2009)
8.
Zurück zum Zitat Beltran-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Calderón, G., González-Rebatú, A., Urriolagoitia-Sosa, G.: Biomechanics and numerical evaluation of cervical porcine models considering compressive loads using 2D classic computer tomography CT, 3D scanner and 3D computed tomography, advances in experimental mechanics VII. In: Selected peer reviewed papers from 7th BSSM International Conference on Advances in Experimental Mechanics, Transtech Publications, Liverpool, vol. 24–25, pp. 287–295 (2010) Beltran-Fernández, J.A., Hernández-Gómez, L.H., Urriolagoitia-Calderón, G., González-Rebatú, A., Urriolagoitia-Sosa, G.: Biomechanics and numerical evaluation of cervical porcine models considering compressive loads using 2D classic computer tomography CT, 3D scanner and 3D computed tomography, advances in experimental mechanics VII. In: Selected peer reviewed papers from 7th BSSM International Conference on Advances in Experimental Mechanics, Transtech Publications, Liverpool, vol. 24–25, pp. 287–295 (2010)
9.
Zurück zum Zitat Ruíz-Muñoz, E.R., Beltrán-Fernández, J.A., Hernández-Gómez, L.H., González- Rebatú, A.: Análisis de la estabilización segmentaria en especímenes de columna lumbar porcina L3–L5, con cerclaje interespinoso empleando collarines de poliamida 6/6”. IX Congreso Iberoamericano De Ingenieria Mecanica, Cibim 09. FEIBIM—Federación Iberoamericana de Ingeniería Mecánica, Escuela Técnica Superior de Ingenieros Industriales de la Universidad de las Palmas de Gran Canaria, España. 17–20 Noviembre (2009) Ruíz-Muñoz, E.R., Beltrán-Fernández, J.A., Hernández-Gómez, L.H., González- Rebatú, A.: Análisis de la estabilización segmentaria en especímenes de columna lumbar porcina L3–L5, con cerclaje interespinoso empleando collarines de poliamida 6/6”. IX Congreso Iberoamericano De Ingenieria Mecanica, Cibim 09. FEIBIM—Federación Iberoamericana de Ingeniería Mecánica, Escuela Técnica Superior de Ingenieros Industriales de la Universidad de las Palmas de Gran Canaria, España. 17–20 Noviembre (2009)
10.
Zurück zum Zitat Beltrán-Fernández, J.A.: Análisis numérico de las cervicales C3–C7 asociado al problema del latigazo cervical, Tesis de doctorado, SEPI—ESIME Zacatenco, México (2007) Beltrán-Fernández, J.A.: Análisis numérico de las cervicales C3–C7 asociado al problema del latigazo cervical, Tesis de doctorado, SEPI—ESIME Zacatenco, México (2007)
11.
Zurück zum Zitat Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Merchan-Cruz, E.A., Urriolagoitia-Calderón, G., González-Rebatú, A., Dufoo-Olvera, M., Urriolagoitia-Sosa, G.: Modelling of a cervical plate and human cervical section C3 C5 under compression loading conditions using the finite element method. Appl. Mech. Mater. 13–14, 49–56 (2008)CrossRef Beltrán-Fernández, J.A., Hernández-Gómez, L.H., Merchan-Cruz, E.A., Urriolagoitia-Calderón, G., González-Rebatú, A., Dufoo-Olvera, M., Urriolagoitia-Sosa, G.: Modelling of a cervical plate and human cervical section C3 C5 under compression loading conditions using the finite element method. Appl. Mech. Mater. 13–14, 49–56 (2008)CrossRef
12.
Zurück zum Zitat Müller, W.: Manual of Internal Fixation, 3rd ed. Científico-Médica, Barcelona (1992) Müller, W.: Manual of Internal Fixation, 3rd ed. Científico-Médica, Barcelona (1992)
13.
Zurück zum Zitat Hernández-Gómez, L.H., Beltran-Fernández, J.A., Urriolagoitia-Calderón, G., González-Rebatú, A., Galan-Vera, M.M., Urriolagoitia-Sosa, G.: Biomechanical characterization of analysis of adjacent vertebra behavior using porcine specimens. Key Eng. Mater. 478, 103--111 (2011) Hernández-Gómez, L.H., Beltran-Fernández, J.A., Urriolagoitia-Calderón, G., González-Rebatú, A., Galan-Vera, M.M., Urriolagoitia-Sosa, G.: Biomechanical characterization of analysis of adjacent vertebra behavior using porcine specimens. Key Eng. Mater. 478, 103--111 (2011)
14.
Zurück zum Zitat Zcorp: Self-Positioning Handheld 3D Scanner, Method Sheet: Scanning Multi-colored or Multi-shaded Part, Document: MS020016 (2007) Zcorp: Self-Positioning Handheld 3D Scanner, Method Sheet: Scanning Multi-colored or Multi-shaded Part, Document: MS020016 (2007)
15.
Zurück zum Zitat Jeremy, C., et al.: Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone. Clin. Biomech. 21, 235–244 (2006)CrossRef Jeremy, C., et al.: Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone. Clin. Biomech. 21, 235–244 (2006)CrossRef
16.
Zurück zum Zitat Moore, Ch., et al.: The evaluation of a biphasic calcium phosphate ceramic for use in grafting long-bone diaphyseal defects. J. Orthop. Res. 5, 356–365 (1987)CrossRef Moore, Ch., et al.: The evaluation of a biphasic calcium phosphate ceramic for use in grafting long-bone diaphyseal defects. J. Orthop. Res. 5, 356–365 (1987)CrossRef
Metadaten
Titel
Assessment of the Structural Integrity of C3–C5 Cervical Porcine Vertebrae Model Based on 2D Classic CAD, 3D Scanner and 3D Computed Tomography
verfasst von
J. A. Beltrán-Fernández
L. H. Hernández-Gómez
G. Urriolagoitia-Calderón
A. González-Rebatú
G. Urriolagoitia-Sosa
M. M. Galán Vera
E. Escalante-Rodríguez
Copyright-Jahr
2012
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-22131-6_1

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.